Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
J Clin Med ; 13(17)2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39274553

RESUMEN

Background: Precise implantation could play a crucial role in the technical success of transcatheter aortic valve replacement (TAVR) for some prostheses. The impact of an accidental implantation depth (ID) outside the recommended range has not been assessed for the ACURATE neo2 (NEO2). Methods: Data from 1839 patients with severe native aortic stenosis treated with the NEO2 prosthesis were evaluated. We compared the results of prostheses implanted in an ID both inside and outside the recommendations. The outcome assessment followed the Valve Academic Research Consortium-3 criteria. Results: Patients were retrospectively divided into high (<3 mm; n = 412), optimal (3-7 mm; n = 1236), and low (>7 mm; n = 169) implantations. Technical success (94.7% vs. 94.7% vs. 91.7%, p = 0.296) and device success were high (90.1% vs. 89.3% vs. 84.6%, p = 0.112) without differences between groups. Rates of relevant paravalvular regurgitation (PVL; >mild or VinV due to PVL) were comparable (1.2% vs. 1.8% vs. 1.2%, p = 0.759). Even when hemodynamics were superior in the high-implantation group, with greater iEOA (1.01 cm2/m2 vs. 0.95 cm2/m2 vs. 0.92 cm2/m2, p < 0.001), spontaneous embolization or after post-dilatation was more common. Low implantation was associated with a higher rate of associated pacemaker implantation (PPI) (6.1% vs. 8.8% vs. 14.8%, p = 0.001). Conclusions: Implantation with the ACURATE neo2 showed excellent hemodynamic results, including low gradients and a small number of relevant PVL, in line with a high technical success rate that was irrespective of the ID. A favorable outcome can also be achieved in accidental low or high positions. Low implantation was associated with a higher rate of associated pacemaker implantation. Deliberately high implantation should be avoided due to the risk of embolization.

2.
J Clin Med ; 13(14)2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39064227

RESUMEN

Background/Objectives: Previous trials reported comparable results with PASCAL and earlier MitraClip generations. Limited comparative data exist for more contemporary MitraClip generations, particularly the large MitraClip XT(R/W). We aimed to evaluate acute and 30-day outcomes in patients undergoing mitral valve transcatheter edge-to-edge repair (M-TEER) with one of the large devices, either PASCAL P10 or MitraClip XT(R/W) (3rd/4th generation). Methods: A total of 309 PASCAL-treated patients were matched by propensity score to 253 MitraClip-treated patients, resulting in 200 adequately balanced pairs. Procedural, clinical, and echocardiographic outcomes were collected for up to 30 days, including subgroup analysis for mitral regurgitation (MR) etiologies. Results: PASCAL and MitraClip patients were comparable regarding age (80 vs. 79 years), sex (female: 45.5% vs. 50.5%), and MR etiology (degenerative MR: n = 94, functional MR [FMR]: n = 96, mixed MR: n = 10 in each group). Technical success rates were comparable (96.5% vs. 96.0%; p > 0.999). At discharge, the mean gradient was higher (3.3 mmHg vs. 3.0 mmHg; p = 0.038), and the residual mitral valve orifice area was smaller in MitraClip patients (3.0 cm2 vs. 2.3 cm2; p < 0.001). At discharge, the reduction to MR ≤ 2+ was comparable (92.4% vs. 87.8%; p = 0.132). However, reduction to MR ≤ 1+ was more frequently observed in PASCAL patients (67.7% vs. 56.6%; p = 0.029), driven by the FMR subgroup (74.0% vs. 60.0%; p = 0.046). No difference was observed in 30-day mortality (p = 0.204) or reduction in NYHA-FC to ≤II (p > 0.999). Conclusions: Both M-TEER devices exhibited high and comparable rates of technical success and MR reduction to ≤2+. PASCAL may be advantageous in achieving MR reduction to ≤1+ in patients with FMR.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38860614

RESUMEN

BACKGROUND: Challenging anatomies and comorbidities have impact on success in transcatheter aortic valve replacement (TAVR). There is controversy whether the extent of the aortic angle (AA) has an impact on procedural outcomes. Matched comparative outcome data of new generation transcatheter heart valves (THVs) in horizontal aorta (HA) are scarce. METHODS: A total of 1582 patients with severe native aortic stenosis (AS) treated with the SAPIEN3 Ultra (Ultra; n = 526) or ACURATE Neo2 (Neo2; n = 1056) THVs from January 2017 to January 2023 were analyzed. Patients with non-horizontal aortas (AA < 51.7°, n = 841) were excluded. The population was matched by 1-to-1 nearest-neighbor matching (Ultra, n = 246; Neo2, n = 246). Clinical and procedural outcome were evaluated according to VARC-3 recommendations. RESULTS: Technical success (93.1% vs. 94.7%, p = 0.572) was high after Ultra and Neo2. Device success (80.5% vs. 89.8%, p = 0.05) was inferior with Ultra. Neo2 reveals superior hemodynamic properties with lower rate of severe prosthesis patient mismatch (12.0% vs. 3.7%, p = 0.001) and elevated gradients ( ≥ $\ge $ 20 mmHg: 11.9% vs. 1.7%, p < 0.001). Ultra showed a lower rate of relevant paravalvular regurgitation ( > $\gt $ mild paravalvular regurgitation or Valve-in-Valve due to paravalvular regurgitation: 0.0% vs. 3.7%, p = 0.004). The rate of procedural bailout maneuvers (0.8% vs. 0.4%, p = 1.000) and thirty-day all-cause mortality (1.3% vs. 2.2%, p = 0.496) was similar. CONCLUSION: Transfemoral TAVR in patients with severe aortic stenosis and HA, using the balloon expandable Sapien3 Ultra and self-expanding ACURATE Neo2 prosthesis, is feasible and safe. Therefore, valve selection between these platforms should be made irrespective of the aortic angle by a team experienced with both valves based on their specific advantages. Large, randomized trials in this sub-group of patients would be necessary to compare long term outcomes.

4.
Heart Lung Circ ; 33(9): 1272-1279, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38811293

RESUMEN

BACKGROUND: Diabetic patients with coronary artery disease may benefit from elective coronary artery bypass graft (CABG) surgery. It is unknown whether this merit is transferable to patients with acute myocardial infarction (AMI) undergoing surgery. METHOD: A total of 1,427 patients underwent CABG within 48 hours of being diagnosed with AMI at the current institution between 2001 and 2019. Of these patients, 206 (14.4%) had insulin-dependent diabetes mellitus (IDDM) and 148 (10.4%) had non-insulin dependent diabetes mellitus (NIDDM). Retrospective data analysis was performed. RESULTS: Patients with NIDDM showed the highest perioperative risk profile, with a EuroScore II of 11.6 (±10.3) compared with 7.8 (±8.0) in non-diabetic patients and 8.4 (±7.8) in patients with IDDM (p<0.001). Sub-analysis demonstrated a higher proportion of non-ST-elevation myocardial infarction patients in the NIDDM cohort compared with the IDDM cohort (70.9% vs 56.8%; p=0.005). Postoperatively, NIDDM patients had more sepsis (p<0.01) and longer ventilation times (p<0.001) compared with non-DM and IDDM patients (p<0.01). Wound healing complications were rare, but almost twice as high in NIDDM patients compared with non-DM and IDDM patients (4.7% vs 0.9% vs 2.4%, respectively). The 30-day mortality was highest in the NIDDM cohort (18.3% vs 11.3% vs 7.8%; p=0.012). Analysis of survival for up to 15 years revealed a significantly reduced survival of diabetic patients compared with non-diabetic patients, with lowest survival rates in NIDDM patients (p<0.001). CONCLUSIONS: Non-insulin dependent diabetes mellitus patients undergoing CABG within 48 hours of being diagnosed with AMI are at increased risk of short-term and long-term complications. Therefore, this particular group should undergo a careful evaluation concerning the expected risks and benefits of CABG in this setting.


Asunto(s)
Puente de Arteria Coronaria , Infarto del Miocardio , Humanos , Masculino , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/métodos , Femenino , Estudios Retrospectivos , Infarto del Miocardio/cirugía , Infarto del Miocardio/epidemiología , Infarto del Miocardio/complicaciones , Anciano , Persona de Mediana Edad , Factores de Tiempo , Factores de Riesgo , Diabetes Mellitus Tipo 2/complicaciones , Tasa de Supervivencia/tendencias , Estudios de Seguimiento , Complicaciones Posoperatorias/epidemiología , Diabetes Mellitus Tipo 1/complicaciones , Medición de Riesgo/métodos
5.
Circ Cardiovasc Interv ; 17(5): e013608, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38529637

