Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Dent Mater ; 39(10): 946-956, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37648563

RESUMEN

OBJECTIVES: To evaluate the influence of a glutaraldehyde-based desensitizer (GL) on postoperative sensitivity (POS) in posterior bulk-fill resin composite restorations using an adhesive applied in the self-etch (SE) and etch-and-rinse (ER) strategies; and to assess the clinical performance of the restorations. METHODS: Posterior resin composite restorations (n = 228) at least 3 mm deep were inserted in 57 subjects using a split-mouth design. The adhesive was applied with/without prior application of a GL. A resin composite was used for all restorations. Spontaneous POS (risk and intensity), as well as POS caused by stimulation with an air blast and assess the response to horizontal and vertical percussion was assessed using two scales in the baseline and after 7, 14, and 30 days. In addition, some parameters were evaluated using FDI criteria up to 24 months of clinical service. RESULTS: No significant POS was observed (p > 0.05). A higher absolute risk and intensity of spontaneous POS was observed within 7 days (35.1%), without statistically significant differences among groups. At 24 months 5 restorations were considered clinically unsatisfactory, and 73 restorations showed minor discrepancies in adaptation, with no significant differences between groups (p > 0.05). SIGNIFICANCE: A GL agent does not influence POS in posterior restorations with bulk-fill resin composite. It may be considered a dispensable clinical step in the restorative protocol.


Asunto(s)
Resinas Compuestas , Boca , Humanos , Glutaral
2.
J Esthet Restor Dent ; 35(2): 360-367, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-35652434

RESUMEN

OBJECTIVE: Few studies evaluated low concentrations of hydrogen peroxide protocols. The aim of this paper was evaluated two application protocols using 4% hydrogen peroxide in at-home bleaching. MATERIALS AND METHODS: Eighty-six patients with upper canines' shade A2 or darker were randomly allocated under two experimental conditions: two daily applications of 1 h each or a 2-h single application. Color change was evaluated using Vita Classical, Vita Bleachedguide, and digital spectrophotometer weekly and 1 month after the bleaching procedure through one-way ANOVA. The risk and intensity of tooth sensitivity (TS) was assessed through visual and numeric rating scale and measured by Fisher's exact test, Mann-Whitney test and one-way ANOVA respectively. RESULTS: After 3 weeks, the mean difference for the ΔSGU Vita Classical (1.0; 95% CI -0.1 to 2.0), ΔEab (0.7; 95% CI -1.4 to 2.8), ΔE00 (0.1; 95% CI -1.4 to 1.6) and Wi (1.8; 95% CI -1.9 to 5.5) presented no difference (p > 0.08). The relative risk for TS was 0.91 (0.72 to 1.14) without significant difference neither in the risk (p = 0.6) nor in the TS intensity for both pain scales (p > 0.65). CONCLUSIONS: The application protocols evaluated (two daily applications of 1 h each or a 2-h single application) for at-home bleaching with 4% hydrogen peroxide did not showed differences in color change and tooth sensitivity. CLINICAL RELEVANCE: Higher amount of active hydrogen peroxide in two daily applications for at-home bleaching neither accelerate bleaching nor increase the risk or intensity of tooth sensibility.


Asunto(s)
Sensibilidad de la Dentina , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Peróxido de Hidrógeno , Blanqueamiento de Dientes/métodos , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto
3.
J Appl Oral Sci ; 28: e20200121, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33263646

