Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Phys Med Biol ; 62(20): 7938-7958, 2017 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-28858854

RESUMEN

Boron neutron capture therapy (BNCT) is a treatment modality that combines different radiation qualities. Since the severity of biological damage following irradiation depends on the radiation type, a quantity different from absorbed dose is required to explain the effects observed in the clinical BNCT in terms of outcome compared with conventional photon radiation therapy. A new approach for calculating photon iso-effective doses in BNCT was introduced previously. The present work extends this model to include information from dose-response assessments in animal models and humans. Parameters of the model were determined for tumour and precancerous tissue using dose-response curves obtained from BNCT and photon studies performed in the hamster cheek pouch in vivo models of oral cancer and/or pre-cancer, and from head and neck cancer radiotherapy data with photons. To this end, suitable expressions of the dose-limiting Normal Tissue Complication and Tumour Control Probabilities for the reference radiation and for the mixed field BNCT radiation were developed. Pearson's correlation coefficients and p-values showed that TCP and NTCP models agreed with experimental data (with r > 0.87 and p-values >0.57). The photon iso-effective dose model was applied retrospectively to evaluate the dosimetry in tumours and mucosa for head and neck cancer patients treated with BNCT in Finland. Photon iso-effective doses in tumour were lower than those obtained with the standard RBE-weighted model (between 10% to 45%). The results also suggested that the probabilities of tumour control derived from photon iso-effective doses are more adequate to explain the clinical responses than those obtained with the RBE-weighted values. The dosimetry in the mucosa revealed that the photon iso-effective doses were about 30% to 50% higher than the corresponding RBE-weighted values. While the RBE-weighted doses are unable to predict mucosa toxicity, predictions based on the proposed model are compatible with the observed clinical outcome. The extension of the photon iso-effective dose model has allowed, for the first time, the determination of the photon iso-effective dose for unacceptable complications in the dose-limiting normal tissue. Finally, the formalism developed in this work to compute photon-equivalent doses can be applied to other therapies that combine mixed radiation fields, such as hadron therapy.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Modelos Animales de Enfermedad , Neoplasias de Cabeza y Cuello/radioterapia , Melanoma/radioterapia , Neoplasias de la Boca/radioterapia , Mucositis/radioterapia , Fotones , Animales , Carcinoma de Células Escamosas/radioterapia , Cricetinae , Humanos , Lesiones Precancerosas/radioterapia , Radiometría
2.
Appl Radiat Isot ; 69(12): 1826-9, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21367606

RESUMEN

There has been increasing interest in combining Boron Neutron Capture Therapy (BNCT) with standard radiotherapy, either concomitantly or as a BNCT treatment of a recurrent tumor that was previously irradiated with a medical electron linear accelerator (LINAC). In this work we report the simulated dosimetry of treatments combining X-rays and BNCT.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Radioterapia , Humanos , Método de Montecarlo
3.
Appl Radiat Isot ; 67(7-8 Suppl): S50-3, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19375342

RESUMEN

As part of phase I/II melanoma BNCT clinical trial conducted in Argentina in a cooperative effort of the Argentine Atomic Energy Commission (CNEA) and the Oncology Institute Angel H. Roffo (IOAHR), 7 patients (6 female-1 male) received eight treatment sessions covering ten anatomical areas located in extremities. Mean age of the patients was 64 years (51-74). The treatments were performed between October 2003 and June 2007. All patients presented multiple subcutaneous skin metastases of melanoma and received an infusion containing approximately 14 gr/m(2) of (10)borophenyl-alanine (BPA) followed by the exposition of the area to a mixed thermal-epithermal neutron beam at the RA-6 reactor. The maximum prescribed dose to normal skin ranged from 16.5 to 24 Gy-Eq and normal tissue administered dose varied from 15.8 to 27.5 Gy-Eq. Considering evaluable nodules, 69.3% of overall response and 30.7% of no changes were seen. The toxicity was acceptable, with 3 out of 10 evaluable areas showing ulceration (30% toxicity grade 3).


Asunto(s)
Terapia por Captura de Neutrón de Boro/métodos , Melanoma/radioterapia , Neoplasias Cutáneas/radioterapia , Anciano , Argentina , Compuestos de Boro/uso terapéutico , Femenino , Humanos , Pierna , Masculino , Persona de Mediana Edad , Fenilalanina/análogos & derivados , Fenilalanina/uso terapéutico , Fármacos Sensibilizantes a Radiaciones/uso terapéutico , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
4.
Med Phys ; 35(4): 1295-8, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18491523

RESUMEN

A dosimetry intercomparison between the boron neutron capture therapy groups of the Massachusetts Institute of Technology (MIT) and the Comisión Nacional de Energía Atómica (CNEA), Argentina was performed to enable combined analyses of NCT patient data between the different centers. In-air and dose versus depth measurements in a rectangular water phantom were performed at the hyperthermal neutron beam facility of the RA-6 reactor, Bariloche. Calculated dose profiles from the CNEA treatment planning system NCTPlan that were calibrated against in-house measurements required normalizations of 1.0 (thermal neutrons), 1.13 (photons), and 0.74 (fast neutrons) to match the dosimetry of MIT.


Asunto(s)
Terapia por Captura de Neutrón de Boro/estadística & datos numéricos , Terapia por Captura de Neutrón de Boro/normas , Radiometría/estadística & datos numéricos , Argentina , Calibración , Humanos , Massachusetts , Radiometría/normas , Dosificación Radioterapéutica , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Appl Radiat Isot ; 61(5): 805-10, 2004 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15308148

RESUMEN

This work evaluates the performance of two NCT treatment planning systems: NCTPlan, developed by the CNEA and the Harvard-MIT group, and SERA, developed by the INEEL/Montana State University group. The study was performed in some simple geometries with the therapeutical hyperthermal beam of the RA-6 facility at Bariloche, Argentina. The first geometry was a rectangular phantom and calculations and measurements were made along the central beam axis and along a parellel axis, 4 cm apart from the central beam axis. Measurements and calculations were also performed in a cylindrical phantom, to explore the behavior of the treatment planning systems in a geometry simulating an extremity, in accordance with the CNEA clinical protocol. Comments on differences in source definitions and cross sections libraries are also included in the text. It can be seen that both codes give acceptable results on the central beam axis and on a lateral axis, showing good agreement with experimental results.


Asunto(s)
Terapia por Captura de Neutrón de Boro/instrumentación , Planificación de la Radioterapia Asistida por Computador , Argentina , Terapia por Captura de Neutrón de Boro/métodos , Terapia por Captura de Neutrón de Boro/estadística & datos numéricos , Neutrones Rápidos/uso terapéutico , Humanos , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...