Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
2.
Rofo ; 188(3): 253-8, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26529265

RESUMEN

UNLABELLED: Typically both breast and prostate cancer present as tissue with decreased elasticity. Palpation is the oldest technique of tumor detection in both organs and is based on this principle. Thus an operator can grade a palpable mass as suspicious for cancer. Strain elastography as modern ultrasound technique allows the visualization of tissue elasticity in a color coded elastogram and can be understood as technical finger. The following article shows similarities and differences of ultrasound strain elastography in the diagnosis of breast and prostate cancer. KEY POINTS: • In prostata cancer elastography, in breast cancer B-mode is the primary sonographic search modality. • The diagnostic value of the search modalities change with increasing age.• A cut-off value for a strain ratio is hard to obtain in the elastography of the prostata, because there is no stabile reference tissue in the prostata.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/fisiopatología , Diagnóstico por Imagen de Elasticidad/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/fisiopatología , Ultrasonografía Mamaria/métodos , Módulo de Elasticidad , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino
3.
Rofo ; 187(5): 331-7, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25634690

RESUMEN

Technical fusion is defined as the ultrasound-guided navigation through a previously generated 3 D imaging dataset such as a computed tomography (CT) or magnetic resonance imaging (MRI). This technique allows for moving the fused CT/MRI datasets synchroneously with the real-time ultrasound in the same plane. Established and furthermore not yet described applications, the technical principles and the limitations of this promising technique will be introduced.


Asunto(s)
Puntos Anatómicos de Referencia/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Técnica de Sustracción , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía/métodos , Neoplasias Urológicas/diagnóstico , Puntos Anatómicos de Referencia/patología , Sistemas de Computación , Diseño de Equipo , Humanos , Imagen por Resonancia Magnética/instrumentación , Evaluación de la Tecnología Biomédica , Tomografía Computarizada por Rayos X/instrumentación , Ultrasonografía/instrumentación , Interfaz Usuario-Computador
4.
Biomed Res Int ; 2014: 180804, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24967334

RESUMEN

Palpation of organs is one of the oldest clinical examination techniques, for instance, if you think of the palpation of the breast or the digital rectal examination of the prostate, where hard palpable regions are suspicious for cancer. This is the basic principle of real-time elastography, an ultrasound technique, which is able to visualise tissue elasticity. Since prostate cancer features an increased stiffness due to the higher cell and vessel density than the normal surrounding tissue, real-time elastography has been used for several years for prostate cancer detection. This review introduces the different techniques of ultrasound elastography and furthermore summarises its limitations and potentials.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Humanos , Masculino
5.
Ultraschall Med ; 34(4): 382-7, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23023451

RESUMEN

PURPOSE: This study investigates the performance of a 3 D Ultrasound (US) system in imaging elbow and wrist nerves. MATERIALS AND METHODS: Twenty healthy volunteers with asymptomatic median, ulnar and radial nerves were prospectively investigated. Bilateral 3DUS scans of the elbows and wrists were acquired by using a commercially available US scanner (18 MHz, AplioXG, Toshiba) and stored as a 3 D volume by a dedicated software (CURE, Robarts Research Institute). Retrospectively, qualitative (image quality, atypical nerve location, findings potentially associated with compression neuropathy) and quantitative (cross-sectional area measurements) evaluations were performed. RESULTS: In all 200 nerves 3DUS was feasible (100%). Image quality was insufficient in 13.5% (25 ulnar nerve elbow, 2 radial nerve) and sonomorphology was not assessable in those nerves. Measurement of cross sectional areas was feasible in all nerves (100%). Median cross-sectional area (range) were: median nerve elbow 7 mm2 (6-9), radial nerve 3 mm2 (1-4), ulnar nerve elbow 8 mm2 (5-11), median nerve wrist 8 mm2 (5-10), and ulnar nerve wrist 4 mm2 (2-6). No significant changes in nerve cross-sectional area along each nerve was found. Ulnar nerve subluxation was found in 2 nerves (6.7%). No anconeus epitrochlearis muscle or osteophytes were found. CONCLUSION: 3DUS is a feasible method for assessing nerves of the upper extremity and has been shown to provide a good overview of the median, ulnar and radial nerve at the elbow and wrist, but is limited for evaluation of the ulnar nerve in the cubital tunnel. This technique enables reliable measurements at different locations along the nerve.


Asunto(s)
Brazo/inervación , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Nervio Mediano/diagnóstico por imagen , Nervio Radial/diagnóstico por imagen , Nervio Cubital/diagnóstico por imagen , Ultrasonografía/métodos , Codo/diagnóstico por imagen , Codo/inervación , Estudios de Factibilidad , Humanos , Posicionamiento del Paciente , Valores de Referencia , Sensibilidad y Especificidad , Muñeca/diagnóstico por imagen , Muñeca/inervación
6.
Radiologe ; 51(11): 938, 940-6, 2011 Nov.
Artículo en Alemán | MEDLINE | ID: mdl-22083309

RESUMEN

CLINICAL/METHODOLOGICAL ISSUE: Prostate cancer is the most common cancer in men. The diagnosis is based on prostate-specific antigen (PSA), digital rectal examination (DRE) and transrectal ultrasound (TRUS) guided biopsy. These techniques have considerable limitations, which result in unnecessary biopsies. Furthermore the biopsies are associated with morbidity and costs. STANDARD RADIOLOGICAL METHODS: Standard gray-scale ultrasound has a low sensitivity and specificity for prostate cancer detection. METHODOLOGICAL INNOVATIONS: New ultrasound technologies, including color- and power Doppler ultrasound, contrast enhanced US and real-time sonoelastography have shown to improve prostate cancer diagnosis. PERFORMANCE: Contrast-enhanced ultrasound has shown a sensitivity of 100% (95% CI, 95%), a negative predictive value (NPV) of 99.8% and a positive predictive value (PPV) of 88.8% for prostate cancer detection. Real-time sonoelastography has shown a sensitivity of 86%, a specificity of 81% and NPV of 91% for prostate cancer diagnosis. ACHIEVEMENTS: Most studies show that these new ultrasound modalities demonstrate a 1.5 to 2.5 times higher detection of prostate cancer per biopsy specimen compared with systematic biopsy. Multicenter studies results are at present lacking but are, however ongoing. PRACTICAL RECOMMENDATIONS: In patients with suspected prostate cancer (elevated PSA, suspicious DRE) these new ultrasound techniques should be used. These techniques can detect prostate cancer and allow a targeted biopsy approach.


Asunto(s)
Aumento de la Imagen/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Ultrasonografía/instrumentación , Ultrasonografía/métodos , Humanos , Masculino , Ultrasonografía/tendencias
7.
Ultraschall Med ; 32 Suppl 1: S117-23, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20414859

RESUMEN

PURPOSE: To analyze the effectiveness and complication rate of ultrasound (US)-guided perforation and lavage using a two-needle technique with 16 - 18 G needles in the treatment of patients with calcific tendinopathy in the shoulder, elbow, hip, and knee by radiological and clinical follow-up. MATERIALS AND METHODS: A retrospective chart review was performed and 40 patients (13 male, 27 female; mean age, 53.5 years; range 24 -74 years) were identified as having received US-guided perforation and lavage due to symptomatic calcific tendinopathy of the rotator cuff tendons, triceps, extensor and flexor tendons at the elbow, rectus femoris tendon and patellar tendons. The radiographic outcome was assessed by comparison of the size and quality of the calcification before and 6 weeks after the procedure. On US images, the quality of the acoustic shadow was assessed, together with other alterations of the tendon and surrounding tissue. Patients were interviewed by telephone to assess the clinical outcome regarding pre-treatment and post-treatment pain and tendon function. RESULTS: 34 shoulder tendons and 6 non-shoulder tendons were identified. The mean calcium reduction was 39.9 mm(2) (range, 0 - 215; p < 0.001), while 80 % of patient showed a resolution of more than 60 % resulting in good clinical improvement. A very low complication rate was found (1 partial tear). CONCLUSION: The US-guided perforation and lavage technique is an effective and safe treatment for rotator cuff calcifications as well as for other body tendons. Although the two-needle technique and large needles were used in this study, a very low complication rate was detected.


Asunto(s)
Calcinosis/diagnóstico por imagen , Calcinosis/cirugía , Síndrome de Abducción Dolorosa del Hombro/diagnóstico por imagen , Síndrome de Abducción Dolorosa del Hombro/cirugía , Tendinopatía/diagnóstico por imagen , Tendinopatía/cirugía , Ultrasonografía Intervencional/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Agujas , Punciones/instrumentación , Estudios Retrospectivos , Manguito de los Rotadores/diagnóstico por imagen , Manguito de los Rotadores/cirugía , Tendones/diagnóstico por imagen , Tendones/cirugía , Irrigación Terapéutica , Ultrasonografía Intervencional/instrumentación
8.
Ultraschall Med ; 31(4): 394-400, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19946833

RESUMEN

PURPOSE: Real-time sonoelastography (SE), a newly introduced ultrasound technique, has already shown conclusive results in breast, prostate, and thyroid tumor diagnostics. This study investigated the performance of SE for the differentiation of Achilles tendon alterations of tendinopathy compared to clinical examination and conventional ultrasound (US). MATERIALS AND METHODS: Achilles tendons in 25 consecutive patients with chronic Achilles tendinopathy and 25 healthy volunteers were examined clinically by US and by SE. RESULTS: In the healthy volunteers, SE showed the tendon to be hard (93 %), while distinct softening was found in 57 % of the patients. SE showed more frequent involvement of the distal (64 %) and middle third (80 %) than the proximal third (28 %) of the Achilles tendon. Using SE a mean sensitivity of 94 %, specificity of 99 %, and accuracy of 97 % were found when clinical examination was used as the reference standard. The correlation to US was 0.89. Mild softening was found in 7 % of the healthy volunteers and in 11 % of the patients. CONCLUSION: Our results emphasize that only distinct softening of Achilles tendons is comparable to clinical examination and US findings. However, mild softening might be explained by very early changes in tissue elasticity in the case of Achilles tendinopathy, which should be assessed in follow-up studies.


Asunto(s)
Tendón Calcáneo/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Tendinopatía/diagnóstico por imagen , Adulto , Artritis Reumatoide/diagnóstico por imagen , Trastornos de Traumas Acumulados/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Estudios Prospectivos , Valores de Referencia , Sensibilidad y Especificidad , Espondilitis Anquilosante/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...