Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Clin Radiol ; 73(7): 678.e1-678.e5, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29549998

RESUMEN

AIM: To evaluate acoustic radiation force impulse (ARFI) shear-wave velocities of the bowel wall in patients with Crohn's disease (CD). MATERIAL AND METHODS: ARFI shear-wave elastography was analysed within the wall of the stomach, terminal ileum, and sigmoid, and correlated with ultrasound signs of activity in CD patients both retrospectively and in a prospective cohort. RESULTS: A total of 77 retrospective and 21 prospective CD patients were included. ARFI elastography in the stomach, the normal ileum, and sigmoid was lower than in ileitis or sigmoiditis. Retrospectively, the ARFI values correlated with the bowel wall thickness and Limberg vascularisation score. Prospectively, there was no correlation between ARFI and bowel wall thickness, Limberg score, clinical activity, or C-reactive protein. A cut-off analysis of 105 ileal ARFI measurements showed a cut-off value of 1.92 m/s for the diagnosis of ileal inflammation with 75.3% sensitivity and 87.5% specificity. CONCLUSION: In patients with CD, ARFI shear-wave velocities show a trend to higher values in inflamed bowel wall thickening on B-mode ultrasound; however, the differences appear small and may not be clinically significant. The factors influencing ARFI measurements of the bowel wall require further investigation.


Asunto(s)
Enfermedad de Crohn/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Inflamación/diagnóstico por imagen , Intestinos/diagnóstico por imagen , Adulto , Biomarcadores , Enfermedad de Crohn/complicaciones , Femenino , Humanos , Inflamación/etiología , Masculino , Estudios Prospectivos , Estudios Retrospectivos , Sensibilidad y Especificidad
2.
Ultraschall Med ; 37(6): 627-634, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27486793

RESUMEN

Purpose: To develop a contrast-enhanced ultrasound algorithm (LI-RADS-CEUS = liver imaging reporting and data system with contrast-enhanced ultrasound) for the diagnosis of hepatocellular carcinoma (HCC) in patients at risk. Materials and Methods: A CEUS algorithm (LI-RADS-CEUS) was designed analogously to CT- and MRI-based LI-RADS. LI-RADS-CEUS was evaluated retrospectively in 50 patients at risk with confirmed HCC or non-HCC lesions (test group) with subsequent validation in a prospective cohort of 50 patients (validation group). Results were compared to histology, CE-CT and CE-MRI as reference standards. Results: Tumor diagnosis in the test group/validation group (n = 50/50) were 46/41 HCCs, 3/3 intrahepatic cholangiocellular carcinomas (ICCs) and 1/6 benign lesions. The diagnostic accuracy of LI-RADS-CEUS for HCC, ICC and non-HCC-non-ICC-lesions was 89 %. For the diagnosis of HCC, the diagnostic accuracy was 93.5 % (43/46 cases) in the test group and 95.1 % (39/41 cases) in the validation group. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 94.3 %, 66.6 %, 94.3 % and 66.6 %, respectively (mean values from both cohorts). Histological findings of HCC were available in 40 versus 23 cases (in total: G1 / G2/G3: 15/35/13). Arterial hyperenhancement was seen in 68/87 (78.2 %) of HCCs. Arterial hyperenhancement with subsequent portal venous or late phase hypoenhancement was seen in 66 % of HCCs. Conclusion: LI-RADS-CEUS offers a CEUS algorithm for standardized assessment and reporting of focal liver lesions in patients at risk for HCC. Arterial hyperenhancement in CEUS is the key feature for the diagnosis of HCC in patients at risk, whereas washout is not a necessary prerequisite.


Asunto(s)
Algoritmos , Neoplasias de los Conductos Biliares/diagnóstico por imagen , Conductos Biliares Intrahepáticos/diagnóstico por imagen , Carcinoma Hepatocelular/diagnóstico por imagen , Colangiocarcinoma/diagnóstico por imagen , Medios de Contraste , Neoplasias Hepáticas/diagnóstico por imagen , Ultrasonografía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de los Conductos Biliares/clasificación , Neoplasias de los Conductos Biliares/patología , Conductos Biliares Intrahepáticos/patología , Carcinoma Hepatocelular/clasificación , Carcinoma Hepatocelular/patología , Colangiocarcinoma/clasificación , Colangiocarcinoma/patología , Estudios de Cohortes , Femenino , Adhesión a Directriz , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Neoplasias Hepáticas/clasificación , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Valores de Referencia , Estudios Retrospectivos , Factores de Riesgo , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
3.
Ultraschall Med ; 37(5): 477-481, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27112625

RESUMEN

Purpose: The aim of this study was to evaluate whether acoustic radiation force impulse (ARFI) elastography done with the 4C1 probe yields comparable results to the recently introduced 6C1HD probe. Materials and Methods: Measurements with the 4C1 and 6C1HD probes (Acuson S2000) were performed and compared in four different inclusions of an elasticity phantom model (QA049 CIRS) as well as in the liver of healthy individuals and patients with liver cirrhosis. Results: Measurements with the 6C1HD probe were slightly higher in all phantom inclusions (8, 14, 45, 80kPA) with a mean of 1.48 m/s (95 %-CI; 1.47 - 1.49), 2.18 m/s (95 %-CI; 2.17 - 2.19), 3.61 m/s (95 %-CI; 3.57 - 3.64) and 4.34 m/s (95 %-CI; 4.29 - 4.39) compared to the 4C1 transducer with 1.46 m/s (95 %-CI; 1.45 - 1.47), 2.15 m/s (95 %-CI; 2.14 - 2.16), 3.39 m/s (95 %-CI; 3.37 - 3.41) and 3.98 m/s (95 %-CI; 3.75 - 4.21), respectively (p = 0.04, p < 0.01, p < 0.01, p < 0.01). Cirrhotic patients (n = 40) had a higher mean shear wave speed with 3.00 m/s (95 %-CI; 2.80 - 3.21) with the 6C1HD transducer compared to 2.81 m/s (95 %-CI; 2.64 - 2.99) with the 4C1 transducer (p = 0.03). Healthy individuals (n = 20) had a mean shear wave speed of 1.12 m/s (95 %-CI; 1.06 - 1.17) with the 6C1HD probe and 1.12 m/s (95 %-CI; 1.05 - 1.19) with the 4C1 probe (p = 0.96). Conclusion: ARFI values assessed with a 6C1HD transducer are slightly higher than measurements with a 4C1 transducer in an ARFI phantom and in patients with liver cirrhosis. As the difference is small, current cut-off values keep their usefulness but should be interpreted with caution if measurements are close to the cut-off.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/instrumentación , Fantasmas de Imagen , Transductores , Adulto , Anciano , Diseño de Equipo , Femenino , Humanos , Hígado/diagnóstico por imagen , Cirrosis Hepática/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Valores de Referencia , Sensibilidad y Especificidad , Resistencia al Corte
4.
Radiologe ; 55(11): 949-55, 2015 Nov.
Artículo en Alemán | MEDLINE | ID: mdl-26438090

RESUMEN

Noninvasive, ultrasound-based methods for visualizing and measuring tissue elasticity are becoming more and more common in routine practice. Using hepatic shear wave elastography, cut-off levels can help to detect the degree of relevant fibrosis (F ≥ 2) with a diagnostic accuracy using the area under the reader operating characteristic (AUROC) of 87 % and cirrhosis (F = 4, AUROC 93 %). Normal values virtually exclude liver cirrhosis (negative predictive value up to 97 %) and high shear wave velocities predict complications in the course of primary sclerosing cholangitis, liver cirrhosis and chronic hepatitis B or C. Elastography is of no relevant help in the differentiation of the dignity of hepatic lesions. Concerning thyroid or breast lesions, low shear wave velocities are indicative of benign lesions and in contrast, high velocities of malignant lesions. A differentiation between benign and malignant thyroid nodules is performed by elastography with a sensitivity of 89 % and a specificity of 82 %. In breast lesions a differentiation of nodes can be improved with elastography compared to B-mode ultrasound alone with a sensitivity of 97 % and a specificity of 83 %. Invasive biopsy punctures can therefore be specifically performed or can be omitted. Due to several influencing factors, in particular during liver elastography, the measurements need to be interpreted in the clinical context. In summary, ultrasound-based elastography provides helpful information for the detection of hepatic fibrosis and for further characterization of thyroid or breast lesions in addition to classical techniques, such as B-mode imaging and color Doppler.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Interpretación de Imagen Asistida por Computador/métodos , Hepatopatías/diagnóstico por imagen , Hepatopatías/fisiopatología , Hígado/diagnóstico por imagen , Hígado/fisiopatología , Módulo de Elasticidad , Humanos , Aumento de la Imagen/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resistencia al Corte , Estrés Mecánico
5.
Z Gastroenterol ; 53(10): 1175-81, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26480053

RESUMEN

In the work-up of focal pancreatic lesions autoimmune pancreatitis (AIP) is a rare differential diagnosis to pancreatic cancer (PC) with similar clinical constellations. The aim of our study was to compare differences between proven AIP and PC using transabdominal dynamic contrast enhanced ultrasound (DCE-US). Therefore we recorded 3-minute-clips of CEUS examinations and analyzed perfusion parameters with VueBox®-quantification software. To obtain DCE-US Parameters, Regions-of-Interest were selected within the lesions and the surrounding pancreas parenchyma, serving as reference tissue. We compared 3 patients with AIP (mean age: 58 years; lesion mean size: 40 mm) to 17 patients with PC (mean age: 68 years; lesion mean size: 35.9 mm). Significant differences between PC and parenchyma could be found in the following parameters: Peak-Enhancement (PE), Wash-in-and-Wash-out-AUC, Wash-in Perfusion-Index. PE of AIP was comparable to normal parenchyma. The relation of PE between parenchyma and lesion (ΔPE) AIP and PC was significantly different [AIP: 0.21 (±0.06); PC: 0.81 (±0.1); p<0.01]. PE of neoplastic lesions was significantly lower as AIP and normal parenchyma (p<0.01). Therefore perfusion analysis in DCE-US can help to differentiate hypovascular PC from AIP presenting nearly isovascular time intensity curves. Diagnostic accuracy of DCE-US in this setting has to be validated in future prospective studies in comparison to CT and MRI.


Asunto(s)
Enfermedades Autoinmunes/diagnóstico por imagen , Aumento de la Imagen/métodos , Neoplasias Pancreáticas/diagnóstico por imagen , Pancreatitis/diagnóstico por imagen , Imagen de Perfusión/métodos , Ultrasonografía/métodos , Anciano , Medios de Contraste , Diagnóstico Diferencial , Estudios de Factibilidad , Femenino , Humanos , Masculino , Fosfolípidos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Hexafluoruro de Azufre
6.
Ultraschall Med ; 35(6): 522-7, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25202903

RESUMEN

PURPOSE: In a prospective study, we compared the different perfusion kinetics of HCC and ICC using dynamic contrast-enhanced ultrasound (DCE-US). MATERIALS AND METHODS: Patients with proven HCC and ICC were included. Three-minute video clips of CEUS examinations (CPS - low MI mode) after a bolus injection of 1.2 ml SonoVue were recorded and analyzed with quantification software (VueBox). Parameters for the arterial contrast enhancement [rise time (RT), time-to-peak (TTP)] towards portal venous contrast enhancement [mean transit time (local) (mTTl) and fall time (FT)] were quantified. Furthermore, contrast wash-out after peak enhancement (PE) (40 s, 80 s, 100 s and 120 s after PE) was compared between HCC and ICC. RESULTS: 43 patients with proven HCC (n = 23 HCC; cirrhosis n = 16) and ICC (n = 20 ICC; Cirrhosis n = 6) were examined. No statistical difference of the arterial DCEUS parameters was found between HCC and ICC. Contrast enhancement of the portal venous and late phases showed significantly lower values in the ICC group indicating early wash-out of the contrast agent: mTTl (p = 0.0209): HCC 118.4 s (SD±â€Š88.4); ICC 64.8 s (SD±â€Š49.7). FT (p = 0.0433): HCC 42.5 s (SD±â€Š27.7); ICC 27.7 s (SD±â€Š16.2). The percental loss of intensity at a definite time point after PE was significantly higher in ICC than in HCC lesions. CONCLUSION: DCE-US is able to detect and quantify differences in perfusion kinetics between HCC and ICC. Whereas arterial contrast enhancement patterns may overlap between HCC and ICC, a timed characterization of wash-out kinetics may offer an additional tool to characterize HCC and ICC. The presence of a rapid loss of signal intensity in the early portal venous phase is significantly higher in ICC than in HCC lesions.


Asunto(s)
Neoplasias de los Conductos Biliares/irrigación sanguínea , Neoplasias de los Conductos Biliares/diagnóstico por imagen , Conductos Biliares Intrahepáticos/irrigación sanguínea , Conductos Biliares Intrahepáticos/diagnóstico por imagen , Carcinoma Hepatocelular/diagnóstico por imagen , Colangiocarcinoma/irrigación sanguínea , Colangiocarcinoma/diagnóstico por imagen , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias Hepáticas/irrigación sanguínea , Neoplasias Hepáticas/diagnóstico por imagen , Fosfolípidos , Hexafluoruro de Azufre , Grabación en Video/métodos , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de los Conductos Biliares/patología , Conductos Biliares Intrahepáticos/patología , Carcinoma Hepatocelular/irrigación sanguínea , Carcinoma Hepatocelular/patología , Colangiocarcinoma/patología , Femenino , Humanos , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Estudios Prospectivos , Programas Informáticos , Ultrasonografía
7.
Ultraschall Med ; 35(1): 44-50, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24510459

RESUMEN

PURPOSE: To evaluate the diagnostic value of acoustic radiation force impulse (ARFI) and high-frequency ultrasound of the liver surface, using histology as a gold standard for the diagnosis of compensated liver cirrhosis. MATERIALS AND METHODS: 73 patients without ascites undergoing liver biopsy were included in the study. The left and right liver lobes were examined with ARFI and high-frequency ultrasound. Liver surface irregularity was quantified using image analysis software to calculate the difference between the real surface and the approximated physiological surface through a 20 mm standardized line. RESULTS: There is a significant difference between cirrhotic and non-cirrhotic patients for both quantified liver surface (QLS) and ARFI (p < 0.001). The mean values for QLS of the left lobe were 0.71 ± 0.24 mm and 1.17 ±â€Š0.80 mm, of the right lobe 0.56 ±â€Š0.26 mm and 0.87 ±â€Š0.26 mm for non-cirrhotic and cirrhotic patients, respectively. The mean values of ARFI measurements of the left lobe were 2.04 ±â€Š0.76 m/s and 2.85 ±â€Š0.81 m/s, of the right lobe 1.65 ±â€Š0.61 m/s and 3.02 ±â€Š0.77 m/s for non-cirrhotic and cirrhotic patients, respectively. Diagnostic accuracy (AUROC) was 0.78/0.80 for QLS and 0.77/0.91 for ARFI of the left/right lobe, respectively. ARFI of the right lobe is significantly better than ARFI of the left (p = 0.023) or QLS of the left (p = 0.025)/right (p = 0.046) lobe of the liver. CONCLUSION: Assessment of liver surface irregularity by high-frequency ultrasound (QLS) is a useful diagnostic test for the assessment of compensated liver cirrhosis. ARFI of the right liver lobe is significantly better than high-frequency ultrasound (QLS of the left/right lobe of the liver) and ARFI of the left lobe of the liver.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Cirrosis Hepática/diagnóstico por imagen , Hígado/diagnóstico por imagen , Adulto , Anciano , Biopsia , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Hígado/patología , Cirrosis Hepática/patología , Pruebas de Función Hepática , Masculino , Persona de Mediana Edad , Valores de Referencia , Sensibilidad y Especificidad , Programas Informáticos
8.
Clin Radiol ; 69(3): 275-9, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24309197

RESUMEN

AIM: To evaluate the association between liver stiffness measured by acoustic radiation force impulse (ARFI) elastometry and the outcome of antiviral treatment in patients with chronic viral hepatitis B and C. MATERIALS AND METHODS: Thirty-eight patients with chronic viral hepatitis B (n = 16) or hepatitis C (n = 22) underwent liver biopsy and ARFI elastometry of the right hepatic lobe. A follow-up assessment using ARFI was performed a mean of 2.3 years after the baseline evaluation. The patients with favourable outcome were classified in group S and those receiving no treatment, showing no response to treatment, or experiencing a relapse were classified in group N. RESULTS: The 38 patients had an initial mean ARFI value of 1.56 ± 0.62 m/s as compared with 1.54 ± 0.64 m/s in the follow-up evaluation. Group S showed a significant decline in ARFI values (1.55 ± 0.60 m/s versus 1.34 ± 0.47 m/s; p < 0.05) and included 16 (64%) patients with lower shear wave velocities at follow-up. In group N, liver stiffness values showed a slight but not significant increase (1.57 ± 0.70 m/s versus 1.93 ± 0.77 m/s). CONCLUSION: Changes in liver stiffness during antiviral therapy can be assessed by ARFI reflecting response or no response. ARFI elastometry is an additional, useful tool for the follow-up assessment of treatment outcome in patients with chronic viral hepatitis B or C infection.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Hepatitis B Crónica/patología , Hepatitis C Crónica/patología , Adulto , Anciano , Antivirales/uso terapéutico , Biopsia , Femenino , Hepatitis B Crónica/diagnóstico por imagen , Hepatitis B Crónica/tratamiento farmacológico , Hepatitis C Crónica/diagnóstico por imagen , Hepatitis C Crónica/tratamiento farmacológico , Humanos , Masculino , Persona de Mediana Edad
9.
Ultraschall Med ; 34(1): 38-46, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23258770

RESUMEN

PURPOSE: In order to detect an early response to anti-angiogenic therapy, this study aims at analyzing specific effects of a sorafenib-based regime on intra-tumoral D-CEUS flow parameters of patients with HCC. MATERIALS AND METHODS: Videos of the arterial phase were captured before initiation of a therapy with sorafenib and 1 and 3 months after (n = 9). Patients receiving a non-anti-angiogenic therapy (TACE, n = 10) served as a comparison group. Cross-sectional imaging was performed at the same time points and patients were followed up for 1 year. RESULTS: In the responder group (RE), the absolute (percentage) TTP was 11.28 s ± 2.03 s (1.00) before treatment, 13.60 s ± 1.52 s (1.53 ± 0.08) after one month (p = 0.0405), and 16.17 s ± 2.35 s (1.46 ± 0.07) after three months of treatment (p = 0.0071). The TTP increased significantly in the RE group as early as 1 month after initiation of sorafenib compared to the non-responder group. There were no significant differences in the non-responder group or between the NR and the TACE group at any time point. D-CEUS values from all sorafenib-treated patients showed good accordance with RECICL (response evaluation criteria in cancer of the liver) criteria (R2 = 0.7154, p = 0.0001). CONCLUSIONS: Quantitative CEUS reveals variations of dynamic parameters of blood flow during anti-tumoral therapy in liver cancer patients. Further investigations and clinical trails have to confirm that the TTP is a promising parameter in the prediction of early response to sorafenib-based therapy.


Asunto(s)
Inhibidores de la Angiogénesis/uso terapéutico , Antineoplásicos/uso terapéutico , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/tratamiento farmacológico , Medios de Contraste/administración & dosificación , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/tratamiento farmacológico , Niacinamida/análogos & derivados , Compuestos de Fenilurea/uso terapéutico , Adulto , Inhibidores de la Angiogénesis/efectos adversos , Carcinoma Hepatocelular/irrigación sanguínea , Carcinoma Hepatocelular/patología , Quimioembolización Terapéutica , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Neoplasias Hepáticas/irrigación sanguínea , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Niacinamida/uso terapéutico , Valor Predictivo de las Pruebas , Pronóstico , Flujo Sanguíneo Regional/efectos de los fármacos , Sorafenib , Resultado del Tratamiento , Ultrasonografía
10.
Ultraschall Med ; 33(6): 587-92, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23154871

RESUMEN

PURPOSE: To check the feasibility of the easy quantification of tumor vascularization derived from dynamic contrast-enhanced ultrasound (DCE-US) in comparison to dynamic contrast-enhanced computed tomography (DCE-CT) in patients with hepatocellular carcinoma (HCC). MATERIALS AND METHODS: 19 patients with cirrhosis and histologically proven HCC prospectively underwent CEUS (SonoVue) and CT (Imeron400). Following CEUS, the software ImageJ was used for the easy quantification of the echogenicity in HCC lesions and tumor-free liver parenchyma. For DCE-CT we used the software Hepacare and created arterial enhancement fraction color maps of the whole liver and HCC lesions. RESULTS: Unifocal/multifocal HCCs were detected in 12/7 (US) and 10/9 patients (CT) and biopsied nodules were defined as a reference lesion with a median of 40 mm (US) and 42 mm (CT). CEUS showed HCC-typical hyper-/hypoenhancement in the arterial/late phase in 16/19 reference lesions, while all reference lesions showed an HCC-typical vascular pattern in CT. With DCE-US, quantitative assessment could not be performed in 3/19 patients due to respiratory motion or insufficient image quality. 13/16 reference lesions showed an HCC-typical vascular pattern. Quantitative assessment was possible with DCE-CT in all patients and all reference nodules showed HCC-typical values of the arterial enhancement fraction. There was no statistical difference between CEUS, DCE-US and DCE-CT in the quantitative assessment of contrast enhancement. CONCLUSION: The quantitative evaluation of DCE-US was feasible in HCC without a statistical difference with respect to DCE-CT. Further studies with a larger study population including small nodules ≤ 2 cm are needed to assess whether this technique is helpful in routine ultrasound.


Asunto(s)
Carcinoma Hepatocelular/irrigación sanguínea , Carcinoma Hepatocelular/diagnóstico , Medios de Contraste/administración & dosificación , Interpretación de Imagen Asistida por Computador/métodos , Complejo Hierro-Dextran , Neoplasias Hepáticas/irrigación sanguínea , Neoplasias Hepáticas/diagnóstico , Neovascularización Patológica/diagnóstico , Fosfolípidos , Hexafluoruro de Azufre , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía/métodos , Anciano , Biopsia con Aguja , Competencia Clínica , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Sensibilidad y Especificidad , Evaluación de la Tecnología Biomédica , Ultrasonografía Intervencional
11.
Ultraschall Med ; 33(4): 380-5, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22723037

RESUMEN

PURPOSE: Since acoustic radiation force impulse (ARFI) elastometry is an increasingly popular method for the assessment of hepatic fibrosis and cirrhosis, we investigated factors possibly influencing hepatic elastometric measurements. MATERIALS AND METHODS: 30 healthy volunteers (17 females, 13 males) were recruited. The shear wave velocity of the right liver lobe was determined in a fasting upright and supine position and after different breathing maneuvers with the convex array (4C1) and in a supine position with the linear (9L4) ultrasound transducer. In 18 volunteers, subsequent measurements were obtained in a fasting state and 30, 60, 90 and 120 min after ingestion of a standardized breakfast. A group of 8 patients (average age: 76 years) with right heart insufficiency was also evaluated. RESULTS: In the fasting state, the ARFI shear wave velocities measured in an upright position were significantly higher than those in supine position (p< 0.0001). The supine ARFI values were significantly higher with the linear transducer than with the convex transducer (p = 0.0034). The results in deep inspiration, deep expiration and during Valsalva maneuver showed no differences. The food intake-related ARFI elastometric measurements were significantly elevated at time points 30 min (p = 0.019) and 60 min (p = 0.036) postprandial. In right heart insufficiency, the ARFI values were elevated. CONCLUSION: Hepatic ARFI elastometry is a well evaluated method. A standardized examination should include measuring in a supine position with the convex transducer (4C1) without specific breathing maneuvers. Since ARFI elastometry values increase after food intake, measurements should be performed in the fasting state, or not earlier than 2 hours postprandially. Heart dysfunction may impair ARFI accuracy.


Asunto(s)
Ingestión de Alimentos , Diagnóstico por Imagen de Elasticidad/instrumentación , Procesamiento de Imagen Asistido por Computador , Cirrosis Hepática/diagnóstico por imagen , Hígado/diagnóstico por imagen , Posicionamiento del Paciente , Respiración , Transductores , Adulto , Comorbilidad , Interpretación Estadística de Datos , Ayuno , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Sensibilidad y Especificidad , Maniobra de Valsalva , Adulto Joven
12.
Ultraschall Med ; 33(2): 164-9, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22179798

RESUMEN

PURPOSE: Evaluation of mesenteric transit time (MTT) - measured by contrast-enhanced ultrasound - as a marker for inflammatory activity in Crohn's disease. MATERIALS AND METHODS: The time of maximum enhancement of the contrast agent in the superior mesenteric artery and vein was determined visually and by software analysis. The MTT was calculated as the difference between these two time points. Findings were correlated with the Harvey-Bradshaw Index (HBI) using the Pearson correlation coefficient (r). In addition, a healthy control group was evaluated both in the fasting state and 1, 2, 3 and 4 hours postprandially. RESULTS: In 20 healthy controls the mean visual MTT during fasting was 9.76 ± 2.83 sec and decreased to a minimum 1 hour after the meal (6.6 ± 2.27 sec). 45 patients with Crohn's disease (9 males, 36 females, mean age 35 years) had a mean HBI of 5.9 ± 4.7 points. The mean software-based MTT of 9.76 ± 3.7 sec was significantly higher (p = 0.034) than the mean visual MTT of 8.22 ± 3.05 sec. The two figures correlated well (r = 0.72, p < 0.001). The HBI correlated neither with the visual (r = 0.14, p = 0.371) nor with the software-based (r = 0.16, p = 0.293) MTT. CONCLUSION: The MTT decreases in the first two hours after eating. The visually assessed and the software-based MTT correlate well, however MTT does not correlate with disease activity in patients with Crohn's disease.


Asunto(s)
Medios de Contraste/administración & dosificación , Medios de Contraste/farmacocinética , Enfermedad de Crohn/diagnóstico por imagen , Tránsito Gastrointestinal/fisiología , Interpretación de Imagen Asistida por Computador , Arteria Mesentérica Superior/diagnóstico por imagen , Venas Mesentéricas/diagnóstico por imagen , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Periodo Posprandial , Valores de Referencia , Programas Informáticos , Estadística como Asunto , Ultrasonografía , Adulto Joven
13.
Eur J Radiol ; 80(3): e226-30, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20971591

RESUMEN

PURPOSE: Acoustic Radiation Force Impulse (ARFI) is a new method for the quantification of tissue elasticity. To date, ARFI technology has not been applied systematically to establish an abdominal and thyroid status. The aim of this prospective feasibility study was to evaluate ARFI elastometry performed on various healthy abdominal organs and the thyroid gland. MATERIAL AND METHODS: 94 patients (43 females, 51 males) with a mean age of 54 years and 20 healthy controls were enrolled in the study. A routine ultrasound examination of the abdomen was scheduled in 72, and of the thyroid in 25. ARFI elastometry was performed in liver, spleen, pancreas, prostate, kidneys and thyroid gland with the ultrasound system Acuson S2000. ARFI values are proportional to tissue elasticity. Patients with ultrasonic or anamnestic evidence of diseased organs were excluded from the analysis. ARFI measurements were compared with the aid of the t-test and correlated using Spearman's correlation coefficient. RESULTS: ARFI elastometry proved feasible and the measurements obtained in the various organs differed significantly. Among healthy organs the spleen showed the highest mean ARFI velocities, followed by the kidney, thyroid, pancreas and the prostate. The lowest ARFI values were regularly found in healthy liver. Measurements in the kidneys and the spleen showed high standard deviation. CONCLUSIONS: ARFI elastometry may describe parenchymal stiffness of various abdominal organs and the thyroid gland. Further investigations are needed to compare these baseline findings in healthy organs with those of various tumours or diseases affecting the individual organs.


Asunto(s)
Abdomen/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Enfermedades de la Tiroides/diagnóstico por imagen , Glándula Tiroides/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Vísceras
14.
Ultraschall Med ; 31(4): 405-9, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20652853

RESUMEN

PURPOSE: The technology of acoustic radiation force impulse (ARFI) represents an innovative method for the quantification of tissue elasticity. The aim of this prospective pilot study was to evaluate the role of ARFI elastometry of focal liver lesions (FLL) and the surrounding liver parenchyma. MATERIALS AND METHODS: All patients with unclear FLL in B-mode ultrasound were assigned to ARFI elastometry (m/sec). Measurement sites were located within the FLL, in the peritumoral tissue and in hepatic segment VIII (intercostal approach). Histology and CEUS served as the reference for the characterization of the lesions. RESULTS: A total of 81 patients were enrolled, of whom 62 patients (39 females, 23 males; mean age 54 years) had FLL measurable by means of ARFI. The lesions were: 38 benign (61 %) and 24 malignant FLL (39 %). The ARFI elastometric values of the FLL differed significantly from those of the liver parenchyma (p < 0.001). Elastometry of benign lesions and of malignant tumors showed statistically comparable results (p = 0.28). The lowest ARFI values were observed in focal fatty sparing and the highest in CCC. Only focal fatty sparing and HCC showed negative differences between FLL and peritumoral tissue or liver parenchyma. In 23 % of the hepatic lesions, no reliable quantitative ARFI results were obtainable due to false, inconsistent or technically failed measurements. CONCLUSION: FLL vary in ARFI elastometry. However, high ARFI values occur in benign as well as in malignant lesions and do not permit differentiation between them.


Asunto(s)
Neoplasias de los Conductos Biliares/diagnóstico por imagen , Conductos Biliares Intrahepáticos/diagnóstico por imagen , Colangiocarcinoma/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Hematoma/diagnóstico por imagen , Hepatopatías/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Neoplasias de los Conductos Biliares/patología , Conductos Biliares Intrahepáticos/patología , Biopsia , Colangiocarcinoma/patología , Medios de Contraste/administración & dosificación , Diagnóstico Diferencial , Femenino , Hiperplasia Nodular Focal/diagnóstico por imagen , Hiperplasia Nodular Focal/patología , Hemangioma/diagnóstico por imagen , Hemangioma/patología , Hematoma/patología , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/patología , Hepatopatías/patología , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Fosfolípidos , Proyectos Piloto , Estudios Prospectivos , Sensibilidad y Especificidad , Hexafluoruro de Azufre
15.
Ultraschall Med ; 31(2): 151-5, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20306380

RESUMEN

PURPOSE: The acoustic radiation force impulse (ARFI) technology is a novel ultrasound method that provides information about the local elasticity of tissue in real-time. ARFI is integrated in a conventional ultrasound system. The aim of this exploratory study was to evaluate this new technique in the assessment of liver fibrosis in a cohort with chronic viral hepatitis B and C and to ascertain the most reliable hepatic segment for measurements. MATERIALS AND METHODS: 57 patients (27 female, 30 male, mean age 54 years) with chronic viral hepatitis B and C underwent ARFI imaging and consecutively liver biopsy. The results were compared to the histological fibrosis degree (F), which served as the reference. 20 healthy volunteers received ARFI quantification of different segments of the liver. RESULTS: The best ARFI assessments with the lowest rate of invalid measurements were carried out by an intercostal approach to segment VII/VIII of the liver. The ARFI velocities of the healthy group had a mean of 1.09 m/s (range 0.79 - 1.32 m/s), the means of the patient group ranged from 0.83 to 4.19 m/s. ARFI quantification correlated significantly with the histological fibrosis stage (p < 0.001). The area under the receiver operating characteristic (ROC) curves for the accuracy of ARFI imaging was 85 %, 92 % and 87 % for the diagnosis of moderate fibrosis (>or= F2), severe fibrosis (>or= F3) and cirrhosis ( = F 4), respectively. CONCLUSION: This study underscores the usefulness of ARFI as a quick method for assessing liver fibrosis or cirrhosis in patients with HBV or HCV. ARFI measurements of the liver should be performed via an intercostal access. Increasing ARFI velocities correlate with higher degree of hepatic fibrosis.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hepatitis B Crónica/diagnóstico por imagen , Hepatitis C Crónica/diagnóstico por imagen , Cirrosis Hepática/diagnóstico por imagen , Biopsia , Estudios de Cohortes , Femenino , Hepatitis B Crónica/patología , Hepatitis B Crónica/fisiopatología , Hepatitis C Crónica/patología , Hepatitis C Crónica/fisiopatología , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Hígado/fisiopatología , Cirrosis Hepática/patología , Cirrosis Hepática/fisiopatología , Pruebas de Función Hepática , Masculino , Persona de Mediana Edad , Pronóstico , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...