Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Invest Ophthalmol Vis Sci ; 65(6): 10, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38842831

RESUMEN

Purpose: To investigate whether fractal dimension (FD)-based oculomics could be used for individual risk prediction by evaluating repeatability and robustness. Methods: We used two datasets: "Caledonia," healthy adults imaged multiple times in quick succession for research (26 subjects, 39 eyes, 377 color fundus images), and GRAPE, glaucoma patients with baseline and follow-up visits (106 subjects, 196 eyes, 392 images). Mean follow-up time was 18.3 months in GRAPE; thus it provides a pessimistic lower bound because vasculature could change. FD was computed with DART and AutoMorph. Image quality was assessed with QuickQual, but no images were initially excluded. Pearson, Spearman, and intraclass correlation (ICC) were used for population-level repeatability. For individual-level repeatability, we introduce measurement noise parameter λ, which is within-eye standard deviation (SD) of FD measurements in units of between-eyes SD. Results: In Caledonia, ICC was 0.8153 for DART and 0.5779 for AutoMorph, Pearson/Spearman correlation (first and last image) 0.7857/0.7824 for DART, and 0.3933/0.6253 for AutoMorph. In GRAPE, Pearson/Spearman correlation (first and next visit) was 0.7479/0.7474 for DART, and 0.7109/0.7208 for AutoMorph (all P < 0.0001). Median λ in Caledonia without exclusions was 3.55% for DART and 12.65% for AutoMorph and improved to up to 1.67% and 6.64% with quality-based exclusions, respectively. Quality exclusions primarily mitigated large outliers. Worst quality in an eye correlated strongly with λ (Pearson 0.5350-0.7550, depending on dataset and method, all P < 0.0001). Conclusions: Repeatability was sufficient for individual-level predictions in heterogeneous populations. DART performed better on all metrics and might be able to detect small, longitudinal changes, highlighting the potential of robust methods.


Asunto(s)
Fractales , Humanos , Femenino , Reproducibilidad de los Resultados , Masculino , Persona de Mediana Edad , Adulto , Medición de Riesgo/métodos , Anciano , Glaucoma/diagnóstico , Glaucoma/fisiopatología , Estudios de Seguimiento , Retina/diagnóstico por imagen , Vasos Retinianos/diagnóstico por imagen
2.
Comput Methods Programs Biomed ; 223: 106954, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35777216

RESUMEN

BACKGROUND AND OBJECTIVES: The detection and delineation of atherosclerotic plaque are usually manually performed by medical experts on the carotid artery. Evidence suggests that this manual process is subject to errors and has a large variability between experts, equipment, and datasets. This paper proposes a robust end-to-end framework for automatic atherosclerotic plaque detection. METHODS: The proposed framework is composed of: (1) a semantic segmentation model based on U-Net, with EfficientNet as the backbone, that obtains a segmentation mask with the carotid intima-media region; and (2) a convolutional neural network designed using Bayesian optimization that simultaneously performs a regression to get the average and maximum carotid intima media thickness, and a classification to determine the presence of plaque. RESULTS: Our approach improves the state-of-the-art in both co and bulb territories in the REGICOR database, with more than 8000 images, while providing predictions in real-time. The correlation coefficient was 0.89 in the common carotid artery and 0.74 for bulb region, and the F1 score for atherosclerotic plaque detecting was 0.60 and 0.59, respectively. The experimentation carried out includes a comparison with other fully automatic methods for carotid intima media thickness estimation found in the literature. Additionally, we present an extensive experimental study to evaluate the robustness of our proposal, as well as its suitability and efficiency compared to different versions of the framework. CONCLUSIONS: The proposed end-to-end framework significantly improves the automatic characterization of atherosclerotic plaque. The generation of the segmented mask can be helpful for practitioners since it allows them to evaluate and interpret the model's results by visual inspection. Furthermore, the proposed framework overcomes the limitations of previous research based on ad-hoc post-processing, which could lead to overestimations in the case of oblique forms of the carotid artery.


Asunto(s)
Grosor Intima-Media Carotídeo , Placa Aterosclerótica , Teorema de Bayes , Arterias Carótidas/diagnóstico por imagen , Arteria Carótida Común , Humanos , Placa Aterosclerótica/diagnóstico por imagen , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...