1.
PLoS One ; 17(8): e0272768, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36044530

RESUMEN

OBJECTIVES: Positron emission tomography (PET) is susceptible to patient movement during a scan. Head motion is a continuing problem for brain PET imaging and diagnostic assessments. Physical head restraints and external motion tracking systems are most commonly used to address to this issue. Data-driven methods offer substantial advantages, such as retroactive processing but typically require manual interaction for robustness. In this work, we introduce a time-of-flight (TOF) weighted positron emission particle tracking (PEPT) algorithm that facilitates fully automated, data-driven head motion detection and subsequent automated correction of the raw listmode data. MATERIALS METHODS: We used our previously published TOF-PEPT algorithm Dustin Osborne et al. (2017), Tasmia Rahman Tumpa et al., Tasmia Rahman Tumpa et al. (2021) to automatically identify frames where the patient was near-motionless. The first such static frame was used as a reference to which subsequent static frames were registered. The underlying rigid transformations were estimated using weak radioactive point sources placed on radiolucent glasses worn by the patient. Correction of raw event data were achieved by tracking the point sources in the listmode data which was then repositioned to allow reconstruction of a single image. To create a "gold standard" for comparison purposes, frame-by-frame image registration based correction was implemented. The original listmode data was used to reconstruct an image for each static frame detected by our algorithm and then applying manual landmark registration and external software to merge these into a single image. RESULTS: We report on five patient studies. The TOF-PEPT algorithm was configured to detect motion using a 500 ms window. Our event-based correction produced images that were visually free of motion artifacts. Comparison of our algorithm to a frame-based image registration approach produced results that were nearly indistinguishable. Quantitatively, Jaccard similarity indices were found to be in the range of 85-98% for the former and 84-98% for the latter when comparing the static frame images with the reference frame counterparts. DISCUSSION: We have presented a fully automated data-driven method for motion detection and correction of raw listmode data. Easy to implement, the approach achieved high temporal resolution and reliable performance for head motion correction. Our methodology provides a mechanism by which patient motion incurred during imaging can be assessed and corrected post hoc.


Asunto(s)
Electrones , Procesamiento de Imagen Asistido por Computador , Algoritmos , Artefactos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Movimiento (Física) , Movimiento , Fantasmas de Imagen , Tomografía de Emisión de Positrones/métodos
2.
J Vasc Access ; 18(3): 264-268, 2017 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-26044902

RESUMEN

INTRODUCTION: The AXERA 2 low-angle vascular access device utilizes a dual arteriotomy mechanism in which the standard access tract is compressed by a vascular sheath inserted over the second, low-angle tract. It is unknown whether this device could be effectively used with 21-gauge micropuncture access, as the micropuncture introducer makes a larger arteriotomy than the 19-gauge needle provided with the AXERA 2 system. MATERIALS AND METHODS: A retrospective review was performed on 189 patients who underwent common femoral artery access for diagnostic cerebrovascular angiography using either combined micropuncture and AXERA 2 access or standard access with manual pressure hemostasis. Demographic and procedural data were reviewed along with complications related to vascular access and times to bed elevation, ambulation and discharge. RESULTS: Combined micropuncture and AXERA 2 access was performed on 110 patients and 79 patients had standard access. The AXERA device was successfully used in 91.8% of the cases. Demographic data, anticoagulant use and sheath sizes were similar between both subsets. Use of the AXERA 2 was associated with two bleeding complications (1.8%) compared with 10 (12.7%) with manual pressure hemostasis alone. Institution-specific protocol allowed shorter mean manual compression time, as well as shorter times to ambulation and discharge with the AXERA 2. CONCLUSIONS: Use of the AXERA 2 device with micropuncture access did not infer increased bleeding risk than standard arterial access in this patient series. The considerable incidence of device use failures suggests a learning curve associated with its use.


Asunto(s)
Angiografía Cerebral/métodos , Arteria Femoral , Angiografía Cerebral/efectos adversos , Angiografía Cerebral/instrumentación , Competencia Clínica , Diseño de Equipo , Falla de Equipo , Arteria Femoral/diagnóstico por imagen , Hemorragia/etiología , Hemorragia/prevención & control , Técnicas Hemostáticas , Humanos , Curva de Aprendizaje , Punciones , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Dispositivos de Acceso Vascular
3.
EJNMMI Res ; 6(1): 89, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27957721

RESUMEN

BACKGROUND: 90Y PET/CT post-radioembolization imaging has demonstrated that the distribution of 90Y in a tumor can be non-uniform. Using computational modeling, we predicted the dosimetric impact of post-treatment 90Y PET/CT-guided percutaneous ablation of the portions of a tumor receiving the lowest absorbed dose. A cohort of fourteen patients with non-resectable liver cancer previously treated using 90Y radioembolization were included in this retrospective study. Each patient exhibited potentially under-treated areas of tumor following treatment based on quantitative 90Y PET/CT. 90Y PET/CT was used to guide electrode placement for simulated adjuvant radiofrequency ablation in areas of tumor receiving the lowest dose. The finite element method was used to solve Penne's bioheat transport equation, coupled with the Arrhenius thermal cell-death model to determine 3D thermal ablation zones. Tumor and unablated tumor absorbed-dose metrics (average dose, D50, D70, D90, V100) following ablation were compared, where D70 is the minimum dose to 70% of tumor and V100 is the fractional tumor volume receiving more than 100 Gy. RESULTS: Compared to radioembolization alone, 90Y radioembolization with adjuvant ablation was associated with predicted increases in all tumor dose metrics evaluated. The mean average absorbed dose increased by 11.2 ± 6.9 Gy. Increases in D50, D70, and D90 were 11.0 ± 6.9 Gy, 13.3 ± 10.9 Gy, and 11.8 ± 10.8 Gy, respectively. The mean increase in V100 was 7.2 ± 4.2%. All changes were statistically significant (P < 0.01). A negative correlation between pre-ablation tumor volume and D50, average dose, and V100 was identified (ρ < - 0.5, P < 0.05) suggesting that adjuvant radiofrequency ablation may be less beneficial to patients with large tumor burdens. CONCLUSIONS: This study has demonstrated that adjuvant 90Y PET/CT-guided radiofrequency ablation may improve tumor absorbed-dose metrics. These data may justify a prospective clinical trial to further evaluate this hybrid approach.

4.
J Vasc Interv Radiol ; 27(10): 1509-17, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27492867

RESUMEN

PURPOSE: To evaluate feasibility of left gastric artery (LGA) yttrium-90 ((90)Y) radioembolization as potential treatment for obesity in a porcine model. MATERIALS AND METHODS: This study included 8 young female pigs (12-13 weeks, 21.8-28.1 kg). Six animals received infusions of (90)Y resin microspheres (46.3-105.1 MBq) into the main LGA and the gastric artery arising from the splenic artery. Animal weight and serum ghrelin were measured before treatment and weekly thereafter. Animals were euthanized 69-74 days after treatment, and histologic analyses of mucosal integrity and ghrelin immunoreactive cell density were performed. RESULTS: Superficial mucosal ulcerations < 3.0 cm(2) were noted in 5 of 6 treated animals. Ghrelin immunoreactive cell density was significantly lower in treated versus untreated animals in the stomach fundus (13.5 vs 34.8, P < .05) and stomach body (11.2 vs 19.8, P < .05). Treated animals gained less weight than untreated animals over the study duration (40.2 kg ± 5.4 vs 54.7 kg ± 6.5, P = .053). Average fundic parietal area (165 cm(2) vs 282 cm(2), P = .067) and average stomach weight (297.2 g vs 397.0 g, P = .067) were decreased in treated versus untreated animals. Trichrome staining revealed significantly more fibrosis in treatment animals compared with control animals (13.0 vs 8.6, P < .05). No significant differences were identified in plasma ghrelin concentrations (P = .24). CONCLUSIONS: LGA (90)Y radioembolization is promising as a potential treatment for obesity. A larger preclinical study is needed to evaluate the safety and efficacy of this procedure further.


Asunto(s)
Arterias , Embolización Terapéutica/métodos , Obesidad/terapia , Radiofármacos/administración & dosificación , Estómago/irrigación sanguínea , Radioisótopos de Itrio/administración & dosificación , Animales , Biomarcadores/sangre , Estudios de Factibilidad , Femenino , Fibrosis , Mucosa Gástrica/metabolismo , Ghrelina/sangre , Infusiones Intraarteriales , Modelos Animales , Obesidad/sangre , Obesidad/fisiopatología , Proyectos Piloto , Estómago/patología , Sus scrofa , Factores de Tiempo , Pérdida de Peso
5.
J Nucl Med ; 57(12): 1957-1963, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27390155

RESUMEN

In 90Y radioembolization, nontarget embolization to the stomach or small bowel can result in gastrointestinal injury, a rare but difficult to manage clinical complication. However, dosimetric thresholds for toxicity to these tissues from radioembolization have never been evaluated in a controlled setting. We performed an analysis of the effect of 90Y radioembolization in a porcine model at different absorbed-dose endpoints. METHODS: Six female pigs underwent transfemoral angiography and infusion of 90Y-resin microspheres into arteries supplying part of the gastric wall. Esophagogastroduodenoscopy was performed after 4 wk to assess interim gastrointestinal health. Animals were monitored for side effects for 9 wk after 90Y infusion, after which they were euthanized and their upper gastrointestinal tracts were excised for analysis. Histologic sections were used to map microsphere location, and a microdosimetric evaluation was performed to determine the absorbed-dose profile within the gastrointestinal wall. RESULTS: 90Y radioembolization dosages from 46.3 to 105.1 MBq were infused, resulting in average absorbed doses of between 35.5 and 91.9 Gy to the gastric wall. No animal exhibited any signs of pain or gastrointestinal distress through the duration of the study. Excised tissue showed 1-2 small (<3.0 cm2) healed or healing superficial gastric lesions in 5 of 6 animals. Histologic analysis demonstrated that lesion location was superficial to areas of abnormally high microsphere deposition. An analysis of microsphere deposition patterns within the gastrointestinal wall indicated a high preference for submucosal deposition. Dosimetric evaluation at the luminal mucosa performed on the basis of microscopic microsphere distribution confirmed that 90Y dosimetry techniques conventionally used in hepatic dosimetry provide a first-order estimate of absorbed dose. CONCLUSION: The upper gastrointestinal tract may be less sensitive to 90Y radioembolization than previously thought. Lack of charged-particle equilibrium at the luminal mucosa may contribute to decreased toxicity of 90Y radioembolization compared with external-beam radiation therapy in gastrointestinal tissue. Clinical examples of injury from 90Y nontarget embolization have likely resulted from relatively large 90Y activities being deposited in small tissue volumes, resulting in absorbed doses in excess of 100 Gy.


Asunto(s)
Embolización Terapéutica/efectos adversos , Tracto Gastrointestinal Superior/citología , Tracto Gastrointestinal Superior/efectos de la radiación , Radioisótopos de Itrio/efectos adversos , Animales , Femenino , Radiometría , Dosificación Radioterapéutica , Porcinos , Radioisótopos de Itrio/uso terapéutico
6.
J Nucl Med ; 57(7): 1020-6, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26912424

RESUMEN

UNLABELLED: Differences in maximum tolerable absorbed dose to normal liver between (90)Y radioembolization and external-beam radiation therapy have been explained by citing differences in absorbed-dose heterogeneity at the microscopic level. We investigated microscopic absorbed-dose heterogeneity in radioembolization as a function of the number of microspheres per unit volume in tumor. The goal was to determine what effect the number of microspheres may have, if any, on tumor control in (90)Y radioembolization. METHODS: (90)Y PET/CT data were combined with microscopic probability-density functions describing microsphere clustering to provide realistic simulation using Monte Carlo modeling on both a macroscopic and a microscopic level. A complete microdosimetric analysis using 100-µm voxels was performed on the basis of (90)Y PET/CT data from 19 tumors treated using radioembolization. Simulations were performed with average tumor microsphere-number densities from 200 to 70,000 spheres/mL. Monte Carlo simulations of each tumor and number density were repeated 20 times to establish SE. A 2-way balanced ANOVA was used to determine whether differences in microsphere-number density affected common tumor-dose metrics. RESULTS: Decreasing the microsphere-number density resulted in a decrease in D70, the minimum dose to 70% of the tumor. The slope of the dose-volume histogram also decreased with decreasing microsphere-number density in all tumors. Compared with a density of 50,000 spheres/mL, decreases in D70 were statistically significant below 20,000 spheres/mL. However, these differences are unlikely to have clinical significance until the density decreases to below 5,000 spheres/mL. Although D70 was decreased at a low microsphere-number density, one can compensate for decreases by an increase in the average tumor-absorbed dose, that is, by increasing the radioembolization treatment dose. CONCLUSION: Differences in microsphere-number density may have an effect on microscopic tumor absorbed-dose inhomogeneity. These results begin to explain differences in treatment planning strategies between glass and resin radioembolization devices.


Asunto(s)
Embolización Terapéutica/métodos , Neoplasias Hepáticas/radioterapia , Radiofármacos/administración & dosificación , Radioisótopos de Itrio/administración & dosificación , Algoritmos , Relación Dosis-Respuesta en la Radiación , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/metabolismo , Microesferas , Método de Montecarlo , Tomografía de Emisión de Positrones , Radiofármacos/farmacocinética , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioisótopos de Itrio/farmacocinética
7.
Ann Transl Med ; 3(5): 69, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25992368

RESUMEN

Techniques and approaches of spinal fusion have considerably evolved since their first description in the early 1900s. The incorporation of pedicle screw constructs into lumbosacral spine surgery is among the most significant advances in the field, offering immediate stability and decreased rates of pseudarthrosis compared to previously described methods. However, early studies describing pedicle screw fixation and numerous studies thereafter have demonstrated clinically significant sequelae of inaccurate surgical fusion hardware placement. A number of image guidance systems have been developed to reduce morbidity from hardware malposition in increasingly complex spine surgeries. Advanced image guidance systems such as intraoperative stereotaxis improve the accuracy of pedicle screw placement using a variety of surgical approaches, however their clinical indications and clinical impact remain debated. Beginning with intraoperative fluoroscopy, this article describes the evolution of image guided lumbosacral spinal fusion, emphasizing two-dimensional (2D) and three-dimensional (3D) navigational methods.

8.
Acad Radiol ; 22(5): 668-73, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25863793

RESUMEN

RATIONALE AND OBJECTIVES: Fluoroscopically guided lumbar puncture (FGLP) is a commonly performed procedure with increased success rates relative to bedside technique. However, FGLP also exposes both patient and staff to ionizing radiation. The purpose of this study was to determine if the use of a simulation-based FGLP training program using an original, inexpensive lumbar spine phantom could improve operator confidence and efficiency, while also reducing patient dose. MATERIALS AND METHODS: A didactic and simulation-based FGLP curriculum was designed, including a 1-hour lecture and hands-on training with a lumbar spine phantom prototype developed at our institution. Six incoming post-graduate year 2 (PGY-2) radiology residents completed a short survey before taking the course, and each resident practiced 20 simulated FGLPs using the phantom before their first clinical procedure. Data from the 114 lumbar punctures (LPs) performed by the six trained residents (prospective cohort) were compared to data from 514 LPs performed by 17 residents who did not receive simulation-based training (retrospective cohort). Fluoroscopy time (FT), FGLP success rate, and indication were compared. RESULTS: There was a statistically significant reduction in average FT for the 114 procedures performed by the prospective study cohort compared to the 514 procedures performed by the retrospective cohort. This held true for all procedures in aggregate, LPs for myelography, and all procedures performed for a diagnostic indication. Aggregate FT for the prospective group (0.87 ± 0.68 minutes) was significantly lower compared to the retrospective group (1.09 ± 0.65 minutes) and resulted in a 25% reduction in average FT (P = .002). There was no statistically significant difference in the number of failed FGLPs between the two groups. CONCLUSIONS: Our simulation-based FGLP curriculum resulted in improved operator confidence and reduced FT. These changes suggest that resident procedure efficiency was improved, whereas patient dose was reduced. The FGLP training program was implemented by radiology residents and required a minimal investment of time and resources. The LP spine phantom used during training was inexpensive, durable, and effective. In addition, the phantom is compatible with multiple modalities including fluoroscopy, computed tomography, and ultrasound and could be easily adapted to other applications such as facet injections or joint arthrograms.


Asunto(s)
Curriculum , Educación de Postgrado en Medicina , Fluoroscopía , Radiología Intervencionista/educación , Punción Espinal , Evaluación Educacional , Humanos , Fantasmas de Imagen , Dosis de Radiación , Estudios Retrospectivos
9.
J Vasc Interv Radiol ; 26(5): 660-9, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25801854

RESUMEN

PURPOSE: To determine if there are differences in hepatic distribution of embolic particles following infusion with a standard end-hole catheter versus an antireflux microcatheter. MATERIALS AND METHODS: This prospective study included nine patients (age, 48-86 y) enrolled for treatment of hepatocellular carcinoma (n = 6), liver-dominant metastatic disease (n = 2), or intrahepatic cholangiocarcinoma (n = 1) with resin yttrium-90 ((90)Y) microspheres. Before (90)Y treatment, each patient received two same-day sequential lobar infusions of technetium 99m ((99m)Tc) macroaggregated albumin (MAA) via a conventional end-hole catheter and an antireflux microcatheter positioned at the same location. Differences in technetium 99m-MAA distribution within tumor and nontarget sites were evaluated by single-photon emission computed tomography (SPECT) on a qualitative and semiquantitative basis. The antireflux microcatheter was used for the ensuing (90)Y treatment, with posttreatment (90)Y positron emission tomography/computed tomography to assess distribution of (90)Y microspheres. RESULTS: Decreases in hepatic nontarget embolization were found in all patients when the antireflux catheter was used. These decreases ranged from a factor of 0.11 to a factor of 0.76 (mean, 0.42; σ = 0.19), representing a 24%-89% reduction. Increased tumor deposition was also noted in all patients, ranging from a factor of 1.33 to a factor of 1.90 (mean, 1.68; σ = 0.20), representing a relative increase of 33%-90%. Both findings were statistically significant (P < .05). CONCLUSIONS: Although this pilot study identified differences in the downstream distribution of embolic particles when the antireflux catheter was used, further investigation is needed to determine if these findings are reproducible in a larger patient cohort and, if so, whether they are associated with any clinical impact.


Asunto(s)
Catéteres , Embolización Terapéutica/métodos , Material Particulado/análisis , Anciano , Anciano de 80 o más Años , Humanos , Hígado/química , Persona de Mediana Edad , Proyectos Piloto , Tomografía de Emisión de Positrones , Estudios Prospectivos , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Tomografía Computarizada de Emisión de Fotón Único , Radioisótopos de Itrio
10.
Simul Healthc ; 10(1): 54-8, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25574867

RESUMEN

INTRODUCTION: This report describes the creation process for an inexpensive, durable, lumbar spine phantom for use in fluoroscopically guided lumbar puncture (LP) training. METHODS: The LP phantom prototype was made from a polyvinyl chloride lumbar spine model embedded in a translucent rectangular block of commercially available thermoplastic polymer gel. Radiology residents with limited previous experience performing LP used the phantom for 20 simulated procedures to gain confidence before starting patient procedures. The residents completed surveys detailing their experiences with the phantom. RESULTS: Quantitative evaluation of the phantom using fluoroscopy and computed tomography suggested good physical agreement with human anatomy. Six board-certified radiologists viewed the phantom under live fluoroscopy and indicated that the phantom represented human anatomy with sufficient accuracy. Furthermore, surveys from resident trainees indicated that the thermoplastic tissue substitute simulated the texture and resistance of human soft tissue reasonably well for the purposes of clinical training. The total material cost of the LP phantom prototype was approximately US $148.00. CONCLUSIONS: This novel spine phantom can be produced with relatively low cost when compared with similar commercially available products. The phantom offers reasonable visual and tactile agreement to human anatomy and may be useful for improving the confidence of physician trainees. The LP phantom is durable and can easily be repaired by reheating the polymer tissue substitute.


Asunto(s)
Educación Médica/métodos , Maniquíes , Modelos Biológicos , Punción Espinal/métodos , Fluoroscopía , Humanos
SELECCIÓN DE REFERENCIAS