Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Mult Scler ; 30(10): 1268-1277, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39234802

RESUMEN

BACKGROUND: Cerebrospinal fluid (CSF) oligoclonal bands (OCB) are a diagnostic biomarker in multiple sclerosis (MS). The central vein sign (CVS) is an imaging biomarker for MS that may improve diagnostic accuracy. OBJECTIVES: The objective of the study is to examine the diagnostic performance of simplified CVS methods in comparison to OCB in participants with clinical or radiological suspicion for MS. METHODS: Participants from the CentrAl Vein Sign in MS (CAVS-MS) pilot study with CSF testing were included. Select-3 and Select-6 (counting up to three or six CVS+ lesions per scan) were rated on post-gadolinium FLAIR* images. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value for Select-3, Select-6, OCB, and combinations thereof were calculated for MS diagnosis at baseline and at 12 months. RESULTS: Of 53 participants, 25 were OCB+. At baseline, sensitivity for MS diagnosis was 0.75 for OCB, 0.83 for Select-3, and 0.71 for Select-6. Specificity for MS diagnosis was 0.76 for OCB, 0.48 for Select-3, and 0.86 for Select-6. At 12 months, PPV for MS diagnosis was 0.95 for Select-6 and 1.00 for Select-6 with OCB+ status. DISCUSSION: Results suggest similar diagnostic performance of simplified CVS methods and OCB. Ongoing studies will refine whether CVS could be used in replacement or in conjunction with OCB.


Asunto(s)
Imagen por Resonancia Magnética , Esclerosis Múltiple , Bandas Oligoclonales , Humanos , Bandas Oligoclonales/líquido cefalorraquídeo , Adulto , Femenino , Masculino , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/líquido cefalorraquídeo , Persona de Mediana Edad , Proyectos Piloto , Sensibilidad y Especificidad , Biomarcadores/líquido cefalorraquídeo , Venas Cerebrales/diagnóstico por imagen , Valor Predictivo de las Pruebas
2.
Artículo en Inglés | MEDLINE | ID: mdl-39332906

RESUMEN

BACKGROUND AND PURPOSE: The central vein sign (CVS) is a proposed diagnostic imaging biomarker for multiple sclerosis (MS). The proportion of white matter lesions exhibiting the CVS (CVS+) is higher in patients with MS compared to its radiological mimics. Evaluation for CVS+ lesions in prior studies have been performed by manual rating, an approach that is time-consuming and has variable inter-rater reliability. Accurate automated methods would facilitate efficient assessment for CVS. The objective of this study was to compare the performance of an automated CVS detection method with manual rating for the diagnosis of MS. MATERIALS AND METHODS: 3T MRI was acquired in 86 participants undergoing evaluation for MS in a 9-site multicenter study. Participants presented with either typical or atypical clinical syndromes for MS. An automated CVS detection method was employed and compared to manual rating, including total CVS+ proportion and a simplified counting method in which experts visually identified up to 6 CVS+ lesions using FLAIR* contrast (a voxel-wise product of T2 FLAIR and post-contrast T2*-EPI images). RESULTS: Automated CVS processing was completed in 79 of 86 participants (91%), of whom 28 (35%) fulfilled the 2017 McDonald criteria at the time of imaging. The area under the receiver-operator characteristic curve (AUC) for discrimination between participants with and without MS for the automated CVS approach was 0.78 (95% confidence interval: [0.67,0.88]). This was not significantly different from simplified manual counting methods (select6*) (0.80 [0.69,0.91]) or manual assessment of total CVS+ proportion (0.89 [0.82,0.96]). In a sensitivity analysis excluding 11 participants whose MRI exhibited motion artifact, the AUC for the automated method was 0.81 [0.70,0.91], which was not statistically different from that for select6* (0.79 [0.68,0.92]) or manual assessment of total CVS+ proportion (0.89 [0.81,0.97]). CONCLUSIONS: Automated CVS assessment was comparable to manual CVS scoring for differentiating patients with MS from those with other diagnoses. Large, prospective, multicenter studies utilizing automated methods and enrolling the breadth of disorders referred for suspicion of MS are needed to determine optimal approaches for clinical implementation of an automated CVS detection method. ABBREVIATIONS: CVS= central vein sign; CVS+ = white matter lesions exhibiting the CVS; MRI = magnetic resonance imaging; MS = multiple sclerosis; T2 FLAIR = T2 fluid-attenuated inversion recovery; T2*-EPI = T2*-weighted 3D echo planar imaging; FLAIR* = a voxel-wise product of T2 FLAIR and post-contrast T2*-EPI images; select6* = simplified counting method in which experts visually identified up to 6 CVS+ lesions on FLAIR* imaging.

3.
Magn Reson Med ; 92(2): 702-714, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38525680

RESUMEN

PURPOSE: This study aimed to develop a new high-resolution MRI sequence for the imaging of the ultra-short transverse relaxation time (uT2) components in the brain, while simultaneously providing proton density (PD) contrast for reference and quantification. THEORY: The sequence combines low flip angle balanced SSFP (bSSFP) and UTE techniques, together with a 3D dual-echo rosette k-space trajectory for readout. METHODS: The expected image contrast was evaluated by simulations. A study cohort of six healthy volunteers and eight multiple sclerosis (MS) patients was recruited to test the proposed sequence. Subtraction between two TEs was performed to extract uT2 signals. In addition, conventional longitudinal relaxation time (T1) weighted, T2-weighted, and PD-weighted MRI sequences were also acquired for comparison. RESULTS: Typical PD-contrast was found in the second TE images, while uT2 signals were selectively captured in the first TE images. The subtraction images presented signals primarily originating from uT2 components, but only if the first TE is short enough. Lesions in the MS subjects showed hyperintense signals in the second TE images but were hypointense signals in the subtraction images. The lesions had significantly lower signal intensity in subtraction images than normal white matter (WM), which indicated a reduction of uT2 components likely associated with myelin. CONCLUSION: 3D isotropic sub-millimeter (0.94 mm) spatial resolution images were acquired with the novel bSSFP UTE sequence within 3 min. It provided easy extraction of uT2 signals and PD-contrast for reference within a single acquisition.


Asunto(s)
Encéfalo , Imagenología Tridimensional , Imagen por Resonancia Magnética , Esclerosis Múltiple , Humanos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Esclerosis Múltiple/diagnóstico por imagen , Adulto , Masculino , Femenino , Algoritmos , Persona de Mediana Edad , Procesamiento de Imagen Asistido por Computador/métodos , Interpretación de Imagen Asistida por Computador/métodos , Voluntarios Sanos , Simulación por Computador
4.
Neuroradiology ; 66(5): 653-675, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38507081

RESUMEN

Autoimmune encephalitis is a relatively novel nosological entity characterized by an immune-mediated damage of the central nervous system. While originally described as a paraneoplastic inflammatory phenomenon affecting limbic structures, numerous instances of non-paraneoplastic pathogenesis, as well as extra-limbic involvement, have been characterized. Given the wide spectrum of insidious clinical presentations ranging from cognitive impairment to psychiatric symptoms or seizures, it is crucial to raise awareness about this disease category. In fact, an early diagnosis can be dramatically beneficial for the prognosis both to achieve an early therapeutic intervention and to detect a potential underlying malignancy. In this scenario, the radiologist can be the first to pose the hypothesis of autoimmune encephalitis and refer the patient to a comprehensive diagnostic work-up - including clinical, serological, and neurophysiological assessments.In this article, we illustrate the main radiological characteristics of autoimmune encephalitis and its subtypes, including the typical limbic presentation, the features of extra-limbic involvement, and also peculiar imaging findings. In addition, we review the most relevant alternative diagnoses that should be considered, ranging from other encephalitides to neoplasms, vascular conditions, and post-seizure alterations. Finally, we discuss the most appropriate imaging diagnostic work-up, also proposing a suggested MRI protocol.


Asunto(s)
Enfermedades Autoinmunes del Sistema Nervioso , Encefalitis , Enfermedad de Hashimoto , Encefalitis Límbica , Humanos , Encefalitis/diagnóstico por imagen , Enfermedad de Hashimoto/diagnóstico por imagen , Autoanticuerpos , Convulsiones , Radiólogos , Encefalitis Límbica/diagnóstico por imagen
5.
Magn Reson Med ; 91(6): 2417-2430, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38291598

RESUMEN

PURPOSE: Recent work has shown MRI is able to measure and quantify signals of phospholipid membrane-bound protons associated with myelin in the human brain. This work seeks to develop an improved technique for characterizing this brain ultrashort- T 2 ∗ $$ {\mathrm{T}}_2\ast $$ component in vivo accounting for T 1 $$ {\mathrm{T}}_1 $$ weighting. METHODS: Data from ultrashort echo time scans from 16 healthy volunteers with variable flip angles (VFA) were collected and fitted into an advanced regression model to quantify signal fraction, relaxation time, and frequency shift of the ultrashort- T 2 ∗ $$ {\mathrm{T}}_2\ast $$ component. RESULTS: The fitted components show intra-subject differences of different white matter structures and significantly elevated ultrashort- T 2 ∗ $$ {\mathrm{T}}_2\ast $$ signal fraction in the corticospinal tracts measured at 0.09 versus 0.06 in other white matter structures and significantly elevated ultrashort- T 2 ∗ $$ {\mathrm{T}}_2\ast $$ frequency shift in the body of the corpus callosum at - $$ - $$ 1.5 versus - $$ - $$ 2.0 ppm in other white matter structures. CONCLUSION: The significantly different measured components and measured T 1 $$ {\mathrm{T}}_1 $$ relaxation time of the ultrashort- T 2 ∗ $$ {\mathrm{T}}_2\ast $$ component suggest that this method is picking up novel signals from phospholipid membrane-bound protons.


Asunto(s)
Encéfalo , Protones , Humanos , Voluntarios Sanos , Fantasmas de Imagen , Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Fosfolípidos
6.
Mult Scler ; 30(1): 25-34, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38088067

RESUMEN

BACKGROUND: The central vein sign (CVS) is a proposed magnetic resonance imaging (MRI) biomarker for multiple sclerosis (MS); the optimal method for abbreviated CVS scoring is not yet established. OBJECTIVE: The aim of this study was to evaluate the performance of a simplified approach to CVS assessment in a multicenter study of patients being evaluated for suspected MS. METHODS: Adults referred for possible MS to 10 sites were recruited. A post-Gd 3D T2*-weighted MRI sequence (FLAIR*) was obtained in each subject. Trained raters at each site identified up to six CVS-positive lesions per FLAIR* scan. Diagnostic performance of CVS was evaluated for a diagnosis of MS which had been confirmed using the 2017 McDonald criteria at thresholds including three positive lesions (Select-3*) and six positive lesions (Select-6*). Inter-rater reliability assessments were performed. RESULTS: Overall, 78 participants were analyzed; 37 (47%) were diagnosed with MS, and 41 (53%) were not. The mean age of participants was 45 (range: 19-64) years, and most were female (n = 55, 71%). The area under the receiver operating characteristic curve (AUROC) for the simplified counting method was 0.83 (95% CI: 0.73-0.93). Select-3* and Select-6* had sensitivity of 81% and 65% and specificity of 68% and 98%, respectively. Inter-rater agreement was 78% for Select-3* and 83% for Select-6*. CONCLUSION: A simplified method for CVS assessment in patients referred for suspected MS demonstrated good diagnostic performance and inter-rater agreement.


Asunto(s)
Esclerosis Múltiple , Adulto , Humanos , Femenino , Adulto Joven , Persona de Mediana Edad , Masculino , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Proyectos Piloto , Reproducibilidad de los Resultados , Venas , Imagen por Resonancia Magnética/métodos , Encéfalo/patología
7.
Proc Natl Acad Sci U S A ; 120(20): e2217635120, 2023 05 16.
Artículo en Inglés | MEDLINE | ID: mdl-37155847

RESUMEN

Myelin repair is an unrealized therapeutic goal in the treatment of multiple sclerosis (MS). Uncertainty remains about the optimal techniques for assessing therapeutic efficacy and imaging biomarkers are required to measure and corroborate myelin restoration. We analyzed myelin water fraction imaging from ReBUILD, a double-blind, randomized placebo-controlled (delayed treatment) remyelination trial, that showed a significant reduction in VEP latency in patients with MS. We focused on brain regions rich in myelin. Fifty MS subjects in two arms underwent 3T MRI at baseline and months 3 and 5. Half of the cohort was randomly assigned to receive treatment from baseline through 3 mo, whereas the other half received treatment from 3 mo to 5 mo post-baseline. We computed myelin water fraction changes occurring in normal-appearing white matter of corpus callosum, optic radiations, and corticospinal tracts. An increase in myelin water fraction was documented in the normal-appearing white matter of the corpus callosum, in correspondence with the administration of the remyelinating treatment clemastine. This study provides direct, biologically validated imaging-based evidence of medically induced myelin repair. Moreover, our work strongly suggests that significant myelin repair occurs outside of lesions. We therefore propose myelin water fraction within the normal-appearing white matter of the corpus callosum as a biomarker for clinical trials looking at remyelination.


Asunto(s)
Esclerosis Múltiple , Remielinización , Sustancia Blanca , Humanos , Cuerpo Calloso/diagnóstico por imagen , Cuerpo Calloso/patología , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/tratamiento farmacológico , Esclerosis Múltiple/patología , Encéfalo/patología , Vaina de Mielina/patología , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/patología , Imagen por Resonancia Magnética/métodos , Agua , Biomarcadores
8.
Ann Clin Transl Neurol ; 10(4): 536-552, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36744645

RESUMEN

OBJECTIVE: We explored the relationship between regional PRNP expression from healthy brain tissue and patterns of increased and decreased diffusion and regional brain atrophy in patients with sporadic Creutzfeldt-Jakob disease (sCJD). METHODS: We used PRNP microarray data from 6 healthy adult brains from Allen Brain Institute and T1-weighted and diffusion-weighted MRIs from 34 patients diagnosed with sCJD and 30 age- and sex-matched healthy controls to construct partial correlation matrices across brain regions for specific measures of interest: PRNP expression, mean diffusivity, volume, cortical thickness, and local gyrification index, a measure of cortical folding. RESULTS: Regional patterns of PRNP expression in the healthy brain correlated with regional patterns of diffusion signal abnormalities and atrophy in sCJD. Among different measures of cortical morphology, regional patterns of local gyrification index in sCJD most strongly correlated with regional patterns of PRNP expression. At the vertex-wise level, different molecular subtypes of sCJD showed distinct regional correlations in local gyrification index across the cortex. Local gyrification index correlation patterns most closely matched patterns of PRNP expression in sCJD subtypes known to have greatest pathologic involvement of the cerebral cortex. INTERPRETATION: These results suggest that the specific genetic and molecular environment in which the prion protein is expressed confer variable vulnerability to misfolding across different brain regions that is reflected in patterns of imaging findings in sCJD. Further work in larger samples will be needed to determine whether these regional imaging patterns can serve as reliable markers of distinct disease subtypes to improve diagnosis and treatment targeting.


Asunto(s)
Síndrome de Creutzfeldt-Jakob , Priones , Adulto , Humanos , Síndrome de Creutzfeldt-Jakob/diagnóstico por imagen , Síndrome de Creutzfeldt-Jakob/genética , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Proteínas Priónicas/genética
9.
Mult Scler ; 29(3): 363-373, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36573559

RESUMEN

BACKGROUND: Remote activity monitoring has the potential to evaluate real-world, motor function, and disability at home. The relationships of daily physical activity with spinal cord white matter and gray matter (GM) areas, multiple sclerosis (MS) disability and leg function, are unknown. OBJECTIVE: Evaluate the association of structural central nervous system pathology with ambulatory disability. METHODS: Fifty adults with progressive or relapsing MS with motor disability who could walk >2 minutes were assessed using clinician-evaluated, patient-reported outcomes, and quantitative brain and spinal cord magnetic resonance imaging (MRI) measures. Fitbit Flex2, worn on the non-dominant wrist, remotely assessed activity over 30 days. Univariate and multivariate analyses were performed to assess correlations between physical activity and other disability metrics. RESULTS: Mean age was 53.3 years and median Expanded Disability Status Scale (EDSS) was 4.0. Average daily step counts (STEPS) were highly correlated with EDSS and walking measures. Greater STEPS were significantly correlated with greater C2-C3 spinal cord GM areas (ρ = 0.39, p = 0.04), total cord area (TCA; ρ = 0.35, p = 0.04), and cortical GM volume (ρ = 0.32, p = 0.04). CONCLUSION: These results provide preliminary evidence that spinal cord GM area is a neuroanatomical substrate associated with STEPS. STEPS could serve as a proxy to alert clinicians and researchers to possible changes in structural nervous system pathology.


Asunto(s)
Médula Cervical , Personas con Discapacidad , Trastornos Motores , Esclerosis Múltiple , Adulto , Humanos , Persona de Mediana Edad , Esclerosis Múltiple/patología , Médula Cervical/patología , Médula Espinal/patología , Encéfalo/patología , Imagen por Resonancia Magnética , Caminata , Evaluación de la Discapacidad , Atrofia/patología
10.
AJR Am J Roentgenol ; 220(1): 115-125, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35975888

RESUMEN

BACKGROUND. The central vein sign (CVS) is a proposed MRI biomarker of multiple sclerosis (MS). The impact of gadolinium-based contrast agent (GBCA) administration on CVS evaluation remains poorly investigated. OBJECTIVE. The purpose of this study was to assess the effect of GBCA use on CVS detection and on the diagnostic performance of the CVS for MS using a 3-T FLAIR* sequence. METHODS. This study was a secondary analysis of data from the pilot study for the prospective multicenter Central Vein Sign: A Diagnostic Biomarker in Multiple Sclerosis (CAVS-MS), which recruited adults with suspected MS from April 2018 to February 2020. Participants underwent 3-T brain MRI including FLAIR and precontrast and post-contrast echo-planar imaging T2*-weighted acquisitions. Postprocessing was used to generate combined FLAIR and T2*-weighted images (hereafter, FLAIR*). MS diagnoses were established using the 2017 McDonald criteria. Thirty participants (23 women, seven men; mean age, 45 years) were randomly selected from the CAVS-MS pilot study cohort. White matter lesions (WMLs) were marked using FLAIR* images. A single observer, blinded to clinical data and GBCA use, reviewed marked WMLs on FLAIR* images for the presence of the CVS. RESULTS. Thirteen of 30 participants had MS. Across participants, on precontrast FLAIR* imaging, 218 CVS-positive and 517 CVS-negative WMLs were identified; on post-contrast FLAIR* imaging, 269 CVS-positive and 459 CVS-negative WMLs were identified. The fraction of WMLs that were CVS-positive on precontrast and postcontrast images was 48% and 58% in participants with MS and 7% and 10% in participants without MS, respectively. The median patient-level CVS-positivity rate on precontrast and postcontrast images was 43% and 67% for participants with MS and 4% and 8% for participants without MS, respectively. In a binomial model adjusting for MS diagnoses, GBCA use was associated with an increased likelihood of at least one CVS-positive WML (odds ratio, 1.6; p < .001). At a 40% CVS-positivity threshold, the sensitivity of the CVS for MS increased from 62% on precontrast images to 92% on postcontrast images (p = .046). Specificity was not significantly different between precontrast (88%) and postcontrast (82%) images (p = .32). CONCLUSION. GBCA use increased CVS detection on FLAIR* images, thereby increasing the sensitivity of the CVS for MS diagnoses. CLINICAL IMPACT. The postcontrast FLAIR* sequence should be considered for CVS evaluation in future investigational trials and clinical practice.


Asunto(s)
Esclerosis Múltiple , Enfermedades Vasculares , Adulto , Masculino , Humanos , Femenino , Persona de Mediana Edad , Esclerosis Múltiple/diagnóstico por imagen , Medios de Contraste , Estudios Prospectivos , Proyectos Piloto , Imagen por Resonancia Magnética/métodos , Encéfalo/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA