Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Infect Dis (Lond) ; : 1-13, 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39046827

RESUMEN

BACKGROUND: To infer a reliable SARS-CoV-2 antibody protection level from a serological test, an appropriate quantitative threshold and solid equivalence across serological tests are needed. Additionally, tests should show a solid correlation with neutralising assays and with the protection observed in large population cohorts even against emerging variants. OBJECTIVES: We studied convalescent and vaccinated populations using 11 commercial antibody assays. Results were compared to evaluate discrepancies across tests. Neutralisation capacity was measured in a subset of the samples with a lentiviral-based assay. METHODS: Serum from convalescent (n = 121) and vaccinated individuals (n = 471, 260 with Comirnaty, 110 with Spikevax, and 96 with Vaxzevria) was assessed using 11 different assays, including two from Abbott, Euroimmun, Liaison, Roche, and Vircell, and one from Siemens. A spike protein-lentiviral vector with a fluorescent reporter was used for neutralisation assay of serum from convalescent (n = 26) and vaccinated (n = 39) individuals. RESULTS: Positivity ranged between 81.3 and 94.3% after infection and 99.4 and 99.7% after vaccination, depending on the assay. Both cohorts showed a high level of qualitative agreement across tests (Fleiss' kappa = 0.598 and 0.719 for convalescent and vaccinated respectively). Spikevax vaccine recipients showed the highest level of antibodies in all tests. Effectiveness of each test predicting SARS-CoV-2 neutralising capacity depended on assay type and target, with CLIA and anti-S being more effective than ELISA and anti-N assays, respectively. CONCLUSIONS: High-throughput immunoassays are good predictors of neutralising capacity. Updated targets and better standardisation would be required to find an effective correlate of protection, especially to account for antibodies against new variants.

2.
Int J Mol Sci ; 23(19)2022 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-36233328

RESUMEN

Implant-associated infection due to biofilm formation is a growing problem. Given that silver nanoparticles (Ag-NPs) have shown antibacterial effects, our goal is to study their effect against multispecies biofilm involved in the development of peri-implantitis. To this purpose, Ag-NPs were synthesized by laser ablation in de-ionized water using two different lasers, leading to the production of colloidal suspensions. Subsequently, part of each suspension was subjected to irradiation one and three times with the same laser source with which it was obtained. Ag-NPs were immobilized on the surface of titanium discs and the resultant materials were compared with unmodified titanium coupons. Nanoparticles were physico-chemically analysed to determine their shape, crystallinity, chemical composition, and mean diameter. The materials were incubated for 90 min or 48 h, to evaluate bacterial adhesion or biofilm formation respectively with Staphylococcus aureus or oral mixed bacterial flora composed of Streptococcus oralis, Actinomyces naeslundii, Veionella dispar, and Porphyromonas gingivalis. Ag-NPs help prevent the formation of biofilms both by S. aureus and by mixed oral bacterial flora. Nanoparticles re-irradiated three times showed the biggest antimicrobial effects. Modifying dental implants in this way could prevent the development of peri-implantitis.


Asunto(s)
Implantes Dentales , Terapia por Láser , Nanopartículas del Metal , Periimplantitis , Reirradiación , Antibacterianos/farmacología , Biopelículas , Humanos , Periimplantitis/prevención & control , Porphyromonas gingivalis , Plata/farmacología , Staphylococcus aureus , Suspensiones , Titanio/química , Titanio/farmacología , Agua/farmacología
3.
Virol J ; 19(1): 168, 2022 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-36303187

RESUMEN

BACKGROUND: SARS-CoV-2 variant tracking is key to the genomic surveillance of the COVID-19 pandemic. While next-generation sequencing (NGS) is commonly used for variant determination, it is expensive and time-consuming. Variant-specific PCR (vsPCR) is a faster, cheaper method that detects specific mutations that are considered variant-defining. These tests usually rely on specific amplification when a mutation is present or a specific melting temperature peak after amplification. CASE PRESENTATION: A discrepant result between vsPCR and NGS was found in seventeen SARS-CoV-2 samples from Galicia, Spain. A cluster of BA.1 Omicron SARS-CoV-2 variant showed a BA.2-like melting temperature pattern due to a point mutation (C21772T) downstream the deletion of the spike amino acids 69/70. As the 69/70 deletion is widely used for differentiation between BA.1 and BA.2 by vsPCR, C21772T can cause BA.1 samples to be misinterpreted as BA.2. Over a thousand BA.1 sequences in the EpiCoV database contain this mutation. CONCLUSIONS: To our knowledge, this is the first case of a point mutation causing a vsPCR algorithm to misclassify BA.1 samples as BA.2. This is an example of how mutations in the probe target area of vsPCR tests based on melting curve analysis can lead to variant misclassification. NGS confirmation of vsPCR results is relevant for the accuracy of the epidemiological surveillance. In order to overcome the possible impact of novel mutations, diagnostic tools must be constantly updated.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Mutación Puntual , Pandemias , COVID-19/diagnóstico , Reacción en Cadena de la Polimerasa , Mutación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...