Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Opt Express ; 29(2): 1371-1383, 2021 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-33726354

RESUMEN

We propose and experimentally demonstrate a modular microring laser (MML) cavity for sensing applications. The proposed MML permits much more design freedom compared with a traditional simple ring cavity by decoupling the performance parameters into several regions in the cavity. Thus, the different biosensor performance parameters can be optimized semi-independently limiting the need for trade-offs on the design of the biosensing device. The first generation MML has been fabricated and tested. A fiber-to-fiber slope efficiency of up to 1.2%, a temperature coefficient of 1.35 GHz/K and a 3σ limit of detection (LOD) of 3.1 × 10-7 RIU without averaging and 6.0 × 10-8 RIU with a 60 s averaging, has been measured for the MML sensor, which is a record-low LOD in on-chip ring cavity optical sensors. Further optimization is possible, capitalizing on the key advantage of the MML concept, namely the potential for designing the laser cavity to achieve the desired optimization goals.

2.
Opt Lett ; 44(24): 5937-5940, 2019 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-32628191

RESUMEN

Whispering gallery mode resonator lasers hold the promise of an ultralow intrinsic limit of detection. However, the widespread use of these devices for biosensing applications has been hindered by the complexity and lack of robustness of the proposed configurations. In this work, we demonstrate biosensing with an integrated microdisk laser. Al2O3doped with Yb3+ was utilized because of its low optical losses as well as its emission in the range 1020-1050 nm, outside the absorption band of water. Single-mode laser emission was obtained at a wavelength of 1024 nm with a linewidth of 250 kHz while the microdisk cavity was submerged in water. A limit of detection of 300 pM (3.6 ng/ml) of the protein rhS100A4 in urine was experimentally demonstrated, showing the potential of the proposed devices for biosensing.


Asunto(s)
Óxido de Aluminio/química , Técnicas Biosensibles/instrumentación , Dispositivos Laboratorio en un Chip , Rayos Láser , Iterbio/química
3.
Opt Express ; 24(12): 12635-50, 2016 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-27410285

RESUMEN

We demonstrate an integrated optical probe including an on-chip microlens for a common-path swept-source optical coherence tomography system. This common-path design uses the end facet of the silicon oxynitride waveguide as the reference plane, thus eliminating the need of a space-consuming and dispersive on-chip loop reference arm, thereby obviating the need for dispersion compensation. The on-chip micro-ball lens eliminates the need of external optical elements for coupling the light between the chip and the sample. The use of this lens leads to a signal enhancement up to 37 dB compared to the chip without a lens. The light source, the common-path arm and the detector are connected by a symmetric Y junction having a wavelength independent splitting ratio (50/50) over a much larger bandwidth than can be obtained with a directional coupler. The signal-to-noise ratio of the system was measured to be 71 dB with 2.6 mW of power on a mirror sample at a distance of 0.3 mm from the waveguide end facet. Cross-sectional OCT images of a layered optical phantom sample are demonstrated with our system. A method, based on an extended Fourier-domain OCT model, for suppressing ghost images caused by additional parasitic reference planes is experimentally demonstrated.

4.
Opt Express ; 23(17): 22414-23, 2015 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-26368211

RESUMEN

We demonstrate a fabrication procedure for the direct integration of micro-ball lenses on planar integrated optical channel waveguide chips with the aim to reduce the divergence of light that arises from the waveguide in both horizontal and vertical directions. Fabrication of the lenses is based on photoresist reflow which is a procedure that allows for the use of photolithography for careful alignment of the lenses with respect to the waveguides and enables mass production. We present in detail the design and fabrication procedures. Optical characterization of the fabricated micro-ball lenses demonstrates a good performance in terms of beam-size reduction and beam shape. The beam half divergence angle of 1544 nm light is reduced from 12.4 ° to 1.85 °.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA