Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Intervalo de año de publicación
1.
Res. Biomed. Eng. (Online) ; 34(1): 31-36, Jan.-Mar. 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-896211

RESUMEN

Abstract Introduction: Panoramic radiography and cone beam computed tomography (CBCT) are very important in the diagnosis of oral diseases, however patients are exposed to the risk of ionizing radiation. This paper describes our study aimed at comparing absorbed doses in the salivary glands and thyroid due to panoramic radiography and CBCT and estimating radiation induced cancer risk associated with those methods. Methods Absorbed doses of two CBCT equipment (i-CAT® Next Generation and SCANORA® 3D) and a digital panoramic device (ORTHOPANTOMOGRAPH® OP200D) were measured using thermoluminescent dosimeters loaded in an anthropomorphic phantom on sublingual, submandibular, parotid and thyroid glands. Results Absorbed doses in the i-CAT® device ranged between 0.02 (+/-0.01) and 2.23 mGy (+/-0.03), in the SCANORA™ device ranged from 0.01 (+/-0.01) to 2.96 mGy (+/-0.29) and in the ORTHOPANTOMOGRAPH® OP200D ranged between 0.04 mGy and 0.78 mGy. The radiation induced cancer risk was highlighted in the salivary glands, which received higher doses. The protocols that offer the highest risk of cancer are the high resolution protocols of CBCT equipment. Conclusion CBCT exposes patients to higher levels of radiation than panoramic radiography, so the risks and benefits of each method should be considered. The doses in CBCT were dependent on equipment and exposure parameters, therefore adequate selection minimizes the radiation dose.

2.
Radiat Prot Dosimetry ; 175(3): 368-372, 2017 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-28013189

RESUMEN

Cone beam computed tomography (CBCT) became common in various dental specialties over the past decade. This technology is used by dental professionals regarding the investigation of maxillofacial structures. Due to the diagnostic quality and possibility of 3D view, this method has become an additional method of human exposure to ionizing radiation. This study aims to evaluate the amount of ionizing radiation absorbed by thyroid gland using CBCT. Measurements were performed by LiF dosimeters (TLD-100), positioned on a phantom for head and neck, which was irradiated by Newtom 3G-CBCT. The average of phantom surface radiation dose at the thyroid gland was 0.48 mGy. The data obtained during this study are suitable to reference values; therefore, it is important to recall that the as low as reasonably achievable principle must be applied in all procedures, thereby safeguarding the patient and also the professional.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Dosis de Radiación , Glándula Tiroides , Humanos , Fantasmas de Imagen , Dosimetría Termoluminiscente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...