Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Appl Behav Anal ; 34(1): 69-72, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11317990

RESUMEN

Differentially higher rates of aggression in treatment sessions occurred in the presence of two staff members who had previously worked with the participant at another facility. Adding an edible reinforcer for compliance and the absence of aggression in sessions conducted by these two staff members decreased aggression to rates similar to those obtained with less familiar therapists. Results suggest that embedding positive reinforcement within a demand context may reduce the aversiveness of therapists correlated with a history of demand situations.


Asunto(s)
Agresión/psicología , Trastorno Autístico/psicología , Terapia Conductista/métodos , Trastornos Mentales/etiología , Trastornos Mentales/terapia , Negativa del Paciente al Tratamiento , Adolescente , Conducta del Adolescente/psicología , Extinción Psicológica , Humanos , Masculino , Refuerzo en Psicología
2.
Proc (Bayl Univ Med Cent) ; 14(3): 239-40, 2001 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16369626
3.
Med Sci Sports Exerc ; 29(9): 1131-8, 1997 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-9309622

RESUMEN

Sudden cardiac death among high school athletes is a very infrequent though tragic occurrence. Despite widespread preparticipation screening for known causes of this event, the frequency has not changed. The ECG is an acknowledged sensitive screening tool for the common causes of sudden cardiac death in young athletes. The specificity of the ECG in this setting is believed to be relatively low in young athletes for which reason, in part, it is not used. We added an ECG to the usual preparticipation screening. An echocardiogram was performed when screening was abnormal. Outcome measures of serious or potentially serious cardiovascular abnormalities were defined by the 16th Bethesda Conference. These abnormalities either preclude sports participation or require further testing before approval for participation in sports can be considered. Over 3 yr, 5,615 male and female high school athletes were screened prospectively from 30 different high schools in northern Nevada. Outcome measures were detected in 22 athletes or one per 255. Cardiac history led to detection of outcome measures in 0 athletes, auscultation/inspection in 1/6,000 athletes, blood pressure measurement in 1/1,000 athletes, and the ECG in 1/350 athletes. Specificity was 97.8% for an abbreviated cardiac history and auscultation/inspection and 97.7% for ECG. Overall, the ECG was a much more effective screening tool than cardiac history and auscultation/inspection in detecting cardiovascular abnormalities requiring further tests before approval for participation in sports could be given. ECG and cardiovascular history/ausculation/inspection had similar specificity ECG was efficiently performed on large groups of high school athletes.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Tamizaje Masivo , Deportes , Adolescente , Adulto , Anomalías Cardiovasculares , Ecocardiografía , Electrocardiografía , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Anamnesis
4.
J Res Natl Inst Stand Technol ; 101(2): 133-140, 1996.
Artículo en Inglés | MEDLINE | ID: mdl-27805120

RESUMEN

We describe how the National Institute of Standards and Technology obtains a scale of absolute spectral response from 406 nm to 920 nm. This scale of absolute spectral response is based solely on detector measurements traceable to the NIST High Accuracy Cryogenic Radiometer (HACR). Silicon photodiode light-trapping detectors are used to transfer optical power measurements from the HACR to a monochromator-based facility where routine measurements are performed. The transfer also involves modeling the quantum efficiency (QE) of the silicon photodiode light-trapping detectors. We describe our planned quality system for these measurements that follows ANSI/NCSL Z540-1-1994. A summary of current NIST capabilities based on these measurements is also given.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...