Cancer Radiother ; 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38937203

RESUMEN

PURPOSE: The purpose of this study was to assess if multicriteria optimization could limit interoperator variability in radiation therapy planning and assess if this method could contribute to target volume coverage and sparing of organ at risk for intensity-modulated curative radiation therapy of head and neck cancers. MATERIAL AND METHODS: We performed a retrospective analysis on 20 patients treated for an oropharyngeal or oral cavity squamous cell carcinoma. We carried out a comparative dosimetric study of manual plans produced with Precision® software, compared with the plans proposed using the multicriteria optimization method (RayStation®). We assessed interoperator reproducibility on the first six patients, and dosimetric contribution in sparing organs at risk using the multicriteria optimization method. RESULTS: Median age was 69 years, most lesions were oropharyngeal carcinoma (65%), and 35% lesions were stage T3. First, we obtained a high degree of similarity between the four operator measurements for each patient at the level of each organ. Intraclass correlation coefficients were greater than 0.85. Second, we observed a significant dosimetric benefit for contralateral parotid gland, homolateral and contralateral masseter muscles, homolateral and contralateral pterygoid muscles and for the larynx (P<0.05). For the contralateral parotid gland, the mean dose difference between the multicriteria optimization and manual plans was -2.0Gy (P=0.01). Regarding the larynx, the mean dose difference between the two plans was -4.6Gy (P<0.001). CONCLUSION: Multicriteria optimization is a reproducible technique and faster than manual optimization. It allows dosimetric advantages on organs at risk, especially for those not usually taken into consideration in manual dosimetry. This may lead to improved quality of life.

2.
Med Phys ; 47(8): 3669-3674, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32367534

RESUMEN

INTRODUCTION: The use of flattening filter free (FFF) beams generated by standard linear accelerators is increasing in the clinical practice. The radiation intensity peaked toward the beam central axis is properly managed in the optimization process of treatment planning through intensity modulation. Specific FFF parameters for profile analysis, as unflatness and slope for FFF beams, based on the renormalization factor concept has been introduced for quality assurance purposes. Recently, Halcyon, an O-ring based linear accelerator equipped with a 6 MV FFF beam only has been introduced by Varian. METHODS: Renormalization factors and related fit parameters according to Fogliata et al. ["Definition of parameters for quality assurance of FFF photon beams in radiation therapy," Med. Phys. 39, 6455-6464 (2012)] have been evaluated for the 6 MV FFF beam generated by Halcyon units. The Halcyon representative beam data provided by Varian were used. Dose fall-off at the field edges was matched with an unflattened beam generated by a 6 MV from a TrueBeam linac. Consistency of the results was evaluated against measurements on a clinical Halcyon unit, as well as a TrueBeam 6 MV FFF for comparison. RESULTS: The five parameters in the analytical equation for estimating the renormalization factor were determined with an R2 of 0.997. The comparison of the unflatness parameters between the Halcyon representative and hospital beam data was consistent within a range of 0.6%. Consistently with the computed parameters, the Halcyon profiles resulted in a less pronounced peak than TrueBeam. CONCLUSION: Renormalization factors and related fit parameters from the 6 MV FFF beam generated by the Varian Halcyon unit are provided.


Asunto(s)
Aceleradores de Partículas , Fotones , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
3.
Phys Med ; 32(10): 1225-1237, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27659008

RESUMEN

PURPOSE: The main focus of the current paper is the clinical implementation of a Monte Carlo based platform for treatment plan validation for Tomotherapy and Cyberknife, without adding additional tasks to the dosimetry department. METHODS: The Monte Carlo platform consists of C++ classes for the actual functionality and a web based GUI that allows accessing the system using a web browser. Calculations are based on BEAMnrc/DOSXYZnrc and/or GATE and are performed automatically after exporting the dicom data from the treatment planning system. For Cyberknife treatments of moving targets, the log files saved during the treatment (position of robot, internal fiducials and external markers) can be used in combination with the 4D planning CT to reconstruct the actually delivered dose. The Monte Carlo platform is also used for calculation on MRI images, using pseudo-CT conversion. RESULTS: For Tomotherapy treatments we obtain an excellent agreement (within 2%) for almost all cases. However, we have been able to detect a problem regarding the CT Hounsfield units definition of the Toshiba Large Bore CT when using a large reconstruction diameter. For Cyberknife treatments we obtain an excellent agreement with the Monte Carlo algorithm of the treatment planning system. For some extreme cases, when treating small lung lesions in low density lung tissue, small differences are obtained due to the different cut-off energy of the secondary electrons. CONCLUSIONS: A Monte Carlo based treatment plan validation tool has successfully been implemented in clinical routine and is used to systematically validate all Cyberknife and Tomotherapy plans.


Asunto(s)
Radiocirugia/estadística & datos numéricos , Radiocirugia/normas , Planificación de la Radioterapia Asistida por Computador/estadística & datos numéricos , Planificación de la Radioterapia Asistida por Computador/normas , Radioterapia de Intensidad Modulada/estadística & datos numéricos , Radioterapia de Intensidad Modulada/normas , Algoritmos , Fenómenos Biofísicos , Simulación por Computador , Femenino , Tomografía Computarizada Cuatridimensional , Humanos , Imagen por Resonancia Magnética , Masculino , Método de Montecarlo , Control de Calidad , Dosificación Radioterapéutica , Programas Informáticos