Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 408
Filtrar
1.
JACC Cardiovasc Interv ; 17(18): 2093-2112, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39322362
2.
JACC Cardiovasc Interv ; 17(18): 2170-2179, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39322365

RESUMEN

BACKGROUND: Transcatheter tricuspid valve intervention (TTVI) has been increasingly adopted in recent years for the treatment of patients with tricuspid regurgitation (TR). However, no dedicated risk stratification has been established for patients undergoing TTVI. OBJECTIVES: The aim of the present study was to propose a dedicated risk score for patients affected by severe TR undergoing TTVI. METHODS: The score was derived from the TRIVALVE (International Multisite Transcatheter Tricuspid Valve Therapies Registry; NCT03416166) registry, according to data availability. A stepwise model approach was used on predictor variables to develop a scoring system for predicting 12-month mortality or rehospitalization using multivariable logistic regression. Internal discrimination, calibration, and validation were assessed using receiver-operating characteristic curve analysis and bootstrapping with 1,000 resamples. RESULTS: A total of 483 patients were included in the study, with an overall 12-month mortality or rehospitalization rate of 19% (n = 94). The final risk score, ranging from 0 to 4.5, included the following 5 parameters (adjusted for age and gender): 1) atrial fibrillation at baseline; 2) glomerular filtration rate <30 mL/min; 3) elevated gamma-glutamyl transferase/bilirubin levels; 4) signs of right heart failure; and 5) left ventricular ejection fraction <50%. The bias-corrected area under the receiver-operating characteristic curve was 68% (95% CI: 62%-75%). A cutoff value of 2.5 demonstrated sensitivity of 65.4% and specificity of 60.5% for the outcome. CONCLUSIONS: The present study proposes a dedicated risk score for patients undergoing TTVI, providing an additional and simple tool for heart teams to select the best therapy for patients affected by severe TR.


Asunto(s)
Cateterismo Cardíaco , Técnicas de Apoyo para la Decisión , Implantación de Prótesis de Válvulas Cardíacas , Readmisión del Paciente , Valor Predictivo de las Pruebas , Sistema de Registros , Índice de Severidad de la Enfermedad , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Medición de Riesgo , Masculino , Femenino , Factores de Riesgo , Anciano , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/mortalidad , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Factores de Tiempo , Anciano de 80 o más Años , Resultado del Tratamiento , Reproducibilidad de los Resultados , Toma de Decisiones Clínicas , Persona de Mediana Edad
3.
Artículo en Inglés | MEDLINE | ID: mdl-39297852

RESUMEN

BACKGROUND: The development and progression of aortic stenosis (AS) from aortic valve (AV) sclerosis is highly variable and difficult to predict. OBJECTIVES: The authors investigated whether a previously validated echocardiography-based deep learning (DL) model assessing diastolic dysfunction (DD) could identify the latent risk associated with the development and progression of AS. METHODS: The authors evaluated 898 participants with AV sclerosis from the ARIC (Atherosclerosis Risk In Communities) cohort study and associated the DL-predicted probability of DD with 2 endpoints: 1) the new diagnosis of AS; and 2) the composite of subsequent mortality or AV interventions. Validation was performed in 2 additional cohorts: 1) in 50 patients with mild-to-moderate AS undergoing cardiac magnetic resonance (CMR) imaging and serial echocardiographic assessments; and 2) in 18 patients with AV sclerosis undergoing 18F-sodium fluoride (NaF) and 18F-fluorodeoxyglucose positron emission tomography (PET) combined with computed tomography (CT) to assess valvular inflammation and calcification. RESULTS: In the ARIC cohort, a higher DL-predicted probability of DD was associated with the development of AS (adjusted HR: 3.482 [95% CI: 2.061-5.884]; P < 0.001) and subsequent mortality or AV interventions (adjusted HR: 7.033 [95% CI: 3.036-16.290]; P < 0.001). The multivariable Cox model (incorporating the DL-predicted probability of DD) derived from the ARIC cohort efficiently predicted the progression of AS (C-index: 0.798 [95% CI: 0.648-0.948]) in the CMR cohort. Moreover, the predictions of this multivariable Cox model correlated positively with valvular 18F-NaF mean standardized uptake values in the PET/CT cohort (r = 0.62; P = 0.008). CONCLUSIONS: Assessment of DD using DL can stratify the latent risk associated with the progression of early-stage AS.

