Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
JPGN Rep ; 5(2): 194-196, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38756124

RESUMEN

Crohn's disease has been described as the "great mimicker" with a wide array of presentations. We describe a case of a teenager who presented with tetany and undetectable vitamin D as initial presentation of Crohn's disease. There are reports of adults in tetany due to electrolyte derangements in chronic gastrointestinal diseases secondary to malabsorption. However, the role of deficient vitamin D as it contributes to immune system dysfunction has only begun to be explored. Vitamin D is essential for calcium absorption, immune regulation, and gut epithelial barrier. This case report discusses vitamin D physiology and its potential mediation in the pathogenesis of inflammatory bowel disease.

2.
Eur J Gastroenterol Hepatol ; 34(5): 478-487, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-35170533

RESUMEN

Benign biliary strictures (BBS) are usually treated with endoscopic retrograde cholangiopancreatography (ERCP) with the placement of multiple plastic stents (MPS) or a covered self-expandable metal stent (CSEMS). In this meta-analysis, we compared the efficacy and safety of MPS and CSEMS in the management of BBS. We reviewed several databases from inception to 28 April 2021 to identify RCTs that compared MPS with CSEMS in the management of BBS. Our outcomes of interest were stricture resolution, stricture recurrence, adverse events, stent migration and mean number of ERCPs to achieve stricture resolution. Data were analyzed using a random-effects model. We included eight RCTs with 524 patients. We found no significant difference in the rate of stricture resolution (risk ratio, 1.02; 95% CI, 0.96-1.10), stricture recurrence (risk ratio, 1.68; 95% CI, 0.72-3.88) or adverse events (risk ratio, 1.17; 95% CI, 0.73-1.87) between groups. Mean number of ERCPs was significantly lower in the CSEMS group (SMD, -1.99; 95% CI, -3.35 to -0.64). The rate of stent migration was significantly higher in the CSEMS group. CSEMS are comparable in efficacy and safety to MPS in the management of BBS but require fewer ERCPs to achieve stricture resolution.


Asunto(s)
Colestasis , Stents Metálicos Autoexpandibles , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Colestasis/diagnóstico por imagen , Colestasis/etiología , Colestasis/cirugía , Constricción Patológica , Humanos , Metales , Plásticos , Ensayos Clínicos Controlados Aleatorios como Asunto , Stents Metálicos Autoexpandibles/efectos adversos , Stents/efectos adversos , Resultado del Tratamiento
3.
Dig Dis Sci ; 67(8): 3518-3528, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34505257

RESUMEN

BACKGROUND AND AIMS: Studies evaluating the role of endoscopic submucosal dissection (ESD) in the management of superficial pharyngeal cancers have reported promising results. This meta-analysis evaluates the efficacy and safety of ESD in the management of superficial pharyngeal cancers. METHODS: We reviewed several databases from inception to September 03, 2020, to identify studies evaluating the efficacy and safety of ESD in the management of superficial pharyngeal cancers. Our outcomes of interest were en bloc resection rate, complete resection rate, adverse events, and rates of local recurrence. Pooled rates with 95% confidence intervals (CI) for all outcomes were calculated using random-effect model. Heterogeneity was assessed by I2 statistic. We assessed publication bias by using funnel plots and Egger's test. We conducted meta-regression analysis to explore heterogeneity in analyses. RESULTS: Ten studies were included in analyses. All studies were from Asia. Pooled rates (95% CI) for en bloc resection and complete resection were 94% (87%, 97%) and 72% (62%, 80%), respectively. The pooled rates (95% CI) for adverse events and local recurrence were 10% (5%, 17%) and 1.9% (0.9%, 4%), respectively. Most of the analyses were limited by substantial heterogeneity. On meta-regression analysis, the heterogeneity was explained by size of tumor and histology. Funnel plots and Egger's test showed no evidence of publication bias. CONCLUSIONS: This meta-analysis including studies from Asian countries demonstrated that ESD is an efficacious and safe option in the management of superficial pharyngeal cancers. More studies and studies from Western countries are needed to further validate these findings.


Asunto(s)
Resección Endoscópica de la Mucosa , Neoplasias Faríngeas , Asia , Resección Endoscópica de la Mucosa/efectos adversos , Resección Endoscópica de la Mucosa/métodos , Humanos , Recurrencia Local de Neoplasia , Neoplasias Faríngeas/etiología , Neoplasias Faríngeas/patología , Neoplasias Faríngeas/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...