Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Radiol Med ; 2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39256298

RESUMEN

PURPOSE: The objective of this study was to investigate the role of myocardial perfusion imaging (MPI) stress tests using stress cardiac magnetic resonance (sCMR) and single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) in non-cardiac surgery (NCS) pre-operatory management. MATERIALS AND METHODS: This monocentric retrospective study enrolled patients with coronary artery disease or a minimum of two cardiovascular risk factors undergoing intermediate-to-high-risk non-cardiac surgeries. The primary composite endpoint comprised cardiac death, cardiogenic shock, acute coronary syndromes (ACS), and cardiogenic pulmonary edema occurring within 30 days after surgery, while the secondary endpoint was ACS. RESULTS: A total of 1590 patients were enrolled; among them, 669 underwent a MPI stress test strategy (sCMR: 287, SPECT-MPI: 382). The incidence of 30-day cardiac events was lower in the stress-tested group compared to the non-stress-tested group (1.2% vs. 3.4%; p 0.006). Adopting a stress test strategy showed a significant reduction in the risk of the composite endpoint (OR: 0.33, 95% CI: 0.15-0.76, p 0.009) and ACS (OR: 0.41, 95% CI: 0.17-0.98, p 0.046) at multivariable analysis, with similar cardiac events rate between stress CMR and SPECT (1.1% vs. 1.3%, p 0.756). Stress CMR showed a greater accuracy to predict coronary artery revascularizations (sCMR c-statistic: 0.95, ischemic cut-point: 5.5%; SPECT c-statistic: 0.85, ischemic cut-point: 7.5%). CONCLUSION: Stress test strategy is related to a lower occurrence of cardiac events in high-risk patients scheduled for intermediate-to-high-risk non-cardiac surgeries. Both sCMR and SPECT-MPI comparably reduce the likelihood of cardiac complications, albeit sCMR offers greater accuracy in predicting coronary artery revascularization.

2.
J Cardiovasc Magn Reson ; 26(2): 101056, 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38971502

RESUMEN

BACKGROUND: The presence of mitral annulus disjunction (MAD) has been considered a high-risk feature for sudden cardiac death based on selected study populations. We aimed to assess the prevalence of MAD in consecutive patients undergoing clinically indicated cardiovascular magnetic resonance (CMR), its association with ventricular arrhythmias, mitral valve prolapse (MVP), and other CMR features. METHODS: This single-center retrospective study included consecutive patients referred to CMR at our institution between June 2021 and November 2021. MAD was defined as a ≥1 mm displacement between the left atrial wall-mitral valve leaflet junction and the left ventricular wall during end-systole. MAD extent was defined as the maximum longitudinal displacement. Associates of MAD were evaluated at univariable and multivariable regression analysis. The study endpoint, a composite of (aborted) sudden cardiac death, unexplained syncope, and sustained ventricular tachycardia, was evaluated at a 12-month follow-up. RESULTS: Four hundred and forty-one patients 55 ± 18 years, 267/441 (61%) males) were included, and 29/441 (7%) had MVP. The prevalence of MAD ≥1 mm, 4 mm, and 6 mm was 214/441 (49%), 63/441 (14%), and 15/441 (3%), respectively. Patients with MVP showed a higher prevalence of MAD greater than 1 mm (26/29 (90%) vs 118/412 (46%)); p < 0.001), 4 mm (14/29 (48%) vs 49/412 (12%)); p < 0.001), and 6 mm (3/29 (10%) vs 12/412 (3%)); p = 0.03), and a greater MAD extent (4.2 mm, 3.0-5.7 mm vs 2.8 mm, 1.9-4.0 mm; p < 0.001) compared to patients without MVP. MVP was the only morpho-functional abnormality associated with MAD at multivariable analysis (p < 0.001). A high burden of ventricular ectopic beats at baseline Holter-electrocardiogram was associated with MAD ≥4 mm and MAD extent (p < 0.05). The presence of MAD ≥1 mm (0.9% vs 1.8%; p = 0.46), MAD ≥4 mm (1.6% vs 1.3%; p = 0.87), or MVP (3.5% vs 1.2%; p = 0.32) were not associated with the study endpoint, whereas patients with MAD ≥6 mm showed a trend toward a higher likelihood of the study endpoint (6.7% vs 1.2%; p = 0.07). CONCLUSION: MAD of limited severity was common in consecutive patients undergoing CMR. Patients with MVP showed higher prevalence and greater extent of MAD. Extended MAD was rarer and showed association with ventricular arrhythmias at baseline. The mid-term prognosis of MAD seems benign; however, prospective studies are warranted to search for potential "malignant MAD extents" to improve patients' risk stratification.

3.
Am Heart J ; 275: 128-137, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38838970

RESUMEN

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) on major endpoints after transcatheter aortic valve replacement (TAVR) is controversial and the effects on progression of heart damage are poorly investigated. Therefore, our study aims to evaluate the prevalence and predictors of PPM in a "real world" cohort of patients at intermediate and low surgical risk, its impact on mortality and the clinical-echocardiographic progression of heart damage. METHODS: 963 patients who underwent TAVR procedure between 2017 and 2021, from the RECOVERY-TAVR international multicenter observational registry, were included in this analysis. Multiparametric echocardiographic data of these patients were analyzed at 1-year follow-up (FU). Clinical and echocardiographic features were stratified by presence of PPM and PPM severity, as per the most current international recommendations, using VARC-3 criteria. RESULTS: 18% of patients developed post-TAVR. PPM, and 7.7% of the whole cohort had severe PPM. At baseline, 50.3% of patients with PPM were male (vs 46.2% in the cohort without PPM, P = .33), aged 82 (IQR 79-85y) years vs 82 (IQR 78-86 P = .46), and 55.6% had Balloon-Expandable valves implanted (vs 46.8% of patients without PPM, P = .04); they had smaller left ventricular outflow tract (LVOT) diameter (20 mm, IQR 19-21 vs 20 mm, IQR 20-22, P = .02), reduced SVi (34.2 vs 38 mL/m2, P < .01) and transaortic flow rate (190.6 vs 211 mL/s, P < .01). At predischarge FU patients with PPM had more paravalvular aortic regurgitation (moderate-severe AR 15.8% vs 9.2%, P < .01). At 1-year FU, maladaptive alterations of left ventricular parameters were found in patients with PPM, with a significant increase in end-systolic diameter (33 mm vs 28 mm, P = .03) and a significant increase in left ventricle end systolic indexed volume in those with moderate and severe PPM (52 IQR 42-64 and 52, IQR 41-64 vs 44 IQR 35-59 in those without, P = .02)). No evidence of a significant impact of PPM on overall (P = .71) and CV (P = .70) mortality was observed. Patients with moderate/severe PPM had worse NYHA functional class at 1 year (NYHA III-IV 13% vs 7.8%, P = .03). Prosthesis size≤23 mm (OR 11.6, 1.68-80.1) was an independent predictor of PPM, while SVi (OR 0.87, 0.83-0.91, P < .001) and LVOT diameter (OR 0.79, 0.65-0.95, P = .01) had protective effect. CONCLUSIONS: PPM was observed in 18% of patients undergoing TAVR. Echocardiographic evaluations demonstrated a PPM-related pattern of early ventricular maladaptive alterations, possibly precursor to a reduction in cardiac function, associated with a significant deterioration in NYHA class at 1 year. These findings emphasize the importance of prevention of PPM of any grade in patients undergoing TAVR procedure, especially in populations at risk.


Asunto(s)
Estenosis de la Válvula Aórtica , Ecocardiografía , Prótesis Valvulares Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Anciano de 80 o más Años , Prótesis Valvulares Cardíacas/efectos adversos , Ecocardiografía/métodos , Estenosis de la Válvula Aórtica/cirugía , Anciano , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Ajuste de Prótesis
5.
JACC Case Rep ; 29(3): 102191, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38361557

RESUMEN

An 81-year-old woman presented with acute pulmonary edema. Echocardiography revealed severe functional mitral regurgitation, the mechanism of which was unusual. An atypical bileaflet tethering caused by disharmonic annular remodeling, concomitant aortic dilatation, and reduced aorto-mitral angle without left ventricular dysfunction or dilatation was found. A transcatheter edge-to-edge repair was nonetheless successfully performed.

7.
Artículo en Inglés | MEDLINE | ID: mdl-37931791

RESUMEN

Percutaneous closure of a patent foramen ovale (PFO), a common variation of interatrial septum anatomy, is a commonly performed procedure in the catheterization laboratory to reduce the risk of recurrent stroke in selected patients and to treat other PFO-related syndromes. In the last twenty years, disc-based devices have represented the armamentarium of the interventional cardiologist; recently, suture-based devices have become an attractive alternative, despite limited data regarding their long-term performance. The present review gives an overview of the current evidence regarding suture-based PFO closure, the device's characteristics, the echocardiographic evaluation of the PFO anatomy, and recommendations for patient selection. A detailed procedural guide is then provided, and potential complications and future developments in the field are discussed.

8.
J Cardiovasc Echogr ; 33(1): 1-9, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37426716

RESUMEN

Background: The Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI) conducted a national survey to understand better how different echocardiographic modalities are used and accessed in Italy. Methods: We analyzed echocardiography laboratory activities over a month (November 2022). Data were retrieved via an electronic survey based on a structured questionnaire, uploaded on the SIECVI website. Results: Data were obtained from 228 echocardiographic laboratories: 112 centers (49%) in the northern, 43 centers (19%) in the central, and 73 (32%) in the southern regions. During the month of observation, we collected 101,050 transthoracic echocardiography (TTE) examinations performed in all centers. As concern other modalities there were performed 5497 transesophageal echocardiography (TEE) examinations in 161/228 centers (71%); 4057 stress echocardiography (SE) examinations in 179/228 centers (79%); and examinations with ultrasound contrast agents (UCAs) in 151/228 centers (66%). We did not find significant regional variations between the different modalities. The usage of picture archiving and communication system (PACS) was significantly higher in the northern (84%) versus central (49%) and southern (45%) centers (P < 0.001). Lung ultrasound (LUS) was performed in 154 centers (66%), without difference between cardiology and noncardiology centers. The evaluation of left ventricular (LV) ejection fraction was evaluated mainly using the qualitative method in 223 centers (94%), occasionally with the Simpson method in 193 centers (85%), and with selective use of the three-dimensional (3D) method in only 23 centers (10%). 3D TTE was present in 137 centers (70%), and 3D TEE in all centers where TEE was done (71%). The assessment of LV diastolic function was done routinely in 80% of the centers. Right ventricular function was evaluated using tricuspid annular plane systolic excursion in all centers, using tricuspid valve annular systolic velocity by tissue Doppler imaging in 53% of the centers, and using fractional area change in 33% of the centers. When we divided into cardiology (179, 78%) and noncardiology (49, 22%) centers, we found significant differences in the SE (93% vs. 26%, P < 0.001), TEE (85% vs. 18%), UCA (67% vs. 43%, P < 0001), and STE (87% vs. 20%, P < 0.001). The incidence of LUS evaluation was similar between the cardiology and noncardiology centers (69% vs. 61%, P = NS). Conclusions: This nationwide survey demonstrated that digital infrastructures and advanced echocardiography modalities, such as 3D and STE, are widely available in Italy with a notable diffuse uptake of LUS in the core TTE examination, a suboptimal diffusion of PACS recording, and conservative use of UCA, 3D, and strain. There are significant differences between northern and central-southern regions and echocardiographic laboratories that pertain to the cardiac unit. This inhomogeneous distribution of technology represents one of the main issues that must be solved to standardize the practice of echocardiography.

9.
J Cardiovasc Dev Dis ; 10(6)2023 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-37367391

RESUMEN

Cardiac magnetic resonance (CMR) has been recently implemented in clinical practice to refine the daunting task of establishing the risk of sudden cardiac death (SCD) in patients with hypertrophic cardiomyopathy (HCM). We present an exemplificative case highlighting the practical clinical utility of this imaging modality in a 24-year-old man newly diagnosed with an apical HCM. CMR was essential in unmasking a high risk of SCD, which appeared low-intermediate after traditional risk assessment. A discussion examines the essential role of CMR in guiding the patient's therapy and underlines the added value of CMR, including novel and potential CMR parameters, compared to traditional imaging assessment for SCD risk stratification.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA