Int J Artif Organs ; 32(6): 344-53, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19670186

RESUMEN

OBJECTIVES: A multicentric European Clinical Study is ongoing to evaluate safety and efficacy of a new pulsatile implantable LVAD (BestBeat), smaller and lighter than similar devices, capable of providing synchronous and counterpulsating flow with respect to the LV of end-stage heart failure patients. Preliminary clinical results are reported. METHODS: The new BestBeat LVAD was used, consisting of an implantable pulsatile blood pump, electromechanically driven by a ball screw mechanism, and a wearable electronic controller and power sources. The clinical trial was conducted at 5 european centers. Adult patients affected by CHF in NYHA Class IV despite optimized medical treatment were enrolled. The primary study endpoint was survival at 90 days. Further study endpoints were maintenance of adequate LVAD pump flow and a minimum rate of adverse events during support. RESULTS: As of June 2008, 6 patients received the implant. Cumulative support time was 3.7 years, median support time 176 days. All patients who completed the study survived except for one, who died after 48 days, due to combined infection and cerebrovascular accident. Another two patients died: one from intracranial bleeding 113 days after implant, and one from septic shock after 123 days. Hemodynamic improvement with CI>2.0 l/min/m2 and recovery of end-organ function expressed by consistent improvement of BUN, creatinine and bilirubin were reached in all patients. No device failure was observed. There was no bleeding requiring re-exploration, no hemolysis and only two device-related infections (both in one patient). Neurologic events were reported, the most serious ones occurring in patients with pre-implant respiratory and kidney failure. Three patients were discharged home. Two patients were successfully transplanted, one after 6 months and one after 13 months on device. CONCLUSIONS: Good performance and efficacy of the device were observed; the endpoints of the study were achieved, and its safety was consistent with expectations. The ongoing study will allow further conclusions to be drawn.


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Flujo Pulsátil , Función Ventricular Izquierda , Bilirrubina/sangre , Biomarcadores/sangre , Nitrógeno de la Urea Sanguínea , Creatina/sangre , Diseño de Equipo , Europa (Continente) , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Trasplante de Corazón , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Recuperación de la Función , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA