Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
G Ital Cardiol (Rome) ; 19(9): 519-529, 2018 Sep.
Artículo en Italiano | MEDLINE | ID: mdl-30087514

RESUMEN

Transcatheter aortic valve implantation (TAVI) has revolutionized the management of patients with symptomatic severe aortic stenosis and has become the standard of care for inoperable patients and the preferred therapy for those at increased surgical risk with peculiar clinical and anatomic features. Technology advances, growing experience and accumulating data prompted the update of the 2011 Italian Society of Interventional Cardiology (SICI-GISE) position paper on institutional and operator requirements to perform TAVI. The main objective of this document is to provide a guidance to assess the potential of institutions and operators to initiate and maintain an efficient TAVI program.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Desarrollo de Programa/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/fisiopatología , Tecnología Biomédica/tendencias , Humanos , Italia , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación
2.
J Cardiovasc Med (Hagerstown) ; 10(2): 212-4, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19377387

RESUMEN

In patients with acute aortic dissection, an early diagnosis is essential to anticipate aortic rupture, cardiac tamponade, organ ischemia and improve surgical results. A specific blood laboratory marker able to rule out the presence of aortic dissection has not been identified yet. Recently, several studies suggested using D-dimers as a negative predicting test to rule out diagnosis of acute aortic dissection in patients presenting with chest pain. In 61 patients with confirmed aortic dissection, preoperative D-dimers were assayed and correlated with time from symptom onset and extension of the false lumen dissection (according with De Bakey classification). Abnormal D-dimers values were considered those being greater than 400 microg/l. D-dimers values were above 400 microg/l in 50 patients (82%) and below 400 microg/l in 11 patients (18%). There was no correlation between preoperative D-dimers values and time from symptoms onset (r = -0.232; P = 0.1). We found that D-dimers are not always elevated in patients presenting with acute aortic dissection. Given the potential devastating effects of denying the diagnosis of acute aortic dissection with consequent delay of adequate treatment, a word of caution regarding the negative predictive value of D-dimer test in the diagnosis of aortic dissection seems warranted.


Asunto(s)
Aneurisma de la Aorta/diagnóstico , Disección Aórtica/diagnóstico , Productos de Degradación de Fibrina-Fibrinógeno/análisis , Enfermedad Aguda , Adulto , Anciano , Disección Aórtica/sangre , Disección Aórtica/complicaciones , Aneurisma de la Aorta/sangre , Aneurisma de la Aorta/complicaciones , Biomarcadores/sangre , Dolor en el Pecho/sangre , Dolor en el Pecho/etiología , Reacciones Falso Negativas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Regulación hacia Arriba
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA