Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Chromatogr Sci ; 54(4): 598-603, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26786906

RESUMEN

A microliter dead-volume flow-through cell as a potentiometric detector is described in this article for sensitive, selective and simultaneous detection of common monovalent anions and cations in single column ion chromatography for the first time. The detection cell consisted of less selective anion- and cation-selective composite membrane electrodes together with a solid-state composite matrix reference electrode. The simultaneous separation and sensitive detection of sodium (Na(+)), potassium (K(+)), ammonium (NH4 (+)), chloride (Cl(-)) and nitrate (NO3 (-)) in a single run was achieved by using 98% 1.5 mM MgSO4 and 2% acetonitrile eluent with a mixed-bed ion-exchange separation column without suppressor column system. The separation and simultaneous detection of the anions and cations were completed in 6 min at the eluent flow-rate of 0.8 mL/min. Detection limits, at S/N = 3, were ranged from 0.2 to 1.0 µM for the anions and 0.3 to 3.0 µM for the cations, respectively. The developed method was successfully applied to the simultaneous determination of monovalent anions and cations in several environmental and biological samples.


Asunto(s)
Aniones/análisis , Cationes Monovalentes/análisis , Cromatografía por Intercambio Iónico/métodos
2.
Environ Monit Assess ; 185(3): 2115-21, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22628104

RESUMEN

In this study, an ultra-sensitive and highly selective, rapid flow-injection spectrophotometric method for the determination of iron (II) and total iron has been proposed. The method was based on the reaction between iron (II) and 2', 3, 4', 5, 7-pentahydroxyflavone in slightly acidic solution with a strong absorption at 415 nm. The carrier solution used was 1 × 10(-5) M 2', 3, 4', 5, 7-pentahydroxyflavone in 0.1 M HAc/Ac(-) buffer solution at pH 4.5. Parameters that affect simultaneously the determination of iron (II) and interfering ions were tested. The relative standard deviation for the determination of 50 µg L(-1) iron (II) was 0.85 % (n = 10), and the limit of detection (blank signal plus three times the standard deviation of the blank) was 3 µg L(-1), both based on injection volumes of 20 µL. The method has been successfully applied to the determination of iron (II) and total iron in water samples and ore samples. The method was verified by analysing a certified reference material Zn/Al/Cu 43XZ3F.


Asunto(s)
Monitoreo del Ambiente/métodos , Flavonoides/química , Hierro/análisis , Contaminantes Químicos del Agua/análisis , Análisis de Inyección de Flujo/métodos , Agua Dulce/química , Hierro/química , Espectrofotometría/métodos , Contaminantes Químicos del Agua/química
3.
Artif Cells Nanomed Biotechnol ; 41(2): 131-6, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22779924

RESUMEN

Novel creatine bienzymatic potentiometric biosensors were prepared by immobilizing urease and creatinase on all solid-state contact PVC-containing palmitic acid and carboxylated PVC matrix membrane ammonium-selective electrodes without inner reference solution. Potentiometric characteristics of biosensors were examined in physiological model solutions at different creatine concentrations. The linear working range and long-term sensitivity of the biosensors were also determined. The creatine biosensors prepared by using the carboxylated PVC membrane electrodes showed more effective performance than those of the PVC containing palmitic acid membrane electrodes. Creatine assay in serum samples was successfully carried out by using the standard addition method.


Asunto(s)
Técnicas Biosensibles/instrumentación , Creatina/sangre , Enzimas Inmovilizadas/química , Compuestos de Amonio Cuaternario/química , Ureasa/química , Ureohidrolasas/química , Electrodos , Concentración de Iones de Hidrógeno , Ácido Palmítico/química , Cloruro de Polivinilo/química , Potenciometría , Soluciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA