Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Phys Rev E ; 106(4-2): 045206, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36397480

RESUMEN

The Zeeman effect is used for measurement of magnetic fields in astrophysical and laboratory plasmas. Magnetic fields in atmospheres of magnetic white dwarf stars are in the range 40 kG-1 GG. The quadratic Zeeman effect results in the additional split and shift of lines for magnetic fields >2 MG. Hydrogen Balmer lines were studied in magnetic fields delivered by a 1 MA pulse power generator. The magnetic field was generated by rod loads 0.8-1 mm in diameter. A droplet of CH oil on the load center was the source of hydrogen. A low ionized oil layer was backlit by blackbody emission from the rod with a temperature of 0.5-0.6 eV. Zeeman splitting of H-alpha and H-beta absorption lines were with a grating spectrometer. A spectral shift of the central component of the triplet indicated the quadratic Zeeman effect in hydrogen lines.

2.
Plant Biol (Stuttg) ; 24(1): 3-8, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34569131

RESUMEN

A plant's associated biota plays an integral role in its metabolism, nutrient uptake, stress tolerance, pathogen resistance and other physiological processes. Although a virome is an integral part of the phytobiome, a major contradiction exists between the holobiont approach and the practical need to eradicate pathogens from agricultural crops. In this review, we discuss grapevine virus control, but the issue is also relevant for numerous other crops, including potato, cassava, citrus, cacao and other species. Grapevine diseases, especially viral infections, cause main crop losses. Methods have been developed to eliminate viruses and other microorganisms from plant material, but elimination of viruses from plant material does not guarantee protection from future reinfection. Elimination of viral particles in plant material could create genetic drift, leading in turn to an increase in the occurrence of pathogenic strains of viruses. A possible solution may be a combination of virus elimination and plant propagation in tissue culture with in vitro vaccination. In this context, possible strategies to control viral infections include application of plant resistance inducers, cross protection and vaccination using siRNA, dsRNA and viral replicons during plant 'cleaning' and in vitro propagation. The experience and knowledge accumulated in human immunization can help plant scientists to develop and employ new methods of protection, leading to more sustainable and healthier crop production.


Asunto(s)
Virus de Plantas , Biotecnología , Productos Agrícolas , Enfermedades de las Plantas , Vacunación
3.
Phys Rev E ; 101(5-1): 051201, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32575250

RESUMEN

We discuss the experimental and modeling results for the x-ray heating and temperature of laboratory photoionized plasmas. A method is used to extract the electron temperature based on the analysis of transmission spectroscopy data that is independent of atomic kinetics modeling. The results emphasized the critical role of x-ray heating and radiation cooling in determining the energy balance of the plasma. They also demonstrated the dramatic impact of photoexcitation on excited-state populations, line emissivity, and radiation cooling. Modeling calculations performed with astrophysical codes significantly overestimated the measured temperature.

4.
Phys Rev Lett ; 122(23): 235001, 2019 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-31298873

RESUMEN

The first systematic study of opacity dependence on atomic number at stellar interior temperatures is used to evaluate discrepancies between measured and modeled iron opacity [J. E. Bailey et al., Nature (London) 517, 56 (2015)NATUAS0028-083610.1038/nature14048]. High-temperature (>180 eV) chromium and nickel opacities are measured with ±6%-10% uncertainty, using the same methods employed in the previous iron experiments. The 10%-20% experiment reproducibility demonstrates experiment reliability. The overall model-data disagreements are smaller than for iron. However, the systematic study reveals shortcomings in models for density effects, excited states, and open L-shell configurations. The 30%-45% underestimate in the modeled quasicontinuum opacity at short wavelengths was observed only from iron and only at temperature above 180 eV. Thus, either opacity theories are missing physics that has nonmonotonic dependence on the number of bound electrons or there is an experimental flaw unique to the iron measurement at temperatures above 180 eV.

5.
Phys Rev E ; 95(6-1): 063204, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28709197

RESUMEN

Picosecond time-resolved x-ray spectroscopy is used to measure the spectral line shift of the 1s2p-1s^{2} transition in He-like Al ions as a function of the instantaneous plasma conditions. The plasma temperature and density are inferred from the Al He_{α} complex using a nonlocal-thermodynamic-equilibrium atomic physics model. The experimental spectra show a linearly increasing redshift for electron densities of 1-5×10^{23}cm^{-3}. The measured line shifts are broadly consistent with a generalized analytic line-shift model based on calculations of a self-consistent field ion-sphere model.

6.
Phys Rev E ; 95(6-1): 063206, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28709238

RESUMEN

Iron opacity calculations presently disagree with measurements at an electron temperature of ∼180-195 eV and an electron density of (2-4)×10^{22}cm^{-3}, conditions similar to those at the base of the solar convection zone. The measurements use x rays to volumetrically heat a thin iron sample that is tamped with low-Z materials. The opacity is inferred from spectrally resolved x-ray transmission measurements. Plasma self-emission, tamper attenuation, and temporal and spatial gradients can all potentially cause systematic errors in the measured opacity spectra. In this article we quantitatively evaluate these potential errors with numerical investigations. The analysis exploits computer simulations that were previously found to reproduce the experimentally measured plasma conditions. The simulations, combined with a spectral synthesis model, enable evaluations of individual and combined potential errors in order to estimate their potential effects on the opacity measurement. The results show that the errors considered here do not account for the previously observed model-data discrepancies.

8.
Phys Rev E ; 93(2): 023202, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26986427

RESUMEN

Recently, frequency-resolved iron opacity measurements at electron temperatures of 170-200 eV and electron densities of (0.7-4.0)×10(22)cm(-3) revealed a 30-400% disagreement with the calculated opacities [J. E. Bailey et al., Nature (London) 517, 56 (2015)]. The discrepancies have a high impact on astrophysics, atomic physics, and high-energy density physics, and it is important to verify our understanding of the experimental platform with simulations. Reliable simulations are challenging because the temporal and spatial evolution of the source radiation and of the sample plasma are both complex and incompletely diagnosed. In this article, we describe simulations that reproduce the measured temperature and density in recent iron opacity experiments performed at the Sandia National Laboratories Z facility. The time-dependent spectral irradiance at the sample is estimated using the measured time- and space-dependent source radiation distribution, in situ source-to-sample distance measurements, and a three-dimensional (3D) view-factor code. The inferred spectral irradiance is used to drive 1D sample radiation hydrodynamics simulations. The images recorded by slit-imaged space-resolved spectrometers are modeled by solving radiation transport of the source radiation through the sample. We find that the same drive radiation time history successfully reproduces the measured plasma conditions for eight different opacity experiments. These results provide a quantitative physical explanation for the observed dependence of both temperature and density on the sample configuration. Simulated spectral images for the experiments without the FeMg sample show quantitative agreement with the measured spectral images. The agreement in spectral profile, spatial profile, and brightness provides further confidence in our understanding of the backlight-radiation time history and image formation. These simulations bridge the static-uniform picture of the data interpretation and the dynamic-gradient reality of the experiments, and they will allow us to quantitatively assess the impact of effects neglected in the data interpretation.

9.
Nature ; 517(7532): 56-9, 2015 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-25557711

RESUMEN

Nearly a century ago it was recognized that radiation absorption by stellar matter controls the internal temperature profiles within stars. Laboratory opacity measurements, however, have never been performed at stellar interior conditions, introducing uncertainties in stellar models. A particular problem arose when refined photosphere spectral analysis led to reductions of 30-50 per cent in the inferred amounts of carbon, nitrogen and oxygen in the Sun. Standard solar models using the revised element abundances disagree with helioseismic observations that determine the internal solar structure using acoustic oscillations. This could be resolved if the true mean opacity for the solar interior matter were roughly 15 per cent higher than predicted, because increased opacity compensates for the decreased element abundances. Iron accounts for a quarter of the total opacity at the solar radiation/convection zone boundary. Here we report measurements of wavelength-resolved iron opacity at electron temperatures of 1.9-2.3 million kelvin and electron densities of (0.7-4.0) × 10(22) per cubic centimetre, conditions very similar to those in the solar region that affects the discrepancy the most: the radiation/convection zone boundary. The measured wavelength-dependent opacity is 30-400 per cent higher than predicted. This represents roughly half the change in the mean opacity needed to resolve the solar discrepancy, even though iron is only one of many elements that contribute to opacity.

10.
Phys Rev Lett ; 111(4): 045001, 2013 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-23931375

RESUMEN

Mixing of plastic ablator material, doped with Cu and Ge dopants, deep into the hot spot of ignition-scale inertial confinement fusion implosions by hydrodynamic instabilities is diagnosed with x-ray spectroscopy on the National Ignition Facility. The amount of hot-spot mix mass is determined from the absolute brightness of the emergent Cu and Ge K-shell emission. The Cu and Ge dopants placed at different radial locations in the plastic ablator show the ablation-front hydrodynamic instability is primarily responsible for hot-spot mix. Low neutron yields and hot-spot mix mass between 34(-13,+50) ng and 4000(-2970,+17 160) ng are observed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA