1.
Coron Artery Dis ; 34(8): 533-541, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37855304

RESUMEN

BACKGROUND: Although invasive measurement of fractional flow reserve (FFR) is recommended to guide revascularization, its routine use is underutilized. Recently, a novel non-invasive software that can instantaneously produce FFR values from the diagnostic angiograms, derived completely from artificial intelligence (AI) algorithms has been developed. We aim to assess the accuracy and diagnostic performance of AI-FFR in a real-world retrospective study. METHODS: Retrospective, three-center study comparing AI-FFR values with invasive pressure wire-derived FFR obtained in patients undergoing routine diagnostic angiography. The accuracy, sensitivity, and specificity of AI-FFR were analyzed. RESULTS: A total of 304 vessels from 297 patients were included. Mean invasive FFR was 0.86 vs. 0.85 AI-FFR (mean difference: -0.005, P  = 0.159). The diagnostic performance of AI-FFR demonstrated sensitivity of 91%, specificity 95%, positive predictive value 83% and negative predictive value 97%. Overall accuracy was 94% and the area under curve was 0.93 (95% CI 0.88-0.97). 105 lesions fell around the cutoff value (FFR = 0.75-0.85); in this sub-group, AI-FFR demonstrated sensitivity of 95%, and specificity 94%, with an AUC of 0.94 (95% CI 88.2-98.0). AI-FFR calculation time was 37.5 ±â€…7.4 s for each angiographic video. In 89% of cases, the software located the target lesion and in 11%, the operator manually marked the target lesion. CONCLUSION: AI-FFR calculated by an AI-based, angio-derived method, demonstrated excellent diagnostic performance against invasive FFR. AI-FFR calculation was fast with high reproducibility.


Asunto(s)
Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Inteligencia Artificial , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Programas Informáticos , Grabación en Video
2.
JACC Cardiovasc Interv ; 16(1): 94-102, 2023 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-36599593

RESUMEN

BACKGROUND: Coronary artery obstruction is a life-threatening complication of transcatheter aortic valve replacement (TAVR) procedures. Current preventive strategies are suboptimal. OBJECTIVES: The aim of this study was to describe bench testing and clinical experience with a novel device that splits valve leaflets that are at risk for causing coronary obstruction after TAVR, allowing normal coronary flow. METHODS: The ShortCut device was initially tested in vitro and preclinically in a porcine model for functionality and safety. The device was subsequently offered to patients at elevated risk for coronary obstruction. Risk for coronary obstruction was based on computed tomography-based anatomical characteristics. Procedure success was determined as patient survival at 30 days with a functioning new valve, without stroke or coronary obstruction. RESULTS: Following a successful completion of bench testing and preclinical trial, the device was used in 8 patients with failed bioprosthetic valves (median age 81 years; IQR: 72-85 years; 37.5% man) at 2 medical centers. A total of 11 leaflets were split: 5 patients (63.5%) were considered at risk for left main obstruction alone, and 3 patients (37.5%) were at risk for double coronary obstruction. All patients underwent successful TAVR without evidence of coronary obstruction. All patients were discharged from the hospital in good clinical condition, and no adverse neurologic events were noted. Procedure success was 100%. CONCLUSIONS: Evaluation of the first dedicated transcatheter leaflet-splitting device shows that the device can successfully split degenerated bioprosthetic valve leaflets. The procedure was safe and successfully prevented coronary obstruction in patients at risk for this complication following TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Oclusión Coronaria , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Porcinos , Animales , Anciano de 80 o más Años , Prótesis Valvulares Cardíacas/efectos adversos , Factores de Riesgo , Falla de Prótesis , Resultado del Tratamiento , Bioprótesis/efectos adversos , Diseño de Prótesis , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/etiología , Oclusión Coronaria/prevención & control , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones
3.
Infect Dis (Lond) ; 54(11): 828-831, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35796285

RESUMEN

BACKGROUND: Rapid decline in antibody-titres after BNT162b2 mRNA COVID-19 vaccine was reported; thus, a booster dose, and recently a second booster were approved. The study aims to discuss immunogenicity throughout the pandemic, especially after booster dose. METHODS: A prospective study conducted in EMMS-Nazareth hospital, Israel. Anti-SARS-CoV-2 IgG antibody titres were monitored every 5 weeks starting from the vaccine's second dose. To detect symptomatic and asymptomatic infections, nasopharyngeal swabs for COVID-19 PCR were obtained bi-weekly, and on suggestive symptoms. Third dose of the vaccine was suggested for all participants 5 months after the second one. A comparison was made between those who received three doses (booster-group), and those who were infected after having two doses (infection-group) or three doses (booster-infection) group. RESULTS: One-hundred participants were included; 66 finished 14 months of follow-up, out of whom 40 received a third dose, 10 received only two doses-all were infected (mean time for infection 5 ± 12.15 weeks before the designated booster), and 12 received three doses and were infected. The mean titres of these three groups 7 months after the designated booster dose (regardless of receiving it) were 1756 ± 2279; 3483 ± 3016 and 6925 ± 3720 BAU/mL, respectively. The booster group had high titres 7 months after the booster dose, comparable to two months after the second dose (p = .69); The booster-infected group had even higher titres. CONCLUSION: Immunogenicity decline rate after the booster dose is slower than the second dose. Timing of second booster in general population is still to be determined; neutralizing-antibody titres might be helpful.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Vacuna BNT162 , COVID-19/prevención & control , Humanos , Inmunización Secundaria , Estudios Prospectivos
4.
J Cell Mol Med ; 26(11): 3281-3289, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35587574

RESUMEN

Despite intensive efforts, there is no effective remedy for COVID-19. Moreover, vaccination efficacy declines over time and may be compromised against new SARS-CoV-2 lineages. Therefore, there remains an unmet need for simple, accessible, low-cost and effective pharmacological anti-SARS-CoV-2 agents. ArtemiC is a medical product comprising artemisinin, curcumin, frankincense and vitamin C, all of which possess anti-inflammatory and anti-oxidant properties. The present Phase II placebo-controlled, double-blinded, multi-centred, prospective study evaluated the efficacy and safety of ArtemiC in patients with COVID-19. The study included 50 hospitalized symptomatic COVID-19 patients randomized (2:1) to receive ArtemiC or placebo oral spray, twice daily on Days 1 and 2, beside standard care. A physical examination was performed, and vital signs and blood tests were monitored daily until hospital discharge (or Day 15). A PCR assessment of SARS-CoV-2 carriage was performed at screening and on last visit. ArtemiC improved NEWS2 in 91% of patients and shortened durations of abnormal SpO2 levels, oxygen supplementation and fever. No treatment-related adverse events were reported. These findings suggest that ArtemiC curbed deterioration, possibly by limiting cytokine storm of COVID-19, thus bearing great promise for COVID-19 patients, particularly those with comorbidities.


Asunto(s)
Tratamiento Farmacológico de COVID-19 , Humanos , Estudios Prospectivos , SARS-CoV-2 , Resultado del Tratamiento
5.
J Interv Cardiol ; 2022: 1683309, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35414797

RESUMEN

Objectives: This study was planned for evaluating the safety and efficacy of SPAS (stent positioning assistance system) device in first-in-human procedures. Background: SPAS is a novel device that can be used for improved positioning of coronary stents. Methods: Consecutive patients underwent percutaneous coronary intervention (PCI) with the SPAS device. Device-related adverse and serious adverse events were evaluated in addition to a dedicated questionnaire completed by operators immediately after using SPAS. Results: The SPAS device was deployed in 55 PCI procedures, comprising of heavily calcified lesions (33.3%), totally occluded (7.4%), and severely tortuous vessels (7.4%). In these procedures, nonbifurcation and nonostial (53.7%), bifurcation (22.2%), and edge-to-edge (24.1%) stenting techniques were employed. Analysis of the pooled scores for the five satisfaction-related questions gave an average score of 5.6 ± 1.5, with 40 (75.5%) operators providing an average satisfaction grade of >5; the average operator-rated SPAS device accuracy performance scores exceeded 6 out of 7 (on visual analog score). The time spent for positioning the stent with the SPAS device averaged 41 ± 68.0 seconds. The SPAS device was rated as easy to use (6.1 ± 1.6) and reliable (6.1 ± 1.7). No device-related adverse events were reported. Conclusion: This stent positioning device was evaluated in a consecutive cohort of standard and complex PCI procedures. The device was shown to be safe, easy, and precise to use, both in standard and complex cases.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Estudios de Cohortes , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/etiología , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Intervención Coronaria Percutánea/métodos , Stents , Resultado del Tratamiento
7.
Vaccine ; 39(29): 3790-3793, 2021 06 29.
Artículo en Inglés | MEDLINE | ID: mdl-34092429

RESUMEN

BACKGROUND: Clinical trials of the BNT162b2 vaccine, revealed efficacy and safety. We report six cases of myocarditis, which occurred shortly after BNT162b2 vaccination. METHODS: Patients were identified upon presentation to the emergency department with symptoms of chest pain/discomfort. In all study patients, we excluded past and current COVID-19. Routine clinical and laboratory investigations for common etiologies of myocarditis were performed. Laboratory tests also included troponin and C-reactive protein levels. The diagnosis of myocarditis was established after cardiac MRI. FINDINGS: Five patients presented after the second and one after the first dose of the vaccine. All patients were males with a median age of 23 years. Myocarditis was diagnosed in all patients, there was no evidence of COVID-19 infection. Laboratory assays excluded concomitant infection; autoimmune disorder was considered unlikely. All patients responded to the BNT162b2 vaccine. The clinical course was mild in all six patients. INTERPRETATION: Our report of myocarditis after BNT162b2 vaccination may be possibly considered as an adverse reaction following immunization. We believe our information should be interpreted with caution and further surveillance is warranted.


Asunto(s)
COVID-19 , Miocarditis , Adulto , Vacuna BNT162 , Vacunas contra la COVID-19 , Humanos , Masculino , Miocarditis/diagnóstico , ARN Mensajero , SARS-CoV-2 , Vacunación/efectos adversos , Adulto Joven
8.
Rambam Maimonides Med J ; 11(2)2020 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-32374258

RESUMEN

Coronary artery stenting is the treatment of choice for patients requiring coronary angioplasty. We describe the major advancements with this technology. There have been significant developments in the design of stents and adjunctive medical therapies. Newer-generation drug-eluting stents (DES) have almost negligible restenosis rates and, when combined with proper anti-platelet treatment and optimal deployment, a low risk of stent thrombosis. The introduction of newer-generation DES with thinner stent struts, novel durable or biodegradable polymer coatings, and new antiproliferative agents has further improved the safety profile of early-generation DES. In parallel the effectiveness has been kept, with a significant reduction in the risk of target lesion revascularization compared with the early-generation DES. However, to date, the development of completely bioresorbable vascular scaffolds has failed to achieve further clinical benefits and has been associated with increased thrombosis. Newer-generation DES-including both durable polymer as well as biodegradable polymer-have become the standard of care in all patient and lesion subsets, with excellent long-term results.

9.
Harefuah ; 158(10): 691-692, 2019 Oct.
Artículo en Hebreo | MEDLINE | ID: mdl-31576724
10.
Urol Int ; 101(2): 184-189, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30025391

RESUMEN

INTRODUCTION: The aim of our study was to examine the influence of tumor complexity and operative variables on the degree and rate of post-nephron sparing surgery (NSS) acute kidney injury (AKI). METHODS: We retrospectively reviewed the records of 477 patients who underwent NSS for enhancing renal masses in our institution. AKI was determined using the latest definition by AKIN and RIFLE criteria. Serum creatinine was assessed daily starting from day 1 post-surgery and until discharge (usually on postoperative day 3). Estimated glomerular filtration was determined using the Modification of Diet in Renal Disease equation. RESULTS: Overall, 191 patients (40%) developed postoperative AKI, and most of them (88%) were grade 1. Multivariate analysis revealed that the most significant and independent variables associated with AKI were operation time (p = 0.02), ischemia time (p = 0.02), and the use of tissue adhesive for tumor bed closure (p = 0.02). Other important factors (by univariate analysis) were the need for blood transfusion (p = 0.003) and estimated blood loss (p = 0.007). CONCLUSIONS: Operative time, ischemia, and tumor bed closure method are independent predictors of post-NSS AKI. Efforts should be made to limit prolonged ischemia and to reduce viable parenchymal loss. Further studies concerning the functional impact of AKI in these patients will be required.


Asunto(s)
Lesión Renal Aguda/etiología , Neoplasias Renales/cirugía , Nefrectomía/efectos adversos , Tempo Operativo , Tratamientos Conservadores del Órgano/efectos adversos , Daño por Reperfusión/etiología , Técnicas de Sutura/efectos adversos , Adhesivos Tisulares/efectos adversos , Lesión Renal Aguda/sangre , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/fisiopatología , Anciano , Biomarcadores/sangre , Creatinina/sangre , Femenino , Tasa de Filtración Glomerular , Humanos , Neoplasias Renales/patología , Masculino , Persona de Mediana Edad , Nefrectomía/métodos , Tratamientos Conservadores del Órgano/métodos , Daño por Reperfusión/sangre , Daño por Reperfusión/diagnóstico , Daño por Reperfusión/fisiopatología , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento