Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39052333

RESUMEN

INTRODUCTION: This article offers a systematic literature review (SLR) on the use of the MiniMed 780G automated insulin delivery system (MM780G) in people with type 1 diabetes (PwT1D) during Ramadan intermittent fasting. It also presents consensus recommendations on the use of MM780G during the Ramadan period. METHODS: The SLR was performed following PRISMA methodology. The recommendations resulted from a consensus-forming process involving a panel of experts. The process considered evidence found in the SLR as well as the expert opinions. RESULTS: In total, 6 studies were included in the SLR. The evidence and expert opinions led to recommendations related to a) pre-Ramadan counseling of MM780G users who plan to fast, b) suggested MM780G settings, meal announcement strategy and safety aspects during Ramadan (including a contingency plan), and c) post-Ramadan transition into and out of Eid-al-Fitr festivities. DISCUSSION: The SLR findings showed that the MM780G maintain glycemic control at target in PwT1D during Ramadan (meeting CGM-based clinical targets proposed by the International Consensus on Time-in-Range) while ensuring low rates of hypoglycemia and diabetic ketoacidosis. Automated insulin delivery also helps PwT1D fast more days of Ramadan compared to users of other less advanced modalities of treatment. Pre-Ramadan guidance on specific aspects of the MM780G along with IDF-DAR counseling guidelines are recommended. There is still a challenge with post-Iftar hyperglycemia, which could potentially be mitigated by following the recommendations outlined in this article.

2.
Diabetes Obes Metab ; 26(3): 937-949, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38151748

RESUMEN

AIM: To report on the effectiveness and safety of the MiniMed 780G automated insulin delivery system in real-world users during the month of Ramadan. MATERIALS AND METHODS: CareLink Personal data were extracted from MiniMed 780G system users from the Gulf region. Users were included if they had ≥10 days of sensor glucose data during the month of Ramadan 2022 as well as in the month before and after. For the main analysis, continuous glucose monitoring endpoints were aggregated per month and were reported by time of day (daytime: 05.31-18.00 h, and night-time). Additional analyses were performed to study the pace at which the algorithm adapts. RESULTS: Glycaemic control was well kept in the 449 included users (mean sensor glucose = 152.6 ± 18.7 mg/dl, glucose management indicator = 7.0 ± 0.4%, time in range = 70.7 ± 11.0%, time below 70 mg/dl = 2.3 ± 2.3%). Albeit some metrics differed from the month before (p < .0001 for all), absolute differences were very small and considered clinically irrelevant. During Ramadan, there was no increased risk of hypoglycaemia during daytime (time below 70 mg/dl = 2.3 ± 2.4%), time in range was highest during daytime (80.0 ± 10.7%, night: 60.4 ± 15.3%), while time above 180 mg/dl was highest during night-time (37.3 ± 16.3%, day: 17.7 ± 10.7%). The algorithm adapted immediately upon lifestyle change. CONCLUSION: The MiniMed 780G automated insulin delivery system is effective, safe and fast in adapting to the substantial changes that occur in the lifestyle of people with type 1 diabetes during Ramadan.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Humanos , Insulina/efectos adversos , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemia/inducido químicamente , Hipoglucemia/epidemiología , Hipoglucemia/prevención & control , Insulina Regular Humana/uso terapéutico , Sistemas de Infusión de Insulina/efectos adversos , Hipoglucemiantes/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...