1.
Opt Lett ; 23(4): 289-91, 1998 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-18084488

RESUMEN

Two novel techniques for eliminating deterministic noise from a page-oriented memory are presented. The first technique equalizes the output response of ON pixels by adjustment of the exposure of each pixel during the recording of each data page. A test image transmitted through the system measures the spatial nonuniformities, and the appropriate inverse filter is imposed upon the data page and recorded in the storage material. On readout, the output signal values are then spatially uniform, perturbed only by random noise sources. Experimental results of using this predistortion technique in a pixel-matched holographic storage system are shown. Under conditions of high volumetric density, raw bit-error-rate (BER) improvements of 6-8 orders of magnitude are obtained (from 10(-4) to <10(-10)). The second technique uses a phase shift during holographic storage to subtract from bright OFF pixels. Under conditions of low spatial light modulator contrast, BER improvements of 6 orders of magnitude (from 10(-2) to 10(-8)) are demonstrated.

2.
Opt Lett ; 22(9): 639-41, 1997 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-18185616

RESUMEN

We describe a digital holographic storage system for the study of noise sources and the evaluation of modulation and error-correction codes. A precision zoom lens and Fourier transform optics provide pixel-to-pixel matching between any input spatial light modulator and output CCD array over magnifications from 0.8 to 3. Holograms are angle multiplexed in LiNbO(3):Fe by use of the 90 degrees geometry, and reconstructions are detected with a 60-frame/s CCD camera. Modulation codes developed on this platform permit image transmission down to signal levels of ~2000 photons per ON camera pixel, at raw bit-error rates (BER's) of better than 10(-5). Using an 8-12-pixel modulation code, we have stored and retrieved 1200 holograms (each with 45,600 user bits) without error, for a raw BER of <2x10(-8).

3.
Appl Opt ; 36(14): 3107-15, 1997 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-18253316

RESUMEN

We study the interpixel cross talk introduced to digital holographic data storage by use of a multilevel phase mask at the data-input plane. We evaluate numerically the intensity distribution at the output detector for Fourier plane hologram storage in a limited-aperture storage medium. Only the effect at an output pixel of interpixel cross talk from the four horizontal and vertical neighboring pixels is considered, permitting systematic evaluation of all possibilities. For random two-level and pseudorandom six-level phase masks, the influence of the pixel fill factor, as well as the aperture size of the storage medium, is studied. Our simulations show that, for a given aperture size, a random two-level mask is more susceptible to interpixel cross talk than is a pseudorandom six-level mask. Decreasing the pixel fill factor below 94% with a pseudorandom six-level phase mask makes it theoretically possible to have a system with no errors from interpixel cross talk if one particular 5-pixel pattern is forbidden through modulation coding. Reducing the input fill factor below 85% means that no patterns need to be excluded.

4.
Opt Lett ; 22(19): 1509-11, 1997 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-18188284

RESUMEN

Digital data-page holograms consisting of 1024 x 1024 arrays of binary pixels have been stored and subsequently retrieved with an optical exposure consistent with a data rate 1 Gbit /s. Each input pixel was precisely registered with a single detector pixel, and a raw bit-error rate as low as 2.4 x 10(-6) was demonstrated with global-threshold detection. To our knowledge, this is the first demonstration of the often-cited goal of holographic data storage of megabit data pages and a gigabit-per-second data rate.

5.
Opt Lett ; 21(12): 890-2, 1996 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-19876193

RESUMEN

We report high-contrast storage of 64-kbit digital data pages in a photorefractive polymer material. Singlepage writing, reading, and erasing operations were demonstrated with a dual-function-dopant polymeric material having a dark lifetime of several days. Data were reconstructed without error by use of several simple readout algorithms.

6.
Appl Opt ; 35(14): 2360-74, 1996 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-21085372

RESUMEN

The design and the realization of an advanced precision optical test stand for evaluating materials and developing tools and techniques for holographic digital data storage are described. This apparatus allows studies of holographic recording materials and recording physics to be performed in the context of practical data storage. The system concept, its implementation, and its performance are described, and examples of holographic storage in photorefractive materials are discussed.

7.
Appl Opt ; 23(18): 3202, 1984 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-18213148
8.
Opt Lett ; 8(7): 404-6, 1983 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-19718129

RESUMEN

The applicability of the technique of two-photon four-level photochemistry for the production of near-IR holograms is critically evaluated. Although the current best system (biacetyl in a polycyanoacrylate matrix) has low recording sensitivity, several applications of the material have been demonstrated. Hologram efficiencies of up to 70% recorded at 752 nm are shown. Recording of extended holographic images and production of holographic optical elements are demonstrated. Finally, we have recorded holograms directly with GaAlAs diode lasers.