Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 98
Filtrar
1.
Eur J Orthod ; 46(6)2024 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-39364771

RESUMEN

BACKGROUND/OBJECTIVES: It is unclear whether palatal canine impaction is related to genetic or local/environmental factors. If a genetic origin is assumed, then it could be expected that palatal canine impaction is associated with overall craniofacial development. Within this context, the aim of this study was to evaluate the craniofacial morphology of individuals with palatal canine impaction and compare it to a matched group of normal controls. MATERIALS/METHODS: The sample for this investigation comprised 404 individuals (232 females and 172 males). Half of these individuals presented with unilateral or bilateral palatal canine impaction confirmed clinically and radiographically. The other half were matched for sex and age with the first half and comprised individuals without tooth impaction, apart from third molars. The shape of the craniofacial structures was outlined on calibrated cephalometric images through 15 curves and 127 landmarks (11 fixed and 116 semi-landmarks). Shape configurations were superimposed using Procrustes Superimposition and the resulting shape coordinates were reduced into principal components for all subsequent analyses. The effect of palatal canine impaction on craniofacial shape was assessed with regression models, separately in females and males. All statistical tests were performed assuming a type-1 error of 5%. RESULTS: Individuals with palatally impacted canines appear to have a less convex face, a more brachyfacial skeletal pattern, and a sagittally extended premaxilla. In females effect sizes ranged between η2 = 0.136-0.397 (P < 0.05) and in males between η2 = 0.125-0.396 (P < 0.05, apart from the entire craniofacial configuration: P = 0.259). LIMITATIONS: Palatal canine impaction was not confirmed through cone beam computer tomography images in all patients, however, in those cases, the treatment history confirmed the diagnosis. CONCLUSIONS/IMPLICATIONS: Palatal canine impaction is related to a distinct craniofacial shape in females and males. These findings allow for speculation that palatal canine impaction is affected by genetic pathways involved in overall craniofacial development.


Asunto(s)
Cefalometría , Diente Canino , Diente Impactado , Humanos , Masculino , Femenino , Diente Canino/diagnóstico por imagen , Diente Impactado/diagnóstico por imagen , Diente Impactado/patología , Cefalometría/métodos , Adolescente , Adulto Joven , Adulto , Niño , Estudios de Casos y Controles , Puntos Anatómicos de Referencia , Maxilar/diagnóstico por imagen , Cráneo/diagnóstico por imagen , Cráneo/anatomía & histología , Cráneo/patología
2.
Sci Rep ; 14(1): 8546, 2024 04 12.
Artículo en Inglés | MEDLINE | ID: mdl-38609399

RESUMEN

In cases of osseous defects, knowledge of the anatomy, and its age and sex-related variations, is essential for reconstruction of normal morphology. Here, we aimed at creating a 3D atlas of the human mandible in an adult sample using dense landmarking and geometric morphometrics. We segmented 50 male and 50 female mandibular surfaces from CBCT images (age range: 18.9-73.7 years). Nine fixed landmarks and 510 sliding semilandmarks were digitized on the mandibular surface, and then slid by minimizing bending energy against the average shape. Principal component analysis extracted the main patterns of shape variation. Sexes were compared with permutation tests and allometry was assessed by regressing on the log of the centroid size. Almost 49 percent of shape variation was described by the first three principal components. Shape variation was related to width, height and length proportions, variation of the angle between ramus and corpus, height of the coronoid process and inclination of the symphysis. Significant sex differences were detected, both in size and shape. Males were larger than females, had a higher ramus, more pronounced gonial angle, larger inter-gonial width, and more distinct antegonial notch. Accuracy of sexing based on the first two principal components in form space was 91 percent. The degree of edentulism was weakly related to mandibular shape. Age effects were not significant. The resulting atlas provides a dense description of mandibular form that can be used clinically as a guide for planning surgical reconstruction.


Asunto(s)
Mandíbula , Caracteres Sexuales , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Epífisis , Articulaciones , Mandíbula/anatomía & histología , Mandíbula/diagnóstico por imagen , Polímeros
3.
Sci Rep ; 14(1): 5840, 2024 03 10.
Artículo en Inglés | MEDLINE | ID: mdl-38462644

RESUMEN

Non-syndromic permanent tooth agenesis affects a significant proportion of the population, especially if third molars are considered. Although tooth agenesis has been linked to a smaller craniofacial size, reduced facial convexity and a shorter skeletal face, the occlusal characteristics of individuals with tooth agenesis remain largely unexplored. Therefore, this study investigated potential associations between tooth agenesis and metric occlusal traits in 806 individuals (491 with 4.1 missing teeth per subject, including third molars, and 315 without any tooth agenesis). Dentoskeletal morphology was defined through anatomical landmarks on pre-treatment cephalometric radiographs. Multivariate regression models, adjusted for sex and age, showed that tooth agenesis was significantly associated with a reduced overjet, an increased interincisal angle, and shorter upper and lower dental arch lengths, but not with overbite. Moreover, apart from reduced tooth length and dentoalveolar effects, as the number of missing teeth increased the upper front teeth were progressively retruded according to the craniofacial complex and to the face. Thus, tooth agenesis has a substantial influence on dental and occlusal characteristics, as well as on the sagittal position and inclination of anterior teeth. These findings emphasize the necessity for personalized, multidisciplinary approaches in individuals with multiple agenesis to successfully meet treatment goals.


Asunto(s)
Anodoncia , Maloclusión Clase II de Angle , Maloclusión , Sobremordida , Diente , Humanos , Diente/diagnóstico por imagen , Dentición Permanente , Maloclusión Clase II de Angle/terapia , Anodoncia/diagnóstico por imagen , Cefalometría , Tercer Molar
4.
Clin Oral Investig ; 28(2): 155, 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38366215

RESUMEN

OBJECTIVES: This study quantified the long-term occlusal wear in the natural posterior teeth and the associations per tooth type within the dentition. METHODS: The sample included 70 orthodontically treated subjects (52 females and 18 males; median age, 14.3 years), followed for a 12.7-year period. They were consecutively selected with no tooth wear-related criteria. Post-treatment (T1) and follow-up dental casts (T2) were scanned and superimposed through three-dimensional methods. Occlusal wear volume of posterior teeth and tooth wear patterns were investigated through non-parametric statistics and analysis of covariance. RESULTS: There were no significant differences between contralateral teeth. The average occlusal wear per posterior tooth was 2.3 mm3, with 65.2% of teeth showing values greater than 1 mm3. Males, mandibular teeth, and first molars exhibited slightly greater wear levels than females (median, 2.57 and 2.21 mm3, respectively; p = 0.005), maxillary teeth, and first or second premolars, respectively. In all first premolars and in the mandibular second premolars, the buccal cusps were primarily affected with no other distinct patterns. There were weak to moderate correlations between tooth types, apart from certain strong correlations detected in males. CONCLUSIONS: Posterior tooth wear was highly prevalent after a 13-year period starting at the onset of permanent dentition. The detected patterns are in accordance with the concept of canine guidance occlusion that is transforming into group synergy through function. CLINICAL RELEVANCE: The widespread tooth wear occurrence and the high intra- and inter-individual variability underline the need for individual patient monitoring to identify high-risk patients at early stages.


Asunto(s)
Atrición Dental , Desgaste de los Dientes , Masculino , Femenino , Humanos , Adolescente , Dentición Permanente , Diente Molar , Diente Premolar
5.
Eur J Orthod ; 46(1)2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37870430

RESUMEN

OBJECTIVE: To investigate the association between the number of third molars and craniofacial shape. SUBJECTS AND METHODS: The study sample comprised 470 individuals (194 males and 276 females), out of whom 310 (124 males, mean age: 14.6 years and 186 females, mean age: 14.1 years) had a full permanent dentition including third molars and 160 (70 males, mean age: 13.7 years and 90 females, mean age: 13.9 years) had at least one missing third molar. Pre-orthodontic treatment cephalometric images were digitized using 127 landmarks to describe the shape of the entire craniofacial configuration, the cranial base, the maxilla, and the mandible. The shapes of the various configurations were described by principal components (PCs) of shape. The effect of third molar agenesis on craniofacial shape was evaluated with multivariate regression models, considering shape PCs as the dependent variables, and age and sex as predictors. RESULTS: There was a strong association between third molar agenesis and the shape of all craniofacial configurations in both sexes. Individuals with missing third molars presented a less convex craniofacial configuration, a shorter anterior facial height and a more retrusive maxilla and mandible. In cases with third molar agenesis only in one jaw, shape differences were also evident in the opposing jaw. LIMITATIONS: Interpretation of study outcomes should take into consideration the two-dimensional data and the analysis of only white-European subjects. CONCLUSIONS: There is a strong association between third molar formation and craniofacial shape. The effect is rather generalized than local and is potentially linked to an ongoing evolutionary mechanism that leads to smaller and fewer teeth, as well as smaller craniofacial configurations, in modern humans.


Asunto(s)
Anodoncia , Tercer Molar , Masculino , Femenino , Humanos , Adolescente , Tercer Molar/anomalías , Dentición Permanente , Mandíbula , Maxilar
6.
Eur J Orthod ; 46(1)2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38128567

RESUMEN

OBJECTIVES: The purpose of this study was to measure the effectiveness of the cervical headgear for distalizing first permanent maxillary molars in relation to hours of use. METHODS: This was a one-centre, prospective, clinical study conducted at the Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece. Participants (N = 26; 17 females, 9 males) were patients with no history of orthodontic treatment, no syndromes or clefts, and Angle's Class II malocclusion, where the treatment plan included a cervical headgear. They were instructed to wear the appliance for at least 12 h per day. A TheraMon® microsensor was embedded in the headgear's strap to objectively measure wear-time. To measure tooth movement, pre- and post-treatment digital models were superimposed, using the palate as a reference area; translation and rotation were measured along three axes. Superimposition and movement measurements were made with the Viewbox 4 software. RESULTS: Average treatment time and headgear wear were 130 days and 55 days, respectively, i.e. 10.1 h/day. During this period, distal movement averaged 1.75 mm with high variability (min 0.2 mm, max 4.5 mm). Distal tipping and rotation had an average of approximately 5 °C. Cumulative headgear wear was significantly correlated with distal movement (r2 = 0.32, P < .002), distal tipping (r2 = 0.27, P < .01), and distal rotation around the long axis of the tooth (r2 = 0.20, P < .05). CONCLUSION: Compliance is critical for having a successful clinical outcome. Distalization of the molar with a cervical headgear is correlated with the cumulative hours of appliance use, with hours per day being a weaker predictor.


Asunto(s)
Maloclusión Clase II de Angle , Aparatos Ortodóncicos , Masculino , Femenino , Humanos , Estudios Prospectivos , Cefalometría , Maloclusión Clase II de Angle/terapia , Técnicas de Movimiento Dental , Maxilar , Diente Molar , Cooperación del Paciente , Diseño de Aparato Ortodóncico , Aparatos de Tracción Extraoral
7.
Sci Rep ; 13(1): 21002, 2023 11 28.
Artículo en Inglés | MEDLINE | ID: mdl-38017262

RESUMEN

The accuracy of three-dimensional (3D) facial skeletal surface models derived from radiographic volumes has not been extensively investigated yet. For this, ten human dry skulls were scanned with two Cone Beam Computed Tomography (CBCT) units, a CT unit, and a highly accurate optical surface scanner that provided the true reference models. Water-filled head shells were used for soft tissue simulation during radiographic imaging. The 3D surface models that were repeatedly segmented from the radiographic volumes through a single-threshold approach were used for reproducibility testing. Additionally, they were compared to the true reference model for trueness measurement. Comparisons were performed through 3D surface approximation techniques, using an iterative closest point algorithm. Differences between surface models were assessed through the calculation of mean absolute distances (MAD) between corresponding surfaces and through visual inspection of facial surface colour-coded distance maps. There was very high reproducibility (approximately 0.07 mm) and trueness (0.12 mm on average, with deviations extending locally to 0.5 mm), and no difference between radiographic scanners or settings. The present findings establish the validity of lower radiation CBCT imaging protocols at a similar level to the conventional CT images, when 3D surface models are required for the assessment of facial morphology.


Asunto(s)
Tomografía Computarizada de Haz Cónico Espiral , Humanos , Reproducibilidad de los Resultados , Imagenología Tridimensional/métodos , Cráneo/diagnóstico por imagen , Cara/diagnóstico por imagen
8.
PLoS One ; 18(11): e0294528, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38011159

RESUMEN

Symmetry is a fundamental biological concept in all living organisms. It is related to a variety of physical and social traits ranging from genetic background integrity and developmental stability to the perception of physical appearance. Within this context, the study of human facial asymmetry carries a unique significance. Here, we validated an efficient method to assess 3D facial surface symmetry by best-fit approximating the original surface to its mirrored one. Following this step, the midsagittal plane of the face was automatically defined at the midpoints of the contralateral corresponding vertices of the superimposed models and colour coded distance maps were constructed. The method was tested by two operators using facial models of different surface size. The results show that the midsagittal plane definition was highly reproducible (maximum error < 0.1 mm or°) and remained robust for different extents of the facial surface model. The symmetry assessments were valid (differences between corresponding bilateral measurement areas < 0.1 mm), highly reproducible (error < 0.01 mm), and were modified by the extent of the initial surface model. The present landmark-free, automated method to assess facial asymmetry and define the midsagittal plane of the face is accurate, objective, easily applicable, comprehensible and cost effective.


Asunto(s)
Asimetría Facial , Imagenología Tridimensional , Humanos , Imagenología Tridimensional/métodos , Cefalometría/métodos , Cabeza , Sesgo
9.
Korean J Orthod ; 53(4): 254-263, 2023 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-37497582

RESUMEN

Objective: The evidence on the accuracy of bite registration using intraoral scanners is sparse. This study aimed to develop a new method for evaluating bite registration accuracy using intraoral scanners. Methods: Two different types of models were used; 10 stone models and 10 with acrylic resin teeth. A triangular frame with cylindrical posts at each apex (one anterior and two posteriors) was digitally designed and manufactured using three-dimensional (3D) printing. Such a structure was fitted in the lingual space of each maxillary and mandibular model so that, in occlusion, the posts would contact their opposing counterparts, enforcing a small interocclusal gap between the two arches. This ensured no tooth interference and full contact between opposing posts. Bite registration accuracy was evaluated by measuring the distance between opposing posts, with small values indicating high-accuracy. Three intraoral scanners were used: Medit i500, Primescan, and Trios 4. Viewbox software was used to measure the distance between opposing posts and compute roll and pitch. Results: The average maximum error in interocclusal registration exceeded 50 µm. Roll and pitch orientation errors ranged above 0.1 degrees, implying an additional interocclusal error of around 40 µm or more. The models with acrylic teeth exhibited higher errors. Conclusions: A method that avoids the need for reference hardware and the imprecision of locating reference points on tooth surfaces, and offers simplicity in the assessment of bite registration with an intraoral scanner, was developed. These results suggest that intraoral scanners may exhibit clinically significant errors in reproducing the interocclusal relationships.

10.
Korean J Orthod ; 53(3): 185-193, 2023 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-37113038

RESUMEN

Objective: The growth and development of the mandible strongly depend on modeling changes occurring at its ramus. Here, we investigated covariance patterns between the morphology of the ramus and the rest of the face. Methods: Lateral cephalograms of 159 adults (55 males and 104 females) with no history of orthodontic treatment were collected. Geometric morphometrics with sliding semi-landmarks was used. The covariance between the ramus and face was investigated using a two-block partial least squares analysis (PLS). Sexual dimorphism and allometry were also assessed. Results: Differences in the divergence of the face and anteroposterior relationship of the jaws accounted for 24.1% and 21.6% of shape variation in the sample, respectively. Shape variation was greater in the sagittal plane for males than for females (30.7% vs. 17.4%), whereas variation in the vertical plane was similar for both sexes (23.7% for males and 25.4% for females). Size-related allometric differences between the sexes accounted for the shape variation to a maximum of 6% regarding the face. Regarding the covariation between the shapes of the ramus and the rest of the face, wider and shorter rami were associated with a decreased lower anterior facial height as well as a prognathic mandible and maxilla (PLS 1, 45.5% of the covariance). Additionally, a more posteriorly inclined ramus in the lower region was correlated with a Class II pattern and flat mandibular plane. Conclusions: The width, height, and inclination of the ramus were correlated with facial shape changes in the vertical and sagittal planes.

11.
Dent J (Basel) ; 11(1)2023 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-36661564

RESUMEN

(1) Background: New intraoral (IOS) and laboratory scanners appear in the market and their trueness and precision have not been compared. (2) Methods: Seven IOS and two laboratory scanners were used to scan a mandibular edentulous model with four parallel internal hexagon implant analogues and PEEK scan bodies. Digital models in Standard Tessellation Language (STL) were created. The master model with the scan bodies was scanned (×10) with a computerized numerical control 3D Coordinate Measuring Machine (CMM). The short (distances of adjacent scan posts) and long distances (distances of the scan posts with non-adjacent sites in the arch) among the centroids of the four analogues were calculated using CMM special software. Trueness (comparisons with the master model) and precision (intragroup comparisons) were statistically compared with ANOVA, chi-square and Tukey tests. (3) Results: Laboratory scanners had the best trueness and precision compared to all IOSs for long distances. Only iTero (Align Technologies Inc., Milpitas, CA, USA) had comparable trueness with one laboratory scanner in short and long distances. For short distances, CS3600 (Carestream Health, Inc., Rochester, NY, USA), Omnicam, Primescan (Sirona Dental Sys-tems GmbH, Bens-heim, Germany) and TRIOS 4 (3Shape A/S, Copen-hagen, Denmark) had similar trueness to one laboratory scanner. From those, only Omnicam and Primescan had similar precision as the same laboratory scanner. Most IOSs seem to work better for smaller distances and are less precise in cross-arch distances. (4) Conclusions: The laboratory scanners showed significantly higher trueness and precision than all IOSs tested for the long-distance group; for the short distance, some IOSs were not different in trueness and precision than the laboratory scanners.

12.
Clin Oral Investig ; 27(4): 1697-1705, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36424472

RESUMEN

OBJECTIVES: To develop and validate a method for accurate quantitative assessment of gingival recessions based on superimposition of serial 3D digital models. MATERIALS AND METHODS: Gingival recessions of mild (0.5-2 mm) and increased (3-7 mm) severity were simulated on stone casts and surface models were created. The outlines of the gingival margins of the mild (A) and severe recessions (B) were compared to the original gingival margins following 3D best fit superimposition through a gold standard technique (GS), which used intact adjacent structures, and the tested method (CC), which used single tooth crowns at the position of recessions, as superimposition reference. The primary outcome was the distance between the most apical point of each corresponding gingival margin along the respective tooth long axis. RESULTS: For mild recessions, the median difference of the test methods (CC_A) from the reference method (GS_A) was 0.008 mm (IQR: 0.093; range: - 0.143, 0.147). For severe recessions, the median difference of the test method (CC_B) from the reference method (GS_B) was 0.009 mm (IQR: 0.091; range: - 0.170, 0.198). The proposed method (CC) showed very high intra- and inter-operator reproducibility (median: 0.025 and 0.033 mm, respectively). CONCLUSIONS: The suggested method offers highly accurate monitoring of gingival margin changes and diagnosis of gingival recessions using 3D digital dental models. The method is applicable irrespective of changes in tooth position or form, allowing for assessments over any time span. CLINICAL RELEVANCE: The accurate detection and visualization of gingival margin changes in 3D will enhance diagnosis and patient-doctor communication.


Asunto(s)
Recesión Gingival , Diente , Humanos , Reproducibilidad de los Resultados , Modelos Dentales , Encía , Resultado del Tratamiento
13.
Sci Rep ; 12(1): 22549, 2022 12 29.
Artículo en Inglés | MEDLINE | ID: mdl-36581665

RESUMEN

In radiology research soft tissues are often simulated on bone specimens using liquid materials such as water, or gel-like materials, such as ballistic gel. This study aimed to test the effect of hydration on the anatomical form of dry craniofacial bone specimens. Sixteen human dry skulls and 16 mandibles were scanned with an industrial scanner in dry conditions and after water embedding. Ten skulls were also embedded for different time periods (5 or 15 min). The subsequent 3D surface models were best-fit superimposed and compared by calculating mean absolute distances between them at various measurement areas. There was a significant, primarily enlargement effect of hydration on the anatomical form of dry skeletal specimens as detected after water embedding for a short time period. The effect was smaller in dry skulls (median 0.20 mm, IQR 0.17 mm) and larger in mandibles (median 0.56 mm, IQR 0.57 mm). The effect of different water embedding times was negligible. Based on the present findings, we suggest to shortly hydrate the skeletal specimens prior to reference model acquisition so that they are comparable to hydrated specimens when liquid materials are used as soft-tissue simulants for various radiologic research purposes.


Asunto(s)
Mandíbula , Cráneo , Humanos , Cráneo/diagnóstico por imagen , Mandíbula/diagnóstico por imagen , Agua
14.
Sci Rep ; 12(1): 21749, 2022 12 16.
Artículo en Inglés | MEDLINE | ID: mdl-36526713

RESUMEN

Palatal rugae constitute significant morphological landmarks, with wide clinical applications in forensics, insertion of mini-screws, and superimposition. Their morphology has been studied mainly with indices relevant to their qualitative characteristics. The present paper aims at presenting a new quantitative method to evaluate their complexity, by means of box-counting fractal dimension analysis, and to investigate its inter- and intra-rater reliability. Twenty maxillary plaster models were scanned for the needs of this study. A sequence of steps, including cropping of the mesh, ball pivoting, distance mapping and fractal dimension analysis, performed with Viewbox 4 software, was followed. Box-counting fractal dimensions were calculated as a measure of rugae's complexity. Inter- and intra-rater reliability were investigated, using Bland-Altman analysis. Fractal dimensions ranged from 1.274 to 1.491 (average: 1.412). Bland-Altman analysis of inter- and intra-examiner reliability demonstrated that the 95% limits of agreement ranged from - 0.012 to 0.011 and from - 0.004 to 0.004, respectively. The method is reliable and can be applied in research and forensics. It offers comprehensive evaluation of the rugae's complexity and a complete set of information about their outlines and height profiles, with minimum user intervention.


Asunto(s)
Fractales , Maxilar , Reproducibilidad de los Resultados , Programas Informáticos
15.
Diagnostics (Basel) ; 12(9)2022 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-36140652

RESUMEN

Three-dimensional surface scans of skeletal structures have various clinical and research applications in medicine, anthropology, and other relevant fields. The aim of this study was to test the precision of a widely used hand-held surface scanner and the associated software's 3D model generation-error in both dry and wet skeletal surfaces. Ten human dry skulls and ten mandibles (dry and wet conditions) were scanned twice with an industrial scanner (Artec Space Spider) by one operator. Following a best-fit superimposition of corresponding surface model pairs, the mean absolute distance (MAD) between them was calculated on ten anatomical regions on the skulls and six on the mandibles. The software's 3D model generation process was repeated for the same scan of four dry skulls and four mandibles (wet and dry conditions), and the results were compared in a similar manner. The median scanner precision was 31 µm for the skulls and 25 µm for the mandibles in dry conditions, whereas in wet conditions it was slightly lower at 40 µm for the mandibles. The 3D model generation-error was negligible (range: 5-10 µm). The Artec Space Spider scanner exhibits very high precision in the scanning of dry and wet skeletal surfaces.

16.
Dent J (Basel) ; 10(7)2022 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-35877397

RESUMEN

The purpose of the present study was to examine the impact of scanning strategy on trueness and precision of the impression acquired from an intraoral scanner. Fifteen complete-arch, mandibular, post-orthodontic treatment casts were scanned with a laboratory scanner (Identica SE 3D, Medit) as the gold standard, and with an intraoral scanner (i500 Medit) following three different paths of the scanning head over the arch (scanning strategies A, B, and C). The hand scans were performed twice by one examiner and repeated by a second examiner, resulting in 180 triangular mesh surfaces (digital casts). The meshes were superimposed on the gold standards using the Viewbox 4 software. The closest distances between the meshes were computed and trueness and precision were evaluated using a General Linear Model. An interaction was found among the examiner and strategy. The accuracy of complete-arch impressions was affected by the scanning strategy; the manufacturer's recommended strategy (A) was statistically significantly better (p < 0.05) than B and C, which were similar. An average accuracy below 50 µm, which is clinically acceptable in most orthodontic procedures, was achieved with all the examined scanning strategies.

17.
Biology (Basel) ; 11(5)2022 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-35625447

RESUMEN

The reproducibility of facial expressions has been previously explored, however, there is no detailed information regarding the reproducibility of lip morphology forming a social smile. In this study, we recruited 93 young adults, aged 21−35 years old, who agreed to participate in two consecutive study visits four weeks apart. On each visit, they were asked to perform a social smile, which was captured on a 3D facial image acquired using the 3dMD camera system. Assessments of self-perceived smile attractiveness were also performed using a VAS scale. Lip morphology, including smile shape, was described using 62 landmarks and semi-landmarks. A Procrustes superimposition of each set of smiling configurations (first and second visit) was performed and the Euclidean distance between each landmark set was calculated. A linear regression model was used to test the association between smile consistency and self-perceived smile attractiveness. The results show that the average landmark distance between sessions did not exceed 1.5 mm, indicating high repeatability, and that females presented approximately 15% higher smile consistecy than males (p < 0.05). There was no statistically significant association between smile consistency and self-perceived smile attractiveness (η2 = 0.015; p = 0.252), when controlling for the effect of sex and age.

18.
Biology (Basel) ; 11(4)2022 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-35453743

RESUMEN

One of the most common dental anomalies in humans is the congenital absence of teeth, referred to as tooth agenesis. The association of tooth agenesis to craniofacial morphology has been previously investigated but remains unclear. We investigated this association by applying geometric morphometric methods in a large sample of modern humans. In line with previous studies, we report here that a reduced teeth number is linked to a less convex profile, as well as to a shorter face. The effects were similar for males and females; they increased as the severity of the tooth agenesis increased and remained unaltered by the inclusion of third molars and of allometry in the analysis. Furthermore, in cases with tooth agenesis only in the maxilla, there was no detectable effect in mandibular shape, whereas maxillary shape was affected independently of the location of missing teeth. The robustness of the present sample along with the shape analysis and the statistical approach applied, allowed for thorough testing of various contributing factors regarding the presence but also the magnitude of effects. The present findings suggest a relationship between number of teeth and overall craniofacial development and have evolutionary implications.

19.
Vet Sci ; 9(3)2022 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-35324872

RESUMEN

Mandibular protrusion and its treatment is challenging for the orthodontist. The aim of the present research was to identify macroscopic changes in the mandible, based on three-dimensional Cone Beam Computed Tomography analysis. Seventy-two male Wistar rats were divided into two equal groups, experimental (group A) and control (group B). Each consisted of three equal subgroups of 12 rats (A1, A2, A3, B1, B2, B3). Full-cast orthodontic intraoral devices were attached to the maxillary incisors of the experimental animals, and effected functional posterior mandibular displacement. Throughout the experimental period, all animals were fed with mashed food. Animals were sacrificed at 30 days (A1, B1), 60 days (A2, B2) and 90 days (A3, B3). At the 60th day of the experiment, the orthodontic devices were removed from the remaining experimental subgroup A3. Measurements revealed significant differences in the anteroposterior dimensions between experimental and control subgroups. However, the observed changes in the vertical dimensions, Condylion/Go'-Menton and the Intercondylar distance proved insignificant. Posterior mandibular displacement of the mandible in growing rats affects the morphology of the mandible and culminates in the development of a smaller mandible at a grown age.

20.
J Musculoskelet Neuronal Interact ; 22(1): 93-101, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-35234164

RESUMEN

OBJECTIVES: To investigate in growing rats the effect of intrauterine growth restriction (IUGR) on the bone mineral density of the mandible and tibia, as well as the quality of the mandibular and condylar bone. METHODS: Twelve male rats were born IUGR by mothers sustaining 50% food restriction during pregnancy. Twelve control male rats were born by mothers fed ad libitum. Dual-energy X-ray absorptiometry (DEXA) of the tibia, proximal tibial metaphysis and the mandible, biochemical markers, histology and histomorphometrical analysis on the mandibular and subchondral bone of the condyle were performed. RESULTS: IUGR significantly affected bone mineral density (BMD) of both tibial and mandibular bones. IUGR rats had significantly lower osteocalcin values (p=0.021) and phosphorus (p=0.028), but not 25-OH vitamin D (p=0.352). Bone area percentage in the mandible was significantly lower (51.21±5.54) in IUGR compared to controls (66.00±15.49), and for subchondral bone of the condyle for IUGR (47.01±6.82) compared to controls (68.27±13.37). IUGR had a significant reduction in the fibrous layer, but not the proliferating layer, with the hypertrophic layer significantly increased. CONCLUSION: Maternal restricted nutrition during gestation can affect BMD of the mandible and the tibia of the offspring animals.


Asunto(s)
Densidad Ósea , Retardo del Crecimiento Fetal , Absorciometría de Fotón , Animales , Femenino , Humanos , Masculino , Mandíbula/diagnóstico por imagen , Embarazo , Ratas , Tibia/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA