Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biomimetics (Basel) ; 9(6)2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38921199

RESUMEN

Robotic control is a fundamental part of autonomous robots. Modular legged and climbing robots are complex machines made up of a variety of subsystems, ranging from a single robot with simple legs to a complex system composed of multiple legs (or modules) with computing power and sensitivity. Their complexity, which is increased by the fact of needing elements for climbing, makes a correct structure crucial to achieve a complete, robust, and versatile system during its operation. Control architectures for legged robots are distinguished from other software architectures because of the special needs of these systems. In this paper, we present an original classification of modular legged and climbing robots, a comprehensive review of the most important control architectures in robotics, focusing on the control of modular legged and climbing robots, and a comparison of their features. The control architecture comparison aims to provide the analytical tools necessary to make informed decisions tailored to the specific needs of your robotic applications. This article includes a review and classification of modular legged and climbing robots, breaking down each category separately.

2.
Heliyon ; 10(4): e26227, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38404866

RESUMEN

BACKGROUND AND OBJECTIVE: the use of 3D cameras for gait analysis has been highly questioned due to the low accuracy they have demonstrated in the past. The objective of the study presented in this paper is to improve the accuracy of the estimations made by robot-mounted 3D cameras in human gait analysis by applying a supervised learning stage. METHODS: the 3D camera was mounted in a mobile robot to obtain a longer walking distance. This study shows an improvement in detection of kinematic gait signals and gait descriptors by post-processing the raw estimations of the camera using artificial neural networks trained with the data obtained from a certified Vicon system. To achieve this, 37 healthy participants were recruited and data of 207 gait sequences were collected using an Orbbec Astra 3D camera. There are two basic possible approaches for training and both have been studied in order to see which one achieves a better result. The artificial neural network can be trained either to obtain more accurate kinematic gait signals or to improve the gait descriptors obtained after initial processing. The former seeks to improve the waveforms of kinematic gait signals by reducing the error and increasing the correlation with respect to the Vicon system. The second is a more direct approach, focusing on training the artificial neural networks using gait descriptors directly. RESULTS: the accuracy of the 3D camera to objectify human gait was measured before and after training. In both training approaches, a considerable improvement was observed. Kinematic gait signals showed lower errors and higher correlations with respect to the ground truth. The accuracy of the system to detect gait descriptors also showed a substantial improvement, mostly for kinematic descriptors rather than spatio-temporal. When comparing both training approaches, it was not possible to define which was the absolute best. CONCLUSIONS: supervised learning improves the accuracy of 3D cameras but the selection of the training approach will depend on the purpose of the study to be conducted. This study reveals the great potential of 3D cameras and encourages the research community to continue exploring their use in gait analysis.

3.
Sensors (Basel) ; 23(15)2023 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-37571727

RESUMEN

Three-dimensional (3D) cameras used for gait assessment obviate the need for bodily markers or sensors, making them particularly interesting for clinical applications. Due to their limited field of view, their application has predominantly focused on evaluating gait patterns within short walking distances. However, assessment of gait consistency requires testing over a longer walking distance. The aim of this study is to validate the accuracy for gait assessment of a previously developed method that determines walking spatiotemporal parameters and kinematics measured with a 3D camera mounted on a mobile robot base (ROBOGait). Walking parameters measured with this system were compared with measurements with Xsens IMUs. The experiments were performed on a non-linear corridor of approximately 50 m, resembling the environment of a conventional rehabilitation facility. Eleven individuals exhibiting normal motor function were recruited to walk and to simulate gait patterns representative of common neurological conditions: Cerebral Palsy, Multiple Sclerosis, and Cerebellar Ataxia. Generalized estimating equations were used to determine statistical differences between the measurement systems and between walking conditions. When comparing walking parameters between paired measures of the systems, significant differences were found for eight out of 18 descriptors: range of motion (ROM) of trunk and pelvis tilt, maximum knee flexion in loading response, knee position at toe-off, stride length, step time, cadence; and stance duration. When analyzing how ROBOGait can distinguish simulated pathological gait from physiological gait, a mean accuracy of 70.4%, a sensitivity of 49.3%, and a specificity of 74.4% were found when compared with the Xsens system. The most important gait abnormalities related to the clinical conditions were successfully detected by ROBOGait. The descriptors that best distinguished simulated pathological walking from normal walking in both systems were step width and stride length. This study underscores the promising potential of 3D cameras and encourages exploring their use in clinical gait analysis.


Asunto(s)
Marcha , Caminata , Humanos , Marcha/fisiología , Caminata/fisiología , Extremidad Inferior , Rodilla , Articulación de la Rodilla , Fenómenos Biomecánicos
4.
Biomimetics (Basel) ; 8(1)2022 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-36648797

RESUMEN

MoCLORA (Modular Climbing-and-Legged Robotic Organism Architecture) is a software framework for climbing bio-inspired robotic organisms composed of modular robots (legs). It is presented as a modular low-level architecture that coordinates the modules of an organism with any morphology, at the same time allowing exchanges between the physical robot and its digital twin. It includes the basic layers to control and coordinate all the elements, while allowing adding new higher-level components to improve the organism's behavior. It is focused on the control of both the body and the legs of the organism, allowing for position and velocity control of the whole robot. Similarly to insects, which are able to adapt to new situations after the variation on the capacity of any of their legs, MoCLORA allows the control of organisms composed of a variable number of modules, arranged in different ways, giving the overall system the versatility to tackle a wide range of tasks in very diverse environments. The article also presents ROMERIN, a modular climbing and legged robotic organism, and its digital twin, which allows the creation of different module arrangements for testing. MoCLORA has been tested and validated with both the physical robot and its digital twin.

5.
Sensors (Basel) ; 21(20)2021 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-34695999

RESUMEN

Mobile robotic platforms have made inroads in the rehabilitation area as gait assistance devices. They have rarely been used for human gait monitoring and analysis. The integration of mobile robots in this field offers the potential to develop multiple medical applications and achieve new discoveries. This study proposes the use of a mobile robotic platform based on depth cameras to perform the analysis of human gait in practical scenarios. The aim is to prove the validity of this robot and its applicability in clinical settings. The mechanical and software design of the system is presented, as well as the design of the controllers of the lane-keeping, person-following, and servoing systems. The accuracy of the system for the evaluation of joint kinematics and the main gait descriptors was validated by comparison with a Vicon-certified system. Some tests were performed in practical scenarios, where the effectiveness of the lane-keeping algorithm was evaluated. Clinical tests with patients with multiple sclerosis gave an initial impression of the applicability of the instrument in patients with abnormal walking patterns. The results demonstrate that the system can perform gait analysis with high accuracy. In the curved sections of the paths, the knee joint is affected by occlusion and the deviation of the person in the camera reference system. This issue was greatly improved by adjusting the servoing system and the following distance. The control strategy of this robot was specifically designed for the analysis of human gait from the frontal part of the participant, which allows one to capture the gait properly and represents one of the major contributions of this study in clinical practice.


Asunto(s)
Trastornos Neurológicos de la Marcha , Procedimientos Quirúrgicos Robotizados , Robótica , Fenómenos Biomecánicos , Marcha , Análisis de la Marcha , Humanos , Caminata
6.
Sensors (Basel) ; 21(6)2021 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-33809884

RESUMEN

This paper presents a new architecture that integrates Internet of Things (IoT) devices, service robots, and users in a smart assistive environment. A new intuitive and multimodal interaction system supporting people with disabilities and bedbound patients is presented. This interaction system allows the user to control service robots and devices inside the room in five different ways: touch control, eye control, gesture control, voice control, and augmented reality control. The interaction system is comprised of an assistive robotic arm holding a tablet PC. The robotic arm can place the tablet PC in front of the user. A demonstration of the developed technology, a prototype of a smart room equipped with home automation devices, and the robotic assistive arm are presented. The results obtained from the use of the various interfaces and technologies are presented in the article. The results include user preference with regard to eye-base control (performing clicks, and using winks or gaze) and the use of mobile phones over augmented reality glasses, among others.


Asunto(s)
Personas con Discapacidad , Procedimientos Quirúrgicos Robotizados , Dispositivos de Autoayuda , Atención a la Salud , Humanos
7.
Sensors (Basel) ; 21(4)2021 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-33562005

RESUMEN

Robotic observatories are ideal infrastructures that can be remotely accessed by scientists, amateurs, and general public for research and education in Astronomy. Its robotization is a complex process for ensuring autonomy, safety, and coordination among all subsystems. Some observatories, such as Francisco Sanchez's, are equipped with two types of telescopes: one for the night and one for the day. The night-time telescope must be protected from exposure to sunlight in order to use them in an automated way. For this purpose, this article proposes the design and construction of a smart cover that opens and closes according to the time of day. The mechatronic design covers the electronic, mechanical, and software programming, and it has been devised taking while taking the principles of open design, ease of reproduction, low-cost, and smart behaviour into account. The design has been parameterized, so that it can be adapted to telescopes of any size. The final prototype is lightweight, cost-effective, and can be built while using common 3D printing and PCB milling machines. The complete design is licensed under the GNU General Public License v3.0 and all the documentation, schematics, and software are available in public repositories, like Zenodo, GitHub, and Instructables.

8.
Sensors (Basel) ; 21(4)2021 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-33562695

RESUMEN

Adhesion systems are very important in robots for infrastructure inspection (especially in vertical walls). They present the challenge of optimizing the ratio vacuum/power consumption in battery-powered robots. In this paper, a CFD (computer fluid dynamics) modelling and optimization process of a robot adhesion system is carried out to determine the best performing configuration in terms of vacuum and power consumption. Analytical and numerical models were developed to predict the behaviour of the system for different configurations. The models were validated, using test rig measurements, by calibrating an arbitrary defined inlet height that simulates the leakage flow. Then, different geometric parameters were varied to determine the best performing configuration based on the vacuum/power consumption ratio value. The model presented in the paper was capable of predicting the behaviour of the system for different configurations, with a margin of error of 15% for the vacuum prediction and 25% for the motor power calculation. Finally, the model was used to optimize parameters of the system, like the number of blades of the impeller. The adhesion system was conceived for the modular autonomous climbing legged robot ROMERIN.

9.
Sensors (Basel) ; 20(16)2020 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-32784586

RESUMEN

Several studies have examined the accuracy of the Kinect V2 sensor during gait analysis. Usually the data retrieved by the Kinect V2 sensor are compared with the ground truth of certified systems using a Euclidean comparison. Due to the Kinect V2 sensor latency, the application of a uniform temporal alignment is not adequate to compare the signals. On that basis, the purpose of this study was to explore the abilities of the dynamic time warping (DTW) algorithm to compensate for sensor latency (3 samples or 90 ms) and develop a proper accuracy estimation. During the experimental stage, six iterations were performed using the a dual Kinect V2 system. The walking tests were developed at a self-selected speed. The sensor accuracy for Euclidean matching was consistent with that reported in previous studies. After latency compensation, the sensor accuracy demonstrated considerably lower error rates for all joints. This demonstrated that the accuracy was underestimated due to the use of inappropriate comparison techniques. On the contrary, DTW is a potential method that compensates for the sensor latency, and works sufficiently in comparison with certified systems.


Asunto(s)
Análisis de la Marcha , Programas Informáticos , Algoritmos , Fenómenos Biomecánicos , Marcha , Humanos , Prueba de Paso
10.
Sensors (Basel) ; 17(12)2017 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-29232846

RESUMEN

Falls are the leading cause of injury and death in elderly individuals. Unfortunately, fall detectors are typically based on wearable devices, and the elderly often forget to wear them. In addition, fall detectors based on artificial vision are not yet available on the market. In this paper, we present a new low-cost fall detector for smart homes based on artificial vision algorithms. Our detector combines several algorithms (background subtraction, Kalman filtering and optical flow) as input to a machine learning algorithm with high detection accuracy. Tests conducted on over 50 different fall videos have shown a detection ratio of greater than 96%.


Asunto(s)
Accidentes por Caídas , Anciano , Algoritmos , Humanos , Aprendizaje Automático , Monitoreo Ambulatorio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...