Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Ophthalmol ; 12(11): 1699-1707, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31741857

RESUMEN

AIM: To study the inhibition effect of TAK-242 on the proliferation of rat eye Tenon's capsule fibroblasts via the toll-like receptor 4 (TLR4) signaling pathway. METHODS: SD rat Tenon's capsule fibroblasts were extracted and cultured, then the cells were divided into normal control group, lipopolysaccharide (LPS) group (10 g/mL LPS) and TAK-242 group (1 µmol/L TAK-242, and 10 µg/mL LPS after 30min). The expressions of TLR4, transforming growth factor-ß1 (TGF-ß1) and interleukin-6 (IL-6) in each group were detected by Western blot and reverse transcriptase-polymerase chain reaction (RT-PCR). Cell proliferation was detected by cell counting kit-8 (CCK-8). RESULTS: Double immunofluorescent labeling in the extracted cells showed negative keratin staining and positive vimentin staining. Western blot showed that the LPS group had the highest expression of TLR4 and TGF-ß1 (P<0.01). Enzyme linked immunosorbent assay (ELISA) also showed that the secretion of IL-6 was the highest in LPS group (P<0.01). But there was no significant difference in TLR4 and TGF-1, as well as IL-6 expressions between the TAK-242 group and the normal control group (P>0.05). RT-PCR showed that the IL-6 mRNA expression in LPS group was the highest in the three groups (P<0.01). CONCLUSION: TAK-242 inhibits the proliferation of LPS-induced Tenon's capsule fibroblasts and the release of inflammatory factors by regulating the TLR4 signaling pathway, providing a new idea for reducing the scarring of the filter passage after glaucoma filtration surgery.

2.
Int Ophthalmol ; 39(8): 1909-1916, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30187195

RESUMEN

PURPOSE: To review and summarize the characteristics of corneal hysteresis (CH) and its relationship with glaucoma. METHODS: A PubMed search was carried out using the terms "corneal hysteresis", "glaucoma", and "biomechanics". Up to March 2018, all studies published in English are included in this review. RESULTS: The value of CH reflects the ability of corneal tissue to absorb and release energy during bidirectional flattening. It is an important biomechanical parameter of the cornea. The CH value of healthy adults is about 11 mmHg. The measurement of CH is reproducible and different. People have different CH values, which are determined by the shape of the individual's cornea. The study found that all types of glaucoma, including primary open angle glaucoma, angle-closure glaucoma, normal tension glaucoma, congenital glaucoma, binocular asymmetrical glaucoma, CH values are lower than normal people, therefore, CH is therefore a good indicator of glaucoma diagnosis and screening. Lower CH values are associated with thinner retinal nerve fiber layer (RNFL), larger linear cup/disk ratio (LCDR) and degree of optic disc defect. A lower CH value can also result in a lower visual field index. CH and the basic intraocular pressure play a synergistic role in the progression of glaucoma. The study found that CH can change with changes in basic intraocular pressure, means CH increases when intraocular pressure decreases, while the CH decreases conversely when intraocular pressure increases. Most clinical case studies have shown a decrease in CH after LASER refractive surgery. CH has its limitations, such as corneal damage or corneal surgery, but in general, CH is a risk factor for glaucoma progression. CONCLUSION: CH is used as a predictor of glaucoma risk and may help to assess the effect of corneal thickness on intraocular pressure. The clinical significance of CH in the diagnosis and efficacy of glaucoma will become more explicit. In the future, CH can also play an important role in the diagnosis and treatment of glaucoma.


Asunto(s)
Córnea/fisiopatología , Glaucoma/fisiopatología , Presión Intraocular/fisiología , Córnea/diagnóstico por imagen , Elasticidad , Glaucoma/diagnóstico , Humanos , Tomografía de Coherencia Óptica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...