1.
Sci Rep ; 11(1): 22079, 2021 11 11.
Artículo en Inglés | MEDLINE | ID: mdl-34764438

RESUMEN

Non-contact infrared thermometers (NCITs) are being widely used during the COVID-19 pandemic as a temperature-measurement tool for screening and isolating patients in healthcare settings, travelers at ports of entry, and the general public. To understand the accuracy of NCITs, a clinical study was conducted with 1113 adult subjects using six different commercially available NCIT models. A total of 60 NCITs were tested with 10 units for each model. The NCIT-measured temperature was compared with the oral temperature obtained using a reference oral thermometer. The mean difference between the reference thermometer and NCIT measurement (clinical bias) was different for each NCIT model. The clinical bias ranged from just under - 0.9 °C (under-reporting) to just over 0.2 °C (over-reporting). The individual differences ranged from - 3 to + 2 °C in extreme cases, with the majority of the differences between - 2 and + 1 °C. Depending upon the NCIT model, 48% to 88% of the individual temperature measurements were outside the labeled accuracy stated by the manufacturers. The sensitivity of the NCIT models for detecting subject's temperature above 38 °C ranged from 0 to 0.69. Overall, our results indicate that some NCIT devices may not be consistently accurate enough to determine if subject's temperature exceeds a specific threshold of 38 °C. Model-to-model variability and individual model accuracy in the displayed temperature were found to be outside of acceptable limits. Accuracy and credibility of the NCITs should be thoroughly evaluated before using them as an effective screening tool.


Asunto(s)
COVID-19 , Fiebre/diagnóstico , Termómetros , Adulto , Temperatura Corporal , COVID-19/diagnóstico , Femenino , Humanos , Rayos Infrarrojos , Masculino , Pandemias , Sensibilidad y Especificidad , Adulto Joven
2.
Sensors (Basel) ; 22(1)2021 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-35009758

RESUMEN

Infrared thermographs (IRTs) implemented according to standardized best practices have shown strong potential for detecting elevated body temperatures (EBT), which may be useful in clinical settings and during infectious disease epidemics. However, optimal IRT calibration methods have not been established and the clinical performance of these devices relative to the more common non-contact infrared thermometers (NCITs) remains unclear. In addition to confirming the findings of our preliminary analysis of clinical study results, the primary intent of this study was to compare methods for IRT calibration and identify best practices for assessing the performance of IRTs intended to detect EBT. A key secondary aim was to compare IRT clinical accuracy to that of NCITs. We performed a clinical thermographic imaging study of more than 1000 subjects, acquiring temperature data from several facial locations that, along with reference oral temperatures, were used to calibrate two IRT systems based on seven different regression methods. Oral temperatures imputed from facial data were used to evaluate IRT clinical accuracy based on metrics such as clinical bias (Δcb), repeatability, root-mean-square difference, and sensitivity/specificity. We proposed several calibration approaches designed to account for the non-uniform data density across the temperature range and a constant offset approach tended to show better ability to detect EBT. As in our prior study, inner canthi or full-face maximum temperatures provided the highest clinical accuracy. With an optimal calibration approach, these methods achieved a Δcb between ±0.03 °C with standard deviation (σΔcb) less than 0.3 °C, and sensitivity/specificity between 84% and 94%. Results of forehead-center measurements with NCITs or IRTs indicated reduced performance. An analysis of the complete clinical data set confirms the essential findings of our preliminary evaluation, with minor differences. Our findings provide novel insights into methods and metrics for the clinical accuracy assessment of IRTs. Furthermore, our results indicate that calibration approaches providing the highest clinical accuracy in the 37-38.5 °C range may be most effective for measuring EBT. While device performance depends on many factors, IRTs can provide superior performance to NCITs.


Asunto(s)
Temperatura Corporal , Termografía , Calibración , Fiebre , Humanos , Rayos Infrarrojos , Termómetros
3.
J Biomed Opt ; 25(9)2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32921005

RESUMEN

SIGNIFICANCE: Infrared thermographs (IRTs) have been used for fever screening during infectious disease epidemics, including severe acute respiratory syndrome, Ebola virus disease, and coronavirus disease 2019 (COVID-19). Although IRTs have significant potential for human body temperature measurement, the literature indicates inconsistent diagnostic performance, possibly due to wide variations in implemented methodology. A standardized method for IRT fever screening was recently published, but there is a lack of clinical data demonstrating its impact on IRT performance. AIM: Perform a clinical study to assess the diagnostic effectiveness of standardized IRT-based fever screening and evaluate the effect of facial measurement location. APPROACH: We performed a clinical study of 596 subjects. Temperatures from 17 facial locations were extracted from thermal images and compared with oral thermometry. Statistical analyses included calculation of receiver operating characteristic (ROC) curves and area under the curve (AUC) values for detection of febrile subjects. RESULTS: Pearson correlation coefficients for IRT-based and reference (oral) temperatures were found to vary strongly with measurement location. Approaches based on maximum temperatures in either inner canthi or full-face regions indicated stronger discrimination ability than maximum forehead temperature (AUC values of 0.95 to 0.97 versus 0.86 to 0.87, respectively) and other specific facial locations. These values are markedly better than the vast majority of results found in prior human studies of IRT-based fever screening. CONCLUSION: Our findings provide clinical confirmation of the utility of consensus approaches for fever screening, including the use of inner canthi temperatures, while also indicating that full-face maximum temperatures may provide an effective alternate approach.


Asunto(s)
Temperatura Corporal , Infecciones por Coronavirus/diagnóstico , Cara/fisiología , Fiebre/diagnóstico , Neumonía Viral/diagnóstico , Termografía/métodos , Adolescente , Adulto , Anciano , Área Bajo la Curva , Betacoronavirus , COVID-19 , Femenino , Humanos , Rayos Infrarrojos , Masculino , Tamizaje Masivo/métodos , Persona de Mediana Edad , Pandemias , Guías de Práctica Clínica como Asunto , Curva ROC , Reproducibilidad de los Resultados , SARS-CoV-2 , Adulto Joven
4.
J Biomed Mater Res B Appl Biomater ; 107(4): 1132-1140, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30184332

RESUMEN

Adequate cleaning of reusable medical devices is critical for preventing cross-infection among patients. For reusable medical devices, cleaning using mechanical brushes and detergent may not be sufficient to completely remove the infectious contaminants from the surfaces. This study evaluates the role of fluid flow-induced shear stress in the detachment and removal of contaminants from device surfaces. A stainless-steel test coupon, acting as a surrogate for a device surface, was coated with artificial clot of varying mass. The test coupon was exposed to fluid shear stress both with and without an enzymatic detergent. The relationship between clot removal quantity and the applied shear stress was obtained for multiple clot masses. Our results showed that fluid shear increased the effectiveness of the cleaning process. In the absence of flow, soaking the clot surface in the enzymatic detergent removed 67%, 77%, and 95% of the clot for 16 mg, 6.8 mg, and 1 mg initial masses, respectively. In the presence of fluid shear (0.3 Pa for 5 min), approximately 85%, 97%, and 99% of the clot was removed from the surface. The clot mass removed followed a linear relationship (R2 = 0.98) versus the applied fluid shear stress. This study showed that different cleaning processes such as fluid shear and detergent action contribute to the soil removal process. This method could be used to evaluate cleaning protocols for minimizing contaminant residue after the reprocessing of medical devices. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1132-1140, 2019.


Asunto(s)
Estrés Mecánico , Trombosis , Humanos , Propiedades de Superficie
5.
PLoS One ; 13(9): e0203302, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30231046

RESUMEN

Infrared (IR) modalities represent the only currently viable mass fever screening approaches for outbreaks of infectious disease pandemics such as Ebola virus disease and severe acute respiratory syndrome. Non-contact IR thermometers (NCITs) and IR thermographs (IRTs) have been used for fever screening in public areas such as airports. While NCITs remain a more popular choice than IRTs, there has been increasing evidences in the literature that IRTs can provide great accuracy in estimating body temperature if qualified systems are used and appropriate procedures are consistently applied. In this study, we addressed the issue of IRT qualification by implementing and evaluating a battery of test methods for objective, quantitative assessment of IRT performance based on a recent international standard (IEC 80601-2-59). We tested two commercial IRTs to evaluate their stability and drift, image uniformity, minimum resolvable temperature difference, and radiometric temperature laboratory accuracy. Based on these tests, we illustrated how experimental and data processing procedures could affect results, and suggested methods for clarifying and optimizing test methods. Overall, the insights into thermograph standardization and acquisition methods provided by this study may improve the utility of IR thermography and aid in comparing IRT performance, thus improving the potential for producing high quality disease pandemic countermeasures.


Asunto(s)
Fiebre/diagnóstico , Termografía/métodos , Termografía/normas , Aeropuertos , Enfermedades Transmisibles/diagnóstico , Enfermedades Transmisibles/epidemiología , Brotes de Enfermedades , Humanos , Rayos Infrarrojos , Tamizaje Masivo/métodos , Tamizaje Masivo/normas , Tamizaje Masivo/estadística & datos numéricos , Guías de Práctica Clínica como Asunto/normas , Termografía/estadística & datos numéricos , Termómetros
6.
Sensors (Basel) ; 18(1)2018 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-29300320

RESUMEN

Fever screening based on infrared (IR) thermographs (IRTs) is an approach that has been implemented during infectious disease pandemics, such as Ebola and Severe Acute Respiratory Syndrome. A recently published international standard indicates that regions medially adjacent to the inner canthi provide accurate estimates of core body temperature and are preferred sites for fever screening. Therefore, rapid, automated identification of the canthi regions within facial IR images may greatly facilitate rapid fever screening of asymptomatic travelers. However, it is more difficult to accurately identify the canthi regions from IR images than from visible images that are rich with exploitable features. In this study, we developed and evaluated techniques for multi-modality image registration (MMIR) of simultaneously captured visible and IR facial images for fever screening. We used free form deformation (FFD) models based on edge maps to improve registration accuracy after an affine transformation. Two widely used FFD models in medical image registration based on the Demons and cubic B-spline algorithms were qualitatively compared. The results showed that the Demons algorithm outperformed the cubic B-spline algorithm, likely due to overfitting of outliers by the latter method. The quantitative measure of registration accuracy, obtained through selected control point correspondence, was within 2.8 ± 1.2 mm, which enables accurate and automatic localization of canthi regions in the IR images for temperature measurement.


Asunto(s)
Fiebre , Algoritmos , Cara , Humanos , Tamizaje Masivo
7.
Open Biomed Eng J ; 4: 63-70, 2010 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-20448818

RESUMEN

This paper presents results of electromagnetic compatibility (EMC) testing of three implantable neurostimulators exposed to the magnetic fields emitted from several walk-through and hand-held metal detectors. The motivation behind this testing comes from numerous adverse event reports involving active implantable medical devices (AIMDs) and security systems that have been received by the Food and Drug Administration (FDA). EMC testing was performed using three neurostimulators exposed to the emissions from 12 walk-through metal detectors (WTMDs) and 32 hand-held metal detectors (HHMDs). Emission measurements were performed on all HHMDs and WTMDs and summary data is presented. Results from the EMC testing indicate possible electromagnetic interference (EMI) between one of the neurostimulators and one WTMD and indicate that EMI between the three neurostimulators and HHMDs is unlikely. The results suggest that worst case situations for EMC testing are hard to predict and testing all major medical device modes and setting parameters are necessary to understand and characterize the EMC of AIMDs.

8.
IEEE Trans Biomed Eng ; 54(9): 1679-86, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17867360

RESUMEN

This paper presents a magnetic-field system and the method developed for testing the immunity of the active implantable medical devices to continuous-wave magnetic fields in the frequency range up to 1 MHz. The system is able to produce magnetic fields of 150 A/m for frequencies up to 100 kHz and strengths decreasing as 1/f between 100 kHz and 1 MHz, with uniformity of the field within +/-2.5% in the volume for tests. To simulate human tissue, the medical device, together with its leads, is placed on a plastic grid in a saline tank that is introduced in the magnetic field of the induction coil. This paper offers an alternative for the injection voltage methods provided in the actual standards for assessing the protection of the implantable medical devices from the effects of the magnetic fields up to 1 MHz. This paper presents the equipment and signals used, the test procedure, and results from the preliminary tests performed at the Food and Drug Administration-Center for Devices and Radiological Health on implantable pacemakers and neurostimulators. The new system and test method are useful for the EMC research on the implantable medical devices.


Asunto(s)
Artefactos , Análisis de Falla de Equipo/instrumentación , Magnetismo/instrumentación , Prótesis e Implantes , Campos Electromagnéticos , Diseño de Equipo , Análisis de Falla de Equipo/métodos
9.
IEEE Trans Biomed Eng ; 52(3): 520-30, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15759582

RESUMEN

This paper describes a novel simulator to perform electromagnetic compatibility (EMC) tests for active implantable medical devices (AIMDs) with electromagnetic fields emitted by security systems. The security system simulator was developed in response to over 100 incident reports over 17 years related to the interference of AIMD's with security systems and the lack of a standardized test method. The simulator was evaluated regarding field homogeneity, signal distortion, and maximum magnetic field strength levels. Small three-axis probes and a three-axis scanning system were designed to determine the spatial and temporal characteristics of the fields emitted by 12 different types of walk through metal detectors (WTMDs). Tests were performed on four implanted pacemakers with a saline phantom and correlated to a newly developed test method performed "in air" (without the phantom). Comparison of the simulator thresholds with tests performed in real WTMDs showed that the simulator is able to mimic the pacemaker interference. The interference thresholds found in the simulator indicate that pulsed magnetic fields are more likely to cause interference in pacemakers than sinusoidal fields. The security system simulator will help biomedical engineers, manufacturers of medical devices, and manufacturers of security systems to identify incompatible combinations of WTMDs and AIMDs early in the development stage.


Asunto(s)
Campos Electromagnéticos , Análisis de Falla de Equipo/instrumentación , Análisis de Falla de Equipo/métodos , Marcapaso Artificial , Prótesis e Implantes , Medidas de Seguridad
10.
Phys Med Biol ; 48(15): 2551-60, 2003 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-12953914

RESUMEN

The finite difference time domain (FDTD) method in combination with a well established frequency scaling method was used to calculate the internal fields and current densities induced in a simple model of a pregnant woman and her foetus, when exposed to hand-held metal detectors. The pregnant woman and foetus were modelled using a simple semi-heterogeneous model in 10 mm resolution, consisting of three different types of tissue. The model is based on the scanned shape of a pregnant woman in the 34th gestational week. Nine different representative models of hand-held metal detectors operating in the frequency range from 8 kHz to 2 MHz were evaluated. The metal detectors were placed directly on the abdomen of the computational model with a spacing of 1 cm. Both the induced current density and the specific absorption rate (SAR) are well below the recommended limits for exposure of the general public published in the ICNIRP Guidelines and the IEEE C95.1 Standard. The highest current density is 8.3 mA m(-2) and the highest SAR is 26.5 microW kg(-1). Compared to the limits for the induced current density recommended in the ICNIRP Guidelines, a minimum safety factor of 3 exists. Compared to the IEEE C95. 1 Standard, a safety factor of 60 000 for the specific absorption rate was found. Based on the very low specific absorption rate and an induced current density below the recommended exposure limits, significant temperature rise or nerve stimulation in the pregnant woman or in the foetus can be excluded.


Asunto(s)
Feto/fisiología , Exposición Materna , Microondas , Modelos Biológicos , Protección Radiológica/métodos , Radiometría/métodos , Medidas de Seguridad , Anomalías Inducidas por Radiación/prevención & control , Carga Corporal (Radioterapia) , Simulación por Computador , Campos Electromagnéticos , Femenino , Humanos , Concentración Máxima Admisible , Embarazo , Dosis de Radiación , Radiometría/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA