Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
ArXiv ; 2023 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-37731656

RESUMEN

Computational hemodynamics models are becoming increasingly useful in the management and prognosis of complex, multiscale pathologies, including those attributed to the development of pulmonary vascular disease. However, diseases like pulmonary hypertension are heterogeneous, and affect both the proximal arteries and veins as well as the microcirculation. Simulation tools and the data used for model calibration are also inherently uncertain, requiring a full analysis of the sensitivity and uncertainty attributed to model inputs and outputs. Thus, this study quantifies model sensitivity and output uncertainty in a multiscale, pulse-wave propagation model of pulmonary hemodynamics. Our pulmonary circuit model consists of fifteen proximal arteries and twelve proximal veins, connected by a two-sided, structured tree model of the distal vasculature. We use polynomial chaos expansions to expedite the sensitivity and uncertainty quantification analyses and provide results for both the proximal and distal vasculature. Our analyses provide uncertainty in blood pressure, flow, and wave propagation phenomenon, as well as wall shear stress and cyclic stretch, both of which are important stimuli for endothelial cell mechanotransduction. We conclude that, while nearly all the parameters in our system have some influence on model predictions, the parameters describing the density of the microvascular beds have the largest effects on all simulated quantities in both the proximal and distal circulation.

2.
Ann Biomed Eng ; 51(11): 2528-2543, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37453977

RESUMEN

Computational models provide an efficient paradigm for integrating and linking multiple spatial and temporal scales. However, these models are difficult to parameterize and match to experimental data. Recent advances in both data collection and model analyses have helped overcome this limitation. Here, we combine a multiscale, biventricular interaction model with mouse data before and after left ventricular (LV) ischemia. Sensitivity analyses are used to identify the most influential parameters on pressure and volume predictions. The subset of influential model parameters are calibrated to biventricular pressure-volume loop data (n = 3) at baseline. Each mouse underwent left anterior descending coronary artery ligation, during which changes in fractional shortening and RV pressure-volume dynamics were recorded. Using the calibrated model, we simulate acute LV ischemia and contrast outputs at baseline and in simulated ischemia. Our baseline simulations align with the LV and RV data, and our predictions during ischemia complement recorded RV data and prior studies on LV function during myocardial infarction. We show that a model with both biventricular mechanical interaction and systems-level cardiovascular dynamics can quantitatively reproduce in-vivo data and qualitatively match prior findings from animal studies on LV ischemia.


Asunto(s)
Ventrículos Cardíacos , Corazón , Ratones , Animales , Función Ventricular Izquierda , Vasos Coronarios , Isquemia
3.
bioRxiv ; 2023 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-36747704

RESUMEN

Computational models provide an efficient paradigm for integrating and linking multiple spatial and temporal scales. However, these models are difficult to parameterize and match to experimental data. Recent advances in both data collection and model analyses have helped overcome this limitation. Here, we combine a multiscale, biventricular interaction model with mouse data before and after left ventricular (LV) ischemia. Sensitivity analyses are used to identify the most influential parameters on pressure and volume predictions. The subset of influential model parameters are calibrated to biventricular pressure-volume loop data (n=3) at baseline. Each mouse underwent left anterior descending coronary artery ligation, during which changes in fractional shortening and RV pressure-volume dynamics were recorded. Using the calibrated model, we simulate acute LV ischemia and contrast outputs at baseline and in simulated ischemia. Our baseline simulations align with the LV and RV data, and our predictions during ischemia complement recorded RV data and prior studies on LV function during myocardial infarction. We show that a model with both biventricular mechanical interaction and systems level cardiovascular dynamics can quantitatively reproduce in-vivo data and qualitatively match prior findings from animal studies on LV ischemia.

4.
Am J Physiol Heart Circ Physiol ; 324(3): H293-H304, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36637971

RESUMEN

Chronic stimulation of cardiac α1A-adrenergic receptors (α1A-ARs) improves symptoms in multiple preclinical models of heart failure. However, the translational significance remains unclear. Human engineered heart tissues (EHTs) provide a means of quantifying the effects of chronic α1A-AR stimulation on human cardiomyocyte physiology. EHTs were created from thin slices of decellularized pig myocardium seeded with human induced pluripotent stem cell (iPSC)-derived cardiomyocytes and fibroblasts. With a paired experimental design, EHTs were cultured for 3 wk, mechanically tested, cultured again for 2 wk with α1A-AR agonist A61603 (10 nM) or vehicle control, and retested after drug washout for 24 h. Separate control experiments determined the effects of EHT age (3-5 wk) or repeat mechanical testing. We found that chronic A61603 treatment caused a 25% increase of length-dependent activation (LDA) of contraction compared with vehicle treatment (n = 7/group, P = 0.035). EHT force was not increased after chronic A61603 treatment. However, after vehicle treatment, EHT force was increased by 35% relative to baseline testing (n = 7/group, P = 0.022), suggesting EHT maturation. Control experiments suggested that increased EHT force resulted from repeat mechanical testing, not from EHT aging. RNA-seq analysis confirmed that the α1A-AR is expressed in human EHTs and found chronic A61603 treatment affected gene expression in biological pathways known to be activated by α1A-ARs, including the MAP kinase signaling pathway. In conclusion, increased LDA in human EHT after chronic A61603 treatment raises the possibility that chronic stimulation of the α1A-AR might be beneficial for increasing LDA in human myocardium and might be beneficial for treating human heart failure by restoring LDA.NEW & NOTEWORTHY Chronic stimulation of α1A-adrenergic receptors (α1A-ARs) is known to mediate therapeutic effects in animal heart failure models. To investigate the effects of chronic α1A-AR stimulation in human cardiomyocytes, we tested engineered heart tissue (EHT) created with iPSC-derived cardiomyocytes. RNA-seq analysis confirmed human EHT expressed α1A-ARs. Chronic (2 wk) α1A-AR stimulation with A61603 (10 nM) increased length-dependent activation (LDA) of contraction. Chronic α1A-AR stimulation might be beneficial for treating human heart failure by restoring LDA.


Asunto(s)
Insuficiencia Cardíaca , Células Madre Pluripotentes Inducidas , Humanos , Animales , Porcinos , Agonistas Adrenérgicos/metabolismo , Agonistas Adrenérgicos/farmacología , Agonistas Adrenérgicos/uso terapéutico , Contracción Miocárdica , Células Madre Pluripotentes Inducidas/metabolismo , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/metabolismo , Miocitos Cardíacos/metabolismo , Receptores Adrenérgicos/metabolismo , Receptores Adrenérgicos/uso terapéutico , Receptores Adrenérgicos alfa 1/metabolismo
5.
Exp Mech ; 61(1): 229-235, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33776073

RESUMEN

BACKGROUND: Hemolysis in sickle cell disease (SCD) releases cell free hemoglobin, which scavenges nitric oxide (NO), leading to pulmonary vascular vasoconstriction, increased pulmonary vascular resistance (PVR), and the development of PH. However, PVR is only one component of right ventricular (RV) afterload. Whether sickled red blood cells increase the total RV afterload, including compliance and wave reflections, is unclear. OBJECTIVE: Patients with SCD and pulmonary hypertension (PH) have a significantly increased risk of sudden death compared to patients with SCD alone. Sickled red blood cells (RBCs) are fragile and lyse easily. Here, we sought to determine the acute effects of SCD RBCs and increased cell free hemoglobin on RV afterload. METHODS: Main pulmonary artery pressures and flows were measured in C57BL6 mice before and after exchanges of whole blood (~200 uL, Hct=45%) with an equal volume of SCD RBCs in plasma (Hct=45%) or cell free hemoglobin (Hb+) in solution. After transfusions, animals were additionally stressed with acute hypoxia (AH; 10% O2). RESULTS: SCD RBCs increased PVR only compared to control RBCs; cell free hemoglobin increased PVR and wave reflections. These increases in RV afterload increased further with AH. CONCLUSIONS: The release of cell free hemoglobin from fragile SCD RBCs in vivo increases the total RV afterload and may impair RV function more than the SCD RBCs themselves.

6.
J Appl Physiol (1985) ; 128(3): 514-522, 2020 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-31854245

RESUMEN

High-altitude pulmonary edema (HAPE), a reversible form of capillary leak, is a common consequence of rapid ascension to high altitude and a major cause of death related to high-altitude exposure. Individuals with a prior history of HAPE are more susceptible to future episodes, but the underlying risk factors remain uncertain. Previous studies have shown that HAPE-susceptible subjects have an exaggerated pulmonary vasoreactivity to acute hypoxia, but incomplete data are available regarding their vascular response to exercise. To examine this, seven HAPE-susceptible subjects and nine control subjects (HAPE-resistant) were studied at rest and during incremental exercise at sea level and at 3,810 m altitude. Studies were conducted in both normoxic (inspired Po2 = 148 Torr) and hypoxic (inspired Po2 = 91 Torr) conditions at each location. Here, we report an expanded analysis of previously published data, including a distensible vessel model that showed that HAPE-susceptible subjects had significantly reduced small distal artery distensibility at sea level compared with HAPE-resistant control subjects [0.011 ± 0.001 vs. 0.021 ± 0.002 mmHg-1; P < 0.001). Moreover, HAPE-susceptible subjects demonstrated constant distensibility over all conditions, suggesting that distal arteries are maximally distended at rest. Consistent with having increased distal artery stiffness, HAPE-susceptible subjects had greater increases in pulmonary artery pulse pressure with exercise, which suggests increased proximal artery stiffness. In summary, HAPE-susceptible subjects have exercise-induced increases in proximal artery stiffness and baseline increases in distal artery stiffness, suggesting increased pulsatile load on the right ventricle.NEW & NOTEWORTHY In comparison to subjects who appear resistant to high-altitude pulmonary edema, those previously symptomatic show greater increases in large and small artery stiffness in response to exercise. These differences in arterial stiffness may be a risk factor for the development of high-altitude pulmonary edema or evidence that consequences of high-altitude pulmonary edema are long-lasting after return to sea level.


Asunto(s)
Mal de Altura , Edema Pulmonar , Rigidez Vascular , Altitud , Humanos , Hipoxia , Arteria Pulmonar
7.
J Vet Intern Med ; 30(4): 925, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27311736
8.
Pulm Circ ; 5(2): 291-5, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26064453

RESUMEN

Compliance (C) and resistance (R) maintain a unique, inverse relationship in the pulmonary circulation, resulting in a constant characteristic time [Formula: see text] that has been observed in healthy subjects as well as patients with pulmonary arterial hypertension (PAH). However, little is known about the dependence of right ventricular (RV) function on the coupled changes in R and C in the context of this inverse relationship. We hypothesized three simple dependencies of RV ejection fraction (RVEF) on R and C. The first model (linear-R) assumes a linear RVEF-R relation; the second (linear-C) assumes a linear RVEF-C relation; and the third one combines the former two in a mixed linear model. We found that the linear-R model and the mixed linear model are in good agreement with clinical evidence. A conclusive validation of these models will require more clinical data. Longitudinal data in particular are needed to identify the time course of ventricular-vascular impairment in PAH. Simple models like the ones we present here, once validated, will advance our understanding of the mechanisms of RV failure, which could improve strategies to manage RV dysfunction in PAH.

9.
J Biomech Eng ; 137(4): 044501, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25587800

RESUMEN

Pulmonary arteries (PAs) distend to accommodate increases in cardiac output. PA distensibility protects the right ventricle (RV) from excessive increases in pressure. Loss of PA distensibility plays a critical role in the fatal progression of pulmonary arterial hypertension (PAH) toward RV failure. However, it is unclear how PA distensibility is distributed across the generations of PA branches, mainly because of the lack of appropriate in vivo methods to measure distensibility of vessels other than the large, conduit PAs. In this study, we propose a novel approach to assess the distensibility of individual PA branches. The metric of PA distensibility we used is the slope of the stretch ratio-pressure relationship. To measure distensibility, we combined invasive measurements of mean PA pressure with angiographic imaging of the PA network of six healthy female dogs. Stacks of 2D images of the PAs, obtained from either contrast enhanced magnetic resonance angiography (CE-MRA) or computed tomography digital subtraction angiography (CT-DSA), were used to reconstruct 3D surface models of the PA network, from the first bifurcation down to the sixth generation of branches. For each branch of the PA, we calculated radial and longitudinal stretch between baseline and a pressurized state obtained via acute embolization of the pulmonary vasculature. Our results indicated that large and intermediate PA branches have a radial distensibility consistently close to 2%/mmHg. Our axial distensibility data, albeit affected by larger variability, suggested that the PAs distal to the first generation may not significantly elongate in vivo, presumably due to spatial constraints. Results from both angiographic techniques were comparable to data from established phase-contrast (PC) magnetic resonance imaging (MRI) and ex vivo mechanical tests, which can only be used in the first branch generation. Our novel method can be used to characterize PA distensibility in PAH patients undergoing clinical right heart catheterization (RHC) in combination with MRI.


Asunto(s)
Ensayo de Materiales , Fenómenos Mecánicos , Arteria Pulmonar , Animales , Fenómenos Biomecánicos , Presión Sanguínea , Perros , Femenino , Imagen por Resonancia Magnética , Arteria Pulmonar/fisiología , Estrés Mecánico
10.
Am J Physiol ; 277(5): H2002-9, 1999 11.
Artículo en Inglés | MEDLINE | ID: mdl-10564157

RESUMEN

Extracellular matrix components must be degraded and resynthesized for vascular remodeling to occur. We hypothesized that the hemodynamic environment regulates activity of matrix metalloproteinases (MMPs), the primary agents for in vivo matrix degradation, during vascular remodeling in response to changes in transmural pressure and shear stress. Pathological hemodynamic conditions were reproduced in an ex vivo system in which we maintained porcine carotid arteries for 24 and 48 h. Total levels of MMP-2 and MMP-9 extracted from tissue homogenates and analyzed by SDS-PAGE zymography were stimulated by transmural pressure and were unaffected by shear stress changes. Degradation of two specific gelatinase substrates, gelatin and elastin, increased with increasing pressure, but the degradation was not affected by shear stress changes in tissue specimens analyzed using in situ zymography (gelatin) and fluorescent measurement of endogenous elastin degradation (elastin). Our results suggest that transmural pressure activates at least two members of the MMP family and that activity of these enzymes is accompanied by degradation of matrix components, effects that may be implicated in hypertensive vascular remodeling.


Asunto(s)
Presión Sanguínea/fisiología , Arterias Carótidas/fisiología , Animales , Arterias Carótidas/enzimología , Arterias Carótidas/metabolismo , Elastina/metabolismo , Activación Enzimática/fisiología , Matriz Extracelular/metabolismo , Gelatina/metabolismo , Gelatinasas/metabolismo , Metaloproteinasa 2 de la Matriz/metabolismo , Metaloproteinasa 9 de la Matriz/metabolismo , Estrés Mecánico , Porcinos
11.
J Biomech Eng ; 120(4): 437-45, 1998 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-10412413

RESUMEN

Performance of a cardiac assist device pumping chamber in counterpulsation was evaluated using numerical simulations of the unsteady, three-dimensional flow inside the chamber and an analytical model of the force required to eject and fill the chamber. The wall shear stress within the device was similarly computed and modeled. The analytical model was scaled to match the numerical results and then used to predict performance at physiological operating conditions. According to these models for a stroke volume of 70 ml, between 0.4 and 1.0 W is required for counterpulsation at a frequency of 1.33 Hz against a restorative spring, depending on the spring constant chosen. The power and the maximum force calculated are within the ranges a trained skeletal muscle is capable of providing. Shear stress predictions show that platelet activation in the absence of surface effects and hemolysis due to high shear are unlikely to occur with this design. Furthermore, vortices that develop in the chamber during filling are predicted to increase blood mixing and provide favorable washing of the chamber walls. A computational-analytical approach such as this may have potential to aid rapid performance evaluation of new devices and streamline the design optimization process.


Asunto(s)
Contrapulsación/instrumentación , Corazón Auxiliar/normas , Hemodinámica , Ensayo de Materiales/métodos , Modelos Cardiovasculares , Análisis Numérico Asistido por Computador , Diseño de Equipo , Corazón Auxiliar/efectos adversos , Hemólisis , Humanos , Activación Plaquetaria , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Reología , Estrés Mecánico , Volumen Sistólico
12.
J Electromyogr Kinesiol ; 7(1): 27-37, 1997 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20719689

RESUMEN

The electromyogram (EMG) signal has potential as an indicator of stimulated muscle fatigue in applications of functional electrical stimulation (FES). In particular, it could be used to detect near lower limb collapse due to the associated muscle fatigue in FES-aided standing systems and thereby prevent falling. Surface EMG measurement, however, is hampered by stimulation artifact during FES. Modified surface stimulation and EMG detection equipment were designed and built to minimize this artifact and to permit detection of the electrical signal generated by the muscle during contraction. Artifact reduction techniques included shorting stimulator output leads between stimulus pulses and limiting and blanking slew rate in the EMG processing stage. Isometric fatigue experiments were performed by stimulating the quadriceps muscle of 20 able-bodied (a total of 125 trials) and three spinal cord injured (18 trials) subjects. Fatigue-tracking performance indicators were derived from the root-mean-square (RMS) of the EMG amplitude and from the median frequency (MF) of the EMG power spectral content. The results demonstrate that reliable fatigue tracking indicators for practical FES applications will be difficult to obtain, but that amplitude-based measures in spinal cord injured subjects show promise.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...