Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 5: 14665, 2015 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-26494523

RESUMEN

The ability to characterise crystallographic microstructure, non-destructively and in three-dimensions, is a powerful tool for understanding many aspects related to damage and deformation mechanisms in polycrystalline materials. To this end, the technique of X-ray diffraction contrast tomography (DCT) using monochromatic synchrotron and polychromatic laboratory X-ray sources has been shown to be capable of mapping crystal grains and their orientations non-destructively in 3D. Here we describe a novel laboratory-based X-ray DCT modality (LabDCT), enabling the wider accessibility of the DCT technique for routine use and in-depth studies of, for example, temporal changes in crystallographic grain structure non-destructively over time through '4D' in situ time-lapse studies. The capability of the technique is demonstrated by studying a titanium alloy (Ti-ß21S) sample. In the current implementation the smallest grains that can be reliably detected are around 40 µm. The individual grain locations and orientations are reconstructed using the LabDCT method and the results are validated against independent measurements from phase contrast tomography and electron backscatter diffraction respectively. Application of the technique promises to provide important insights related to the roles of recrystallization and grain growth on materials properties as well as supporting 3D polycrystalline modelling of materials performance.

2.
J Synchrotron Radiat ; 21(Pt 1): 66-75, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24365918

RESUMEN

Hard X-ray fluorescence microscopy is one of the most sensitive techniques for performing trace elemental analysis of biological samples such as whole cells and tissues. Conventional sample preparation methods usually involve dehydration, which removes cellular water and may consequently cause structural collapse, or invasive processes such as embedding. Radiation-induced artifacts may also become an issue, particularly as the spatial resolution increases beyond the sub-micrometer scale. To allow imaging under hydrated conditions, close to the `natural state', as well as to reduce structural radiation damage, the Bionanoprobe (BNP) has been developed, a hard X-ray fluorescence nanoprobe with cryogenic sample environment and cryo transfer capabilities, dedicated to studying trace elements in frozen-hydrated biological systems. The BNP is installed at an undulator beamline at sector 21 of the Advanced Photon Source. It provides a spatial resolution of 30 nm for two-dimensional fluorescence imaging. In this first demonstration the instrument design and motion control principles are described, the instrument performance is quantified, and the first results obtained with the BNP on frozen-hydrated whole cells are reported.


Asunto(s)
Técnicas Biosensibles , Frío , Colorantes Fluorescentes , Congelación , Microscopía Fluorescente
3.
J Synchrotron Radiat ; 19(Pt 5): 751-8, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22898954

RESUMEN

In this paper the choice between bending magnets and insertion devices as sample illuminators for a hard X-ray full-field microscope is investigated. An optimized bending-magnet beamline design is presented. Its imaging speed is very competitive with the performance of similar microscopes installed currently at insertion-device beamlines. The fact that imaging X-ray microscopes can accept a large phase space makes them very well suited to the output characteristics of bending magnets which are often a plentiful and paid-for resource. There exist opportunities at all synchrotron light sources to take advantage of this finding to build bending-magnet beamlines that are dedicated to transmission X-ray microscope facilities. It is expected that demand for such facilities will increase as three-dimensional tomography becomes routine and advanced techniques such as mosaic tomography and XANES tomography (taking three-dimensional tomograms at different energies to highlight elemental and chemical differences) become more widespread.

4.
Rev Sci Instrum ; 83(3): 033703, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22462925

RESUMEN

A dedicated in-vacuum coherent x-ray diffraction microscope was installed at the 2-ID-B beamline of the Advanced Photon Source for use with 0.7-2.9 keV x-rays. The instrument can accommodate three common implementations of diffractive imaging; plane wave illumination; defocused-probe (Fresnel diffractive imaging) and scanning (ptychography) using either a pinhole, focused or defocused probe. The microscope design includes active feedback to limit motion of the optics with respect to the sample. Upper bounds on the relative optics-to-sample displacement have been measured to be 5.8 nm(v) and 4.4 nm(h) rms/h using capacitance micrometry and 27 nm/h using x-ray point projection imaging. The stability of the measurement platform and in-vacuum operation allows for long exposure times, high signal-to-noise and large dynamic range two-dimensional intensity measurements to be acquired. Finally, we illustrate the microscope's stability with a recent experimental result.

5.
J Phys Condens Matter ; 186: 12081, 2009 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-20111669

RESUMEN

A full-field hard-x-ray microscope at SSRL has successfully imaged samples of biological and environmental origin at 40 nm resolution. Phase contrast imaging of trabeculae from a female mouse tibia, loaded in vivo to study the effects of weight-bearing on bone structure, revealed a complex network of osteocytes and canaliculi. Imaging of cordgrass roots exposed to mercury revealed nanoparticles with strong absorption contrast. 3D tomography of yeast cells grown in selenium rich media showed internal structure.

6.
J Synchrotron Radiat ; 15(Pt 4): 355-62, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18552427

RESUMEN

Scanning X-ray microprobes are unique tools for the nanoscale investigation of specimens from the life, environmental, materials and other fields of sciences. Typically they utilize absorption and fluorescence as contrast mechanisms. Phase contrast is a complementary technique that can provide strong contrast with reduced radiation dose for weakly absorbing structures in the multi-keV range. In this paper the development of a segmented charge-integrating silicon detector which provides simultaneous absorption and differential phase contrast is reported. The detector can be used together with a fluorescence detector for the simultaneous acquisition of transmission and fluorescence data. It can be used over a wide range of photon energies, photon rates and exposure times at third-generation synchrotron radiation sources, and is currently operating at two beamlines at the Advanced Photon Source. Images obtained at around 2 keV and 10 keV demonstrate the superiority of phase contrast over absorption for specimens composed of light elements.


Asunto(s)
Espectrometría por Rayos X/instrumentación , Diatomeas/ultraestructura , Microscopía de Contraste de Fase/métodos , Microesferas , Miocitos Cardíacos/ultraestructura , Poliestirenos , Proteínas/química
8.
J Synchrotron Radiat ; 7(Pt 6): 395-404, 2000 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-16609227

RESUMEN

The X1A soft X-ray undulator beamline at the NSLS has been rebuilt to serve two microscopy stations operating simultaneously. Separate spherical-grating monochromators provide the resolving power required for XANES spectroscopy at the C, N and O absorption edges. The exit slits are fixed and define the coherent source for the experiments. The optical design and the operational performance are described.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...