Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
2.
J Hum Hypertens ; 23(3): 196-210, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18800143

RESUMEN

The Gemini-AALA (Australia, Asia, Latin America, Africa/Middle East) study evaluated the efficacy and safety of single-pill amlodipine/atorvastatin (Caduet) for the treatment of patients of diverse ethnicity with concomitant hypertension and dyslipidaemia. This was a 14-week, open-label study including patients from 27 countries across the Middle East, Asia-Pacific, Africa and Latin America. Eight dosage strengths of single-pill amlodipine/atorvastatin (5/10, 10/10, 5/20, 10/20, 5/40, 10/40, 5/80 and 10/80 mg) were titrated to improve blood pressure and lipid control. Blood pressure and lipid goals were determined according to the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure (JNC 7) and National Cholesterol Education Program Expert Panel on Detection, Evaluation, and Treatment of High Blood Cholesterol in Adults (NCEP ATP III) guidelines, respectively (blood pressure, <140/90 or <130/80 mm Hg; low-density lipoprotein cholesterol (LDL-C), <4.1 to <2.6 mmol l(-1) (<160 to <100 mgdl(-1))). Overall, 1649 patients received study medication. Most patients (91.4%) had >or=1 cardiovascular risk factor (as defined by NCEP ATP III guidelines) in addition to hypertension/dyslipidaemia, and 61.7% had coronary heart disease/risk equivalent. At baseline, mean blood pressure was 146.6/88.3 mm Hg and LDL-C was 3.4 mmol l(-1) (130.2 mgdl(-1)). At week 14, 55.2% of patients reached both blood pressure and lipid goals, 61.3% reached blood pressure goal and 87.1% reached lipid goal (34.0% were at lipid goal at baseline). Mean blood pressure reduction was 20.2/11.4 mm Hg. For patients who were lipid-lowering drug naive at baseline, mean reduction in LDL-C was 41.0%. Treatment-related adverse events led to the discontinuation of 3.6% of patients. Single-pill amlodipine/atorvastatin therapy was well tolerated and effective for the reduction of blood pressure and lipids to recommended goals in patients from diverse ethnic backgrounds.


Asunto(s)
Amlodipino/uso terapéutico , Antihipertensivos/uso terapéutico , Presión Sanguínea/efectos de los fármacos , LDL-Colesterol/sangre , Dislipidemias/tratamiento farmacológico , Ácidos Heptanoicos/uso terapéutico , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Hipertensión/tratamiento farmacológico , Pirroles/uso terapéutico , Administración Oral , Anciano , Amlodipino/administración & dosificación , Amlodipino/efectos adversos , Antihipertensivos/administración & dosificación , Antihipertensivos/efectos adversos , Atorvastatina , Enfermedades Cardiovasculares/etnología , Enfermedades Cardiovasculares/etiología , Enfermedades Cardiovasculares/prevención & control , Combinación de Medicamentos , Dislipidemias/sangre , Dislipidemias/complicaciones , Dislipidemias/etnología , Femenino , Ácidos Heptanoicos/administración & dosificación , Ácidos Heptanoicos/efectos adversos , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/administración & dosificación , Inhibidores de Hidroximetilglutaril-CoA Reductasas/efectos adversos , Hipertensión/complicaciones , Hipertensión/etnología , Hipertensión/fisiopatología , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Estudios Prospectivos , Pirroles/administración & dosificación , Pirroles/efectos adversos , Resultado del Tratamiento
3.
Echocardiography ; 12(4): 335-49, 1995 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-10150780

RESUMEN

UNLABELLED: This study was carried out to select before permanent pacemaker implantation patients with complete atrioventricular block (CHB) who would benefit best from DDD pacing, and to determine the optimal atrioventricular delay (AVD) for each of those patients. This was achieved with the aid of Doppler echocardiography. The effect of different AVDs on both the systolic and diastolic function of the normal and failing heart was also delineated in this study. METHODS: Thirty patients with CHB and normal sinoatrial function were selected, with no age or sex predilection. These patients were categorized into three equal groups: groups A, B, and C with normal left ventricular (LV) systolic and diastolic function, LV diastolic dysfunction, and LV systolic dysfunction, respectively. For each patient, systolic and diastolic function was calculated utilizing echo Doppler during CHB, temporary VDD pacing with different AVDs, and temporary VVI pacing with a rate matching that during VDD mode. Temporary VDD mode of pacing was performed utilizing a temporary bipolar ventricular lead for ventricular pacing and an esophageal lead for atrial sensing to trigger ventricular pacing. RESULTS: Qualitatively the most obvious change in the pattern of LV filling as AVD is increased in the three groups, is the earlier occurrence of active atrial filling A wave due to progressive approximation of the ECG P wave toward the previous QRS. As the AV interval is increased, the following changes occur: (a) A wave occurs progressively earlier with superimposition onto the early filling E wave resulting in a progressive increase in its velocity (VA), its FVI, and its percent atrial contribution (%AC); (b) the three times diastolic filling time (DFT), mitral valve opening to Q wave (MVO-Q), and closure (Q-MVC) progressively shorten; (c) since DFT decreases, less passive filling occurs early during diastole, thus E.FVI decrease with longer AV intervals; (d) the ratios VE/VA and FVI E/A decrease subsequently to the previous described changes. Compared to CHB, percent ejection fraction (% EF) was not significantly changed during VVI pacing. Percent EF increased significantly during VDD in comparison to VVI pacing modes. Percent EF was highest at optimal AVD and decreased as this AVD increased or decreased. The cardiac output (CO) increment during VDD in comparison to VVI pacing modes differed much among the three groups. In group A, a 10.29% increase in CO was seen when comparing VDD pacing (with optimal AVD) with that of VII one; in group B, this increment was much greater and reached 29.48%; in group C it reached 23.68%.(ABSTRACT TRUNCATED AT 400 WORDS)


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Circulación Coronaria/fisiología , Ecocardiografía Doppler , Bloqueo Cardíaco/fisiopatología , Velocidad del Flujo Sanguíneo , Diástole/fisiología , Electrocardiografía , Bloqueo Cardíaco/terapia , Humanos , Marcapaso Artificial , Sístole/fisiología
4.
Pacing Clin Electrophysiol ; 15(11 Pt 2): 1804-8, 1992 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-1279551

RESUMEN

The pacing rate response of a new acceleration driven pulse generator (SWING 100, SORIN BIOMEDICA) was compared with simultaneous normal sinus rhythm (NSR) during two different treadmill exercises. This pacemaker has a gravitational acceleration sensor able to discriminate between physical activities and vibrations. Six healthy volunteers (three male, three female; aged 21.7 +/- 4.3 years), with the pacemaker strapped to their right infraclavicular area, performed each test three times with different rise response curve (RRC) each time: fast, normal, and slow. The fall response curve used was the same as the rising one during each test. Pacing rates were recorded using the VEGA analyzer (SORIN BIOMEDICA) and compared with simultaneous NSR recorded by a 7-channel ECG recorder (MINGOGRAF 7, SIEMENS). During all tests immediate (within seconds) rapid increase in pacemaker rate was seen up to about 60 seconds, then a slower increase followed thereafter. The mean correlation between pacing rates and NSR during the Bruce tests were 0.7941 +/- 0.10, 0.8562 +/- 0.14, and 0.8292 +/- 0.07; during the discontinuous tests 0.7292 +/- 0.16, 0.7233 +/- 0.10, and 0.7480 +/- 0.11 for fast, normal, and slow RRC, respectively. Each 30 seconds, nonsignificant differences were present between pacing rate and NSR during all the discontinuous tests; similar responses were observed only during the first two stages of Bruce tests after which NSR was significantly higher than pacemaker rates. The speed of rise to upper rate was the main difference between the different programs (fast, normal, and slow). The discontinuous tests showed that the pacemaker responds more to speed than to grade.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Frecuencia Cardíaca/fisiología , Marcapaso Artificial , Aceleración , Adulto , Algoritmos , Electrocardiografía , Diseño de Equipo , Ejercicio Físico/fisiología , Prueba de Esfuerzo , Femenino , Humanos , Masculino
5.
Eur Heart J ; 13(3): 366-72, 1992 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-1597224

RESUMEN

A significant proportion of individuals with rheumatic disease have tricuspid valve involvement which may be clinically important and alter the medical or surgical approach to treatment. Therefore 50 patients with rheumatic left-sided valvular lesions who were referred for operative treatment were studied. Thirty patients had angiographically significant tricuspid regurgitation (group I) and 20 had a competent tricuspid valve (group II). Pre-operative cardiac assessment included Doppler echocardiography and contrast ventriculography. Patients with tricuspid regurgitation more commonly had mitral valve disease or combined mitral and aortic valve lesions, (P less than 0.001) and were more likely to have atrial fibrillation than those without tricuspid regurgitation (P less than 0.001). Pulmonary arterial systolic and mean right atrial pressures were higher in group I (both P less than 0.01). A close relationship was found between the angiographic and Doppler assessment of the degree of tricuspid regurgitation (P less than 0.01). Doppler-derived measurement of the right ventricular-right atrial systolic pressure difference correlated well with the systolic trans-tricuspid pressure difference measured at cardiac catheterization (y = 0.7x + 22, r = 0.67, P less than 0.001) and the pulmonary arterial systolic pressure (y = 0.8x + 27, r = 0.71, P less than 0.001). Rheumatic involvement of the tricuspid valve identified by pre-operative echocardiography was confirmed in five patients at surgery. Of the 13 patients with functional tricuspid regurgitation at operation, only two had been diagnosed as having organic disease by echocardiography. Furthermore, in all 18 cases where Doppler suggested grade 3 or 4+ tricuspid regurgitation, surgical repair or replacement of the valve was performed.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Válvula Aórtica/cirugía , Válvula Mitral/cirugía , Cardiopatía Reumática/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Función Ventricular Derecha , Adolescente , Adulto , Válvula Aórtica/diagnóstico por imagen , Aortografía , Niño , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Hemodinámica , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Ventriculografía con Radionúclidos , Cardiopatía Reumática/diagnóstico por imagen , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/fisiopatología , Ultrasonografía
6.
J Am Coll Cardiol ; 5(4): 983-8, 1985 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-3973302

RESUMEN

Endomyocardial fibrosis is a disease of unknown origin which has not previously been described in detail from the Middle East. The clinical, echocardiographic, hemodynamic and angiocardiographic findings in eight patients (five men and three women, mean age 38 years) are presented. Two patients had right-sided involvement, two had left-sided involvement and four had biventricular involvement. The presence of a small ventricle with obliteration of the apex and a large atrium is a two-dimensional echocardiographic finding highly suggestive of endomyocardial fibrosis. Hemodynamic characteristics of dip and plateau on ventricular pressure curves were present in six patients. Ventricular angiography was diagnostic in all cases. Endomyocardial biopsy yielded positive findings in three of six patients and is not essential for diagnosis.


Asunto(s)
Fibrosis Endomiocárdica/fisiopatología , Adulto , Ecocardiografía , Electrocardiografía , Endocardio/patología , Fibrosis Endomiocárdica/diagnóstico por imagen , Fibrosis Endomiocárdica/patología , Femenino , Estudios de Seguimiento , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Radiografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...