1.
Cathet Cardiovasc Diagn ; 41(2): 152-6, 1997 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-9184287

RESUMEN

This study was designed to evaluate the alterations in doppler derived coronary blood flow velocities and flow reserve following rotational ablation. Changes in doppler derived coronary blood flow velocity variables have been valuable in assessing the physiological outcome following coronary balloon angioplasty. Rotational ablation's mechanism of plaque removal could alter distal vascular bed characteristics, and, as a result, intracoronary blood flow velocities and the coronary flow reserve. A 12-MHz doppler guidewire recorded intracoronary phasic velocities and coronary flow reserve (as assessed by the hyperemic response to adenosine [12-18 mcg intracoronary]) in 28 patients, before and after rotational ablation of 30 lesions. Adjunctive balloon angioplasty was performed in 27 of 28 patients (96%). Rotational ablation and adjunctive balloon angioplasty successfully reduced the lesion diameter (87 +/- 9% to 14 +/- 11%; P < 0.001). A significant increase in the mean distal average peak velocity (25 +/- 13 cm/sec, before; 47 +/- 22 cm/sec, after; P < 0.001), and decrease in the proximal to distal average peak velocity ratio, (2.1 +/- 1.3; to 1.2 +/- 0.4; P = 0.002) was recorded. The mean distal diastolic to systolic velocity ratio (before, 1.4 +/- 0.7; after, 1.6 +/- 0.8; P = 0.44) and the coronary flow reserve (before, 1.6 +/- 0.6; after, 1.5 +/- 0.5; P = 0.34) did not increase despite increases in distal velocities, following successful intervention. Doppler derived distal coronary blood flow velocities increased following rotational ablation and adjunctive balloon angioplasty, with resolution of transstenotic velocity gradient. Changes in distal phasic velocity pattern and coronary flow reserve, immediately after the intervention, were not useful in the assessment of the functional outcome and may be related to abnormalities in distal vascular bed vasoreactivity produced by rotational ablation.


Asunto(s)
Aterectomía Coronaria , Circulación Coronaria , Enfermedad Coronaria/terapia , Anciano , Velocidad del Flujo Sanguíneo , Enfermedad Coronaria/fisiopatología , Femenino , Humanos , Flujometría por Láser-Doppler , Masculino , Persona de Mediana Edad
2.
Am J Cardiol ; 75(15): 1051-5, 1995 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-7747688

RESUMEN

A Palmaz-Schatz stent was successfully placed in 92 stenotic renal arteries (76 patients) for (1) hypertension in 62 (82%), and/or (2) chronic renal failure (serum creatinine > or = 1.5 mg/dl) and preservation of renal function in 39 (51%). Patients were followed to assess clinical and angiographic 6-month outcome. Angiography, performed in 45 of 62 eligible patients (73%) and in 56 of 74 treated arteries (76%), showed restenosis occurring in 14 renal arteries (25%). Serum creatinine improved or remained stable in 78% of patients. In patients with chronic renal failure, improvement or stability was observed in 55%. Blood pressure recordings significantly decreased for the entire cohort (systolic: 168 +/- 25 to 156 +/- 22 mm Hg, p < 0.0001; diastolic: 87 +/- 11 to 81 +/- 11 mm Hg, p < 0.005), and for hypertensive patients with normal creatinine (systolic: 179 +/- 20 to 155 +/- 23 mm Hg, p < 0.0001; diastolic: 92 +/- 9 to 83 +/- 12 mm Hg, p < 0.002). These follow-up data of a prospective, nonrandomized, observational study showed that stent recanalization of atherosclerotic renal artery stenoses was beneficial with regard to renal function and blood pressure response, and had a restenosis incidence of 25%.


Asunto(s)
Arteriosclerosis/cirugía , Obstrucción de la Arteria Renal/cirugía , Stents , Anciano , Arteriosclerosis/complicaciones , Arteriosclerosis/diagnóstico por imagen , Presión Sanguínea , Estudios de Cohortes , Creatinina/sangre , Femenino , Estudios de Seguimiento , Humanos , Hipertensión Renovascular/etiología , Hipertensión Renovascular/fisiopatología , Fallo Renal Crónico/sangre , Fallo Renal Crónico/etiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Radiografía , Recurrencia , Arteria Renal/diagnóstico por imagen , Obstrucción de la Arteria Renal/complicaciones , Obstrucción de la Arteria Renal/diagnóstico por imagen , Wisconsin
3.
Cathet Cardiovasc Diagn ; 34(4): 281-5, 1995 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-7621536

RESUMEN

Primary (without antecedent balloon dilation) Palmaz stent implantation was successfully performed in 27 consecutive patients entering with 31 obstructed subclavian arteries. Stents (n = 50) were successfully deployed, using the brachial (n = 7), femoral (n = 16), or combined (n = 8) approach, to revascularize 31 subclavian vessels [8 occluded (26%); 23 stenotic (74%)], using a 6 or 7.5 French delivery system. The indications for intervention were arm claudication in 8 patients (30%), subclavian steal syndrome in 11 patients (41%), angina pectoris secondary to impaired blood flow to the left internal mammary artery coronary bypass in 6 patients (22%), and recanalization of a left subclavian occlusion to permit central arterial access and performance of a second interventional procedure 2 patients (7%). The percent diameter stenosis improved from 85 +/- 12% to 6 +/- 7% (P < 0.001); and, the peak and mean translesion gradients decreased, respectively, from 56 +/- 35 mm Hg to 3 +/- 4 mm Hg (P < 0.01), and 29 +/- 18 mm Hg to 2 +/- 2 mm Hg (P < 0.01). Procedural complications encountered were one stent dislodgement with migration into and uneventful deployment within the right external iliac artery, and two brachial artery repairs. No acute vessel closures, deaths, myocardial infarctions, cerebrovascular accidents, transient ischemic attacks, or need for transfusions occurred. Therefore, primary subclavian artery stent deployment can be performed using low-profile sheath systems with excellent success (100%), resulting in immediate restoration of pulsatile flow, and few complications. The incidence of lesion recurrence remains for follow-up studies.


Asunto(s)
Angioplastia de Balón/instrumentación , Arteriopatías Oclusivas/terapia , Stents , Arteria Subclavia , Síndrome del Robo de la Subclavia/terapia , Adulto , Anciano , Anciano de 80 o más Años , Angina de Pecho/diagnóstico por imagen , Angina de Pecho/terapia , Brazo/irrigación sanguínea , Arteriopatías Oclusivas/diagnóstico por imagen , Presión Sanguínea/fisiología , Femenino , Humanos , Claudicación Intermitente/diagnóstico por imagen , Claudicación Intermitente/terapia , Anastomosis Interna Mamario-Coronaria , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/terapia , Radiografía , Arteria Subclavia/diagnóstico por imagen , Síndrome del Robo de la Subclavia/diagnóstico por imagen
4.
Eur Heart J ; 15(11): 1456-62, 1994 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-7835359

RESUMEN

After placement of a Gianturco-Roubin metallic, coiled coronary stent(s) following balloon angioplasty (PTCA), a pre-discharge (7 day) angiogram determined the patency of the old coronary bypass vein graft(s) (SVG) (> or = 5 years remote from their last surgery, mean age: 8.5 +/- 1.8 years). Metallic, coiled stents were successfully deployed in 95/96 (99%) patients within 100/101 (99%) SVGs. The indications for deployment were threatened [81 patients (84%)] or acute [15 patients (16%)] vein graft closure following PTCA. Intragraft urokinase infusion was performed in 17 patients (17%) [6 patients with baseline occlusions; 11 with abrupt closure post PTCA]. Complications encountered included three (3%) in-hospital deaths (two procedure related) two (2%) Q wave myocardial infarctions, six (6%) non-Q wave myocardial infarctions, and 22 (22%) bleeding problems. These included, not mutually exclusively, 21 (22%) requiring transfusions, six (6%) cases of gastrointestinal bleeding, six (6%) pseudoaneurysms, five (5%) retroperitoneal haemorrhages and two (2%) cerebrovascular accidents. All patients received dipyridamole, aspirin, dextran, and anticoagulation (heparin 10-20,000 U intra-procedurally); a heparin infusion was continued for 5 +/- 1 days, despite warfarin administration which attained a therapeutic prothrombin time (PT) (1.5-2 times control) by 3 +/- 1 days. Out of the 95 successfully treated patients, six with eight stented grafts were ineligible for pre-discharge angiography. Of the six, three died in hospital (four SVGs), one had an intracerebral haemorrhage (one SVG), and two were asymptomatic patients with chronic renal failure (three SVGs).(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Puente de Arteria Coronaria , Enfermedad Coronaria/terapia , Oclusión de Injerto Vascular/prevención & control , Stents , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/etiología , Femenino , Hemorragia Gastrointestinal/etiología , Oclusión de Injerto Vascular/etiología , Hemorragia/etiología , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Vena Safena/trasplante , Stents/efectos adversos , Resultado del Tratamiento , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...