Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Int J Cardiovasc Imaging ; 27(1): 113-21, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20524070

RESUMEN

The health and economic implications of new imaging technologies are increasingly relevant policy issues. Cardiac magnetic resonance imaging (CMR) is currently not or not sufficiently reimbursed in a number of countries including Germany, presumably because of a limited evidence base. It is unknown, however, whether it can be effectively used to facilitate medical decision-making and reduce costs by serving as a gatekeeper to invasive coronary angiography. We investigated whether the application of CMR in patients suspected of having coronary artery disease (CAD) reduces costs by averting referrals to cardiac catheterization. We used propensity score methods to match 218 patients from a CMR registry to a previously studied cohort in which CMR was demonstrated to reliably identify patients who were low-risk for major cardiac events. Covariates over which patients were matched included comorbidity profiles, demographics, CAD-related symptoms, and CAD risk as measured by Morise scores. We determined the proportion of patients for whom cardiac catheterization was deferred based upon CMR findings. We then calculated the economic effects of practice pattern changes using data on cardiac catheterization and CMR costs. CMR reduced the utilization of cardiac catheterization by 62.4%. Based on estimated catheterization costs of € 619, the utilization of CMR as a gatekeeper reduced per-patient costs by a mean of € 90. Savings were realized until CMR costs exceeded € 386. Cost savings were greatest for patients at low-risk for CAD, as measured by baseline Morise scores, but were present for all Morise subgroups with the exception of patients at the highest risk of CAD. CMR significantly reduces the utilization of cardiac catheterization in patients suspected of having CAD. Per-patient savings range from € 323 in patients at lowest risk of CAD to € 58 in patients at high-risk but not in the highest risk stratum. Because a negative CMR evaluation has high negative predictive value, its application as a gatekeeper to cardiac catheterization should be further explored as a treatment option.


Asunto(s)
Adenosina , Angiografía Coronaria/economía , Enfermedad de la Arteria Coronaria/diagnóstico , Costos de la Atención en Salud , Reembolso de Seguro de Salud , Imagen por Resonancia Magnética/economía , Programas Nacionales de Salud/economía , Vasodilatadores , Adenosina/economía , Anciano , Enfermedad de la Arteria Coronaria/economía , Ahorro de Costo , Análisis Costo-Beneficio , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Modelos Económicos , Valor Predictivo de las Pruebas , Derivación y Consulta/economía , Sistema de Registros , Procedimientos Innecesarios/economía , Vasodilatadores/economía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA