Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Front Psychol ; 14: 1208019, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37599773

RESUMEN

In this prospective observational study, we investigate the role of transactive memory and speaking up in human-AI teams comprising 180 intensive care (ICU) physicians and nurses working with AI in a simulated clinical environment. Our findings indicate that interactions with AI agents differ significantly from human interactions, as accessing information from AI agents is positively linked to a team's ability to generate novel hypotheses and demonstrate speaking-up behavior, but only in higher-performing teams. Conversely, accessing information from human team members is negatively associated with these aspects, regardless of team performance. This study is a valuable contribution to the expanding field of research on human-AI teams and team science in general, as it emphasizes the necessity of incorporating AI agents as knowledge sources in a team's transactive memory system, as well as highlighting their role as catalysts for speaking up. Practical implications include suggestions for the design of future AI systems and human-AI team training in healthcare and beyond.

2.
Burns ; 49(2): 401-407, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-35513952

RESUMEN

BACKGROUND: Hypothermia in severely burned patients is associated with a significant increase in morbidity and mortality. The use of an oesophageal heat exchanger tube (EHT) can improve perioperative body temperatures in severely burned patients. The aim of this study was to investigate the intraoperative warming effect of oesophageal heat transfer in severe burn patients. METHODS: Single-centre retrospective study performed at the Burns Centre of the University Hospital Zurich. Between January 2020 and May 2021 perioperative temperature management with EHT was explored in burned patients with a total body surface area (TBSA) larger than 30%. Data from patients, who received perioperative temperature management by EHT, were compared to data from the same patients during interventions performed under standard temperature management matching for length and type of intervention. RESULTS: A total of 30 interventions (15 with and 15 without EHT) in 10 patients were analysed. Patient were 38 [26-48] years of age, presented with severe burns covering a median of 50 [42-64] % TBSA and were characterized by an ABSI of 10 [8-12] points. When receiving EHT management patients experienced warming at 0.07 °C per minute (4.2 °C/h) compared to a temperature loss of - 0.03 °C per minute (1.8 °C/h) when only receiving standard temperature management (p < 0.0001). No adverse or serious adverse events were reported. CONCLUSION: The use of an oesophageal heat transfer device was effective and safe in providing perioperative warming to severely burned patients when compared to a standard temperature management protocol. By employing an EHT as primary temperature management device perioperative hypothermia in severely burned patients can possibly be averted, potentially leading to reduced hypothermia-associated complications.


Asunto(s)
Quemaduras , Hipotermia Inducida , Hipotermia , Humanos , Temperatura Corporal , Temperatura , Estudios Retrospectivos , Quemaduras/terapia
3.
Burns ; 49(6): 1272-1281, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36566096

RESUMEN

OBJECTIVES: Bromelain-based enzymatic debridement has emerged as a valuable option to the standard surgical intervention for debridement in burn injuries. Adverse effects on coagulation parameters after enzymatic debridement have been described. The purpose of this study was to compare the effect of enzymatic and surgical debridement on coagulation. METHODS: Between 03/2017 and 02/2021 patients with burn injuries with a total body surface area (TBSA) ≥ 1% were included in the study. Patients were categorized into two groups: the surgically debrided group and the enzymatically debrided group. Coagulation parameters were assessed daily for the first seven days of hospitalization. RESULTS: In total 132 patients with a mean TBSA of 17% were included in this study, of which 66 received enzymatic debridement and 66 received regular surgical-debridement. Patients receiving enzymatic debridement presented significantly higher factor-V concentration values over the first seven days after admission (p = <0.01). Regarding coagulation parameters, we found no difference in INR-, aPTT-, fibrinogen-, factor-XIII- and thrombocyte-concentrations over the first seven days (p = >0.05). CONCLUSION: Enzymatic debridement in burned patients does not appear to increase the risk of coagulation abnormalities compared with the regular surgical approach.


Asunto(s)
Trastornos de la Coagulación Sanguínea , Quemaduras , Humanos , Quemaduras/cirugía , Quemaduras/tratamiento farmacológico , Desbridamiento , Bromelaínas/uso terapéutico , Trasplante de Piel
4.
Crit Care ; 26(1): 148, 2022 05 23.
Artículo en Inglés | MEDLINE | ID: mdl-35606831

RESUMEN

BACKGROUND: A higher-than-usual resistance to standard sedation regimens in COVID-19 patients suffering from acute respiratory distress syndrome (ARDS) has led to the frequent use of the second-line anaesthetic agent ketamine. Simultaneously, an increased incidence of cholangiopathies in mechanically ventilated patients receiving prolonged infusion of high-dose ketamine has been noted. Therefore, the objective of this study was to investigate a potential dose-response relationship between ketamine and bilirubin levels. METHODS: Post hoc analysis of a prospective observational cohort of patients suffering from COVID-19-associated ARDS between March 2020 and August 2021. A time-varying, multivariable adjusted, cumulative weighted exposure mixed-effects model was employed to analyse the exposure-effect relationship between ketamine infusion and total bilirubin levels. RESULTS: Two-hundred forty-three critically ill patients were included into the analysis. Ketamine was infused to 170 (70%) patients at a rate of 1.4 [0.9-2.0] mg/kg/h for 9 [4-18] days. The mixed-effects model revealed a positively correlated infusion duration-effect as well as dose-effect relationship between ketamine infusion and rising bilirubin levels (p < 0.0001). In comparison, long-term infusion of propofol and sufentanil, even at high doses, was not associated with increasing bilirubin levels (p = 0.421, p = 0.258). Patients having received ketamine infusion had a multivariable adjusted competing risk hazard of developing a cholestatic liver injury during their ICU stay of 3.2 [95% confidence interval, 1.3-7.8] (p = 0.01). CONCLUSIONS: A causally plausible, dose-effect relationship between long-term infusion of ketamine and rising total bilirubin levels, as well as an augmented, ketamine-associated, hazard of cholestatic liver injury in critically ill COVID-19 patients could be shown. High-dose ketamine should be refrained from whenever possible for the long-term analgosedation of mechanically ventilated COVID-19 patients.


Asunto(s)
COVID-19 , Ketamina , Propofol , Síndrome de Dificultad Respiratoria , Bilirrubina , COVID-19/complicaciones , Enfermedad Crítica , Humanos , Hipnóticos y Sedantes/efectos adversos , Ketamina/efectos adversos , Hígado , Respiración Artificial/efectos adversos , Síndrome de Dificultad Respiratoria/inducido químicamente , Estudios Retrospectivos
5.
J Intensive Care Med ; 36(10): 1184-1193, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34098803

RESUMEN

BACKGROUND: Lung-protective ventilation is key in bridging patients suffering from COVID-19 acute respiratory distress syndrome (ARDS) to recovery. However, resource and personnel limitations during pandemics complicate the implementation of lung-protective protocols. Automated ventilation modes may prove decisive in these settings enabling higher degrees of lung-protective ventilation than conventional modes. METHOD: Prospective study at a Swiss university hospital. Critically ill, mechanically ventilated COVID-19 ARDS patients were allocated, by study-blinded coordinating staff, to either closed-loop or conventional mechanical ventilation, based on mechanical ventilator availability. Primary outcome was the overall achieved percentage of lung-protective ventilation in closed-loop versus conventional mechanical ventilation, assessed minute-by-minute, during the initial 7 days and overall mechanical ventilation time. Lung-protective ventilation was defined as the combined target of tidal volume <8 ml per kg of ideal body weight, dynamic driving pressure <15 cmH2O, peak pressure <30 cmH2O, peripheral oxygen saturation ≥88% and dynamic mechanical power <17 J/min. RESULTS: Forty COVID-19 ARDS patients, accounting for 1,048,630 minutes (728 days) of cumulative mechanical ventilation, allocated to either closed-loop (n = 23) or conventional ventilation (n = 17), presenting with a median paO2/ FiO2 ratio of 92 [72-147] mmHg and a static compliance of 18 [11-25] ml/cmH2O, were mechanically ventilated for 11 [4-25] days and had a 28-day mortality rate of 20%. During the initial 7 days of mechanical ventilation, patients in the closed-loop group were ventilated lung-protectively for 65% of the time versus 38% in the conventional group (Odds Ratio, 1.79; 95% CI, 1.76-1.82; P < 0.001) and for 45% versus 33% of overall mechanical ventilation time (Odds Ratio, 1.22; 95% CI, 1.21-1.23; P < 0.001). CONCLUSION: Among critically ill, mechanically ventilated COVID-19 ARDS patients during an early highpoint of the pandemic, mechanical ventilation using a closed-loop mode was associated with a higher degree of lung-protective ventilation than was conventional mechanical ventilation.


Asunto(s)
COVID-19 , Síndrome de Dificultad Respiratoria , Humanos , Estudios Prospectivos , Respiración Artificial , Síndrome de Dificultad Respiratoria/terapia , SARS-CoV-2 , Volumen de Ventilación Pulmonar
6.
PLoS One ; 11(4): e0152994, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27071039

RESUMEN

BACKGROUND: A high P-wave duration and dispersion (Pd) have been reported to be a prognostic factor for the occurrence of paroxysmal atrial fibrillation (PAF), a condition linked to obstructive sleep apnea (OSA). We tested the hypothesis of whether a short-term increase of P-wave duration and Pd can be induced by respiratory manoeuvres simulating OSA in healthy subjects and in patients with PAF. METHODS: 12-lead-electrocardiography (ECG) was recorded continuously in 24 healthy subjects and 33 patients with PAF, while simulating obstructive apnea (Mueller manoeuvre, MM), obstructive hypopnea (inspiration through a threshold load, ITH), central apnea (AP), and during normal breathing (BL) in randomized order. The P-wave duration and Pd was calculated by using dedicated software for ECG-analysis. RESULTS: P-wave duration and Pd significantly increased during MM and ITH compared to BL in all subjects (+13.1 ms and +13.8 ms during MM; +11.7 ms and +12.9 ms during ITH; p<0.001 for all comparisons). In MM, the increase was larger in healthy subjects when compared to patients with PAF (p<0.05). CONCLUSION: Intrathoracic pressure swings through simulated obstructive sleep apnea increase P-wave duration and Pd in healthy subjects and in patients with PAF. Our findings imply that intrathoracic pressure swings prolong the intra-atrial and inter-atrial conduction time and therefore may represent an independent trigger factor for the development for PAF.


Asunto(s)
Fibrilación Atrial/etiología , Fibrilación Atrial/fisiopatología , Apnea Obstructiva del Sueño/complicaciones , Apnea Obstructiva del Sueño/fisiopatología , Adolescente , Adulto , Anciano , Estudios de Casos y Controles , Electrocardiografía/estadística & datos numéricos , Femenino , Frecuencia Cardíaca/fisiología , Humanos , Masculino , Persona de Mediana Edad , Modelos Biológicos , Presión , Factores de Riesgo , Apnea Central del Sueño/fisiopatología , Adulto Joven
7.
Can J Anaesth ; 62(7): 762-9, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25663254

RESUMEN

INTRODUCTION: Double-lumen endotracheal tubes (DLTs), which are commonly used for single-lung ventilation during surgery, are difficult to insert. In addition, they often move during surgical lung manipulation which can cause life-threatening complications. Flexible bronchoscopy is used routinely to establish and confirm proper DLT placement. The newly designed VivaSight DLT has an integrated camera, allowing continuous visualization of its position in the trachea. We hypothesized that the time to intubation using the VivaSight DLT would be faster than with a conventional DLT. METHODS: We enrolled 40 adults scheduled for thoracic surgery. Patients were randomized to conventional DLT (n = 20) or VivaSight DLT (n = 20). Time to intubation was our primary outcome. Secondary outcomes were insertion success without flexible bronchoscopy, frequency of tube displacement, ease of insertion, quality of lung collapse, postoperative complaints, and airway injuries. RESULTS: Time [mean (SD)] to successful intubation was significantly faster with the VivaSight DLT [63 (58) sec] compared with the conventional DLT [97 (84) sec; P = 0.03]. The VivaSight DLTs were correctly inserted during all attempts. When malpositioning of the VivaSight DLT occurred, it was easily remedied, even in the lateral position. The devices were comparable with respect to postoperative coughing, hoarseness, and sore throat. Airway injuries tended to be more common with the VivaSight DLT, although this study was underpowered for airway injuries. CONCLUSION: The VivaSight DLT camera allowed faster insertion and facilitated initial positioning. It also confirmed proper tube positioning intraoperatively and facilitated repositioning when necessary. This trial was registered at clinicaltrials.gov: NCT01807676.


Asunto(s)
Broncoscopía/métodos , Intubación Intratraqueal/métodos , Ventilación Unipulmonar/métodos , Procedimientos Quirúrgicos Torácicos/métodos , Adulto , Anciano , Diseño de Equipo , Femenino , Humanos , Intubación Intratraqueal/instrumentación , Masculino , Persona de Mediana Edad , Sistema Respiratorio/lesiones , Procedimientos Quirúrgicos Torácicos/instrumentación , Factores de Tiempo
8.
BMC Pulm Med ; 14: 55, 2014 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-24690123

RESUMEN

BACKGROUND: Altered cardiac repolarization and increased dispersion of repolarization have been identified as risk factors for sudden cardiac death (SCD). The prevalence of and the mechanisms contributing to altered cardiac repolarization are currently unknown in COPD. METHODS: In 91 COPD patients, 32 controls matched for age, cardiovascular risk and medication, and 41 healthy subjects, measures of cardiac repolarization and dispersion of repolarization (QTc interval, QT dispersion) were derived from 12-lead electrocardiography (ECG). Prevalence rates of heart rate corrected QT (QTc) >450ms and QT dispersion >60ms were determined to assess the number of subjects at risk for SCD. Univariate and multivariate analyses were used to identify possible factors contributing to altered cardiac repolarization. RESULTS: QTc was found to be prolonged in 31.9% and QT dispersion in 24.2% of the COPD patients compared to 12.5% in matched controls and 0% in healthy subjects. The QTc interval was longer in COPD patients compared to matched and healthy controls respectively (437.9 ± 29.5 vs. 420.1 ± 25.3 ms, p = 0.001 and vs. 413.4 ± 18.2 ms, p < 0.001). QT dispersion was significantly increased in COPD patients compared to healthy subjects (45.4 (34.8 , 59.5) vs. 39.7 (29.3 , 54.8) ms, p = 0.049). Only oxygen saturation was independently associated with QTc duration in multivariate analysis (ß = -0.29, p = 0.015). CONCLUSION: One third of a typical COPD population has altered cardiac repolarization and increased dispersion of repolarization, which may be related to hypoxia. Altered cardiac repolarization may expose these patients to an increased risk for malignant ventricular arrhythmias and SCD.


Asunto(s)
Corazón/fisiopatología , Enfermedad Pulmonar Obstructiva Crónica/complicaciones , Adulto , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Factores de Riesgo
9.
Respiration ; 87(4): 301-10, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24556641

RESUMEN

BACKGROUND: It has been suggested that exhaled breath contains relevant information on health status. OBJECTIVES: We hypothesized that a novel mass spectrometry (MS) technique to analyze breath in real time could be useful to differentiate breathprints from chronic obstructive pulmonary disease (COPD) patients and controls (smokers and nonsmokers). METHODS: We studied 61 participants including 25 COPD patients [Global Initiative for Obstructive Lung Disease (GOLD) stages I-IV], 25 nonsmoking controls and 11 smoking controls. We analyzed their breath by MS in real time. Raw mass spectra were then processed and statistically analyzed. RESULTS: A panel of discriminating mass-spectral features was identified for COPD (all stages; n = 25) versus healthy nonsmokers (n = 25), COPD (all stages; n = 25) versus healthy smokers (n = 11) and mild COPD (GOLD stages I/II; n = 13) versus severe COPD (GOLD stages III/IV; n = 12). A blind classification (i.e. leave-one-out cross validation) resulted in 96% sensitivity and 72.7% specificity (COPD vs. smoking controls), 88% sensitivity and 92% specificity (COPD vs. nonsmoking controls) and 92.3% sensitivity and 83.3% specificity (GOLD I/II vs. GOLD III/IV). Acetone and indole were identified as two of the discriminating exhaled molecules. CONCLUSIONS: We conclude that real-time MS may be a useful technique to analyze and characterize the metabolome of exhaled breath. The acquisition of breathprints in a rapid manner may be valuable to support COPD diagnosis and to gain insight into the disease.


Asunto(s)
Pruebas Respiratorias/métodos , Espectrometría de Masas , Enfermedad Pulmonar Obstructiva Crónica/metabolismo , Adulto , Anciano , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
10.
Heart Lung Circ ; 23(3): 280-6, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24080024

RESUMEN

BACKGROUND: Chronic obstructive pulmonary disease (COPD) has been associated with increased risk for cardiovascular disease but mechanisms underlying this association are incompletely understood. The speed of beat-to-beat changes in systolic blood pressure (vSBP) was found to be pronounced in patients with elevated cardiovascular risk. Although increased vSBP may thus be a contributing mechanism to cardiovascular morbidity, no data exist on vSBP in patients with COPD. Therefore, the purpose of this study was to evaluate whether there is an association between severity of COPD and vSBP. METHODS: Resting beat-to-beat blood pressure was recorded during 5 min. vSBP was assessed by calculating the slopes of oscillatory fluctuations in SBP for different inter-beat intervals (IBI). Univariate and multivariate analyses were performed to evaluate the association between forced expiratory volume in 1 s (FEV1) and vSBP. RESULTS: This study comprised 60 patients with COPD (24 females) with a mean [SD] FEV1 of 45.4 [22.7] %predicted and 34 healthy controls. Short-term fluctuations in SBP were more pronounced in patients with COPD compared to healthy controls. There was a significant inverse correlation between FEV1 and vSBP (r=-0.41, p=0.001). Even after adjustment for covariates in multivariate analysis, FEV1 was found to be independently associated with vSBP. CONCLUSIONS: Patients with COPD are characterised by steeper blood pressure changes than healthy controls. The speed of fluctuations in SBP is associated with the severity of airflow limitation. Increased vSBP may be a mechanism underpinning the association between COPD and cardiovascular disease.


Asunto(s)
Presión Sanguínea , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Adulto , Anciano , Enfermedades Cardiovasculares/etiología , Enfermedades Cardiovasculares/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad Pulmonar Obstructiva Crónica/complicaciones , Factores de Riesgo
11.
J Appl Physiol (1985) ; 115(5): 613-7, 2013 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-23766507

RESUMEN

Preliminary evidence supports an association between obstructive sleep apnea (OSA) and thoracic aortic dilatation, although potential causative mechanisms are incompletely understood; these may include an increase in aortic wall transmural pressures, induced by obstructive apneas and hypopneas. In patients undergoing cardiac catheterization, mean blood pressure (MBP) in the thoracic aorta and esophageal pressure was simultaneously recorded by an indwelling aortic pigtail catheter and a balloon-tipped esophageal catheter in randomized order during: normal breathing, simulated obstructive hypopnea (inspiration through a threshold load), simulated obstructive apnea (Mueller maneuver), and end-expiratory central apnea. Aortic transmural pressure (aortic MBP minus esophageal pressure) was calculated. Ten patients with a median age (range) of 64 (46-75) yr were studied. Inspiration through a threshold load, Mueller maneuver, and end-expiratory central apnea was successfully performed and recorded in 10, 7, and 9 patients, respectively. The difference between aortic MBP and esophageal pressure (and thus the extra aortic dilatory force) was median (quartiles) +9.3 (5.4, 18.6) mmHg, P = 0.02 during inspiration through a threshold load, +16.3 (12.8, 19.4) mmHg, P = 0.02 during the Mueller maneuver, and +0.4 (-4.5, 4.8) mmHg, P = 0.80 during end-expiratory central apnea. Simulated obstructive apnea and hypopnea increase aortic wall dilatory transmural pressures because intra-aortic pressures fall less than esophageal pressures. Thus OSA may mechanically promote thoracic aortic dilatation and should be further investigated as a risk factor for the development or accelerated progression of thoracic aortic aneurysms.


Asunto(s)
Aorta Torácica/fisiología , Aorta Torácica/fisiopatología , Presión Sanguínea/fisiología , Apnea Obstructiva del Sueño/fisiopatología , Anciano , Esófago/fisiología , Esófago/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Respiración , Factores de Riesgo
12.
Hypertens Res ; 36(12): 1039-44, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23784510

RESUMEN

Increased blood pressure variability (BPV), even in the absence of hypertension, has been identified as an important independent cardiovascular risk factor (CVRF). However, the role of the speed of changes in systolic blood pressure (SBP; vSBP) on cardiovascular risk needs to be investigated. The objective of this study was to investigate whether subjects with a high cardiovascular risk profile have an increased degree and speed of changes in SBP compared with subjects with low or no risk. Resting beat-to-beat blood pressure (BP) was recorded for 5 min. Standard BPV measures in both time and frequency domains were conducted. The s.d. of SBP (s.d.-SBP) values was used to quantify the degree of BPV. vSBP was assessed by calculating the slopes of oscillatory fluctuations in SBP for different interbeat intervals (IBI). Subjects were allocated to one of four groups according to the number of CVRFs (0, 1, 2, ≥ 3 CVRF). Of 122 subjects, 19.7% had 0 CVRF, 27.0% had 1, 32.0% had 2 and 21.3% had ≥ 3 CVRFs. There was an increase in vSBP across the four risk groups. The vSBP in patients without CVRF was 3.12 (1.09), 1 CVRF 3.23 (1.07), 2 CVRF 4.16 (2.26) and ≥ 3 CVRF 4.22 (1.66; P = 0.015). The s.d.-SBP was not significantly different between the cardiovascular risk groups. The speed of fluctuations in SBP rather than the degree of BPV is pronounced in patients with elevated cardiovascular risk. Increased speed of BP fluctuations may thus be a contributing mechanism to cardiovascular morbidity.


Asunto(s)
Presión Sanguínea/fisiología , Adolescente , Adulto , Anciano , Algoritmos , Determinación de la Presión Sanguínea , Monitoreo Ambulatorio de la Presión Arterial , Enfermedades Cardiovasculares/fisiopatología , Femenino , Humanos , Hipertensión/fisiopatología , Masculino , Persona de Mediana Edad , Enfermedad Pulmonar Obstructiva Crónica/complicaciones , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Apnea Obstructiva del Sueño/complicaciones , Apnea Obstructiva del Sueño/fisiopatología , Adulto Joven
13.
Eur Respir J ; 42(5): 1194-204, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23429917

RESUMEN

Chronic obstructive pulmonary disease (COPD) is associated with increased cardiovascular mortality. Endothelial dysfunction may underpin this association. This cross-sectional study aimed to determine the impact of airflow obstruction, systemic inflammation, oxidative stress, sympathetic activation, hypoxaemia and physical activity on endothelial function in COPD. In stable COPD patients, assessments of endothelial function by flow-mediated dilatation (FMD), cardiovascular risk (Pocock score), airflow obstruction (forced expiratory volume in 1 s (FEV1)), systemic inflammation (high-sensitivity C-reactive protein and interleukin-6), oxidative stress (malondialdehyde), sympathetic activation (baroreflex sensitivity), hypoxaemia (arterial oxygen tension), hypercapnia (arterial carbon dioxide tension (PaCO2)), physical activity (steps per day) and exercise capacity (6-min walking distance) were performed. Associations between FMD and potential determinants were assessed in univariate and multivariate analyses. 106 patients (Global Initiative for Chronic Obstructive Lung Disease stage I/II 35%, stage III 25% and stage IV 40%) were included. In multivariate analysis FEV1 was positively associated with FMD, independent of other significant FMD determinants from univariate analysis (sex, smoking, combined inhaled long-acting ß-adrenergic and steroid medication, heart rate, baroreflex sensitivity and PaCO2) and adjusted for potential confounders (cardiovascular risk and age). In addition, the FMD and FEV1 association was modified by physical activity. The findings of this study demonstrate that the severity of airflow obstruction is a significant determinant of endothelial function in patients with COPD. A high level of physical activity seems to have a favourable effect on this association.


Asunto(s)
Enfermedades Cardiovasculares/fisiopatología , Endotelio Vascular/fisiopatología , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Corticoesteroides/química , Adulto , Anciano , Barorreflejo , Análisis de los Gases de la Sangre , Presión Sanguínea , Arteria Braquial/patología , Proteína C-Reactiva/metabolismo , Enfermedades Cardiovasculares/complicaciones , Estudios de Cohortes , Femenino , Volumen Espiratorio Forzado , Frecuencia Cardíaca , Humanos , Hipoxia , Inflamación , Masculino , Persona de Mediana Edad , Estrés Oxidativo , Oxígeno/química , Enfermedad Pulmonar Obstructiva Crónica/complicaciones , Análisis de Regresión , Riesgo , Sistema Nervioso Simpático/fisiopatología
14.
Eur J Appl Physiol ; 113(2): 489-96, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22806087

RESUMEN

Preliminary evidence supports an association between OSA and cardiac dysrhythmias. Negative intrathoracic pressure, as occurring during OSA, may provoke cardiac dysrhythmias. Thus, we aimed to study the acute effects of simulated apnea and hypopnea on arrhythmic potential and measures of cardiac repolarization [QT(C) and T (peak) to T (end) intervals [TpTec]) in humans. In 41 healthy volunteers, ECG was continuously recorded prior, during and after simulated obstructive hypopnea (inspiration through a threshold load), simulated apnea (Mueller maneuver), end-expiratory central apnea and normal breathing in randomized order. The number of subjects with premature beats was significantly higher during inspiration through a threshold load (n = 7), and the Mueller maneuver (n = 7) compared to normal breathing (n = 0) (p = 0.008 for all comparisons), but not during end-expiratory central apnea (n = 3, p = 0.125). Inspiration through a threshold load was associated with a non-significant mean (SD) increase of the QT(C) interval [+5.4 (22.4) ms, 95 %CI -1.7 to +12.4 ms, p = 0.168] and a significant increase of the TpTcc interval [+3.7 (8.9) ms, 95 %CI +0.9 to +6.6 ms, p = 0.010]. The Mueller maneuver induced a significant increase of the QT(C) interval [+8.3 (23.4) ms, 95 %CI 0.9 to +15.6 ms, p = 0.035] and the TpTec interval (+4.2 (8.2) ms, 95 %CI +1.6 to +6.8 ms, p = 0.002). There were no significant changes of the QT(C) and TpTec intervals during central end-expiratory apnea. These data indicate that simulated obstructive apnea and hypopnea are associated with an increase of premature beats and prolongation of QT(C) and TpTec intervals. Therefore, negative intrathoracic pressure changes may be a contributory mechanism for the association between OSA and cardiac dysrhythmias.


Asunto(s)
Complejos Cardíacos Prematuros/etiología , Complejos Cardíacos Prematuros/fisiopatología , Mecánica Respiratoria , Apnea Obstructiva del Sueño/complicaciones , Apnea Obstructiva del Sueño/fisiopatología , Adulto , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
15.
PLoS One ; 7(11): e48081, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23133612

RESUMEN

BACKGROUND: Objectively measuring daily physical activity (PA) using an accelerometer is a relatively expensive and time-consuming undertaking. In routine clinical practice it would be useful to estimate PA in patients with chronic obstructive pulmonary disease (COPD) with more simple methods. OBJECTIVES: To evaluate whether PA can be estimated by simple tests commonly used in clinical practice in patients with COPD. METHODS: The average number of steps per day was measured for 7 days with a SenseWear Pro™ accelerometer and used as gold standard for PA. A physical activity level (PAL) of <1.4 was considered very inactive. Univariate and multivariate analyses were used to examine the relationship between the 6-minute walking distance (6MWD), the number of stands in the Sit-to-Stand Test (STST), hand-grip strength and the total energy expenditure as assessed by the Zutphen Physical Activity Questionnaire (TEE(ZPAQ)). ROC curve analysis was used to identify patients with an extremely inactive lifestyle (PAL<1.4). RESULTS: In 70 patients with COPD (21 females) with a mean [SD] FEV(1) of 43.0 [22.0] %predicted, PA was found to be significantly and independently associated with the 6MWD (r = 0.69, 95% CI 0.54 to 0.80, p<0.001), STST (r = 0.51, 95% CI 0.31 to 0.66, p = 0.001) and TEEZPAQ (r = 0.50, 95% CI 0.30 to 0.66, p<0.001) but not with hand-grip strength. However, ROC curve analysis demonstrated that these tests cannot be used to reliably identify patients with an extremely inactive lifestyle. CONCLUSIONS: In patients with COPD simple tests such as the 6-Minute Walk Test, the Sit-to-Stand Test and the Zutphen Physical Activity Questionnaire cannot be used to reliably predict physical inactivity.


Asunto(s)
Monitoreo Ambulatorio/métodos , Actividad Motora , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Aceleración , Actividades Cotidianas , Anciano , Antropometría/métodos , Tolerancia al Ejercicio , Femenino , Volumen Espiratorio Forzado , Fuerza de la Mano , Humanos , Estilo de Vida , Masculino , Persona de Mediana Edad , Análisis Multivariante , Enfermedad Pulmonar Obstructiva Crónica/complicaciones , Curva ROC , Pruebas de Función Respiratoria , Espirometría/métodos , Encuestas y Cuestionarios
16.
Eur Heart J ; 33(17): 2206-12, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22453648

RESUMEN

AIMS: The preliminary evidence supports an association between obstructive sleep apnoea (OSA), disturbed cardiac repolarization, and consequent cardiac dysrhythmias. The aim of the current trial was to assess the effects of continuous positive airway pressure (CPAP) therapy withdrawal on the measures of cardiac repolarization in patients with OSA. METHODS AND RESULTS: Forty-one OSA patients established on CPAP treatment were randomized to either CPAP withdrawal (subtherapeutic CPAP) or continue therapeutic CPAP for 2 weeks. Polysomnography was performed, and indices of cardiac repolarization (QT(c), TpTe(c) intervals) and dispersion of repolarization (TpTe/QT ratio) were derived from 12-lead electrocardiography (ECG) at baseline and 2 weeks. Continuous positive airway pressure withdrawal led to a recurrence of OSA. Compared with therapeutic CPAP, subtherapeutic CPAP for 2 weeks was associated with a significant increase in the length of the QT(c) and TpTe(c) intervals (mean difference between groups 21.4 ms, 95% CI 11.3-1.6 ms, P < 0.001 and 14.4 ms, 95% CI 7.2-21.5 ms, P < 0.001, respectively) and in the TpTe/QT ratio (mean difference between groups 0.02, 95% CI 0.00-0.03, P = 0.020). There was a statistically significant correlation between the change in apnoea/hypopnoea index (AHI) from baseline, and both the change in the QT(c) interval and the TpTe(c) interval (r = 0.60, 95% CI 0.36-0.77, P < 0.001 and r = 0.45, 95% CI 0.17-0.67, P = 0.003, n = 41, respectively). CONCLUSION: Continuous positive airway pressure withdrawal is associated with the prolongation of the QT(c) and TpTe(c) intervals and TpTe/QT ratio, which may provide a possible mechanistic link between OSA, cardiac dysrhythmias, and thus sudden cardiac death.


Asunto(s)
Arritmias Cardíacas/etiología , Presión de las Vías Aéreas Positiva Contínua , Sistema de Conducción Cardíaco/fisiología , Apnea Obstructiva del Sueño/terapia , Arritmias Cardíacas/fisiopatología , Muerte Súbita Cardíaca/prevención & control , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polisomnografía , Apnea Obstructiva del Sueño/fisiopatología , Desconexión del Ventilador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA