Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Intervalo de año de publicación
1.
BMC Musculoskelet Disord ; 22(Suppl 2): 1062, 2022 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-35039021

RESUMEN

BACKGROUND: Nowadays hip replacement is one of the most successful surgery in terms of clinical outcome and patient's satisfaction. Therefore, the choice of biomaterials in hip replacement is increasingly important with the aim of obtaining a long-term satisfaction of patient and a greater survivorship of the implants. Ceramic-on-polyethylene (COP) and ceramic-on-ceramic (CoC) bearings are two common coupling used in total hip arthroplasty. The aim of this retrospective study was to compare clinical and radiological outcomes between patients treated using CoC and CoP THA at a mean follow-up of 15 years. METHODS: 86 patients, average age 65.6, were included in the study: 43 in group A bearing CoC and 43 in group B bearing CoP. Minimum follow-up was 13 years. Primary outcome was a clinical evaluation assessed by HOOS and SF-12 questionnaires. Secondary outcome was a radiological evaluation on a A-P pelvis x-ray calculating acetabular cup inclination and anteversion and detecting osteolysis. RESULT: After a multivariate analysis was performed, our results show clinical outcomes in group B significantly better than in group A: statistically significant value (p < 0,05) was found in the mean HOOS-symptoms subscale (83.0 ± 15.4 in Group A vs 90.3 ± 12.2 in group B) in the SF-12 physical component score (39.7 ± 11.0 in Group A vs 48.1 ± 10.1 in group B) and in HOOS (79.0 ± 16 in Group A vs 87.0 ± 16 in group B). 3 squeaking was found in group A. The calculated mean acetabular cup inclination value was 44,87 in group A and 44,5 in group B and the mean socket version was 17,54 in group A and 15,10 in group B. No significant statistically relationship between radiographic parameters analyzed and clinical outcomes was noted. CONCLUSION: The current results provide us important information about the THA long-term outcome. CoP offered significantly better results compared with CoC at long-term follow up, and thus it should be considered in the choose of bearing in THA.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Cerámica , Estudios de Seguimiento , Humanos , Polietileno , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
2.
Orthop Rev (Pavia) ; 12(Suppl 1): 8674, 2020 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-32913605

RESUMEN

Differential diagnosis of destructive osteolytic spinal lesions can be a diagnostic challenge. In this study, we described a rare case of spinal metastases from primary desmoplastic melanoma which had incorrectly been diagnosed and treated as tuberculous spondylodiscitis. An 82-year-old male patient with ongoing low back pain and a history of lumbar localized Pott's performed a lumbar spine MRI that showed osteolytic lesion with first hypothesis of spondylodiscitis L2-L3. The patient was hospitalized and cause of worsening of the lumbar pain underwent a following series of non-diagnostic CT-guided and open lumbar biopsy at L2-L3 with unsuccessful antibiotic-antitubercular therapy. A new MRI revealed a worsening of previous lesions, extension of the osteolytic lesion at the level of L1-L2 and L3-L4 with neurological impairment. The diagnosis of metastatic melanoma was obtained with surgical decompression and open posterior biopsy procedure. The case described is pathognomonic of the difficulty in detecting the correct diagnosis in front of similar clinical and radiological manifestations. The presence of a previous Pott's disease in the same involved vertebral site was of crucial importance in deflecting the correct diagnostic classification of the pathology, which was possible to ascertain only following an extensive biopsy sampling in the last surgery performed.

3.
Artículo | WPRIM (Pacífico Occidental) | ID: wpr-830707

RESUMEN

The ability to directly harvest thin and superthin perforator flaps without jeopardizing their vascularity depends on knowledge of the microsurgical vascular anatomy of each perforator within the subcutaneous tissue up to the dermis. In this paper, we report our experience with ultrahigh-frequency ultrasound (UHF-US) in the preoperative planning of thin and superthin flaps. Between May 2017 and September 2018, perforators of seven patients were preoperatively evaluated by both ultrasound (using an 18-MHz linear probe) and UHF-US (using 48- and 70-MHz linear probes). Thin flaps (two cases) and superthin flaps (five cases) were elevated for the reconstruction of head and neck oncologic defects and lower limb traumatic defects. The mean flap size was 6.5×15 cm (range, 5×8 to 7.5×23 cm). No complications occurred, and all flaps survived completely. In all cases, we found 100% agreement between the preoperative UHF-US results and the intraoperative findings. The final reconstructive outcomes were considered satisfactory by both the surgeon and the patients. In conclusion, UHF-US was found to be very useful in the preoperative planning of thin and superthin free flaps, as it allows precise anticipation of very superficial microvascular anatomy. UHF-US may represent the next frontier in thin, superthin, and pure skin perforator flap design.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...