RESUMEN

OBJECTIVE: Dual-cured buildup composites and simplified light-cured adhesive systems are mixed with a chemical activator to prevent the incompatibility between them. To evaluate microshear bond strength (µSBS) and nanoleakage (NL) of three universal adhesives used under buildup composites using different curing modes, at baseline and after 6-months (6m). METHODOLOGY: Dentin specimens of 55 molars were assigned to: Clearfil Universal Bond[CFU], Prime&Bond Elect[PBE] and One Coat 7 Universal[OCU]. All-Bond Universal[ABU] and Adper Scotchbond Multi-Purpose[SMP] were used as controls. CFU, PBE, and OCU were: light-cured [LC], dual-cured using a self-curing activator [DC], and self-cured, using a self-curing activator and waiting for 20 min [SC]. Upon the application of the adhesive, transparent matrices were filled with a dual-cured buildup composite and light cured, then tested in mSBS. For NL, the specimens were submersed in ammoniacal silver nitrate and sectioned to observe under the SEM. Three-way ANOVA and Tukey's test were applied (α=0.05). RESULTS: OCU/LC-PBE/LC resulted in higher mean µSBS than ABU/LC. For SMP/DC higher mean µSBS were obtained than for both CFU/DC and OCU/DC (baseline). No universal adhesive was significantly affected by curing mode or storage time. CFU, PBE, and OCU did not undergo significant changes in any curing mode (p>0.05). NL (baseline) PBE/LC resulted in higher %NL compared to ABU/LC. SMP/DC resulted in higher %NL than CFU/DC-OCU/DC. CFU/LC/DC resulted in lower %NL than CFU/SC. PBE/SC resulted in lower %NL than PBE/DC. OCU/LC/SC showed lower %NL than OCU/DC. OCU showed significant lower %NL than CFU and PBE. All CFU groups, as well as OCU/SC, resulted in increased %NL at 6m when compared with baseline. CONCLUSION: For universal adhesives used in etch-and-rinse mode, self-cured activator and different curing modes did not influence µSBS. However, some interactions were observed for NL, but this influence was material-specific.


Asunto(s)
Recubrimiento Dental Adhesivo , Resinas Compuestas , Cementos Dentales , Dentina , Recubrimientos Dentinarios , Ensayo de Materiales , Cementos de Resina , Resistencia a la Tracción
4.
J. appl. oral sci ; J. appl. oral sci;28: e20200121, 2020. tab, graf
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1143148

RESUMEN

Abstract Dual-cured buildup composites and simplified light-cured adhesive systems are mixed with a chemical activator to prevent the incompatibility between them. Objective: To evaluate microshear bond strength (μSBS) and nanoleakage (NL) of three universal adhesives used under buildup composites using different curing modes, at baseline and after 6-months (6m). Methodology: Dentin specimens of 55 molars were assigned to: Clearfil Universal Bond[CFU], Prime&Bond Elect[PBE] and One Coat 7 Universal[OCU]. All-Bond Universal[ABU] and Adper Scotchbond Multi-Purpose[SMP] were used as controls. CFU, PBE, and OCU were: light-cured [LC], dual-cured using a self-curing activator [DC], and self-cured, using a self-curing activator and waiting for 20 min [SC]. Upon the application of the adhesive, transparent matrices were filled with a dual-cured buildup composite and light cured, then tested in mSBS. For NL, the specimens were submersed in ammoniacal silver nitrate and sectioned to observe under the SEM. Three-way ANOVA and Tukey's test were applied (α=0.05). Results: OCU/LC-PBE/LC resulted in higher mean μSBS than ABU/LC. For SMP/DC higher mean μSBS were obtained than for both CFU/DC and OCU/DC (baseline). No universal adhesive was significantly affected by curing mode or storage time. CFU, PBE, and OCU did not undergo significant changes in any curing mode (p>0.05). NL (baseline) PBE/LC resulted in higher %NL compared to ABU/LC. SMP/DC resulted in higher %NL than CFU/DC-OCU/DC. CFU/LC/DC resulted in lower %NL than CFU/SC. PBE/SC resulted in lower %NL than PBE/DC. OCU/LC/SC showed lower %NL than OCU/DC. OCU showed significant lower %NL than CFU and PBE. All CFU groups, as well as OCU/SC, resulted in increased %NL at 6m when compared with baseline. Conclusion: For universal adhesives used in etch-and-rinse mode, self-cured activator and different curing modes did not influence μSBS. However, some interactions were observed for NL, but this influence was material-specific.


Asunto(s)
Recubrimiento Dental Adhesivo , Resistencia a la Tracción , Ensayo de Materiales , Recubrimientos Dentinarios , Resinas Compuestas , Cementos de Resina , Cementos Dentales , Dentina
5.
Braz Oral Res ; 31(suppl 1): e60, 2017 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-28902240

RESUMEN

We reviewed the literature to evaluate: a) The compliance of randomized clinical trials (RCTs) on bleaching with the CONSORT; and b) the risk of bias of these studies using the Cochrane Collaboration risk of bias tool (CCRT). We searched the Cochrane Library, PubMed and other electronic databases, to find RCTs focused on bleaching (or whitening). The articles were evaluated in compliance with CONSORT in a scale: 0 = no description, 1 = poor description and 2 = adequate description. Descriptive analyses of the number of studies by journal, follow-up period, country and quality assessments were performed with CCRT for assessing risk of bias in RCTs. 185 RCTs were included for assessment. More than 30% of the studies received score 0 or 1. Protocol, flow chart, allocation concealment and sample size were more critical items, as 80% of the studies scored 0. The overall CONSORT score for the included studies was 16.7 ± 5.4 points, which represents 52.2% of the maximum CONSORT score. A significant difference among journal, country and period of time was observed (p < 0.02). Only 7.6% of the studies were judged at "low" risk; 62.1% were classified as "unclear"; and 30.3% as "high" risk of bias. The adherence of RCTs evaluating bleaching materials and techniques to the CONSORT is still low with unclear/high risk of bias.


Asunto(s)
Recubrimiento Dental Adhesivo/normas , Adhesión a Directriz/normas , Guías de Práctica Clínica como Asunto/normas , Ensayos Clínicos Controlados Aleatorios como Asunto/normas , Recubrimiento Dental Adhesivo/métodos , Adhesión a Directriz/estadística & datos numéricos , Humanos , Sesgo de Publicación , Ensayos Clínicos Controlados Aleatorios como Asunto/estadística & datos numéricos , Proyectos de Investigación/normas , Medición de Riesgo , Factores de Riesgo
6.
Braz. oral res. (Online) ; 31(supl.1): e60, Aug. 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-889458

RESUMEN

Abstract We reviewed the literature to evaluate: a) The compliance of randomized clinical trials (RCTs) on bleaching with the CONSORT; and b) the risk of bias of these studies using the Cochrane Collaboration risk of bias tool (CCRT). We searched the Cochrane Library, PubMed and other electronic databases, to find RCTs focused on bleaching (or whitening). The articles were evaluated in compliance with CONSORT in a scale: 0 = no description, 1 = poor description and 2 = adequate description. Descriptive analyses of the number of studies by journal, follow-up period, country and quality assessments were performed with CCRT for assessing risk of bias in RCTs. 185 RCTs were included for assessment. More than 30% of the studies received score 0 or 1. Protocol, flow chart, allocation concealment and sample size were more critical items, as 80% of the studies scored 0. The overall CONSORT score for the included studies was 16.7 ± 5.4 points, which represents 52.2% of the maximum CONSORT score. A significant difference among journal, country and period of time was observed (p < 0.02). Only 7.6% of the studies were judged at "low" risk; 62.1% were classified as "unclear"; and 30.3% as "high" risk of bias. The adherence of RCTs evaluating bleaching materials and techniques to the CONSORT is still low with unclear/high risk of bias.


Asunto(s)
Humanos , Ensayos Clínicos Controlados Aleatorios como Asunto/normas , Recubrimiento Dental Adhesivo/normas , Guías de Práctica Clínica como Asunto/normas , Adhesión a Directriz/normas , Proyectos de Investigación/normas , Ensayos Clínicos Controlados Aleatorios como Asunto/estadística & datos numéricos , Factores de Riesgo , Recubrimiento Dental Adhesivo/métodos , Sesgo de Publicación , Medición de Riesgo , Adhesión a Directriz/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA