1.
Rev Sci Instrum ; 91(12): 123502, 2020 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-33380006

RESUMEN

Sentinel is a 16-channel, filtered x-ray diode array spectrometer that has been developed to measure ∼1 keV-20 keV x-ray emission generated by the National Ignition Facility (NIF) laser. Unlike the large, fixed-port versions of this diagnostic that currently exist on the NIF (known as Dante), Sentinel is a Diagnostic Instrument Manipulator compatible such that it can be fielded along the polar or equatorial lines-of-sight-an essential new capability for characterizing the often anisotropic x-ray emission from laser-driven sources. We present the diagnostic design along with preliminary diode calibrations and performance results. The novel, small-form-factor x-ray diode design allows for ≳5×-25× increased channel areal density over that of Dante, simultaneously enabling improved diagnostic robustness and fidelity of spectral reconstructions. While the Sentinel diagnostic is anticipated to improve line-of-sight spectral characterization of x-ray sources for a wide variety of programs on the NIF, the compact and portable design is also attractive to small- and mid-scale facilities with limited diagnostic real estate.

2.
Pediatr Cardiol ; 39(7): 1484-1488, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29948024

RESUMEN

Up to 10% of Fontan patients require pacemakers; an epicardial approach has historically been used. A transvenous approach can be used but carries risk of Fontan obstruction, thromboembolism, and can be technically challenging. The safety and efficacy of these approaches is not well described. The aim of this study was to compare epicardial and transvenous pacemaker outcomes in Fontan patients, specifically, device performance and adverse event rate. A retrospective review was performed on Fontan pacemaker patients followed at a single institution. Thirty-one Fontan pacemaker patients were identified between 1985 and 2017. Twenty-six had an epicardial system, five transvenous, and three converted from epicardial to transvenous. Average atrial lead sensing at placement was 3.23 versus 2.35 mV (p = 0.52) for epicardial and transvenous leads, respectively. Median atrial and ventricular lead longevity was 86.4 versus 98.8 months (p = 0.56) and 73.2 versus 140 months (p = 0.3) with generator longevity of 65.5 versus 73.9 (p = 0.16) months for epicardial versus transvenous systems, respectively. One major complication occurred in a transvenous patient, and two minor complications occurred in epicardial patients. All transvenous patients received warfarin except one, who converted to dabigatran. Epicardial patients received aspirin (n = 20), warfarin (n = 3) or a warfarin/aspirin combination (n = 3). No thromboembolic events occurred. System revision was required in 13 epicardial and 5 transvenous patients. There were two deaths, none related to the pacemaker system. Transvenous pacemakers can be utilized with equal efficacy compared to epicardial pacemakers with trends toward longer lead longevity in transvenous pacemaker systems.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Procedimiento de Fontan/métodos , Marcapaso Artificial/efectos adversos , Adulto , Estimulación Cardíaca Artificial/efectos adversos , Falla de Equipo/estadística & datos numéricos , Femenino , Procedimiento de Fontan/efectos adversos , Atrios Cardíacos/fisiopatología , Cardiopatías Congénitas/cirugía , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Pericardio/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos
3.
Rev Sci Instrum ; 87(11): 11D421, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910608

RESUMEN

Our team has developed an experimental platform to evaluate the x-ray-generated stress and impulse in materials. Experimental activities include x-ray source development, design of the sample mounting hardware and sensors interfaced to the National Ignition Facility's diagnostics insertion system, and system integration into the facility. This paper focuses on the X-ray Transport and Radiation Response Assessment (XTRRA) test cassettes built for these experiments. The test cassette is designed to position six samples at three predetermined distances from the source, each known to within ±1% accuracy. Built-in calorimeters give in situ measurements of the x-ray environment along the sample lines of sight. The measured accuracy of sample responses as well as planned modifications to the XTRRA cassette is discussed.

4.
Rev Sci Instrum ; 87(2): 023511, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26931853

RESUMEN

We describe an experimental method to measure the gate profile of an x-ray framing camera and to determine several important functional parameters: relative gain (between strips), relative gain droop (within each strip), gate propagation velocity, gate width, and actual inter-strip timing. Several of these parameters cannot be measured accurately by any other technique. This method is then used to document cross talk-induced gain variations and artifacts created by radiation that arrives before the framing camera is actively amplifying x-rays. Electromagnetic cross talk can cause relative gains to vary significantly as inter-strip timing is varied. This imposes a stringent requirement for gain calibration. If radiation arrives before a framing camera is triggered, it can cause an artifact that manifests as a high-intensity, spatially varying background signal. We have developed a device that can be added to the framing camera head to prevent these artifacts.

5.
Rev Sci Instrum ; 85(9): 095119, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25273784

RESUMEN

The energy partitioning energy coupling experiments at the National Ignition Facility (NIF) have been designed to measure simultaneously the coupling of energy from a laser-driven target into both ground shock and air blast overpressure to nearby media. The source target for the experiment is positioned at a known height above the ground-surface simulant and is heated by four beams from the NIF. The resulting target energy density and specific energy are equal to those of a low-yield nuclear device. The ground-shock stress waves and atmospheric overpressure waveforms that result in our test system are hydrodynamically scaled analogs of full-scale seismic and air blast phenomena. This report summarizes the development of the platform, the simulations, and calculations that underpin the physics measurements that are being made, and finally the data that were measured. Agreement between the data and simulation of the order of a factor of two to three is seen for air blast quantities such as peak overpressure. Historical underground test data for seismic phenomena measured sensor displacements; we measure the stresses generated in our ground-surrogate medium. We find factors-of-a-few agreement between our measured peak stresses and predictions with modern geophysical computer codes.

6.
Rev Sci Instrum ; 83(10): 10D729, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126901

RESUMEN

Electromagnetic interference (EMI) is an ever-present challenge at laser facilities such as the National Ignition Facility (NIF). The major source of EMI at such facilities is laser-target interaction that can generate intense electromagnetic fields within, and outside of, the laser target chamber. In addition, the diagnostics themselves can be a source of EMI, even interfering with themselves. In this paper we describe EMI generated by ARIANE and DIXI, present measurements, and discuss effects of the diagnostic-generated EMI on ARIANE's CCD and on a PMT nearby DIXI. Finally we present some of the efforts we have made to mitigate the effects of diagnostic-generated EMI on NIF diagnostics.

7.
Rev Sci Instrum ; 83(10): 10E135, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126956

RESUMEN

We present evidence that electromagnetic crosstalk between independent strips in gated x-ray framing cameras can affect relative gains by up to an order of magnitude and gate arrival times up to tens of picoseconds when strip separation times are less then ∼1 ns. Crosstalk is observed by multiple methods, and it is confirmed by direct measurements of voltage on the active surface of the detector and also by indirect voltage monitors in routine operation. The voltage measurements confirm that crosstalk is produced not only in the active regions of the microchannel plate, but also along the entire input path of the voltage pulses.

8.
Rev Sci Instrum ; 83(12): 125105, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23278024

RESUMEN

An x-ray streak camera platform has been characterized and implemented for use at the National Ignition Facility. The camera has been modified to meet the experiment requirements of the National Ignition Campaign and to perform reliably in conditions that produce high electromagnetic interference. A train of temporal ultra-violet timing markers has been added to the diagnostic in order to calibrate the temporal axis of the instrument and the detector efficiency of the streak camera was improved by using a CsI photocathode. The performance of the streak camera has been characterized and is summarized in this paper. The detector efficiency and cathode measurements are also presented.

9.
J Evol Biol ; 24(10): 2217-29, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21726331

RESUMEN

Ecological speciation studies have more thoroughly addressed premating than postmating reproductive isolation. This study examines multiple postmating barriers between host forms of Neochlamisus bebbianae leaf beetles that specialize on Acer and Salix trees. We demonstrate cryptic isolation and reduced hybrid fitness via controlled matings of these host forms. These findings reveal host-associated postmating isolation, although a nonecological, 'intrinsic' basis for these patterns cannot be ruled out. Host preference and performance results among cross types further suggest sex-linked maternal effects on these traits, whereas family effects indicate their genetic basis and associated variation. Genes of major effect appear to influence these traits. Together with previous findings of premating isolation and adaptive differentiation in sympatry, our results meet many assumptions of 'speciation with gene flow' models. Here, such gene flow is likely asymmetric, with consequences for the dynamics of future ecological divergence and potential ecological speciation of these host forms.


Asunto(s)
Escarabajos/genética , Variación Genética , Conducta Sexual Animal , Aislamiento Social , Acer , Animales , Escarabajos/fisiología , Femenino , Flujo Génico , Especiación Genética , Vigor Híbrido , Masculino , Salix
10.
Support Care Cancer ; 18(8): 1061-79, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20333412

RESUMEN

PURPOSE: This systematic review aimed to assess the literature for management strategies and economic impact of salivary gland hypofunction and xerostomia induced by cancer therapies and to determine the quality of evidence-based management recommendations. METHODS: The electronic databases of MEDLINE/PubMed and EMBASE were searched for articles published in English since the 1989 NIH Development Consensus Conference on the Oral Complications of Cancer Therapies until 2008 inclusive. For each article, two independent reviewers extracted information regarding study design, study population, interventions, outcome measures, results, and conclusions. RESULTS: Seventy-two interventional studies met the inclusion criteria. In addition, 49 intensity-modulated radiation therapy (IMRT) studies were included as a management strategy aiming for less salivary gland damage. Management guideline recommendations were drawn up for IMRT, amifostine, muscarinic agonist stimulation, oral mucosal lubricants, acupuncture, and submandibular gland transfer. CONCLUSIONS: There is evidence that salivary gland hypofunction and xerostomia induced by cancer therapies can be prevented or symptoms be minimized to some degree, depending on the type of cancer treatment. Management guideline recommendations are provided for IMRT, amifostine, muscarinic agonist stimulation, oral mucosal lubricants, acupuncture, and submandibular gland transfer. Fields of sparse literature identified included effects of gustatory and masticatory stimulation, specific oral mucosal lubricant formulas, submandibular gland transfer, acupuncture, hyperbaric oxygen treatment, management strategies in pediatric cancer populations, and the economic consequences of salivary gland hypofunction and xerostomia.


Asunto(s)
Neoplasias/terapia , Enfermedades de las Glándulas Salivales/etiología , Xerostomía/etiología , Humanos , Guías de Práctica Clínica como Asunto , Radioterapia de Intensidad Modulada/efectos adversos , Radioterapia de Intensidad Modulada/métodos , Enfermedades de las Glándulas Salivales/economía , Enfermedades de las Glándulas Salivales/terapia , Xerostomía/economía , Xerostomía/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA