Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Ann Pharm Fr ; 72(1): 22-7, 2014 Jan.
Artículo en Francés | MEDLINE | ID: mdl-24438665

RESUMEN

INTRODUCTION: The parenteral nutrition admixtures are manufactured with an automated compounding BAXA(®) Exacta-Mix 2400. A 48-hour assembly has been validated. To optimize time and cost, a weekly assembly was tested. MATERIALS AND METHODS: Assembly was made on the first day. Ten identical parenteral nutrition admixtures (different volumes and compositions) were produced each day. A macroscopic examination was done at D0, D7 and D14. Physicochemical controls (electrolytes determinations by atomic absorption spectrophotometry, osmolalities measurements) were performed. Microbiological tests included a filtration membrane sterility test (Steritest(®)) and a plate count agar environmental monitoring. RESULTS: All mixtures were considered stable. The 12 Steritest(®) (H24, H48, D7 and D14) did not show any bacterial or fungal contamination. No microorganism has been detected on the plate count agar at D4 and D7. Concerning the physicochemical parameters of each parental nutrition admixture, no significant difference (Wilcoxon test) with the first day was found. DISCUSSION AND CONCLUSIONS: The automated filling system BAXA(®) Exacta-Mix 2400 improves the quality and safety of production. According to these results, the weekly assembly is validated and permit to save time (80hours/year) and cost (40 000 euros on consumable/year).


Asunto(s)
Tecnología de Alimentos/métodos , Alimentos Formulados , Nutrición Parenteral , Automatización , Carga Bacteriana , Ahorro de Costo , Electrólitos/análisis , Filtración , Contaminación de Alimentos , Microbiología de Alimentos , Tecnología de Alimentos/instrumentación , Alimentos Formulados/análisis , Alimentos Formulados/economía , Alimentos Formulados/microbiología , Humanos , Concentración Osmolar , Medicina de Precisión , Espectrofotometría Atómica
2.
Ann Pharm Fr ; 71(6): 401-9, 2013 Nov.
Artículo en Francés | MEDLINE | ID: mdl-24206592

RESUMEN

INTRODUCTION: Initially, parenteral nutrition admixtures are produced by sterile filtration with a stability of 14 days This study was conducted to check the stability (physicochemical and microbiological) when automated compounding BAXA(®) EM 2400 is used. MATERIALS AND METHODS: Forty pockets corresponding to 10 patients have been manufactured in according to Good Manufacturing Practice. Macroscopic and physicochemical tests (determination of electrolytes by atomic absorption spectroscopy, osmolality and pH measurements) were performed at different times (D0, D7, D14). To complete these checks, the emulsions were analyzed (size, stability, optical microscopy) at D0 and D14. Finally, microbiological research (Bact-Alert(®), filtration membrane sterility tests Steritest(®) and plate count agar) was performed. RESULTS: No lipid cluster was observed with an optical microscope. Comparison of data observed for all controls showed no significant difference in the production of D0 by the Wilcoxon test. Microbiology (Bact-Alert filtration membrane sterility tests Steritest(®) and plate count agar) was negative for all samples. Consequently, all mixtures were considered stable. DISCUSSION AND CONCLUSIONS: The automated compounding BAXA(®) EM 2400 ensures quality and safety of production. The results of this study have shown stability and sterility of parenteral nutrition admixtures for 14 days.


Asunto(s)
Soluciones para Nutrición Parenteral/química , Soluciones para Nutrición Parenteral/normas , Nutrición Parenteral en el Domicilio/métodos , Bacterias/química , Técnicas Bacteriológicas , Estabilidad de Medicamentos , Emulsiones , Filtración , Servicios de Atención de Salud a Domicilio , Nutrición Parenteral , Esterilización
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA