1.
Surg Endosc ; 2024 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-39285042

RESUMEN

BACKGROUND: Thyroid surgery has undergone significant transformation with the introduction of minimally invasive techniques, particularly robotic and endoscopic thyroidectomy. These advancements offer improved precision and faster recovery but also present unique challenges. This study aims to compare the learning curves, operational efficiencies, and patient outcomes of robotic versus endoscopic thyroidectomy. METHODS: A retrospective cohort study was conducted, analyzing 258 robotic (da Vinci) and 214 endoscopic thyroidectomy cases. Key metrics such as operation duration, drainage volume, lymph node dissection outcomes, and hypoparathyroidism incidence were assessed to understand surgical learning curves and efficiency. RESULTS: Robotic thyroidectomy showed a longer learning curve with initially longer operation times and higher drainage volumes but superior lymph node dissection outcomes. Both techniques were safe, with no permanent hypoparathyroidism or recurrent laryngeal nerve damage reported. The study delineated four distinct stages in the robotic and endoscopic surgery learning curve, each marked by specific improvements in proficiency. Endoscopic thyroidectomy displayed a shorter learning curve, leading to quicker operational efficiency gains. CONCLUSION: Robotic and endoscopic thyroidectomies are viable minimally invasive approaches, each with its learning curves and efficiency metrics. Despite initial challenges and a longer learning period for robotic surgery, its benefits in complex dissections may justify specialized training. Structured training programs tailored to each technique are crucial for improving outcomes and efficiency. Future research should focus on optimizing training protocols and increasing accessibility to these technologies, enhancing patient care in thyroid surgery.

2.
Cancer Res Treat ; 51(2): 483-492, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29890814

RESUMEN

PURPOSE: The purpose of this study was to detect the lymphatic drainage pattern of internal mammary area and verify the concept of internal mammary sentinel lymph node (IM-SLN) in breast. MATERIALS AND METHODS: A small particle radiotracer (99mTc-Dextran 40) was prepared and tested. 99mTc-Dextran 40 was injected into intraparenchyma at the sound breast by a modified radiotracer injection technique. Subsequently, dynamic single-photon emission computed tomography (SPECT), computed tomography (CT), and SPECT/CT combination images were performed to identify the radioactive lymph vessels and internal mammary lymph nodes (IMLNs). The direction of lymph drainage and the location of the IMLNs were identified in the SPECT/CT imaging. RESULTS: The radiochemical purity of 99mTc-Dextran 40 was > 95%. 99mTc-Dextran 40 could drainage into first, second, and third lymph node and the radioactive lymph node could be detected by the γ detector in the animal experiment. After 99mTc-Dextran 40 injecting into intraparenchyma, 50.0% cases (15/30) were identified the drainage lymphatic vessels and radioactive IMLNs by SPECT. The drainage lymphatic vessel was found from injection point to the first IMLN (IM-SLN) after 10.5±0.35 minutes radiotracer injection, and then 99mTc-Dextran 40 was accumulated into the IM-SLN. The combination imaging of SPECT/CT showed the second IMLN received the lymph drainage from the IM-SLN. The lymphatic drainage was step by step in the internal mammary area. CONCLUSION: The lymph was identified to drain from different regions of the breast to IM-SLN, and then outward from IM-SLN to other IMLN consecutively. It demonstrated the concept of the IM-SLN and provided more evidences for the application of internal mammary sentinel lymph node biopsy.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Dextranos , Trazadores Radiactivos , Ganglio Linfático Centinela/patología , Tecnecio , Adulto , Anciano , Animales , Densidad de la Mama , Modelos Animales de Enfermedad , Femenino , Xenoinjertos , Humanos , Metástasis Linfática , Ratones , Persona de Mediana Edad , Estadificación de Neoplasias , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada por Rayos X
3.
Medicine (Baltimore) ; 97(21): e10616, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29794736

RESUMEN

RATIONALE: The parotid gland is an unusual site for metastatic disease from breast cancer, and it usually has a poor prognosis. PATIENT CONCERNS: A 36-year-old woman presented to our department with a swelling in her left parotid gland. The patient did not receive any other treatment after breast conserving surgery. DIAGNOSES: Multifocal metastases in the bones, lymph nodes, left parotid and contralateral mammary gland were proved by PET/CT. INTERVENTIONS: Eight cycles of first-line rescue chemotherapy, combining with zoledronic acid in treatment of bone metastasis, followed by the combination of endocrine therapy and ovarian function suppression after chemotherapy. OUTCOMES: The patient obtained clinical complete response in the metastasis tumor of parotid gland, lymph nodes, and bones. LESSONS: It is necessary for patient to receive comprehensive treatment after receiving surgery. Through this case, we present the appropriate management of advanced breast cancer accompanying with the parotid gland metastasis. PET/CT is a useful method to diagnose and evaluate the metastasis lesions.


Asunto(s)
Neoplasias de la Mama/patología , Glándula Parótida/patología , Neoplasias de la Parótida/secundario , Adulto , Antineoplásicos/uso terapéutico , Neoplasias de la Mama/terapia , Terapia Combinada/métodos , Difosfonatos/uso terapéutico , Femenino , Humanos , Imidazoles/uso terapéutico , Mastectomía Segmentaria/métodos , Neoplasias de la Parótida/diagnóstico por imagen , Neoplasias de la Parótida/terapia , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Ácido Zoledrónico
4.
Oncotarget ; 8(46): 81583-81590, 2017 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-29113416

RESUMEN

Inclusion internal mammary lymph nodes as a part of regional nodal irradiation have a potential to reduce local recurrence, distant recurrence, and improve survival in breast cancer. However, the increased risk of cardiac toxicity and lungs injure associated with internal mammary lymph nodes irradiation has drew more and more attention. Estimating risk of metastasis in internal mammary lymph nodes based on axillary lymph nodes metastasis status is not always reliable: low-risk do not always mean negative in internal mammary lymph nodes and high-risk do not always indicate positive in internal mammary lymph nodes. Inaccurate prediction of in internal mammary lymph nodes metastasis might lead to over- or under-treatment of in internal mammary lymph node. Internal mammary sentinel lymph node biopsy is a minimally invasive technique which has a high potential to accurately evaluate the metastasis status in in internal mammary lymph nodes and improve accuracy of nodal staging. This technique might be a useful tool to guide individualized internal mammary lymph nodes irradiation.

6.
Oncotarget ; 7(45): 74074-74081, 2016 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-27738336

RESUMEN

With the improvement of neoadjuvant chemotherapy (NAC), the proportion of pathological complete response (pCR) in the breast and axillary lymph node (ALN) is increasing. The evaluation of pCR does not include the status of internal mammary lymph node (IMLN). This study is to evaluate the roles of both axillary sentinel lymph node biopsy (ASLNB) and internal mammary sentinel lymph node biopsy (IM-SLNB) in breast cancer patients after NAC. There were 74 patients enrolled into this study. IM-SLNB was performed on patients with radioactive internal mammary sentinel lymph node (IM-SLN). Patients (n = 8) with cN0 and ycN0 received ASLNB, and axillary lymph node dissection (ALND) in cases of positive axillary sentinel lymph node (ASLN). Patients (n = 48) with cN+ but ycN0 received ASLNB and ALND. Patients (n = 18) with ycN+ received ALND without ASLNB. The visualization rate of IM-SLN was 56.8% (42/74). The success rate of IM-SLNB was 97.6% (41/42) and the metastasis rate of IM-SLN was 7.3% (3/41). The success rate of ASLNB was 100% (56/56). The false negative rate (FNR) of ASLNB was 17.2% (5/29). The FNR in patients with 1, 2 and ≥ 3ASLNs examined was 27.3% (3/11), 20.0% (2/10) and 0% (0/8) respectively. ASLNB could be performed on ycN0 after NAC, and ALND should be performed on initially ALN-positive patients. IM-SLNB should be considered after NAC, especially for patients with clinically positive axillary nodes before NAC, which might help make clear of the pathological nodal staging of both ALN and IMLN, improve the definition of nodal pCR, and guide the individual adjuvant regional and systemic therapy.


Asunto(s)
Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/patología , Biopsia del Ganglio Linfático Centinela/métodos , Adulto , Anciano , Axila , Femenino , Humanos , Metástasis Linfática , Persona de Mediana Edad , Terapia Neoadyuvante
7.
Oncotarget ; 7(30): 47526-47535, 2016 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-27374088

RESUMEN

An appropriate receptor-targeted tracer for sentinel lymph node biopsy (SLNB) was prepared. We combined the fluorescence tracer (Indocyanine green, ICG) with Rituximab (a chimeric human/murine monoclonal antibody targeting the CD20 antigen on the surface of lymphocyte) directly to produce a new tracer (ICG-Rituximab). When the new tracer drains to the lymph node, Rituximab will combine with CD20 receptor on the B-cell surface in the lymph node. If the statue of antibody-receptor connection does not reach saturation, the number of Rituximab is less than CD20. With this appropriate injection dose, the new tracer could only stay in sentinel lymph node (SLN) and make it imaging. Positive fluorescence SLN was detected 12 minutes after injection with no other organs imaging. The imaging of SLN was stable and clear for 20-24 hours. Due to SLN stained with more ICG than the lymphatic vessel, the fluorescence situation of SLN would be brighter than the vessel. The surgeon can detect the positive fluorescence SLN easily without following the fluorescence imaging lymphatic vessel. The results of our preliminary study showed that the new tracer might be useful for improving SLN imaging and worth further clinical study. SLNB with the new tracer could be a convenient method for detecting SLN and would become a standard performance in clinical practice.


Asunto(s)
Neoplasias de la Mama/patología , Verde de Indocianina , Rituximab/metabolismo , Biopsia del Ganglio Linfático Centinela/métodos , Ganglio Linfático Centinela/diagnóstico por imagen , Animales , Femenino , Fluorescencia , Masculino , Ratones , Ratones Endogámicos BALB C
8.
Oncotarget ; 7(27): 41996-42006, 2016 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-27248827

RESUMEN

According to axilla sentinel lymph node lymphatic drainage pattern, we hypothesized that internal mammary sentinel lymph node (IM-SLN) receives lymphatic drainage from not only the primary tumor area, but also the entire breast parenchyma. Based on the hypothesis a modified radiotracer injection technique was established and could increase the visualization rate of the IM-SLN significantly. To verify the hypothesis, two kinds of tracers were injected at different sites of breast. The radiotracer was injected with the modified technique, and the fluorescence tracer was injected in the peritumoral intra-parenchyma. The location of IM-SLN was identified by preoperative lymphoscintigraphy and intraoperative gamma probe. Then, internal mammary sentinel lymph node biopsy (IM-SLNB) was performed. The fluorescence status of IM-SLN was identified by the fluorescence imaging system. A total of 216 patients were enrolled from September 2013 to July 2015. The overall visualization rate of IM-SLN was 71.8% (155/216). The success rate of IM-SLNB was 97.3% (145/149). The radiotracer and the fluorescence tracer were identified in the same IM-SLN in 127 cases, the correlation and the agreement is significant (Case-base, rs=0.836, P<0.001; Kappa=0.823, P<0.001). Different tracers injected into the different sites of the intra-parenchyma reached the same IM-SLN, which demonstrates the hypothesis that IM-SLN receives the lymphatic drainage from not only the primary tumor area but also the entire breast parenchyma.


Asunto(s)
Neoplasias de la Mama/patología , Ganglios Linfáticos/patología , Biopsia del Ganglio Linfático Centinela , Adulto , Anciano , Axila , Biopsia , Femenino , Colorantes Fluorescentes/química , Humanos , Verde de Indocianina/química , Yodo/química , Metástasis Linfática/patología , Persona de Mediana Edad , Periodo Preoperatorio , Estudios Retrospectivos , Resultado del Tratamiento
10.
Onco Targets Ther ; 8: 2705-8, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26445553

RESUMEN

According to the hypothesis of internal mammary sentinel lymph node (IM-SLN) lymphatic drainage pattern, a modified radiotracer injection technique (periareolar intraparenchyma, high volume, and ultrasonographic guidance) was established. To verify the accuracy of the hypothesis and validate the modified radiotracer injection technique and to observe whether the lymphatic drainage of the whole breast parenchyma could reach to the same IM-SLN, different tracers were injected into different locations of the breast. The validation study results showed that the correlation and the agreement of the radiotracer and the fluorescence tracer are significant (case-base, r s =0.808, P<0.001; Kappa =0.79, P<0.001). It proved that the lymphatic drainage from different location of the breast (the primary tumor, the subareolar plexus) reached the same IM-SLNs and the hypothesis of IM-SLN lymphatic drainage pattern (ie, IM-SLN receives lymphatic drainage from not only the primary tumor area, but also the entire breast parenchyma). In other words, it validated the accuracy of our modified radiotracer injection technique.