1.
Perfusion ; 35(8): 736-744, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32500818

RESUMEN

INTRODUCTION: In the last decade, dual-lumen cannulae have been increasingly applied in patients undergoing extracorporeal life support. Well-performing vascular access is crucial for efficient extracorporeal membrane oxygenation support; thus, guidance for proper cannulae size is required. Pressure-flow charts provided by manufacturers are often based on tests performed using water, rarely blood. However, blood is a shear-thinning and viscoelastic fluid characterized by different flow properties than water. METHODS: We performed a study evaluating pressure-flow curves during standardized conditions using human whole blood in two commonly available dual-lumen cannulae used in neonates, pediatric, and adult patients. Results were merged and compared with the manufacturer's corresponding curves obtained from the public domain. RESULTS: The results showed that using blood as compared with water predominantly influenced drainage flow. A 10-80% higher pressure-drop was needed to obtain same drainage flow (hematocrit of 26%) compared with manufacturer's water charts in 13-31 Fr bi-caval dual-lumen cannulae. The same net difference was found in cavo-atrial cannulae (16-32 Fr), where a lower drainage pressure was required (Hct of 26%) compared with the manufacturer's test using blood with an Hct of 33%. Return pressure-flow data were similar, independent whether pumping blood or water, to the data reported by manufacturers. CONCLUSION: Non-standardized testing of pressure-flow properties of extracorporeal membrane oxygenation dual-lumen cannulae prevents an adequate prediction of pressure-flow results when these cannulae are used in patients. Properties of dual-lumen cannulae may vary between sizes within same cannula family, in particular concerning the drainage flow.


Asunto(s)
Cánula/normas , Oxigenación por Membrana Extracorpórea/métodos , Humanos , Presión
2.
Perfusion ; 34(1_suppl): 65-73, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30966909

RESUMEN

The use of extracorporeal life support devices such as extracorporeal membrane oxygenation in adults requires cannulation of the patient's vessels with comparatively large diameter cannulae to allow circulation of large volumes of blood (>5 L/min). The cannula diameter and length are the major determinants for extracorporeal membrane oxygenation flow. Manufacturing companies present pressure-flow charts for the cannulae; however, these tests are performed with water. Aims of this study were 1. to investigate the specified pressure-flow charts obtained when using human blood as the circulating medium and 2. to support extracorporeal membrane oxygenation providers with pressure-flow data for correct choice of the cannula to reach an optimal flow with optimal hydrodynamic performance. Eighteen extracorporeal membrane oxygenation drainage cannulae, donated by the manufacturers (n = 6), were studied in a centrifugal pump driven mock loop. Pressure-flow properties and cannula features were described. The results showed that when blood with a hematocrit of 27% was used, the drainage pressure was consistently higher for a given flow (range 10%-350%) than when water was used (data from each respective manufacturer's product information). It is concluded that the information provided by manufacturers in line with regulatory guidelines does not correspond to clinical performance and therefore may not provide the best guidance for clinicians.


Asunto(s)
Cánula , Cateterismo/métodos , Oxigenación por Membrana Extracorpórea/instrumentación , Diseño de Equipo , Humanos , Venas
3.
Perfusion ; 34(1_suppl): 58-64, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30966910

RESUMEN

Adequate extracorporeal membrane oxygenation support in the adult requires cannulae permitting blood flows up to 6-8 L/minute. In accordance with Poiseuille's law, flow is proportional to the fourth power of cannula inner diameter and inversely proportional to its length. Poiseuille's law can be applied to obtain the pressure drop of an incompressible, Newtonian fluid (such as water) flowing in a cylindrical tube. However, as blood is a pseudoplastic non-Newtonian fluid, the validity of Poiseuille's law is questionable for prediction of cannula properties in clinical practice. Pressure-flow charts with non-Newtonian fluids, such as blood, are typically not provided by the manufacturers. A standardized laboratory test of return (arterial) cannulae for extracorporeal membrane oxygenation was performed. The aim was to determine pressure-flow data with human whole blood in addition to manufacturers' water tests to facilitate an appropriate choice of cannula for the desired flow range. In total, 14 cannulae from three manufacturers were tested. Data concerning design, characteristics, and performance were graphically presented for each tested cannula. Measured blood flows were in most cases 3-21% lower than those provided by manufacturers. This was most pronounced in the narrow cannulae (15-17 Fr) where the reduction ranged from 27% to 40% at low flows and 5-15% in the upper flow range. These differences were less apparent with increasing cannula diameter. There was a marked disparity between manufacturers. Based on the measured results, testing of cannulae including whole blood flows in a standardized bench test would be recommended.


Asunto(s)
Cánula , Cateterismo/métodos , Diseño de Equipo/instrumentación , Oxigenación por Membrana Extracorpórea/instrumentación , Hemodinámica/fisiología , Humanos
4.
J Card Surg ; 23(6): 627-32, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-19016986

RESUMEN

BACKGROUND AND AIM: Monitoring of complications in patients undergoing cardiac surgery may be difficult because cardiopulmonary bypass (CPB) can lead to a systemic inflammatory response syndrome because of exposure of blood to nonphysiological surfaces. The purpose of the study was to establish the baseline levels of procalcitonin (PCT) after cardiac surgery in our population in order to analyze a possible induction of the inflammatory response that might interfere with the diagnosis of infection by PCT. METHODS: Serum samples from patients undergoing coronary artery bypass grafting or valve replacement were collected at the time of admission to intensive care unit, after surgery as well as in the first and second postoperative days. Patients were followed for the development of postoperative complications. PCT levels were measured by immunoluminometric assay. RESULTS: The mean PCT values were significantly higher in the first postoperative day in all the groups except the control group. No increased PCT levels were found related neither to duration of CPB, nor to time of aortic clamping. Only patients who presented complications had significantly increased PCT values immediately after surgery (p = 0.004), in the first postoperative day (p < 0.0001), and in the second postoperative day (p < 0.0001) with respect to those who recovered uneventfully. CONCLUSIONS: A slight and transient increase in PCT levels was observed in the first postoperative day after cardiac surgery. Significant elevation of PCT was only observed when complications were present.


Asunto(s)
Calcitonina/sangre , Puente Cardiopulmonar/efectos adversos , Complicaciones Posoperatorias/etiología , Precursores de Proteínas/sangre , Biomarcadores/sangre , Péptido Relacionado con Gen de Calcitonina , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/sangre , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Curva ROC , Factores de Riesgo , Sensibilidad y Especificidad , España/epidemiología , Síndrome de Respuesta Inflamatoria Sistémica/sangre , Síndrome de Respuesta Inflamatoria Sistémica/etiología , Factores de Tiempo