Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Semin Thromb Hemost ; 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-39151905

RESUMEN

External quality assessment (EQA) is used to evaluate laboratory performance in tests of hemostasis; however, some esoteric tests are performed by too few centers in any one EQA program to allow valid statistical assessment. To explore the feasibility of pooling data from several EQA providers, an exercise was carried out by the External Quality Assurance in Thrombosis and Haemostasis group, using the International Society on Thrombosis and Haemostasis Scientific and Standardization Committee (SSC) plasma standard for thrombophilia screening assays. Six EQA providers took part in this exercise, distributing the SSC plasma standard as a "blinded" sample to participants for thrombophilia tests between November 2020 and December 2021. Data were collected by each provider, anonymized, and pooled for analysis. Results were analyzed as overall results from each EQA provider, and by kit/method-specific comparisons of data from all providers pooled together. For each parameter, median results and range were determined. Over 1,250 sets of data were returned in the six EQA programs. The overall medians (all data pooled) were <4% of the assigned values for each parameter with the exception of protein C activity by clot-based assay. Method-related differences in median results were observed for free protein S antigen and protein S activity-a pattern seen across data from the different EQA providers. Antithrombin antigen results reported in mg/dL provided an example where small numbers of results for a single EQA provider may be supplemented by pooling data from multiple providers with good agreement seen among results reported by the different EQA providers. This study demonstrated that a multicenter EQA provider collaboration can be carried out and demonstrated benefit for assays with smaller number of participants. In addition, results showed good agreement with the assigned values of the SSC plasma standard. Further exercises for tests performed by only small numbers of laboratories can be planned.

2.
Int J Lab Hematol ; 46(4): 731-740, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38644463

RESUMEN

INTRODUCTION: Direct oral anticoagulants (DOACs) reflect anticoagulation agents given to treat or prevent thrombosis, having largely replaced vitamin K antagonists (VKAs) such as warfarin. DOACs are given in fixed daily doses and generally do not need monitoring. However, there may be a variety of reasons that justify measurement of plasma DOAC levels in individual patients. METHODS: We report updated findings for DOAC testing in our geographic region, using recent data from the RCPAQAP, an international external quality assessment (EQA) program, currently with some 40-60 participants in each of the different DOAC (rivaroxaban, apixaban, dabigatran) modules, to assess laboratory performance in this area. Data has been assessed for the past 5 years (2019-2023 inclusive), with 20 samples each per DOAC. RESULTS: Data shows a limited repertoire of assays in use, and mostly consistency in reported numerical values when assessing proficiency samples. Available assays mostly comprised reagents from four manufacturing suppliers. There was good consistency across what participants identified as 'DOAC detected', but some variability when participants attempted to grade DOAC levels as low vs moderate vs high. Inter-laboratory/method coefficient of variation (CVs) were generally <15% for each DOAC, when present at >100 ng/mL. CONCLUSION: We hope our findings, reflecting on mostly consistent reporting of DOAC levels and interpretation provides reassurance for clinicians requesting these measurements, and helps support their implementation in regions where there is a paucity of test availability.


Asunto(s)
Anticoagulantes , Humanos , Administración Oral , Anticoagulantes/administración & dosificación , Pruebas de Coagulación Sanguínea/normas , Pruebas de Coagulación Sanguínea/métodos , Hemostasis/efectos de los fármacos , Rivaroxabán/sangre , Piridonas/administración & dosificación , Australasia , Dabigatrán , Monitoreo de Drogas/métodos , Monitoreo de Drogas/normas , Pirazoles/uso terapéutico , Pirazoles/administración & dosificación , Pirazoles/sangre
3.
Semin Thromb Hemost ; 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38428840

RESUMEN

D-dimers represent the breakdown products of fibrin. Thus, elevated plasma D-dimers will arise following a thrombotic event, such as a deep vein thrombosis or a pulmonary embolism, and therefore, a nonelevated D-dimer is used to effectively exclude such events. D-dimers are also elevated in a range of other conditions, for example, during disseminated intravascular coagulation. D-dimer levels may also be associated with prognostic value. For example, highly raised D-dimer levels can be associated with worsening clinical features in coronavirus disease 2019. Thus, D-dimer testing represents a commonly requested hemostasis test, often performed in 24/7 laboratories. Unfortunately, D-dimer testing is neither standardized nor harmonized across manufacturers or laboratories. Indeed, considering reporting units and the magnitude of units, up to 28 different combinations may be reported by laboratories. We provide updated findings for D-dimer testing in our geographic region, using recent data from the Royal College of Pathologists of Australasia Quality Assurance Programs, an international external quality assessment program, currently with over 450 participants in the D-dimer module. Data show a wide variety of assays in use and variable outcomes in reported numerical values when assessing proficiency samples. D-dimer testing mostly comprised reagents from three main manufacturing suppliers, with a small number of users of reagents from other manufacturers. Reported results showed important differences in numerical values for the same homogeneous tested samples when normalized to a single reporting unit (e.g., mg/L). Nevertheless, despite using different test reagents and reporting, most participants uniformly identified D-dimer values as below or above a "detection" cut-off for samples that were constructed to be below or above most cut-off values. As expected, mixed findings were reported for samples containing levels around expected cut-off values. We hope that our findings, reflecting on the heterogeneity of test reagents and test data, help improve diagnostic testing for D-dimer testing and facilitate harmonization and standardization, in the future.

4.
Semin Thromb Hemost ; 2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-37967835

RESUMEN

Lupus anticoagulant (LA) is one of three tests identified as laboratory criteria for definite antiphospholipid syndrome (APS). The other two tests are anticardiolipin antibody (aCL) and anti-ß2-glycoprotein I (aß2GPI) antibody. The presence of LA is assessed using clot-based tests, while the presence of aCL and aß2GPI is assessed by immunological assays. Since no test can be considered 100% sensitive or specific for LA, current guidelines recommend using two different clot-based assays reflecting different principles, with the dilute Russell viper venom time (dRVVT) and activated partial thromboplastin time (aPTT) recommended. Initially, LA-sensitive reagents are used to screen for LA, and then, in "screen-positive" samples, LA-"insensitive" reagents are used to confirm LA. Because LA assays are based on clot detection, anything that can interfere with fibrin clot development may affect test results. In particular, in addition to LA, the tests are also sensitive to the presence of a wide range of clinical anticoagulants, reflecting preanalytical issues for testing. We provide updated findings for LA testing in our geographic region, using recent data from the Royal College of Pathologists of Australasia Quality Assurance Programs, an international external quality assessment program with approximately 120 participants. Data show a wide variety of assays in use, especially for aPTT testing, and variable outcomes in reported numerical values with these assays when assessing proficiency samples. dRVVT testing mostly comprised reagents from three main manufacturing suppliers, which also showed differences in numerical values for the same homogeneous tested samples. Nevertheless, despite the use of different test reagents and processes, >98% of participants correctly identified LA-negative samples as LA-negative and LA-positive samples as LA positive. We hope our findings, reflecting on the heterogeneity of test processes and test data, help improve diagnostic testing for LA in the future.

5.
Semin Thromb Hemost ; 48(6): 711-731, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35803263

RESUMEN

von Willebrand disease (VWD) is a common bleeding disorder that arises from deficiency and/or defects of von Willebrand factor (VWF). Appropriate diagnosis of VWD, including differential identification of qualitative (types 2A, 2B, 2M, 2N VWD) versus quantitative (types 1 and 3 VWD) defects remains problematic but has important management implications, given differential therapy. Complete assessment for VWD in a patient with a bleeding history requires comprehensive test panels, including VWF activity and antigen. We describe the Australasian experience, using data from the Royal College of Pathologists of Australasia (RCPA) Quality Assurance Program (QAP) related to VWF testing in their VWD test module. The RCPAQAP has been providing samples for VWF testing since 1998, representing 25 years of proficiency testing related to VWD diagnosis. A total of 109 samples have been dispatched to participants over these years, with current assessment involving dispatches of two samples (=4 samples) per year. Samples have represented all types of VWD, as well as normal or other samples, including acquired von Willebrand syndrome and plasma VWF concentrates as used in VWD therapy. Different VWF assays and activity/antigen ratios show different utility in VWD and type identification. In the past 9 years of data capture, a total of 166 errors were identified from a total of 1,839 interpretations, representing a base error rate of 9.0%. Identification errors were highest for type 2 VWD samples (15.3%), intermediate for type 1 VWD samples (7.5%), and lowest for normal samples (2.4%). Errors can be linked to assay limitations, including assay variability and low-level VWF detection limits, as well as laboratory issues (including test result misinterpretation, which accounts for approximately 40% of all errors for type 2 VWD). For test-associated errors, VWF:RCo and VWF:GPIbM were associated with the highest variability and error rate, which was up to 10x higher than that using VWF:CB. As a test group, chemiluminescence-based procedures were associated with lowest inter-laboratory variability, best low-level VWF detection (down to <1 U/dL), and least errors overall. These findings inform on reasons behind high rates of errors associated with VWD diagnosis, with some assays and methodologies performing substantially better than others.


Asunto(s)
Enfermedad de von Willebrand Tipo 2 , Enfermedades de von Willebrand , Pruebas de Coagulación Sanguínea , Técnicas de Laboratorio Clínico , Humanos , Enfermedades de von Willebrand/diagnóstico , Factor de von Willebrand
6.
Pathology ; 54(3): 308-317, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34556362

RESUMEN

von Willebrand disease (VWD) arises from deficiency and/or defects of von Willebrand factor (VWF). Assessment requires test panels, including VWF activity and antigen. Appropriate diagnosis including differential identification of qualitative versus quantitative defects remains problematic but has important management implications. Data using a large set (n=27) of varied plasma samples comprising both quantitative VWF deficiency ('Type 1 and 3') vs qualitative defects ('Type 2') tested in a cross-laboratory setting have been evaluated to assess contemporary VWF assays for utility to differentially identify sample types. Different VWF assays and activity/antigen ratios showed different utility in VWD and type identification. Identification errors were linked to assay limitations, including variability, and laboratory issues (e.g., test result misinterpretation). Quantitative deficient (type 1) samples were misinterpreted as qualitative defects (type 2) on 35/467 occasions (7.5% error rate); 11.4% of these errors were due to laboratories misinterpreting their own data, which was instead consistent with quantitative deficiencies. Conversely, qualitative defects were misinterpreted as quantitative deficiencies at a higher error rate (14.3%), but this was more often due to laboratories misinterpreting their data (40% of errors). For test-associated errors, VWF:RCo and VWF:GPIbM were associated with the highest variability and error rate, which was many-fold higher than that using VWF:CB. Chemiluminescence ('CLIA') procedures were associated with lowest inter-laboratory variability and errors overall. These findings in part explain the high rate of errors associated with VWD diagnosis. VWF:GPIbM showed a surprisingly high rate of test associated errors, whilst CLIA procedures performed best overall.


Asunto(s)
Enfermedades de von Willebrand , Pruebas de Coagulación Sanguínea , Humanos , Laboratorios , Enfermedades de von Willebrand/diagnóstico , Factor de von Willebrand
7.
8.
Clin Chem Lab Med ; 58(8): 1322-1331, 2020 07 28.
Artículo en Inglés | MEDLINE | ID: mdl-32126010

RESUMEN

Background Investigation of hemostasis is problematic when patients are on anticoagulant therapy. Rivaroxaban especially causes substantial interference, extending many clot-based tests, thereby leading to false positive or negative events. In particular, rivaroxaban affects some assays for activated protein C resistance (APCR). Methods We assessed, in an international setting, cross laboratory (n = 31) testing using four samples to evaluate rivaroxaban induced interference in APCR testing, and whether this interference could be neutralised. The samples comprised: (A) pool of normal plasma (APCR-negative control); (B) this normal pool spiked with rivaroxaban (200 ng/mL) to create rivaroxaban-induced interference (potential 'false' positive APCR event sample); (C) the rivaroxaban sample subsequently treated with a commercial direct oral anticoagulant 'DOAC-neutraliser' (DOAC Stop), or (D) treated with andexanet alfa (200 µg/mL). Testing was performed blind to sample type. Results The rivaroxaban-spiked sample generated false positive APCR results for some, but unexpectedly not most APCR-tests. The sample treated with DOAC Stop evidenced a correction in the rivaroxaban-affected APCR assays, and did not otherwise adversely affect the rivaroxaban 'unaffected' APCR assays. The andexanet alfa-treated sample did not evidence correction of the false positive APCR, and instead unexpectedly exacerbated false positive APCR status with many tests. Conclusions DOAC Stop was able to neutralise any APCR interference induced by rivaroxaban. In contrast, andexanet alfa did not negate such interference, and instead unexpectedly created more false-positive APCR events.


Asunto(s)
Resistencia a la Proteína C Activada/diagnóstico , Inhibidores del Factor Xa/administración & dosificación , Factor Xa/farmacología , Proteínas Recombinantes/farmacología , Rivaroxabán/administración & dosificación , Resistencia a la Proteína C Activada/sangre , Inhibidores del Factor Xa/efectos adversos , Inhibidores del Factor Xa/sangre , Femenino , Humanos , Masculino , Rivaroxabán/efectos adversos , Rivaroxabán/sangre
9.
Haemophilia ; 26(2): 354-362, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31962376

RESUMEN

INTRODUCTION: Investigation of factors (F) VIII and IX is common, with testing important for diagnosis or exclusion of haemophilia A or B, associated acquired conditions and factor inhibitors. Rivaroxaban, a common direct anti-Xa agent, causes significant interference in clotting assays, including substantial false reduction of factor levels. AIM: To assess whether rivaroxaban-induced interference of FVIII and FIX testing could be neutralized. MATERIALS AND METHODS: An international, cross-laboratory exercise for FVIII (n = 84) and FIX (n = 74), using four samples: (A) pool of normal plasma; (B) pool spiked with rivaroxaban (200 ng/mL); (C) rivaroxaban sample subsequently treated with 'DOAC Stop' and; (D) rivaroxaban sample treated with andexanet alfa (200 µg/mL). Testing performed blind to sample type. RESULTS: All laboratories reported normal FIX and 94% reported normal FVIII in the pool sample. Instead, 55% and 95%, respectively, reported abnormal FIX and FVIII levels for the rivaroxaban sample. DOAC Stop treatment evidenced a correction in most laboratories (100% reported normal FIX and 86% normal FVIII). Andexanet alfa provided intermediate results, with many laboratories still reporting abnormal results (59% for FVIII, 18% for FIX). We also identified reagent-specific issues. CONCLUSIONS: As expected, rivaroxaban caused false low values of FVIII and FIX. This might lead to increased testing to identify the cause of low factor levels and potentially lead to false identification of (mild) haemophilia A or B if unrecognized by clinicians/laboratories. DOAC Stop effectively neutralized the rivaroxaban effect, but andexanet alfa less so, with reagent-related effects evident, and thus, false low values sometimes persisted.


Asunto(s)
Pruebas de Coagulación Sanguínea/métodos , Factor IX/uso terapéutico , Factor VIII/uso terapéutico , Hemostáticos/uso terapéutico , Rivaroxabán/uso terapéutico , Factor IX/farmacología , Factor VIII/farmacología , Hemostáticos/farmacología , Humanos , Rivaroxabán/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA