Resultados 1 - 8 de 8
Filtrar
1.
Radiother Oncol ; : 110513, 2024 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-39222848

RESUMEN

BACKGROUND AND PURPOSE: Over the past decade, tools for automation of various sub-tasks in radiotherapy planning have been introduced, such as auto-contouring and auto-planning. The purpose of this study was to benchmark what degree of automation is possible. MATERIALS AND METHODS: A challenge to perform automated treatment planning for prostate and prostate bed radiotherapy was set up. Participants were provided with simulation CTs and a treatment prescription and were asked to use automated tools to produce a deliverable radiotherapy treatment plan with as little human intervention as possible. Plans were scored for their adherence to the protocol when assessed using consensus expert contours. RESULTS: Thirteen entries were received. The top submission adhered to 81.8% of the minimum objectives across all cases using the consensus contour, meeting all objectives in one of the ten cases. The same system met 89.5% of objectives when assessed with their own auto-contours, meeting all objectives in four of the ten cases. The majority of systems used in the challenge had regulatory clearance (Auto-contouring: 82.5%, Auto-planning: 77%). Despite the 'hard' rule that participants should not check or edit contours or plans, 69% reported looking at their results before submission. CONCLUSIONS: Automation of the full planning workflow from simulation CT to deliverable treatment plan is possible for prostate and prostate bed radiotherapy. While many generated plans were found to require none or minor adjustment to be regarded as clinically acceptable, the result indicated there is still a lack of trust in such systems preventing full automation.

2.
Phys Med Biol ; 69(13)2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38759691

RESUMEN

Objective.Spatially fractionated radiotherapy is showing promise as a treatment modality. Initial focus was on beams of photons at low energy produced from a synchrotron but more recently research has expanded to include applications in proton therapy. Interest in photon beams remains and this is the focus of this paperApproach.This study presents a 3D printed tungsten minibeam collimator intended to produce peak-to-valley dose ratios (PVDR) of between seven and ten with a 1 MV, bremsstrahlung generated, photon beam. The design of the collimator is motivated by a Monte Carlo study estimating the PVDR for different collimator designs at different energies. This collimator was characterised on a clinical linear accelerator (Elekta VersaHD) as well as an orthovoltage unit.Main results.The performance of the fabricated collimator was measured on Elekta VersaHD running in unflattened mode with a 6 MV beam. On the Elekta VersaHD units the PVDR was measured to be between approximately 1.5 and 2.0 at 3 cm deep. For measurements with the orthovoltage unit PVDRs of greater than 10 were observed at a depth of 4 cm.Significance.The results confirmed that the predictions from simulation could be reproduced on linear accelerators currently in clinical usage, producing PVDRs between 2-2.5. Using the model to predict PVDRs using 1 MV photon beams, the threshold considered to produce enhanced normal tissue dose tolerance (>7) was surpassed. This suggests the possibility of using such techniques with versions of existing Linac technology which have been modified to operate at low energy and high beam currents.


Asunto(s)
Diseño de Equipo , Método de Montecarlo , Aceleradores de Partículas , Dosificación Radioterapéutica , Humanos , Fotones
3.
Radiother Oncol ; 196: 110318, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38702015

RESUMEN

BACKGROUND AND PURPOSE: The use of Stereotactic Body Radiation Therapy (SBRT) in lung cancer is increasing. However, there is no consensus on the most appropriate treatment planning and delivery practice for lung SBRT. To gauge the range of practice, quantify its variability and identify where consensus might be achieved, ESTRO surveyed the medical physics community. MATERIALS AND METHODS: An online survey was distributed to ESTRO's physicist membership in 2022, covering experience, dose and fractionation, target delineation, dose calculation and planning practice, imaging protocols, and quality assurance. RESULTS: Two-hundred and forty-four unique answers were collected after data cleaning. Most respondents were from Europe the majority of which had more than 5 years' experience in SBRT. The large majority of respondents deliver lung SBRT with the VMAT technique on C-arm Linear Accelerators (Linacs) employing daily pre-treatment CBCT imaging. A broad spectrum of fractionation schemes were reported, alongside an equally wide range of dose prescription protocols. A clear preference was noted for prescribing to 95% or greater of the PTV. Several issues emerged regarding the dose calculation algorithm: 22% did not state it while 24% neglected to specify the conditions under which the dose was calculated. Contouring was usually performed on Maximum or Average Intensity Projection images while dose was mainly computed on the latter. No clear indications emerged for plan homogeneity, complexity, and conformity assessment. Approximately 40% of the responders participated in inter-centre credentialing of SBRT in the last five years. Substantial differences emerged between high and low experience centres, with the latter employing less accurate algorithms and older equipment. CONCLUSION: The survey revealed an evident heterogeneity in numerous aspects of the clinical implementation of lung SBRT treatments. International guidelines and codes of practice might promote harmonisation.


Asunto(s)
Neoplasias Pulmonares , Radiocirugia , Planificación de la Radioterapia Asistida por Computador , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirugía , Radiocirugia/métodos , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Encuestas y Cuestionarios , Dosificación Radioterapéutica , Fraccionamiento de la Dosis de Radiación , Radioterapia de Intensidad Modulada/métodos , Europa (Continente)
4.
BJUI Compass ; 4(4): 464-472, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37334027

RESUMEN

Aims: Stereotactic ablative radiotherapy (SABR) for primary renal cell carcinoma (RCC) is a promising non-invasive ablative treatment option. A prospective interventional clinical trial published showed that treatment was feasible and well tolerated. We present the first single-institution UK cohort of patients with primary RCC receiving protocol-based SABR with prospective follow-up. We also present a protocol that could be used to facilitate more widespread use of the treatment. Materials and methods: Nineteen biopsy-proven primary RCC patients were treated with either 42 Gy in three fractions on alternate days or 26 Gy in a single fraction based on predefined eligibility criteria using either Linear Accelerator or CyberKnife platform. Prospective toxicity data using CTCAE V4.0 and outcome data such as estimated glomerular filtration rate (eGFR) and tumour response using CT thorax, abdomen and pelvis (CT-TAP) were collected at 6 weeks, 3, 6, 12, 18 and 24 months post treatment. Results: The 19 patients had a median age of 76 years (interquartile range [IQR] 64-82 years) and 47.4% were males, and they had a median tumour size of 4.5 cm (IQR 3.8-5.2 cm). Single and fractionated treatment was well tolerated and there were no significant acute side effects. The mean drop from baseline in eGFR at 6 months was 5.4 ml/min and that at 12 months was 8.7 ml/min. The overall local control rate at both 6 and 12 months was 94.4%. Overall survival at 6 and 12 months was 94.7% and 78.3%, respectively. After a median follow-up of 17 months, three patients experienced a Grade 3 toxicity, which was resolved with conservative management. Conclusion: SABR for primary RCC is a safe and feasible treatment for medically unfit patients, which can be delivered in most UK cancer centres using standard Linear Accelerator as well as CyberKnife platforms.

5.
Phys Med ; 35: 25-30, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28236559

RESUMEN

PURPOSE: External dosimetry audits give confidence in the safe and accurate delivery of radiotherapy. The RTTQA group have performed an on-site audit programme for trial recruiting centres, who have recently implemented static or rotational IMRT, and those with major changes to planning or delivery systems. METHODS: Measurements of reference beam output were performed by the host centre, and by the auditor using independent equipment. Verification of clinical plans was performed using the ArcCheck helical diode array. RESULTS: A total of 54 measurement sessions were performed between May 2014 and June 2016 at 28 UK institutions, reflecting the different combinations of planning and delivery systems used at each institution. Average ratio of measured output between auditor and host was 1.002±0.006. Average point dose agreement for clinical plans was -0.3±1.8%. Average (and 95% lower confidence intervals) of gamma pass rates at 2%/2mm, 3%/2mm and 3%/3mm respectively were: 92% (80%), 96% (90%) and 98% (94%). Moderately significant differences were seen between fixed gantry angle and rotational IMRT, and between combination of planning systems and linac manufacturer, but not between anatomical treatment site or beam energy. CONCLUSION: An external audit programme has been implemented for universal and efficient credentialing of IMRT treatments in clinical trials. Good agreement was found between measured and expected doses, with few outliers, leading to a simple table of optimal and mandatory tolerances for approval of dosimetry audit results. Feedback was given to some centres leading to improved clinical practice.


Asunto(s)
Ensayos Clínicos como Asunto/normas , Garantía de la Calidad de Atención de Salud , Radiometría/normas , Radioterapia de Intensidad Modulada/normas , Habilitación Profesional , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/normas , Radioterapia de Intensidad Modulada/instrumentación , Radioterapia de Intensidad Modulada/métodos , Reino Unido
6.
Br J Radiol ; 90(1071): 20160818, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27993093

RESUMEN

OBJECTIVE: Prostate dose painting radiotherapy requires the accurate identification of dominant intraprostatic lesions (DILs) to be used as boost volumes; these can be identified on multiparametric MRI (mpMRI) or choline positron emission tomography (PET)/CT. Planning scans are usually performed after 2-3 months of androgen deprivation therapy (ADT). We examine the effect of ADT on choline tracer uptake and boost volumes identified on choline PET/CT. METHODS: Fluoroethylcholine (18F choline) PET/CT was performed for dose painting radiotherapy planning in patients with intermediate- to high-risk prostate cancer. Initially, they were performed at planning. Owing to low visual tracer uptake, PET/CT for subsequent patients was performed at staging. We compared these two approaches on intraprostatic lesions obtained on PET using both visual and automatic threshold methods [prostate maximum standardized uptake value (SUVmax) 60%] when compared with mpMRI. RESULTS: PET/CT was performed during ADT in 11 patients (median duration of 85 days) and before ADT in 29 patients. ADT significantly reduced overall prostate volume by 17%. During ADT, prostate SUVmax was lower although it did not reach statistical significance (4.2 vs 6.6, p = 0.06); three patients had no visually identifiable PET DIL; and visually defined PET DILs were significantly smaller than corresponding mpMRI DILs (p = 0.03). However, all patients scanned before ADT had at least one visually identifiable PET DIL, with no significant size difference between MRI and visually defined PET DILs. In both groups, threshold PET produced larger DILs than visual PET. Both PET methods have moderate sensitivity (0.50-0.68) and high specificity (0.85-0.98) for identifying MRI-defined disease. CONCLUSION: For visual contouring of boost volumes in prostate dose painting radiotherapy, 18F choline PET/CT should be performed before ADT. For threshold contouring of boost volumes using our PET/CT scanning protocol, threshold levels of above 60% prostate SUVmax may be more suitable. Additional use of PET with MRI for radiotherapy planning can significantly change the overall boost volumes compared with using MRI alone. Advances in knowledge: For prostate dose painting radiotherapy, the additional use of 18F choline PET with MRI can significantly change the overall boost volumes, and PET should be performed before hormone therapy, especially if boost volumes are visually identified.


Asunto(s)
Colina/análogos & derivados , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Carga Tumoral , Anciano , Humanos , Masculino , Persona de Mediana Edad , Próstata/diagnóstico por imagen , Próstata/patología , Neoplasias de la Próstata/patología , Dosificación Radioterapéutica , Estudios Retrospectivos , Resultado del Tratamiento
7.
Radiother Oncol ; 109(3): 367-9, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24290533

RESUMEN

Contact radiotherapy uses small field sizes and very short SSDs to deliver low-energy X-rays very close to the position of a tumour. We present a Monte Carlo simulation of the Papillon contact radiotherapy machine, and in particular the backscatter factor, to investigate whether the factors given in current Codes of practice for kV dosimetry remain valid under these conditions.


Asunto(s)
Método de Montecarlo , Neoplasias/radioterapia , Neoplasias/cirugía , Planificación de la Radioterapia Asistida por Computador/métodos , Simulación por Computador , Humanos , Cuidados Intraoperatorios/instrumentación , Cuidados Intraoperatorios/métodos , Radiometría/instrumentación , Radiometría/métodos , Dispersión de Radiación
8.
Radiother Oncol ; 100(3): 453-5, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21955664

RESUMEN

Detectability and impact of potential treatment machine errors on IMRT treatments were evaluated. The ability of the gamma index to detect deliberately introduced errors was assessed and their clinical impact was assessed using Tumour Control Probability (TCP) and Normal Tissue Complication Probability. TCP was only marginally affected by 2mm errors in MLC position. Dose delivery errors had greater impact but were not detected as effectively using the gamma index. Acceptance criteria should include mean dose as well as gamma to help identify errors in the delivered dose.


Asunto(s)
Garantía de la Calidad de Atención de Salud , Radioterapia de Intensidad Modulada/normas , Algoritmos , Simulación por Computador , Relación Dosis-Respuesta en la Radiación , Humanos , Errores Médicos/prevención & control , Dosis de Radiación , Radiometría/normas , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Programas Informáticos