Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Nucl Med Commun ; 18(9): 839-45, 1997 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-9352550

RESUMEN

Planar scintimammography with 99Tcm-sestamibi (99Tcm-MIBI) has been shown to be useful in diagnosing breast carcinoma. The aim of this study was to compare single photon emission tomography (SPET) and planar imaging for scintimammography with 99Tcm-MIBI in the detection of primary breast cancer and axillary lymph node involvement. Sixty-three females with mammographically suspicious lesions and 12 controls were evaluated. Dynamic images were acquired commencing immediately after the injection of the radiopharmaceutical, followed by multiple planar images in the supine and prone positions plus SPET supine imaging. A final histopathological diagnosis was achieved after surgery. A total of 66 breast lesions were considered. No focal uptake of 99Tcm-MIBI was observed in the breasts or axillas of the controls. In the patients with breast cancer, the sensitivity was 92.9% (39/42) for SPET, 71.4% (30/42) for supine and 85.7% (36/42) for prone planar imaging, respectively; the specificity was 87.5% for SPET and 91.6% for the planar scans. Metastatic axillary lymph node involvement was seen in 19 patients: the sensitivity was 84.2% (16/19) for SPET and 63.2% (12/19) for planar images; the specificity was 91.3% and 95.7% respectively. Our results confirm the high diagnostic accuracy of 99Tcm scintimammography in the diagnosis of breast cancer, and suggest that SPET is more sensitive than planar images, especially in detecting axillary lymph node involvement.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mamografía/métodos , Radiofármacos , Tecnecio Tc 99m Sestamibi , Tomografía Computarizada de Emisión de Fotón Único/métodos , Adulto , Anciano , Estudios de Casos y Controles , Reacciones Falso Negativas , Femenino , Humanos , Metástasis Linfática/diagnóstico por imagen , Mamografía/estadística & datos numéricos , Persona de Mediana Edad , Sensibilidad y Especificidad , Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos
2.
Anticancer Res ; 17(3B): 1607-10, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9179202

RESUMEN

BACKGROUND: The status of the axillary lymph nodes is the most important prognostic factor in breast cancer, and the findings of axillary node dissection remain the gold standard for the patients staging and prognosis. The aim of this study was to evaluate the usefulness of Tc-99m sestamibi scintigraphy in the detection of axillary node involvement. MATERIALS AND METHODS: Forty-nine patients (age range: 32-72 years) with breast cancer were studied. Dynamic images (1-20 minutes post-injection of the radiopharmaceutical) followed by multiple planar views and tomographic images were performed. Final diagnosis was achieved by histology after surgery. RESULTS: Metastatic axillary lymph node involvement was present in 21 patients: sensitivity was 81% (17/21) for tomographic and 61.9% (13/21) for planar images; specificity was 92.9% (26/28) and 96.4% (27/28), respectively. CONCLUSIONS: Tc-99m sestamibi imaging is a promising noninvasive method to detect axillary node metastases in patients with breast cancer, tomography appears more sensitive than planar views.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Metástasis Linfática/diagnóstico por imagen , Tecnecio Tc 99m Sestamibi , Adulto , Anciano , Axila , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Femenino , Humanos , Escisión del Ganglio Linfático , Persona de Mediana Edad , Estadificación de Neoplasias , Valor Predictivo de las Pruebas , Pronóstico , Sensibilidad y Especificidad , Tomografía Computarizada de Emisión de Fotón Único
3.
Anticancer Res ; 17(3B): 1623-6, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9179206

RESUMEN

BACKGROUND: Scintimammography with Tc-99m sestamibi has recently demonstrated a clinical usefulness in the evaluation of patients with breast lesions. The aim of this study was to assess the potential role of scintimammography using Tc-99m tetrofosmin in the detection of breast cancer. MATERIALS AND METHODS: Fifty-five patients (age range: 33-76 years) with suspicious breast abnormalities detected by mammography, and ten controls were examined. Dynamic images (1-20 min post-injection of the radiopharmaceutical) followed by three planar views were performed. Final diagnosis was achieved by hystology after surgery or excisional biopsy. RESULTS: A total of 59 breast lesions were considered. The sensitivity of Tc-99m tetrofosmin scintimammography for detection of primary breast cancer was 93.1% (27/29) and the specificity was 93.3% (28/30). No focal uptake was observed in both breasts of the control population. CONCLUSIONS: Tc-99m tetrofosmin scintimammography has high diagnostic accuracy in detecting breast cancer and may have a clinical role as complement to conventional mammography.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Carcinoma Ductal de Mama/diagnóstico por imagen , Carcinoma Lobular/diagnóstico por imagen , Compuestos Organofosforados , Compuestos de Organotecnecio , Adulto , Anciano , Biopsia , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Carcinoma Ductal de Mama/patología , Carcinoma Ductal de Mama/cirugía , Carcinoma Lobular/patología , Carcinoma Lobular/cirugía , Diagnóstico Diferencial , Femenino , Humanos , Mamografía , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Cintigrafía , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Anticancer Res ; 17(3B): 1635-8, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9179209

RESUMEN

Mammographic lesions can be classified into categories of high (HR), intermediate (IR) and low risk of breast cancer. We have performed 99mTc MIBI scintimammography on 85 patients with high or intermediate risk lesions in order to verify its ability to diagnose cancer before biopsy. The scintimammography was performed in prone lateral view; all the patients were submitted to excisional biopsy. HR lesions showed 86% of cancers and scintigraphic accuracy of 0.81. The accuracy of scintimammography was 0.97 in lesions larger than 1 cm. IR lesions showed 47% of cancer with scintigraphic accuracy of 0.95. The scintigraphic sensitivity was 0.97 lesions larger than and 0.50 in lesion smaller than 1 cm, whereas the specificity was always about 90%. Our results suggest that scintimammography can substantially decrease the need of biopsy for breast cancer diagnosis.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mamografía , Tecnecio Tc 99m Sestamibi , Adulto , Anciano , Biopsia , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Carcinoma Ductal de Mama/diagnóstico por imagen , Carcinoma Ductal de Mama/patología , Carcinoma Ductal de Mama/cirugía , Reacciones Falso Negativas , Femenino , Humanos , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Cintigrafía , Medición de Riesgo , Sensibilidad y Especificidad , Ultrasonografía Mamaria
5.
Anticancer Res ; 17(3B): 1753-6, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9179229

RESUMEN

Somatostatin (sms) receptors have been identified in carcinoids (c), so enabling their visualization with 111In-pentetreotide scintigraphy. The aim of this study was to evaluate if single photon emission computerized tomography (SPECT) can increase the sensitivity of sms receptor scintigraphy in the detection of abdominal c. 26 patients (pts) with a present, or previously operated, abdominal carcinoid were submitted to SPECT over the abdomen and multiple planar views after the injection of 111In-pentetreotide. Magnetic resonance imaging and computed tomography were also performed. In 19 pts abnormal sites of uptake were found by SPECT which localized 13 abdominal extrahepatic (in 11 pts) and 45 hepatic lesions (in 15 pts). No pathologic accumulation was seen in 7 pts in complete remission after surgery. Planar images visualized 7 abdominal extrahepatic (in 6 pts) and 26 liver tumor sites (in 10 pts), conventional procedures detected 5 abdominal extrahepatic (in 4 pts) and 36 hepatic lesions (in 10 pts). 111In-pentetreotide SPECT is more sensitive than planar scanning and conventional methods to detect abdominal c, and so may play a major role in the early and accurate mapping of tumour spread.


Asunto(s)
Neoplasias Abdominales/diagnóstico por imagen , Tumor Carcinoide/diagnóstico por imagen , Radioisótopos de Indio , Somatostatina/análogos & derivados , Tomografía Computarizada de Emisión de Fotón Único , Neoplasias Abdominales/diagnóstico , Adolescente , Adulto , Anciano , Tumor Carcinoide/diagnóstico , Femenino , Humanos , Neoplasias Intestinales/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Neoplasias Pancreáticas/diagnóstico por imagen , Receptores de Somatostatina/análisis , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...