4.
JACC Cardiovasc Interv ; 17(18): 2113-2122, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39243264

RESUMEN

BACKGROUND: Tricuspid regurgitation (TR) is a common valve disease that has a significant impact on patients' quality of life. OBJECTIVES: This study sought to report the final 3-year outcomes of tricuspid transcatheter edge-to-edge repair (T-TEER) with the TriClip (Abbott) implant from the TRILUMINATE (TRILUMINATE Study With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater TR) study for the treatment of severe symptomatic TR. METHODS: The TRILUMINATE study (N = 98 subjects) is an international, prospective, single-arm, multicenter study to investigate the safety and performance of T-TEER with the TriClip implant in patients with symptomatic moderate or greater TR. Echocardiographic assessments were performed at a core laboratory. RESULTS: At 3 years, TR was reduced to moderate or less in 79% of subjects, and a reduction of at least 1 grade was achieved in 92% of subjects. TR reduction achieved at 1 year was sustained through 3 years. Subjects also experienced an improvement in heart failure symptoms assessed by NYHA functional class and quality of life assessed by the Kansas City Cardiomyopathy Questionnaire at 3 years compared to baseline. The site-reported heart failure hospitalization rate decreased from 0.56 events/patient-year 1 year before device implantation to 0.14 events/patient-year 3 years after device implantation, representing a reduction of 75% (P < 0.0001). CONCLUSIONS: In the longest follow-up to date of any T-TEER therapy, the TRILUMINATE study demonstrated that the TriClip procedure is both safe and effective, with sustained benefits at 3 years in subjects with symptomatic moderate or greater TR. (TRILUMINATE Study With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater TR [TRILUMINATE]; NCT03227757).


Asunto(s)
Cateterismo Cardíaco , Calidad de Vida , Recuperación de la Función , Índice de Severidad de la Enfermedad , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Femenino , Estudios Prospectivos , Resultado del Tratamiento , Masculino , Anciano , Factores de Tiempo , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Persona de Mediana Edad , Válvula Tricúspide/cirugía , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/diagnóstico por imagen , Diseño de Prótesis , Anciano de 80 o más Años , Estados Unidos , Europa (Continente) , Estado Funcional
5.
J Am Coll Cardiol ; 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39222896

RESUMEN

BACKGROUND: TRILUMINATE Pivotal is a prospective, randomized, controlled study of patients with severe tricuspid regurgitation (TR). Venous congestion due to TR may lead to end-organ dysfunction and failure. The potential to reverse or stop further deterioration in end-organ function is an important goal of treatment. OBJECTIVES: Examine changes in end-organ function after tricuspid transcatheter edge-to-edge repair (TEER) and assess the association of baseline end-organ function with heart failure (HF) hospitalizations and mortality. METHODS: Subjects were randomized 1:1 to either the TEER group (TriClip™ System + medical therapy) or Control group (medical therapy alone). Laboratory assessments and TR grading were performed at baseline and at all follow-up visits (discharge, 30 days, 6 months, and 12 months). An independent echocardiography core laboratory assessed TR severity and an independent clinical events committee adjudicated adverse events. RESULTS: 572 subjects were enrolled and randomized (285 TEER, 287 Control). Patients with moderate to severe end-organ impairment (eGFR <45 ml/min/1.73m2 or MELD-XI >15) at baseline had increased incidence of HF hospitalization and death through 12 months, regardless of treatment. There were no statistically significant differences between TEER and Control in eGFR or MELD-XI at 12 months. In subgroup analyses examining only successful TEER patients (moderate or less TR at discharge) compared to control patients, as well as when censoring patients with normal baseline values, both eGFR (+3.55 ± 1.04 vs 0.07 ± 1.10 , p=0.022) and MELD-XI (-0.52 ± 0.18 vs 0.34 ± 0.18, p=0.0007) improved. CONCLUSIONS: Baseline end-organ function were associated with HF hospitalization and death in patients with severe TR. At 12 months, eGFR and MELD-XI scores were not statistically significantly different between the overall TEER and Control groups. In patients who had successful TEER, statistically significant, yet small, favorable changes occurred for both eGFR and MELD-XI. Further investigation is needed to assess whether these changes in end-organ function after successful TEER are clinically meaningful and reduce HF hospitalization or death.

7.
Artículo en Inglés | MEDLINE | ID: mdl-39207336

RESUMEN

BACKGROUND: Two subtypes of atrial functional mitral regurgitation (AFMR) have been described, one is characterized by Carpentier type I and the other by Carpentier type IIIb leaflet motion. OBJECTIVES: The authors sought to analyze echocardiographic characteristics and outcomes of AFMR subtypes undergoing mitral valve transcatheter edge-to-edge repair (M-TEER). METHODS: Of 1,047 consecutive patients who underwent M-TEER, the authors identified those with isolated mitral annulus dilation (Carpentier I), termed AFMR-IAD, and those with atriogenic hamstringing characterized by restricted posterior mitral leaflet motion (Carpentier IIIb), termed AFMR-AH. Echocardiographic baseline characteristics and outcomes up to 1-year were analyzed. RESULTS: A total of 128 patients (12.2%) met AFMR criteria; 75 (58.6%) were identified as AFMR-IAD and 53 (41.4%) as AFMR-AH. AFMR-AH displayed greater left atrial and left ventricular volumes, greater mitral annulus, shorter and steeper posterior mitral leaflet, and more pronounced MR (all P < 0.05). Technical success was achieved in 98.7% (AFMR-IAD) and 86.8% (AFMR-AH) of patients (P = 0.009). At discharge, device detachments were exclusively observed in AFMR-AH (10.0%). MR ≤II was achieved in 95.6% and 78.6% at 30 days (P = 0.009) and in 93.0% and 74.1% at 1 year (P = 0.038) in patients with AFMR-IAD and AFMR-AH, respectively. AFMR-AH was associated with procedural failure (OR: 1.17 [95% CI: 1.00-1.38]; P = 0.045) at 30 days (43.4% vs 24.0%; P = 0.023) and all-cause mortality (HR: 2.54 [95% CI: 1.09-5.91]; P = 0.031) at 1 year (77% vs 92%, Kaplan-Meier estimated 1-year survival; P = 0.017). CONCLUSIONS: AFMR-AH shows worse procedural and clinical outcomes following M-TEER than AFMR-IAD. Thus, vigilance regarding this pathology is warranted and alternative mitral valve therapies might need to be considered.

8.
JACC Cardiovasc Interv ; 17(16): 1916-1931, 2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-39197990

RESUMEN

BACKGROUND: Tricuspid regurgitation (TR) is highly prevalent in the transcatheter aortic valve replacement (TAVR) population, but clear management guidelines are lacking. OBJECTIVES: The aims of this study were to elucidate the prevalence and consequences of severe TR in patients with aortic stenosis undergoing TAVR and to examine the change in TR post-TAVR, including predictors of improvement and its impact on longer term mortality. METHODS: Using Centers for Medicare and Medicaid Services-linked TVT (Transcatheter Valve Therapy) Registry data, a propensity-matched analysis was performed among patients undergoing TAVR with baseline mild, moderate, or severe TR. Kaplan-Meier estimates were used to assess the impact of TR on 3-year mortality. Multivariable analysis identified predictors of 30-day TR improvement. RESULTS: Of the 312,320 included patients, 84% had mild, 13% moderate, and 3% severe TR. In a propensity-matched cohort, severe baseline TR was associated with higher in-hospital mortality (2.5% vs 2.1% for moderate TR and 1.8% for mild TR; P = 0.009), higher 1-year mortality (24% vs 19.6% for moderate TR and 16.6% for mild TR; P < 0.0001), and 3-year mortality (54.2% vs 48.5% for moderate TR and 43.3% for mild TR; P < 0.0001). Among the patients with severe TR at baseline, 76.4% improved to moderate or less TR 30 days after TAVR. Baseline mitral regurgitation moderate or greater, preserved ejection fraction, higher aortic valve gradient, and better kidney function predicted TR improvement after TAVR. However, severe 30-day residual TR was associated with higher 1-year mortality (27.4% vs 18.7% for moderate TR and 16.8% for mild TR; P < 0.0001). CONCLUSIONS: Severe baseline and 30-day residual TR after TAVR are associated with increased mortality up to 3 years. This analysis identifies a higher risk group that could be evaluated for the recently approved tricuspid interventions.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Mortalidad Hospitalaria , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Insuficiencia de la Válvula Tricúspide , Humanos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano de 80 o más Años , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/mortalidad , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Anciano , Estados Unidos/epidemiología , Factores de Riesgo , Factores de Tiempo , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Valvuloplastia con Balón/mortalidad , Valvuloplastia con Balón/efectos adversos , Medición de Riesgo , Prevalencia , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Estudios Retrospectivos , Centers for Medicare and Medicaid Services, U.S. , Hemodinámica
9.
J Am Coll Cardiol ; 84(9): 832-847, 2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39168570

RESUMEN

Pathologic left ventricular remodeling and valvular heart disease may contribute to the clinical presentation and outcomes of patients presenting with heart failure, and limit the effectiveness of guideline-directed medical therapy. Although surgical interventions including surgical ventricular restoration techniques and valve repair or replacement are effective therapies, there is growing evidence that transcatheter interventions may be options for patients with persistent symptoms of heart failure despite optimal medical therapy, where surgical options may be limited. This scientific statement will review the current available and investigational percutaneous strategies for the management of structural contributors to heart failure: dilated left ventricular cardiomyopathies and valvular heart disease.


Asunto(s)
Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/terapia , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/terapia , Procedimientos Quirúrgicos Cardíacos/métodos , Cardiomiopatía Dilatada/terapia , Cardiomiopatía Dilatada/fisiopatología
10.
Eur Heart J Case Rep ; 8(8): ytae261, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39113778

RESUMEN

Background: Limited data exist on strain changes after transcatheter aortic valve implantation (TAVI) in patients with aortic regurgitation (AR). Case summary: Three patients with AR undergoing TAVI showed an initial reduction in global longitudinal strain (GLS), followed by sustained GLS improvement within the first year. Discussion: Findings align with those of surgically treated patients with AR. There is a possible superiority of GLS to left ventricular end-diastolic diameter ratio in assessing patients with severe volume overload.

11.
Artículo en Inglés | MEDLINE | ID: mdl-39189600

RESUMEN

AIMS: Transcatheter tricuspid valve interventions (TTVI) are increasingly used to treat patients with significant tricuspid regurgitation (TR). The evolution of concurrent mitral regurgitation (MR) severity after TTVI is currently unknown and may be pivotal for clinical decision-making. The aim of this study was to assess the evolution of MR after TTVI and to identify predictors of MR worsening and improvement. METHODS AND RESULTS: This analysis is a substudy of the Trivalve Registry, an international registry designed to collect data on TTVI. This substudy included all patients with echocardiographic data on MR evolution and excluded those with a concomitant tricuspid and mitral transcatheter valve intervention or with a history of mitral valve intervention. The co-primary outcomes were MR improvement and worsening at two timepoints: pre-discharge and 2-month follow-up. This analysis included 359 patients with severe TR, mostly(80%) treated with tricuspid transcatheter edge-to-edge repair(T-TEER). MR improvement was found in 106(29.5%) and 99(34%) patients, while MR worsening in 34(9.5%) and 33(11%) patients at pre-discharge and 2-month follow-up, respectively. Annuloplasty and heterotopic replacement were associated with MR worsening. Independent predictors of MR improvement were: atrial fibrillation, T-TEER, acute procedural success, TR reduction, LVEDD>60 mm and beta-blocker therapy. Patients with moderate-to-severe/severe MR following TTVI showed significantly higher death rates. CONCLUSION: MR degree variation is common after TTVI, with most cases showing improvement. Clinical and procedural characteristics may predict the MR evolution, in particular procedural success and T-TEER play key roles in MR outcomes. TTVI may be beneficial even in the presence of functional MR.

12.
JACC Cardiovasc Interv ; 17(17): 2041-2051, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39177555

RESUMEN

BACKGROUND: A prior Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry-based analysis reported similar 1-year clinical outcomes with small (20-mm) vs large (≥23-mm) balloon-expandable valves (BEV). OBJECTIVES: The aim of this study was to describe mid-term 3-year clinical outcomes for small vs large BEV and the relationship between discharge echocardiographic mean gradient (MG) and different definitions of prothesis-patient mismatch (PPM) with clinical outcomes. METHODS: Using the TVT Registry with Centers for Medicare and Medicaid Services linkage, a propensity-matched analysis of patients receiving 20- vs ≥23-mm BEVs was performed. Spline curves and Kaplan-Meier plots with adjusted HRs determined the relationship between MG and 3-year mortality. RESULTS: In total, 316,091 patients were analyzed; after propensity matching, 8,100 pairs of each group were compared. The 20-mm BEV was associated with higher MGs compared with ≥23-mm BEVs (16.2 ± 7.2 mm Hg vs 11.8 ± 5.7 mm Hg; P < 0.0001). At 3 years, there was no difference in mortality between 20- and ≥23-mm BEVs (31.5% vs 32.5%, respectively; HR: 0.97; 95% CI: 0.90-1.05). Compared with an MG of 10 to 30 mm Hg, an MG <10 mm Hg (HR: 1.25; 95% CI:1.22-1.27) was associated with increased 3-year mortality. Measured severe PPM and predicted no PPM were associated with increased 3-year mortality (33.5% vs 32.9% vs 32.1%; P < 0.0001) and (33.5% vs 31.1% vs 30%; P < 0.0001), respectively. Low MG and severe measured PPM were associated with lower left ventricular ejection fraction (LVEF). CONCLUSIONS: Patients with small-prosthesis BEVs (20 mm) had identical 3-year survival as those with larger (≥23-mm) BEV valves. Severe measured PPM and low MG (<10 mm Hg), but not predicted severe PPM, were associated with lower LVEF and increased mortality, suggesting that LVEF is the culprit for worse outcomes.


Asunto(s)
Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Humanos , Masculino , Femenino , Factores de Tiempo , Resultado del Tratamiento , Anciano , Factores de Riesgo , Estados Unidos , Valvuloplastia con Balón/mortalidad , Valvuloplastia con Balón/efectos adversos , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Medición de Riesgo , Hemodinámica , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Recuperación de la Función , Estudios Retrospectivos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad
14.
J Am Coll Cardiol ; 84(2): 195-212, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38960514

RESUMEN

Heart failure with preserved ejection fraction (HFpEF) is associated with high morbidity and mortality. Important risk factors for the development of HFpEF are similar to risk factors for the progression of tricuspid regurgitation (TR), and both conditions frequently coexist and thus is a distinct phenotype or a marker for advanced HF. Many patients with severe, symptomatic atrial secondary TR have been enrolled in current transcatheter device trials, and may represent patients at an advanced stage of HFpEF. Management of HFpEF thus may affect the pathophysiology of TR, and the physiologic changes that occur following transcatheter treatment of TR, may also impact symptoms and outcomes in patients with HFpEF. This review discusses these issues and suggests possible management strategies for these patients.


Asunto(s)
Insuficiencia Cardíaca , Volumen Sistólico , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Volumen Sistólico/fisiología
15.
Artículo en Inglés | MEDLINE | ID: mdl-38970594

RESUMEN

3-dimensional (3D) intracardiac echocardiography (ICE) is emerging as a promising complement and potential alternative to transesophageal echocardiography for imaging guidance in structural heart interventions. To establish standardized practices, our multidisciplinary expert position statement serves as a comprehensive guide for the appropriate indications and utilization of 3D-ICE in various structural heart procedures. The paper covers essential aspects such as the fundamentals of 3D-ICE imaging, basic views, and workflow recommendations specifically tailored for ICE-guided structural heart procedures, such as transeptal puncture, device closure of intracardiac structures, and transcatheter mitral and tricuspid valve interventions. Current challenges, future directions, and training requirements to ensure operator proficiency are also discussed, thereby promoting the safety and efficacy of this innovative imaging modality to support expanding its future clinical applications.

16.
Artículo en Inglés | MEDLINE | ID: mdl-39066744

RESUMEN

BACKGROUND: New postprocessing software facilitates 3-dimensional (3D) echocardiographic determination of mitral annular (MA) and neo-left ventricular outflow tract (neo-LVOT) dimensions in patients undergoing transcatheter mitral valve replacement (TMVR). OBJECTIVES: This study aims to test the accuracy of 3D echocardiographic analysis as compared to baseline computed tomography (CT). METHODS: A total of 105 consecutive patients who underwent TMVR at 2 tertiary care centers between October 2017 and May 2023 were retrospectively included. A virtual valve was projected in both baseline CT and 3D transesophageal echocardiography (TEE) using dedicated software. MA dimensions were measured in baseline images and neo-LVOT dimensions were measured in baseline and postprocedural images. All measurements were compared to baseline CT as a reference. The predicted neo-LVOT area was correlated with postprocedural peak LVOT gradients. RESULTS: There was no significant bias in baseline neo-LVOT prediction between both imaging modalities. TEE significantly underestimated MA area, perimeter, and medial-lateral dimension compared to CT. Both modalities significantly underestimated the actual neo-LVOT area (mean bias pre/post TEE: 25.6 mm2, limit of agreement: -92.2 mm2 to 143.3 mm2; P < 0.001; mean bias pre/post CT: 28.3 mm2, limit of agreement: -65.8 mm2 to 122.4 mm2; P = 0.046), driven by neo-LVOT underestimation in the group treated with dedicated mitral valve bioprosthesis. Both CT- and TEE-predicted-neo-LVOT areas exhibited an inverse correlation with postprocedural LVOT gradients (r2 = 0.481; P < 0.001 for TEE and r2 = 0.401; P < 0.001 for CT). CONCLUSIONS: TEE-derived analysis provides comparable results with CT-derived metrics in predicting the neo-LVOT area and peak gradient after TMVR.

17.
Circ Cardiovasc Interv ; 17(8): e013782, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39034924

RESUMEN

BACKGROUND: Transcatheter mitral valve-in-valve replacement offers a less-invasive alternative for high-risk patients with bioprosthetic valve failure. Limited experience exists in intermediate-risk patients. We aim to evaluate 1-year outcomes of the PARTNER 3 mitral valve-in-valve study. METHODS: This prospective, single-arm, multicenter study enrolled symptomatic patients with a failing mitral bioprosthesis demonstrating greater than or equal to moderate stenosis and regurgitation and Society of Thoracic Surgeons score ≥3% and <8%. A balloon-expandable transcatheter heart valve (SAPIEN 3, Edwards Lifesciences) was used via a transeptal approach. The primary end point was the composite of all-cause mortality and stroke at 1 year. RESULTS: A total of 50 patients from 12 sites underwent mitral valve-in-valve from 2018 to 2021. The mean age was 70.1±9.7 years, mean Society of Thoracic Surgeons score was 4.1%±1.6%, and 54% were female. There were no primary end point events (mortality or stroke) through 1 year, and no left-ventricular outflow tract obstruction, endocarditis, or mitral valve reintervention was reported. Six patients (12%) required rehospitalization, including heart failure (n=2), minor procedural side effects (n=2), and valve thrombosis (n=2; both resolved with anticoagulation). An additional valve thrombosis was associated with no significant clinical sequelae. From baseline to 1 year, all subjects with available data had none/trace or mild (grade 1+) mitral regurgitation and the New York Heart Association class improved in 87.2% (41/47) of patients. CONCLUSIONS: Mitral valve-in-valve with a balloon-expandable valve via transseptal approach in intermediate-risk patients was associated with improved symptoms and quality of life, adequate transcatheter valve performance, and no mortality or stroke at 1-year follow-up. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03193801.


Asunto(s)
Bioprótesis , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Diseño de Prótesis , Falla de Prótesis , Recuperación de la Función , Humanos , Femenino , Masculino , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Anciano , Estudios Prospectivos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Factores de Tiempo , Resultado del Tratamiento , Factores de Riesgo , Persona de Mediana Edad , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Medición de Riesgo , Anciano de 80 o más Años , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/mortalidad , Estados Unidos , Estenosis de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/fisiopatología , Estenosis de la Válvula Mitral/mortalidad , Estenosis de la Válvula Mitral/diagnóstico por imagen , Hemodinámica , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad
19.
Ann Cardiothorac Surg ; 13(3): 211-223, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38841078

RESUMEN

Prosthesis-patient mismatch (PPM) occurs when the effective orifice area (EOA) of a normally functioning prosthetic valve is too small in relation to the patient's body size. The effect of PPM on outcomes and valve durability have gained credibility, making this an important possibly preventable risk factor. Transcatheter aortic valve replacement (TAVR) generally has a lower incidence of PPM than surgical aortic valve replacement (SAVR). Current surgical literature and randomized trials show an association between severe PPM and mortality in patients with SAVR but there is less evidence for an association with TAVR. Differences in the incidence of PPM may be related to the methods and cutoffs for measuring mismatch. This review will discuss the current state of field and propose standardization of measurement methods which may more accurately risk stratify patients.

20.
JACC Adv ; 3(3): 100853, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38938841

RESUMEN

Background: Low stroke volume index <35 ml/m2 despite preserved ejection fraction (paradoxical low flow [PLF]) is associated with adverse outcomes in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). However, whether the risk associated with PLF is similar in both sexes is unknown. Objectives: The purpose of this study was to analyze the risk associated with PLF in severe aortic stenosis for men and women randomized to TAVR or SAVR. Methods: Patients with ejection fraction ≥50% from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were stratified by sex and treatment arm. The impact of PLF on the 2-year occurrence of the composite of death or heart failure hospitalization (primary endpoint) and of all-cause mortality alone (secondary endpoint) was analyzed. Analysis of variance was used to assess baseline differences between groups. Multivariate Cox regression analysis was used to identify predictors of the endpoint. Results: Out of 2,242 patients, PLF was present in 390 men and 239 women (30% vs 26%, P = 0.06). PLF was associated with a higher rate of NYHA functional class III to IV dyspnea (60% vs 54%, P < 0.001) and a higher prevalence of atrial fibrillation (39% vs 24%, P < 0.001). PLF was a significant predictor of the primary endpoint among women undergoing SAVR in multivariate analysis (adjusted HR: 2.25 [95% CI: 1.14-4.43], P = 0.02) but was not associated with a worse outcome in any of the other groups (all P > 0.05). Conclusions: In women with PLF, TAVR may improve outcomes compared to SAVR. PLF appears to have less impact on outcomes in men.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA