1.
Health Phys ; 110(1): 1-10, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26606060

RESUMEN

Exposure to spark discharges may occur beneath high voltage transmission lines when contact is initiated with a conductive object (such as a motor vehicle) with the spark discharge mediated by the ambient electric field from the line. The objective of this study was to assess whether such exposures could interfere with the normal functioning of implanted cardiac pacemakers (PMs). The experiment consisted of PMs implanted in a human-sized phantom and then exposed to spark discharge through an upper extremity. A circuit was designed that produced spark discharges between two spherical electrodes fed to the phantom's left hand. The circuit was set to deliver a single discharge per half cycle (every 10 ms) about 10 µs in duration with a peak current of 1.2-1.3 A, thus simulating conditions under a 400-kV power line operating at 50 Hz. Of 29 PMs acquired, all were tested in unipolar configuration and 20 in bipolar configuration with exposure consisting of 2 min of continuous exposure (one unit was exposed for 1 min). No interference was observed in bipolar configuration. One unit in unipolar configuration incorrectly identified ventricular extra systoles (more than 400 beats min(-1)) for 2 s. The use of unipolar configuration in new implants is extremely rare, thus further minimizing the risk of interference with the passage of time. Replication of this study and, if safety for human subjects can be assured, future testing of human subjects is also advisable.


Asunto(s)
Electricidad , Campos Electromagnéticos , Marcapaso Artificial/normas , Fantasmas de Imagen , Seguridad de Equipos , Humanos
2.
Radiat Prot Dosimetry ; 152(4): 279-95, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22619351

RESUMEN

Electric and magnetic field exposure limits published by International Commission for Non-Ionizing Radiation Protection and Institute of Electrical and Electronics Engineers are aimed at protection against adverse electrostimulation, which may occur by direct coupling to excitable tissue and, in the case of electric fields, through indirect means associated with surface charge effects (e.g. hair vibration, skin sensations), spark discharge and contact current. For direct coupling, the basic restriction (BR) specifies the not-to-be-exceeded induced electric field. The key results of anatomically based electric and magnetic field dosimetry studies and the relevant characteristics of excitable tissue were first identified. This permitted us to assess the electric and magnetic field exposure levels that induce dose in tissue equal to the basic restrictions, and the relationships of those exposure levels to the limits now in effect. We identify scenarios in which direct coupling of electric fields to peripheral nerve could be a determining factor for electric field limits.


Asunto(s)
Campos Electromagnéticos , Concentración Máxima Admisible , Modelos Anatómicos , Modelos Biológicos , Dosis de Radiación , Radiometría/métodos , Recuento Corporal Total/métodos , Algoritmos , Simulación por Computador , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Phys Med Biol ; 56(13): 4091-101, 2011 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-21693787

RESUMEN

For magnetic field exposures at extremely low frequencies, the electrostimulatory response with the lowest threshold is the magnetophosphene, a response that corresponds to an adult exposed to a 20 Hz magnetic field of nominally 8.14 mT. In the IEEE standard C95.6 (2002), the corresponding in situ field in the retinal locus of an adult-sized ellipsoidal was calculated to be 53 mV m(-1). However, the associated dose in the retina and brain at a high level of resolution in anatomically correct human models is incompletely characterized. Furthermore, the dose maxima in tissue computed with voxel human models are prone to staircasing errors, particularly for the low-frequency dosimetry. In the analyses presented in this paper, analytical and quasi-static finite-difference time-domain (FDTD) solutions were first compared for a three-layer sphere exposed to a uniform 50 Hz magnetic field. Staircasing errors in the FDTD results were observed at the tissue interface, and were greatest at the skin-air boundary. The 99th percentile value was within 3% of the analytic maximum, depending on model resolution, and thus may be considered a close approximation of the analytic maximum. For the adult anatomical model, TARO, exposed to a uniform magnetic field, the differences in the 99th percentile value of in situ electric fields for 2 mm and 1 mm voxel models were at most several per cent. For various human models exposed at the magnetophosphene threshold at three orthogonal field orientations, the in situ electric field in the brain was between 10% and 70% greater than the analytical IEEE threshold of 53 mV m(-1), and in the retina was lower by roughly 50% for two horizontal orientations (anterior-posterior and lateral), and greater by about 15% for a vertically oriented field. Considering a reduction factor or safety factors of several folds applied to electrostimulatory thresholds, the 99th percentile dose to a tissue calculated with voxel human models may be used as an estimate of the tissue's maximum dose.


Asunto(s)
Encéfalo/fisiología , Electricidad , Magnetismo , Fosfenos/fisiología , Retina/fisiología , Conductividad Eléctrica , Humanos , Modelos Anatómicos , Piel , Cráneo , Incertidumbre