RESUMEN

BACKGROUND: Comparative data on transcatheter self-expanding ACURATE neo2 (NEO2) and balloon-expandable SAPIEN 3 Ultra prostheses in technically challenging anatomy of severe aortic valve calcified aortic annuli are scarce. METHODS: A total of 1987 patients with severe native aortic stenosis treated with the self-expanding NEO2 (n=1457) or balloon-expandable SAPIEN 3 Ultra (n=530) from January 2017 to April 2023 were evaluated. The primary end point was procedural outcome according to the Valve Academic Research Consortium 3 definitions. Propensity matching defined 219 pairs with severe calcification (calcium density cutoff, 758 AU/cm2) of the native aortic valve. RESULTS: Technical success (90.4% versus 91.8%; risk difference, 1.4% [95% CI, -4.4 to -7.2]; P=0.737) and device success at 30 days (80.8% versus 75.8%; risk difference, -5.0% [95% CI, -13.2 to 3.1]; P=0.246) were comparable between NEO2 and SAPIEN 3 Ultra. The rate of severe prosthesis-patient mismatch (1.1% versus 10.1%; risk difference, 10.0% [95% CI, 4.0-13.9]; P<0.001) and mean transvalvular gradient ≥20 mm Hg (2.8% versus 14.3%; risk difference, 11.5% [95% CI, 5.8-17.1]; P<0.001) was lower with NEO2. The rate of more-than-mild paravalvular leakage or valve-in-valve due to paravalvular leakage was significantly higher (6.2% versus 0.0%; risk difference, 6.2% [95% CI, -10.1 to -2.7]; P=0.002), and there was a tendency for a higher rate of device embolization or migration (1.8% versus 0.0%; risk difference, -1.8% [95% CI, -4.1 to 0.4]; P=0.123) with NEO2. Multivarate regression revealed no independent impact of transcatheter heart valve selection on device success (odds ratio, 0.93 [95% CI, 0.48-1.77]; P=0.817). CONCLUSIONS: In patients with severely calcified annuli, supraannular implantation of NEO2 showed hemodynamic advantages. Nevertheless, NEO2 was associated with a higher incidence of relevant paravalvular leakage and a numerically higher rate of device embolization than SAPIEN 3 Ultra in this particular patient group.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Calcinosis , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Masculino , Femenino , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/patología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Calcinosis/diagnóstico por imagen , Calcinosis/cirugía , Resultado del Tratamiento , Factores de Riesgo , Factores de Tiempo , Medición de Riesgo , Estudios Retrospectivos , Puntaje de Propensión , Recuperación de la Función , Valvuloplastia con Balón/efectos adversos , Hemodinámica
6.
Front Cardiovasc Med ; 11: 1263905, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38343872

RESUMEN

In a female patient with acute cardiac decompensation, an auxiliary finding of a giant left atrium emerged. The surgical therapy of the atrial reduction, in addition to a mitral valve replacement and a coronary artery bypass grafting, is hereby presented.

8.
J Am Heart Assoc ; 12(24): e031881, 2023 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-38084735

RESUMEN

BACKGROUND: We previously reported procedural and 30-day outcomes of a German early multicenter experience with the PASCAL system for severe mitral regurgitation (MR). This study reports 1-year outcomes of mitral valve transcatheter edge-to-edge repair with the PASCAL system according to MR etiology in a large all-comer cohort. METHODS AND RESULTS: Clinical and echocardiographic outcomes up to 1-year were investigated according to MR etiology (degenerative [DMR], functional [FMR], or mixed [MMR]) in the first 282 patients with symptomatic MR 3+/4+ treated with the PASCAL implant at 9 centers in 2019. A total of 282 patients were included (33% DMR, 50% FMR, 17% MMR). At discharge, MR reduction to ≤1+/2+ was achieved in 58%/87% of DMR, in 75%/97% of FMR, and in 78%/98% of patients with MMR (P=0.004). MR reduction to ≤1+/2+ was sustained at 30 days (50%/83% DMR, 67%/97% FMR, 74%/100% MMR) and at 1 year (53%/78% DMR, 75%/97% FMR, 67%/91% MMR) with significant differences between etiologies. DMR patients with residual MR 3+/4+ at 1-year had at least complex valve morphology in 91.7%. Valve-related reintervention was performed in 7.4% DMR, 0.7% FMR, and 0.0% MMR (P=0.010). At 1-year, New York Heart Association Functional Class was significantly improved irrespective of MR etiology (P<0.001). CONCLUSIONS: In this large all-comer cohort, mitral valve transcatheter edge-to-edge repair with the PASCAL system was associated with an acute and sustained MR reduction at 1-year in all causes. However, in patients with DMR, MR reduction was less pronounced, reflecting the high incidence of complex or very complex anatomies being referred for mitral valve transcatheter edge-to-edge repair.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/etiología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Sistema de Registros , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Cateterismo Cardíaco/efectos adversos
9.
Cardiol J ; 30(6): 1003-1009, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37964645

RESUMEN

BACKGROUND: Patients with complex coronary artery disease (CAD) may benefit from surgical myocardial revascularization but weighing the risk of peri-operative complications against the expected merit is difficult. Minimally invasive direct artery bypass (MIDCAB) procedures are less invasive, provide the prognostic advantage of operative revascularization of the left anterior descending artery and may be integrated in hybrid strategies. Herein, the outcomes between patients with coronary 1-vessel disease (1-VD) and patients with 2-VD and 3-VD after MIDCAB procedures were compared in this single-center study. METHODS: Between 1998 and 2018, 1363 patients underwent MIDCAB at the documented institution. 628 (46.1%) patients had 1-VD, 434 (31.9%) patients 2-VD and 300 (22.0%) patients suffered from 3-VD. Data of patients with 2-VD, and 3-VD were pooled as multi-VD (MVD). RESULTS: Patients with MVD were older (66.2 ± 10.9 vs. 62.9 ± 11.2 years; p < 0.001) and presented with a higher EuroScore II (2.10 [0.4; 34.2] vs. 1.2 [0.4; 12.1]; p < 0.001). Procedure time was longer in MVD patients (131.1 ± 50.3 min vs. 122.2 ± 34.5 min; p < 0.001). Post-operatively, MVD patients had a higher stroke rate (17 [2.3%] vs. 4 [0.6%]; p = 0.014). No difference in 30-day mortality was observed (12 [1.6%] vs. 4 [0.6%]; p = 0.128). Survival after 15 years was significantly lower in MVD patients (p < 0.01). Hybrid procedures were planned in 295 (40.2%) patients with MVD and realized in 183 (61.2%) cases. MVD patients with incomplete hybrid procedures had a significantly decreased long-term survival compared to cases with complete revascularization (p < 0.01). CONCLUSIONS: Minimally invasive direct coronary artery bypass procedures are low-risk surgical procedures. If hybrid procedures have been planned, completion of revascularization should be a major goal.


Asunto(s)
Enfermedad de la Arteria Coronaria , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Puente de Arteria Coronaria/métodos , Estudios de Seguimiento , Resultado del Tratamiento , Revascularización Miocárdica/métodos
10.
J Clin Med ; 12(12)2023 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-37373693

RESUMEN

BACKGROUND: Third-generation transcatheter heart valves (THVs) are designed to improve outcomes. Data on the new intra-annular self-expanding NAVITOR are scarce. AIMS: The aim of this analysis was to compare outcomes between the PORTICO and the NAVITOR systems. METHODS: Data from 782 patients with severe native aortic stenosis treated with PORTICO (n = 645) or NAVITOR (n = 137) from 05/2012 to 09/2022 were evaluated. The clinical and hemodynamic outcomes of 276 patients (PORTICO, n = 139; NAVITOR, n = 137) were evaluated according to VARC-3 recommendations. RESULTS: Rates of postprocedural more-than-mild paravalvular leakage (PVL) were significantly lower for NAVITOR than for PORTICO (7.2% vs. 1.5%, p = 0.041). In addition, severe bleeding rates (27.3% vs. 13.1%, p = 0.005) and major vascular complications (5.8% vs. 0.7%, p = 0.036) were lower in the NAVITOR group. The mean gradients (7 vs. 8 mmHg, p = 0.121) and calculated aortic valve areas (1.90 cm2 vs. 1.99 cm2, p = 0.235) were comparable. Rates of PPI were similarly high in both groups (15.3 vs. 21.6, p = 0.299). CONCLUSIONS: The NAVITOR demonstrated favorable in-hospital procedural outcome data, with lower rates of relevant PVL, major vascular complications, and severe bleeding than its predecessor the PORTICO and preserved favorable hemodynamic outcomes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA