Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Heliyon ; 8(12): e11868, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36561689

RESUMEN

Background: We present the first case report of the treatment of congenital vaginal atresia by 3D-printed patient-specific vaginal scaffold from China. Case presentation: A 17-year-old female patient was referred to our department for treatment of congenital vaginal atresia and complications arising from previous failed operations. Pelvic examination was conducted to understand the morphological characteristics and severity of stenosis, and based on which we designed our prototypes of vaginal scaffold using software UG NX10.0. We finally obtained our patient-specific mold, which was 50 mm in length, 28 mm in diameter, 2 mm of thickness with a whole weight of 7.6 g, and it was made of polycaprolactone. After removing scar tissues caused by vaginal stenosis, an 8 cm long artificial tunnel was created, and then the polycaprolactone (PCL) vaginal mold was placed and sutured. The patient had no discomfort after surgery and was discharged 3 days after the surgery. Follow-up for 1 year after surgery, through hysteroscopy and colposcopy, it was found that the cervix was smooth, the vaginal wall was covered with stratified squamous epithelium, and the vaginal wall was soft and lubricated, which was close to a normal vagina. The incompletely absorbed mold was taken out one year after the operation. Hysteroscopy and colposcopy were performed one year and two years after the mold was taken out. The vagina was unobstructed and the length was about 12 cm. The appearance of the vaginal wrinkles was normal. The patient's quality of sexual life was good. Conclusion: Our team tried to treat congenital vaginal atresia by 3D-printed patient-specific vaginal scaffold, which can effectively reduce patient complications and reduce patient pain. Through long-term follow-up, we found that this technique has achieved favorable results and improved the patient's quality of sexual life.

2.
Acta Clin Croat ; 61(1): 138-144, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36398079

RESUMEN

Three-dimensional printed polyetheretherketone (PEEK) extravascular stent was applied to treat a 14-year-old boy with nutcracker syndrome. Digital subtraction angiography revealed a segment of the left renal vein (LRV) with reduced contrast filling immediately before its inflow into the inferior vena cava, and high-pressure gradient. The three-dimensional reconstruction model demonstrated that the LRV and the duodenum were contracted at the aortomesenteric angle, resulting in LRV compression from the abnormal high-level duodenal compartment. When duodenum courses between the abdominal aorta and superior mesenteric artery (duodenal interposition), the LRV entrapment occurs even at <90 aortomesenteric degrees. Three-dimensional printed PEEK extravascular stent was chosen to elevate the superior mesenteric artery and lower the duodenum position, thus relieving LRV compression. This extravascular application has significant advantages over open surgery, endovascular stenting and artificial vessel procedures with expanded polytetrafluoroethylene. It provides better cellular vitality by ensuring soft tissue proliferation. By reducing external acceleration and centrifugal force, a three-dimensional printed PEEK extravascular stent reduces adverse side effects. Such a stent has a distinctive personalized design, good stiffness, and durability that allows blood vessel growth, preventing stent migration and thrombosis. Therefore, it is suitable for both adult and pediatric patients. According to the abdominal ultrasound and multi-slice computed tomography scan, the postoperative follow-up results were satisfactory one year after surgery. The patient felt well, the blood flow in the LRV was not obstructed, and the blood flow velocity was average. The external stent was in place.


Asunto(s)
Síndrome de Cascanueces Renal , Adulto , Masculino , Humanos , Adolescente , Niño , Síndrome de Cascanueces Renal/complicaciones , Síndrome de Cascanueces Renal/cirugía , Stents/efectos adversos , Venas Renales/cirugía , Cetonas , Polietilenglicoles , Impresión Tridimensional
3.
BMC Womens Health ; 22(1): 290, 2022 07 14.
Artículo en Inglés | MEDLINE | ID: mdl-35836228

RESUMEN

BACKGROUND: The three-dimensional (3D) printing technology has remarkable potential as an auxiliary tool for representing anatomical structures, facilitating diagnosis and therapy, and enhancing training and teaching in the medical field. As the most available diagnostic tool and it is routinely used as the first approach in diagnosis of the uterine anomalies, 3D transvaginal ultrasonography (3D-TVS) has been proposed as non-invasive "gold standard" approach for these malformations due to high diagnostic accuracy. Despite holding promise of manufacturing 3D printed models based on 3D-TVS data, relevant reports about 3D-TVS derived gynecological 3D printing haven't been reported to the best of our knowledge. We found an opportunity to explore the feasibility of building 3D printed models for the abnormal uterus based on the data acquired by 3D-TVS. METHODS: The women suspected with congenital uterine anomalies (CUAs) were enrolled in the study. The diagnose of CUAs were made by 3D-TVS scanning and further confirmed under the hysteroscopy examination. One volunteer with normal uterus was enrolled as control. All subjects underwent 3D-TVS scanning for 3D printing data collection. Acquired images were stored and extracted as DICOM files, then processed by professional software to portray and model the boundary of the uterine inner and outer walls separately. After the computer 3D models were constructed, the data were saved and output as STL files for further surface restoration and smoothing. The colors of endometrium and uterine body were specified, respectively, in the print preview mode. Then the uncured photosensitive resin was cleaned and polished to obtain a smooth and transparent solid model after printed models were cooled down. RESULTS: 3D printing models of normal uterus, incomplete septate uterus, complete septate uterus, uterus didelphys and unicornuate uterus were produced on ultrasonographic data of 3D-TVS. CONCLUSIONS: Our research and practice made the first try in modeling CUAs successfully based on ultrasonographic data entirely, verifying that it's a feasible way to build 3D printed models of high-quality through 3D-TVS scanning.


Asunto(s)
Impresión Tridimensional , Útero , Femenino , Humanos , Imagenología Tridimensional/métodos , Estudios Prospectivos , Ultrasonografía/métodos , Anomalías Urogenitales , Útero/anomalías , Útero/diagnóstico por imagen
4.
Chin Med J (Engl) ; 132(12): 1454-1460, 2019 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-31205104

RESUMEN

BACKGROUND: This study was designed to evaluate the clinical and radiographic outcomes of patients with nutcracker syndrome (NCS) who were treated with three-dimensional printing (3DP) extravascular titanium stents (EVTSs). The 3DP EVTS was expected to release the hypertension of the left renal vein (LRV) produced by its compression between the superior mesenteric artery (SMA) and the aorta without causing any complications. METHOD: The pre-operative kidney model of each patient was printed out to enable surgical planning. After that, the EVTS was designed based on the LRV's primitive physiologic structure using computer-aided design software, and each stent was printed out with a precision setting of 20 µm. Seventeen patients who had been suffering from NCS underwent laparoscopic 3DP EVTS placement. The surgical procedure was designed for the placement of EVTS, taking great care in positioning and fixing the stent. Surgical data, which included patient demographic characteristics as well as pre- and post-operative test results, were collected and analyzed. RESULTS: The mean duration of surgery was 75 ±â€Š9 min, and the mean blood loss was 20 ±â€Š5 mL. Computed tomography examinations revealed that the pre- and post-operative angle between the SMA and the aorta ranged from 18.7°â€Š±â€Š4.3° to 48.0°â€Š±â€Š8.8° (P < 0.05); in patients with left varicocele, the mean diameter of the left spermatic vein ranged from 3.7 ±â€Š0.5 to 1.3 ±â€Š0.2 mm (P < 0.05). Moreover, Doppler ultrasound examinations showed that the peak velocity of blood flow at the hilar area ranged from 12.4 ±â€Š3.3 to 18.5 ±â€Š3.4 cm/s (P < 0.05). No side effects were observed in the 24 to 42 months following surgery. CONCLUSION: The findings after 2 years of follow-up suggest that the 3DP EVTS is a safe and effective minimally invasive alternative for the treatment of NCS.


Asunto(s)
Síndrome de Cascanueces Renal/cirugía , Stents , Titanio/química , Adolescente , Adulto , Femenino , Humanos , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Impresión Tridimensional , Estudios Retrospectivos , Adulto Joven
5.
Clin Exp Rheumatol ; 35 Suppl 103(1): 134-138, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28466805

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the aortic stiffness (AS) in young female patients with Takayasu's arteritis (TAK) and comparable controls by measuring carotid-femoral PWV (PWVcf) using echocardiography with pulse wave Doppler. The clinical feasibility and reproducibility of this echocardiographic method were also investigated. METHODS: Twenty-five TAK female patients (mean age 28.3±6.2 years) and 25 strictly matched healthy controls were included according to rigorous inclusion and exclusion criteria. The PWVcf of all subjects were measured by echocardiography based on the principle that PWVcf could be calculated by pulse wave spreading distance divided by the transmit time. Reproducibility of the echocardiographic measured PWVcf were performed randomly in 15 TAK patients and 15 healthy controls. RESULTS: The patients with TAK had a higher PWVcf value measured by echocardiography, compared with healthy controls (8.37±2.23 vs. 6.46±1.15 m/s; p<0.001). The echocardiographic measured PWVcf was significantly dependent on the TAK (p=0.003), age (p=0.032) and pulse pressure (p=0.025). PWVcf did not correlate with the echocardiographic measured cardiac systolic and diastolic parameters and the laboratory variables in TAK patients (p>0.05 for all). The intra- and inter-observer coefficients of variation were low and the Bland-Altman plots indicated a satisfactory reproducibility. CONCLUSIONS: Our results indicated that AS in female patients with TAK is increased, which may predict a higher cardiovascular risk. This manifestation is prior to the impairment of cardiac diastolic function. This elevated AS can be detected by echocardiographic measured PWVcf with a good reproducibility.


Asunto(s)
Aorta/diagnóstico por imagen , Ecocardiografía Doppler de Pulso , Arteritis de Takayasu/diagnóstico por imagen , Rigidez Vascular , Adulto , Aorta/fisiopatología , Estudios de Casos y Controles , Estudios Transversales , Femenino , Humanos , Valor Predictivo de las Pruebas , Análisis de la Onda del Pulso , Reproducibilidad de los Resultados , Factores Sexuales , Arteritis de Takayasu/fisiopatología , Adulto Joven
6.
Sci Rep ; 6: 30500, 2016 08 09.
Artículo en Inglés | MEDLINE | ID: mdl-27503416

RESUMEN

To assess racial, sexual, and regional differences in cerebral hemodynamic response to high altitude (HA, 3658 m). We performed cross-sectional comparisons on total cerebral blood flow (TCBF = sum of bilateral internal carotid and vertebral arterial blood flows = QICA + QVA), total cerebrovascular resistance (TCVR), total cerebral oxygen delivery (TCOD) and QVA/TCBF (%), among six groups of young healthy subjects: Tibetans (2-year staying) and Han (Han Chinese) at sea level, Han (2-day, 1-year and 5-year) and Tibetans at HA. Bilateral ICA and VA diameters and flow velocities were derived from duplex ultrasonography; and simultaneous measurements of arterial pressure, oxygen saturation, and hemoglobin concentration were conducted. Neither acute (2-day) nor chronic (>1 year) responses showed sex differences in Han, except that women showed lower TCOD compared with men. Tibetans and Han exhibited different chronic responses (percentage alteration relative to the sea-level counterpart value) in TCBF (-17% vs. 0%), TCVR (22% vs. 12%), TCOD (0% vs. 10%) and QVA/TCBF (0% vs. 2.4%, absolute increase), with lower resting TCOD found in SL- and HA-Tibetans. Our findings indicate racial but not sex differences in cerebral hemodynamic adaptations to HA, with Tibetans (but not Han) demonstrating an altitude-related change of CBF distribution.


Asunto(s)
Altitud , Encéfalo/irrigación sanguínea , Encéfalo/fisiología , Circulación Cerebrovascular/fisiología , Hemodinámica/fisiología , Oxígeno/metabolismo , Grupos Raciales , Caracteres Sexuales , Análisis de Varianza , Pueblo Asiatico , Arteria Carótida Interna/diagnóstico por imagen , Arteria Carótida Interna/fisiología , Demografía , Etnicidad , Femenino , Humanos , Masculino , Ultrasonografía , Arteria Vertebral/diagnóstico por imagen , Arteria Vertebral/fisiología , Adulto Joven
7.
Artículo en Inglés | MEDLINE | ID: mdl-25904575

RESUMEN

BACKGROUND: The central venous pressure (CVP) is essential for assessing the cardiac preload and circulating blood volume in clinic. The invasive CVP measurement by central venous catheter has been reported with various complications. The aim of this study was to develop a new noninvasive method for quantification of CVP by ultrasound. METHODS AND RESULTS: Seventy-six patients who had their CVP monitored for intraoperative or postoperative management were recruited. By accurate location of the collapse point of the internal jugular vein and the center of the right atrium using ultrasound imaging, the height of the fluid column between those 2 points was measured as the noninvasive CVP (CVPn). A total of 118 measurements were performed and compared with the invasive CVP (CVPi). Linear correlation analysis revealed a significant correlation between CVPi and CVPn (preoperative measurements, r=0.90; P<0.01 and postoperative measurements, r=0.93; P<0.01). Bland-Altman plots showed a good agreement between CVPi and CVPn with the mean difference of 0.22 mm Hg (preoperative measurements) and -0.09 mm Hg (postoperative measurements), respectively. CONCLUSIONS: The new noninvasive CVP quantification method based on the location of both the collapse point of internal jugular vein and the center of right atrium by ultrasound could be used as a reliable approach for monitoring the hemodynamic status in clinic.


Asunto(s)
Determinación de la Presión Sanguínea/métodos , Presión Venosa Central/fisiología , Cateterismo Venoso Central , Ecocardiografía , Estudios de Factibilidad , Femenino , Atrios Cardíacos/diagnóstico por imagen , Hemodinámica , Humanos , Imagenología Tridimensional , Venas Yugulares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X
8.
PLoS One ; 10(3): e0120482, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25786124

RESUMEN

OBJECTIVES: To evaluate the validity and reproducibility of a noninvasive dual pulse wave Doppler (DPWD) method, which involves simultaneous recording of flow velocity of two independent sample volumes with a measurable distance, for measuring the local arterial pulse wave velocity (PWV) through in vitro and in vivo studies. METHODS: The DPWD mode of Hitachi HI Vision Preirus ultrasound system with a 5-13MHz transducer was used. An in vitro model was designed to compare the PWV of a homogeneous rubber tubing with the local PWV of its middle part measured by DPWD method. In the in vivo study, local PWV of 45 hypertensive patients (25 male, 49.8±3.1 years) and 45 matched healthy subjects (25 male, 49.3±3.0 years) were investigated at the left common carotid artery (LCCA) by DPWD method. RESULTS: In the in vitro study, the local PWV measured by DPWP method and the PWV of the homogeneous rubber tubing did not show statistical difference (5.16 ± 0.28 m/s vs 5.03 ± 0.15 m/s, p = 0.075). The coefficient of variation (CV) of the intra- and inter- measurements for local PWV were 3.46% and 4.96%, for the PWV of the homogeneous rubber tubing were 0.99% and 1.98%. In the in vivo study, a significantly higher local PWV of LCCA was found in the hypertensive patients as compared to that in healthy subjects (6.29±1.04 m/s vs. 5.31±0.72 m/s, P = 0.019). The CV of the intra- and inter- measurements in hypertensive patients were 2.22% and 3.94%, in healthy subjects were 2.07% and 4.14%. CONCLUSIONS: This study demonstrated the feasibility of the noninvasive DPWD method to determine the local PWV, which was accurate and reproducible not only in vitro but also in vivo studies. This noninvasive echocardiographic method may be illuminating to clinical use.


Asunto(s)
Arteria Carótida Común/fisiopatología , Hipertensión/diagnóstico , Flujometría por Láser-Doppler/métodos , Modelos Cardiovasculares , Análisis de la Onda del Pulso/métodos , Estudios de Casos y Controles , Femenino , Frecuencia Cardíaca , Humanos , Hipertensión/fisiopatología , Flujometría por Láser-Doppler/instrumentación , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Análisis de la Onda del Pulso/instrumentación , Reproducibilidad de los Resultados , Goma
9.
BMC Pregnancy Childbirth ; 14: 113, 2014 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-24666973

RESUMEN

BACKGROUND: Cardiovascular adaptions, such as cardiac and uterine spiral arterial remodeling, and aortic arterial stiffening during pregnancy have been extensively investigated, while the interactions between the elastic artery and the left ventricle are poorly understood. This study was to evaluate the cardiac-arterial coupling in both normal pregnancy and preeclampsia using ultrasound techniques. METHODS: Twenty-three preeclamptic women with no antihypertensive treatment prior to admission, and 40 age- (27.2 ± 3.0 y vs. 29.1 ± 5.7 y, p = 0.0805) and gestational week- (35.6 ± 3.4 wk vs. 34.8 ± 3.6 wk, p = 0.3573) matched normotensive pregnant women were included. All women signed informed consent. All were nulliparas, had singleton pregnancies, and had no other risk factors for arterial stiffening. Carotid and cardiac ultrasound was performed using a MylabTwice ultrasound unit (Esaote, Italy). Cardiac and carotid remodeling and their associations were analyzed. Left ventriculo-carotid coupling was characterized by the ratio between the arterial elastance (Ea) and the left ventricular systolic elastance (Ees). Follow-up study was performed 16-20 months after parturition. RESULTS: Left ventricular and carotid arterial remodeling was seen more frequently in preeclamptic women than in normal pregnant controls (96% vs. 40%, 82% vs. 48%, both p < 0.0001). The relative carotid arterial wall thickness showed no significant difference between the two groups. However, the carotid cross-sectional area, a surrogate for carotid arterial mass, was significantly greater in preeclampsia than that in normal controls (11.23 ± 0.17 mm2 vs. 8.58 ± 1.88 mm2, p < 0.00001). Carotid arterial stiffness and intima-media thickness correlated significantly with cardiac diastolic function parameters and blood pressures (p < 0.05). Both Ea and Ees were significantly greater in preeclampsia, compared with values in normal pregnant controls (Ea: 2.41 ± 0.57 mmHg/ml vs. 1.98 ± 0.46 mmHg/ml, p = 0.0005; Ees: 11.68 ± 9.51 m/s2 vs. 6.91 ± 6.13 m/s2, p = 0.002). However, there was no significant difference in the left ventriculo-carotid coupling index, Ea/Ees, between the two groups. Carotid remodeling persisted in both preeclamptic women and normal pregnant controls 16-20 months after parturition. CONCLUSIONS: Significant cardiac and carotid remodeling and similar left ventriculo-carotid coupling were observed in both preeclampsia and normal pregnancy. Carotid remodeling may persist postpartum. Further studies with larger populations are needed to confirm these findings.


Asunto(s)
Arteria Carótida Común/diagnóstico por imagen , Ecocardiografía/métodos , Preeclampsia/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Rigidez Vascular/fisiología , Función Ventricular Izquierda/fisiología , Remodelación Ventricular , Adulto , Arteria Carótida Común/fisiopatología , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/embriología , Humanos , Recién Nacido , Preeclampsia/fisiopatología , Embarazo , Resultado del Embarazo , Estudios Retrospectivos , Factores de Tiempo
10.
Cardiovasc Diabetol ; 13: 39, 2014 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-24506844

RESUMEN

BACKGROUND: Type 2 diabetes is one of the most common causes of cardiovascular disease as it causes arterial stiffness changes. The purpose of this study is to characterize, in vivo, carotid arterial structural and functional changes by applying radio frequency and X-strain ultrasound techniques. METHODS: Ninety-one subjects were assigned into two groups; a diabetes group and a control group. Structural and functional changes in the common carotid arterial wall were investigated by quality intima-media thickness (QIMT), quality arterial stiffness (QAS), and X-strain analysis with a Mylab Twice ultrasound instrument. The relationships among variables between the two groups were analyzed in this study. RESULTS: There was no significant difference in carotid IMT (626.5 ± 169.1 µm vs. 568.5 ± 122.6 µm, P = 0.1506) between two groups. Pulse wave velocity (PWV) and stiffness index (ß) were remarkably greater (8.388 ± 3.254 m/s vs. 7.269 ± 1.332 m/s; 12.51 ± 14.16 vs.9.279 ± 2.871), while compliance coefficient (CC) decreased significantly in the diabetes group (0.802 ± 0.3094 mm2/Kpa vs. 0.968 ± 0.3992 mm2/Kpa) (P < 0.05). The displacement difference of radial (RD-D), longitudinal (LD-D) and rotation (ROT-D) directions were significantly different between two groups' comparison (P = 0.0212, P = 0.0235 and P = 0.0072, respectively). The time of circumferential peak strain difference (CS-DT) and the time of radial peak strain rate (RSR-T) were found to be significantly different between the two groups (341.9 ± 77.56 ms vs. 369.0 ± 78.26 ms, P = 0.0494; 142.7 ± 22.43 ms vs. 136.2 ± 30.70 ms, P = 0.0474). CS-TD and RSR-T were also found to be positively correlated with CC value (r = 0.3908, P < 0.005 and r = 0.3027, P = 0.0326, respectively). Finally, PWV was negatively correlated with CC with (r = -0.6177, P < 0.001). CONCLUSIONS: In type 2 diabetes, the functional changes in CCA can be identified using the methods presented in this article earlier than the structural changes. Arterial stiffness values provided by QAS and X-strain analysis can be used as indicators of CCA functional lesions in patients with type 2 diabetes.


Asunto(s)
Arteria Carótida Común/patología , Grosor Intima-Media Carotídeo/normas , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/fisiopatología , Elasticidad/fisiología , Rigidez Vascular/fisiología , Adulto , Anciano , Velocidad del Flujo Sanguíneo/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA