Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 15659, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39013978

RESUMEN

The submarine volcano Hunga Tonga-Hunga Ha'apai erupted explosively on January 15, 2022, offering a unique opportunity to investigate interactions between the atmosphere and ionosphere caused by Lamb and Pekeris waves. However, the resonance of Pekeris waves has not been previously detected. In this study, we applied a multi-point monitoring approach focusing on the lower ionosphere and atmospheric electric field. Here we show observed oscillations of 100-200 s in manmade transmitter signals and the magnetic and atmospheric electric fields, which were caused by Pekeris waves. However, no corresponding changes with the period of 100-200 s in atmospheric pressure due to Pekeris waves were observed on the ground. A simulation of neutral wind revealed Pekeris waves oscillating near the mesopause, suggesting resonance. Therefore, the oscillation in atmospheric electric field is interpreted that the resonance in the lower ionosphere was projected onto the Earth's surface via a global electric circuit.

2.
Langmuir ; 27(9): 5456-63, 2011 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-21476527

RESUMEN

The colloidal stability of polymer-stabilized nanoparticles is critical for therapeutic use. However, phosphates in physiological media can induce polymer desorption and consequently flocculation. Colloidal characteristics of PEO-magnetite nanoparticles with different anchors for attaching PEO to magnetite were examined in PBS. The effects of the number of anchors, PEO molecular weight, and chain density were examined. It was observed that ammonium phosphonates anchored PEO to magnetite effectively in phosphate-containing solutions because of interactions between the phosphonates and magnetite. Additionally, a method to estimate the magnetite surface coverage was developed and was found to be critical to the prediction of colloidal stability. This is key to understanding how functionalized surfaces interact with their environment.


Asunto(s)
Diseño de Fármacos , Óxido Ferrosoférrico/química , Polietilenglicoles/química , Agua/química , Peso Molecular , Organofosfonatos/química , Propiedades de Superficie , Temperatura
3.
Phys Chem Chem Phys ; 12(34): 10073-80, 2010 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-20683528

RESUMEN

Electrogenerated chemiluminescence (ECL) of water-soluble core/shell CdSe/ZnS quantum dots (QDs) coated with carboxylated polyethylene glycol polymers ("Qdot 625") was investigated in aqueous solutions using 2-(dibutylamino)ethanol (DBAE) and tri-n-propylamine (TPrA) as ECL coreactants. In both cases, ECL emissions at glassy carbon (GC) electrode appeared at the same potential of approximately 0.80 V vs. Ag/AgCl (3.0 M KCl), which was approximately 200 and approximately 150 mV more positive compared with the oxidation potentials for DBAE (approximately +0.60 V vs. Ag/AgCl) and TPrA (approximately +0.65 V vs. Ag/AgCl), respectively. The ECL intensity, however, was significantly affected by the type and the concentration of the ECL coreactant used as well as the nature of the working electrode. Under the present experimental conditions, ECL from DBAE was approximately 17 times stronger than that from TPrA. The maximum ECL was obtained at GC electrode when [DBAE] approximately = 53 mM, where a ratio of 11:3:1 in ECL intensity was evaluated for GC, Au, and Pt electrodes, respectively. The ECL emission of the Qdot 625/DBAE system had an apparent peak value of approximately 625 nm that matched well the fluorescence data. The QD as a label for ECL-based immunoassays of C-reactive protein (CRP) was realized by covalent binding of avidin on its surface, which allowed biotinylated anti-CRP to be attached and interacted with solution-phase CRP and the anti-CRP linked to micro-sized magnetic beads. The newly formed sandwich type aggregates were separated magnetically from the solution matrix, followed by the ECL generation at partially transparent Au nanoparticle-coated ITO electrode or Au/CD electrode in the presence of DBAE. Much stronger ECL responses were observed from the Au/CD electrode, at which a dynamic range of 1.0-10.0 microg mL(-1) CRP and a limit of detection of 1.0 microg mL(-1) CRP were obtained, respectively.


Asunto(s)
Proteína C-Reactiva/análisis , Compuestos de Cadmio/química , Electricidad , Mediciones Luminiscentes/métodos , Puntos Cuánticos , Compuestos de Selenio/química , Sulfuros/química , Compuestos de Zinc/química , Absorción , Animales , Butilaminas/química , Proteína C-Reactiva/química , Bovinos , Electrodos , Etanol/análogos & derivados , Etanol/química , Oro/química , Humanos , Inmunoensayo , Oxidación-Reducción , Polietilenglicoles/química , Espectrometría de Fluorescencia , Agua/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA