Int J Part Ther ; 6(4): 29-37, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32582817

RESUMEN

PURPOSE: The neutron shielding properties of the concrete structures of a proposed proton therapy facility were evaluated with help of the Monte Carlo technique. The planned facility's design omits the typical maze-structured entrances to the treatment rooms to facilitate more efficient access and, instead, proposes the use of massive concrete/steel doors. Furthermore, straight conduits in the treatment room walls were used in the design of the facility, necessitating a detailed investigation of the neutron radiation outside the rooms to determine if the design can be applied without violating existing radiation protection regulations. This study was performed to investigate whether the operation of a proton therapy unit using such a facility design will be in compliance with radiation protection requirements. METHODS: A detailed model of the planned proton therapy expansion project of the University of Texas, M. D. Anderson Cancer Center in Houston, Texas, was produced to simulate secondary neutron production from clinical proton beams using the MCNPX Monte Carlo radiation transport code. Neutron spectral fluences were collected at locations of interest and converted to ambient dose equivalents using an in-house code based on fluence to dose-conversion factors provided by the International Commission on Radiological Protection. RESULTS AND CONCLUSIONS: At all investigated locations of interest, the ambient dose equivalent values were below the occupational dose limits and the dose limits for individual members of the public. The impact of straight conduits was negligible because their location and orientation were such that no line of sight to the neutron sources (ie, the isocenter locations) was established. Finally, the treatment room doors were specially designed to provide spatial efficiency and, compared with traditional maze designs, showed that while it would be possible to achieve a lower neutron ambient dose equivalent with a maze, the increased spatial (and financial) requirements may offset this advantage.

2.
Phys Imaging Radiat Oncol ; 13: 44-49, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32551371

RESUMEN

BACKGROUND AND PURPOSE: Computed tomography (CT) scanning is the basis for radiation treatment planning, but the 50-cm standard scanning field of view (sFOV) may be too small for imaging larger patients. We evaluated the 65-cm high-definition (HD) FOV of a large-bore CT scanner for CT number accuracy, geometric distortion, image quality degradation, and dosimetric accuracy of photon treatment plans. MATERIALS AND METHODS: CT number accuracy was tested by placing two 16-cm acrylic phantoms on either side of a 40-cm phantom to simulate a large patient extending beyond the 50-cm-diameter standard scanning FOV. Dosimetric accuracy was tested using anthropomorphic pelvis and thorax phantoms, with additional acrylic body parts on either side of the phantoms. Two volumetric modulated arc therapy beams (a 15-MV and a 6-MV) were used to cover the planning target volumes. Two-dimensional dose distributions were evaluated with GAFChromic film and point dose accuracy was checked with multiple thermoluminescent dosimeter (TLD) capsules placed in the phantoms. Image quality was tested by placing an American College of Radiology accreditation phantom inside the 40-cm phantom. RESULTS: The HD FOV showed substantial changes in CT numbers, with differences of 314 HU-725 HU at different density levels. The volume of the body parts extending into the HD FOV was distorted. However, TLD-reported doses for all PTVs agreed within ± 3%. Dose agreement in organs at risk were within the passing criteria, and the gamma index pass rate was >97%. Image quality was degraded. CONCLUSIONS: The HD FOV option is adequate for RT simulation and met accreditation standards, although care should be taken during contouring because of reduced image quality.

3.
Am J Clin Oncol ; 43(3): 173-179, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31985516

RESUMEN

PURPOSE: NRG/RTOG 0848 was designed to determine whether adjuvant radiation with fluoropyrimidine sensitization improved survival following gemcitabine-based adjuvant chemotherapy for patients with resected pancreatic head adenocarcinoma. In step 1 of this protocol, patients were randomized to adjuvant gemcitabine versus the combination of gemcitabine and erlotinib. This manuscript reports the final analysis of these step 1 data. METHODS: Eligibility-within 10 weeks of curative intent pancreaticoduodenectomy with postoperative CA19-9<180. Gemcitabine arm-6 cycles of gemcitabine. Gemcitabine+erlotinib arm-gemcitabine and erlotinib 100 mg/d. Two hundred deaths provided 90% power (1-sided α=0.15) to detect the hypothesized OS signal (hazard ratio=0.72) in favor of the arm 2. RESULTS: From November 17, 2009 to February 28, 2014, 163 patients were randomized and evaluable for arm 1 and 159 for arm 2. Median age was 63 (39 to 86) years. CA19-9 ≤90 in 93%. Arm 1: 32 patients (20%) grade 4 and 2 (1%) grade 5 adverse events; arm 2, 27 (17%) grade 4 and 3 (2%) grade 5. GI adverse events, arm 1: 22% grade ≥3 and arm 2: 28%, (P=0.22). The median follow-up (surviving patients) was 42.5 months (min-max: <1 to 75). With 203 deaths, the median and 3-year OS (95% confidence interval) are 29.9 months (21.7, 33.4) and 39% (30, 45) for arm 1 and 28.1 months (20.7, 30.9) and 39% (31, 47) for arm 2 (log-rank P=0.62). Hazard ratio (95% confidence interval) comparing OS of arm 2 to arm 1 is 1.04 (0.79, 1.38). CONCLUSIONS: The addition of adjuvant erlotinib to gemcitabine did not provide a signal for increased OS in this trial.


Asunto(s)
Adenocarcinoma/tratamiento farmacológico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Quimioterapia Adyuvante/métodos , Neoplasias Pancreáticas/tratamiento farmacológico , Adenocarcinoma/mortalidad , Adulto , Anciano , Anciano de 80 o más Años , Quimioterapia Adyuvante/mortalidad , Desoxicitidina/administración & dosificación , Desoxicitidina/efectos adversos , Desoxicitidina/análogos & derivados , Clorhidrato de Erlotinib/administración & dosificación , Clorhidrato de Erlotinib/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neoplasias Pancreáticas/mortalidad , Gemcitabina , Neoplasias Pancreáticas
4.
J Appl Clin Med Phys ; 20(1): 145-153, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30580471

RESUMEN

The purpose of this study was to describe a new user-friendly, low-cost phantom that was developed to test the accuracy of rigid and deformable image registration (DIR) systems and to demonstrate the functional efficacy of the new phantom. The phantom was constructed out of acrylic and includes a variety of inserts that simulate different tissue shapes and properties. It can simulate deformations and location changes in patient anatomy by changing the rotations of both the phantom and the inserts. CT scans of this phantom were obtained and used to test the rigid and deformable registration accuracy of the Velocity software. Eight rotation and translation scenarios were used to test the rigid registration accuracy, and 11 deformation scenarios were used to test the DIR accuracy. The mean rotation accuracies in the X-Y (axial) and X-Z (coronal) planes were 0.50° and 0.13°, respectively. The mean translation accuracy was 1 mm in both the X and Y direction and was tested in soft tissue and bone. The DIR accuracies for soft tissue and bone were 0.93 (mean Dice similarity coefficient), 8.3 and 4.5 mm (mean Hausdouff distance), 0.95 and 0.79 mm (mean distance), and 1.13 and 1.12 (mean volume ratio) for soft tissue content (DTE oil) and bone, respectively. The new phantom has a simple design and can be constructed at a low cost. This phantom will allow DIR systems to be effectively and efficiently verified to ensure system performance.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos
5.
Cancers (Basel) ; 9(12)2017 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-29236051

RESUMEN

A mini-ridge filter is often used to widen the Bragg peak in the longitudinal direction at low energies but not high energies. To facilitate the clinical use of a mini-ridge filter, we performed a planning study for the feasibility of a mini-ridge filter as an integral part of the synchrotron nozzle (IMRF). Dose models with and without IMRF were commissioned in a commercial Treatment planning system (TPS). Dosimetric characteristics in a homogenous water phantom were compared between plans with and without IMRF for a fixed spread-out Bragg peak width of 4 cm with distal ranges varying from 8 to 30 g/cm². Six clinical cases were then used to compare the plan quality between plans. The delivery efficiency was also compared between plans in both the phantom and the clinical cases. The Bragg peak width was increased by 0.18 cm at the lowest energy and by only about 0.04 cm at the highest energy. The IMRF increased the spot size (σ) by up to 0.1 cm at the lowest energy and by only 0.02 cm at the highest energy. For the phantom, the IMRF negligibly affected dose at high energies but increased the lateral penumbra by up to 0.12 cm and the distal penumbra by up to 0.06 cm at low energies. For the clinical cases, the IMRF slightly increased dose to the organs at risk. However, the beam delivery time was reduced from 18.5% to 47.1% for the lung, brain, scalp, and head and neck cases, and dose uniformities of target were improved up to 2.9% for these cases owing to the reduced minimum monitor unit effect. In conclusion, integrating a mini-ridge filter into a synchrotron nozzle is feasible for improving treatment efficiency without significantly sacrificing the plan quality.

6.
Med Phys ; 44(12): 6661-6671, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28975637

RESUMEN

PURPOSE: To systematically analyze and present the properties of a small-field, double-scattering proton beam line intended to be used for the treatment of ocular cancer, and to provide configuration data for commission of the Eclipse Ocular Proton Planning System. METHODS: Measurements were made using ionization chambers, diodes, and films to determine dose profiles and output factors of the proton beams of the beam line at the Proton Therapy Center Houston. In parallel, Monte Carlo simulations were performed to validate the measured data and to provide additional insight into detailed beam parameters that are hard to measure, such as field size factors and a comparison of output factors as a function of circular and rectangular fields. RESULTS: The presented data comprise depth dose profiles, including distal and proximal profiles used to configure the Eclipse Ocular Proton Planning system, distal fall-off widths, lateral profiles and penumbrae sizes, as well as output factors as a function of field size, SOBP width, range shifter thickness, snout position, and source-to-surface distance. CONCLUSIONS: We have completed a comprehensive characterization of the beam line. The data will be useful to characterize proton beams in clinical and experimental small-field applications.


Asunto(s)
Ojo/efectos de la radiación , Terapia de Protones , Planificación de la Radioterapia Asistida por Computador/métodos , Método de Montecarlo
7.
Int J Part Ther ; 4(2): 26-34, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-31773006

RESUMEN

PURPOSE: The authors aimed to illustrate the potential dose differences to clinical target volumes (CTVs) and organs-at-risk (OARs) volumes after proton adaptive treatment planning was used. PATIENTS AND METHODS: The records of 10 patients with oropharyngeal cancer were retrospectively reviewed. Each patient's treatment plan was generated by using the Eclipse treatment planning system. Verification computed tomography (CT) scan was performed during the fourth week of treatment. Deformable image registrations were performed between the 2 CT image sets, and the CTVs and major OARs were transferred to the verification CT images to generate the adaptive plan. We compared the accumulated doses to CTVs and OARs between the original and adaptive plans, as well as between the adaptive and verification plans to simulate doses that would have been delivered if the adaptive plans were not used. RESULTS: Body contours were different on planning and week-4 verification CTs. Mean volumes of all CTVs were reduced by 4% to 8% (P ≤ .04), and the volumes of left and right parotid glands also decreased (by 11% to 12%, P ≤ .004). Brainstem and oral cavity volumes did not significantly differ (all P ≥ .14). All mean doses to the CTV were decreased for up to 7% (P ≤ .04), whereas mean doses to the right parotid and oral cavity increased from a range of 5% to 8% (P ≤ .03), respectively. CONCLUSION: Verification and adaptive planning should be recommended during the course of proton therapy for patients with head and neck cancer to ensure adequate dose deliveries to the planned CTVs, while safe doses to OARs can be respected.

8.
J Appl Clin Med Phys ; 17(5): 366-376, 2016 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-27685136

RESUMEN

This is a real case study to minimize the neutron dose equivalent (H) to a fetus using spot scanning proton beams with favorable beam energies and angles. Minimum neutron dose exposure to the fetus was achieved with iterative planning under the guidance of neutron H measurement. Two highly conformal treatment plans, each with three spot scanning beams, were planned to treat a 25-year-old pregnant female with aggressive recurrent chordoma of the base of skull who elected not to proceed with termination. Each plan was scheduled for delivery every other day for robust target coverage. Neutron H to the fetus was measured using a REM500 neutron survey meter placed at the fetus position of a patient simulating phantom. 4.1 and 44.1 µSv/fraction were measured for the two initial plans. A vertex beam with higher energy and the fetal position closer to its central axis was the cause for the plan that produced an order higher neutron H. Replacing the vertex beam with a lateral beam reduced neutron H to be comparable with the other plan. For a prescription of 70 Gy in 35 fractions, the total neutron H to the fetus was estimated to be 0.35 mSv based on final measurement in single fraction. In comparison, the passive scattering proton plan and photon plan had an estimation of 26 and 70 mSv, respectively, for this case. While radiation therapy in pregnant patients should be avoided if at all possible, our work demonstrated spot scanning beam limited the total neutron H to the fetus an order lower than the suggested 5 mSv regulation threshold. It is far superior than passive scattering beam and careful beam selection with lower energy and keeping fetus further away from beam axis are essential in minimizing the fetus neutron exposure.


Asunto(s)
Feto/efectos de la radiación , Neoplasias Inducidas por Radiación/prevención & control , Neutrones/efectos adversos , Órganos en Riesgo/efectos de la radiación , Terapia de Protones , Radioterapia Conformacional/efectos adversos , Neoplasias Craneales/radioterapia , Adulto , Femenino , Humanos , Neoplasias Inducidas por Radiación/etiología , Embarazo , Protección Radiológica , Dosificación Radioterapéutica , Dispersión de Radiación
9.
Med Phys ; 43(7): 3975, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27370116

RESUMEN

PURPOSE: To determine the patient throughput and the overall efficiency of the spot scanning system by analyzing treatment time, equipment availability, and maximum daily capacity for the current spot scanning port at Proton Therapy Center Houston and to assess the daily throughput capacity for a hypothetical spot scanning proton therapy center. METHODS: At their proton therapy center, the authors have been recording in an electronic medical record system all treatment data, including disease site, number of fields, number of fractions, delivered dose, energy, range, number of spots, and number of layers for every treatment field. The authors analyzed delivery system downtimes that had been recorded for every equipment failure and associated incidents. These data were used to evaluate the patient census, patient distribution as a function of the number of fields and total target volume, and equipment clinical availability. The duration of each treatment session from patient walk-in to patient walk-out of the spot scanning treatment room was measured for 64 patients with head and neck, central nervous system, thoracic, and genitourinary cancers. The authors retrieved data for total target volume and the numbers of layers and spots for all fields from treatment plans for a total of 271 patients (including the above 64 patients). A sensitivity analysis of daily throughput capacity was performed by varying seven parameters in a throughput capacity model. RESULTS: The mean monthly equipment clinical availability for the spot scanning port in April 2012-March 2015 was 98.5%. Approximately 1500 patients had received spot scanning proton therapy as of March 2015. The major disease sites treated in September 2012-August 2014 were the genitourinary system (34%), head and neck (30%), central nervous system (21%), and thorax (14%), with other sites accounting for the remaining 1%. Spot scanning beam delivery time increased with total target volume and accounted for approximately 30%-40% of total treatment time for the total target volumes exceeding 200 cm(3), which was the case for more than 80% of the patients in this study. When total treatment time was modeled as a function of the number of fields and total target volume, the model overestimated total treatment time by 12% on average, with a standard deviation of 32%. A sensitivity analysis of throughput capacity for a hypothetical four-room spot scanning proton therapy center identified several priority items for improvements in throughput capacity, including operation time, beam delivery time, and patient immobilization and setup time. CONCLUSIONS: The spot scanning port at our proton therapy center has operated at a high performance level and has been used to treat a large number of complex cases. Further improvements in efficiency may be feasible in the areas of facility operation, beam delivery, patient immobilization and setup, and optimization of treatment scheduling.


Asunto(s)
Modelos Teóricos , Terapia de Protones/métodos , Neoplasias del Sistema Nervioso Central/radioterapia , Registros Electrónicos de Salud , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Dosificación Radioterapéutica , Neoplasias Torácicas/radioterapia , Factores de Tiempo , Neoplasias Urogenitales/radioterapia
10.
Int J Radiat Oncol Biol Phys ; 95(1): 360-367, 2016 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-27084653

RESUMEN

PURPOSE: A single-institution prospective study was conducted to assess disease control and toxicity of proton therapy for patients with head and neck cancer. METHODS AND MATERIALS: Disease control, toxicity, functional outcomes, and patterns of failure for the initial cohort of patients with oropharyngeal squamous carcinoma (OPC) treated with intensity modulated proton therapy (IMPT) were prospectively collected in 2 registry studies at a single institution. Locoregional failures were analyzed by using deformable image registration. RESULTS: Fifty patients with OPC treated from March 3, 2011, to July 2014 formed the cohort. Eighty-four percent were male, 50% had never smoked, 98% had stage III/IV disease, 64% received concurrent therapy, and 35% received induction chemotherapy. Forty-four of 45 tumors (98%) tested for p16 were positive. All patients received IMPT (multifield optimization to n=46; single-field optimization to n=4). No Common Terminology Criteria for Adverse Events grade 4 or 5 toxicities were observed. The most common grade 3 toxicities were acute mucositis in 58% of patients and late dysphagia in 12%. Eleven patients had a gastrostomy (feeding) tube placed during therapy, but none had a feeding tube at last follow-up. At a median follow-up time of 29 months, 5 patients had disease recurrence: local in 1, local and regional in 1, regional in 2, and distant in 1. The 2-year actuarial overall and progression-free survival rates were 94.5% and 88.6%. CONCLUSIONS: The oncologic, toxicity, and functional outcomes after IMPT for OPC are encouraging and provide the basis for ongoing and future clinical studies.


Asunto(s)
Carcinoma de Células Escamosas/radioterapia , Recurrencia Local de Neoplasia , Neoplasias Orofaríngeas/radioterapia , Terapia de Protones/métodos , Radioterapia de Intensidad Modulada/métodos , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/mortalidad , Carcinoma de Células Escamosas/patología , Trastornos de Deglución/etiología , Supervivencia sin Enfermedad , Femenino , Humanos , Quimioterapia de Inducción , Masculino , Persona de Mediana Edad , Neoplasias Orofaríngeas/diagnóstico por imagen , Neoplasias Orofaríngeas/mortalidad , Neoplasias Orofaríngeas/patología , Estudios Prospectivos , Terapia de Protones/efectos adversos , Traumatismos por Radiación/patología , Radiografía , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/efectos adversos , Sistema de Registros , Estomatitis/etiología , Estomatitis/patología , Insuficiencia del Tratamiento , Resultado del Tratamiento