Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 254
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38984905

RESUMEN

PURPOSE: Patient dissatisfaction rates following total knee arthroplasty (TKA) reported in the literature reach 20%. The optimal coronal alignment is still under debate. The aim of this retrospective study was to compare clinical outcomes in different coronal plane alignment of the knee (CPAK) phenotypes undergoing mechanically aligned (MA) TKA. The hypothesis was that knees with preoperative varus arithmetic hip-knee-ankle angle (aHKA) would achieve inferior clinical outcomes after surgery compared to other aHKA categories. Additionally, another objective was to assess CPAK phenotypes distribution in the study population. METHODS: A retrospective selection was made of 180 patients who underwent MA TKA from April 2021 to December 2022, with a 1-year follow-up. Coronal knee alignment was classified according to the CPAK classification. Clinical outcome evaluations were measured using the Knee Society Score (KSS), Oxford Knee Score (OKS), Short Form Survey 12 and Forgotten Joint Score (FJS). Differences in clinical outcomes were considered statistically significant with a p value <0 .05. RESULTS: Patients with varus aHKA achieved significantly inferior outcomes at final follow-up compared to other aHKA categories in KSS pt. 1 (79.7 ± 17.2 vs. 85.6 ± 14.7; p = 0.028), OKS (39.2 ± 9.2 vs. 42.2 ± 7.2; p = 0.019) and FJS (75.4 ± 31.0 vs. 87.4 ± 22.9; p =0 .003). The most common aHKA category was the varus category (39%). The most common CPAK phenotypes were apex distal Types I (23.9%), II (22.8%) and III (13.3%). CONCLUSION: MA TKA does not yield uniform outcomes across all CPAK phenotypes. Varus aHKA category shows significantly inferior results at final follow-up. The most prevalent CPAK categories are varus aHKA and apex distal JLO, with phenotypes I, II and III being the most common. However, their gender distribution varies significantly. LEVEL OF EVIDENCE: Level IV.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39010716

RESUMEN

PURPOSE: There is a lack of a clear, uniform definition for intraoperatively assessed component loosening of a knee arthroplasty component, complicating the interpretation and interchangeability of results of diagnostic studies using an intraoperative observation as the reference test. The purpose of this study was to establish a consensus among specialised knee revision surgeons regarding the definition of intraoperatively determined loosening of total or unicondylar knee arthroplasty components. METHODS: Utilising the Delphi consensus method, an international panel of highly specialised knee revision surgeons was invited to participate in a three-round process. The initiation of the first round involved the exploration of possible criteria for intraoperatively determined loosening with open questions. The second round focused on rating these criteria importance on a five-point Likert scale. For the third round, criteria that reached consensus were summarised in consecutive definitions for intraoperatively determined loosening and proposed to the panel. Consensus was established when over 70% of participants agreed with a definition for intraoperatively determined loosening. RESULTS: The 34 responding panel members described in total 60 different criteria in the first round of which 34 criteria received consensus in the second round. Summarising these criteria resulted in four different definitions as minimal requirements for intraoperatively determined loosening. Eighty-eight percent of the panel members agreed on defining a component as loose if there is visible fluid motion at the interface observed during specific movements or when gently applying direct force. CONCLUSION: This study successfully established a consensus using a Delphi method among knee revision surgeons on the definition of intraoperatively determined component loosening. By agreeing on the visibility of fluid motion as new definition, this study provides a standardised reference for future diagnostic research. This definition will enhance the interpretability and interchangeability of future diagnostic studies evaluating knee arthroplasty component loosening. LEVEL OF EVIDENCE: Level V.

3.
J Exp Orthop ; 11(3): e12101, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39050592

RESUMEN

Purpose: The purpose of this systematic review was to compare patient satisfaction patient-reported outcomes (PROMs) levels after mechanically aligned (MA) and kinematically aligned (KA) total knee arthroplasty (TKA). Methods: A systematic literature search following PRISMA guidelines was conducted on PubMed, Embase, Medline and Scopus to identify potentially relevant articles for this review, published from the beginning of March 2013 until the end of October 2023. Only articles reporting satisfaction after KA TKA, MA TKA or both were included, which use valid and reliable tools for the evaluation and reporting of satisfaction after TKA. Title, authors, year of publication, study design, level of evidence, follow-up period, patients' demographic data, sample size, type of satisfaction score, postoperative satisfaction score, postoperative alignment, statistical significance, as well as other variables, were extracted for analysis. An Agency for Healthcare Research and Quality's (AHRQ) design-specific scale was used for assessing randomized control trials (RCTs). The nonrandomized control trials were evaluated by using the Joanna Briggs Institute's (JBI) Critical Appraisal Tool. The Newcastle-Ottawa Scale (NOS) was also used to assess cohort studies, while case series were evaluated using the NIH Quality Assessment Tool for Case Series Studies. Results: The initial search identified 316 studies, of which 178 were considered for screening. Eleven studies completely fulfilled the inclusion criteria, including one RCT, five nonrandomized control trials/quasi-experiments, three case series, and two cohort studies. The total number of patients recruited for MA TKA was 1740. Conversely, 497 patients were enrolled for KA TKA. Five studies used the visual analogue scale (VAS) for assessing postoperative patient satisfaction, four used the Knee Society Score (KSS) 2011 version and two Likert-based types of scores. Overall, the highest mean satisfaction score of KSS 2011 was 31.5 ± 6.6 in the MA group, and 29.8 ± 80 in the KA group in four studies. All of them showed high postoperative patient satisfaction rates for both MA and KA TKA, but with no statistically significant difference between them (p > 0.05). Conclusion: Both mechanically aligned total knee arthroplasty, as well as kinematically aligned total knee arthroplasty led to high rates of postoperative patient satisfaction, with no statistically significant differences between them. Level of Evidence: Level III, systematic review.

5.
J Exp Orthop ; 11(3): e12039, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38826500

RESUMEN

Artificial intelligence's (AI) accelerating progress demands rigorous evaluation standards to ensure safe, effective integration into healthcare's high-stakes decisions. As AI increasingly enables prediction, analysis and judgement capabilities relevant to medicine, proper evaluation and interpretation are indispensable. Erroneous AI could endanger patients; thus, developing, validating and deploying medical AI demands adhering to strict, transparent standards centred on safety, ethics and responsible oversight. Core considerations include assessing performance on diverse real-world data, collaborating with domain experts, confirming model reliability and limitations, and advancing interpretability. Thoughtful selection of evaluation metrics suited to the clinical context along with testing on diverse data sets representing different populations improves generalisability. Partnering software engineers, data scientists and medical practitioners ground assessment in real needs. Journals must uphold reporting standards matching AI's societal impacts. With rigorous, holistic evaluation frameworks, AI can progress towards expanding healthcare access and quality. Level of Evidence: Level V.

6.
J Exp Orthop ; 11(3): e12055, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38868128

RESUMEN

Purpose: For primary total knee arthroplasty (TKA), there is an increasing trend towards patient-specific alignment strategies such as kinematic alignment (KA) and inverse kinematic alignment (iKA), which by restoring native joint mechanics may yield higher patient satisfaction rates. Second, the most recent Australian joint registry report describes favourable revision rates for conventionally instrumented TKA compared to technology-assisted techniques such as those using navigation, robotics or custom-cutting blocks. The aim of this technique article is to describe in detail a surgical technique for TKA that: (1) utilises the principles of iKA and (2) uses conventionally instrumented guided resections thereby avoiding the use of navigation, robotics or custom blocks. Methods: A TKA technique is described, whereby inverse kinematic principles are utilised and patient-specific alignment is achieved. Additionally, the patellofemoral compartment of the knee is restored to the native patellofemoral joint line. The sequenced technical note provided may be utilised for cemented or cementless components; cruciate retaining or sacrificing designs and for fixed or rotating platforms. Results: An uncomplicated, robust and reproducible technique for TKA is described. Discussion: Knee arthroplasty surgeons may wish to harness the emerging benefits of both a conventionally instrumented technique and a patient-specific alignment strategy. Level of Evidence: Level V.

7.
J Exp Orthop ; 11(3): e12054, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38863938

RESUMEN

Purpose: The Knee Society Scoring System (KSS) is a frequently used outcome score which quantifies functional patients' outcomes before and after total knee arthroplasty (TKA). Several problems arise when trying to implement KSS for obtaining postoperative outcomes after more personalised aligned TKAs. Scoring for valgus femorotibial angle (FTA) intervals outside moderate ranges is often poorly explained, the specific version of KSS used for outcome collection is frequently unclear and the exact measuring methods are typically not described in the literature. The aims of this systematic review were to investigate the latest user practice, the application of KSS and its limitations after kinematically aligned (KA) TKA. Methods: A systematic literature search following PRISMA guidelines was conducted on PubMed, Embase, Medline and Scopus to identify potentially relevant articles for this review, published from the beginning of January 2013 until the end of January 2023. Broad Mesh terms such as 'kinematic alignment', 'total knee arthroplasty' and 'knee society score' were used for building search strategy in each database accordingly. Articles reporting postoperative values of the objective surgeon-assessed KSS after KA TKA or KA and mechanically aligned TKA were included. For assessing included randomised control trials (RCTs), an Agency for Healthcare Research and Quality's design-specific scale for assessing RCTs was used. The non-RCTs were assessed by using the Joanna Briggs Institute Critical Appraisal Tool. The Ottawa-Newcastle Score system was also used. Studies were additionally evaluated for their radiological methodology by using a five-question checklist (Radiological Assessment Qualit criteria). Results: The initial search identified 167 studies, of which 129 were considered for screening. Ten studies reporting outcomes after KA TKA did not use the objective surgeon-assessed part of KSS for clinical outcome measurement, and 30 studies reporting outcomes after KA TKA did not use KSS at all for clinical and/or functional outcomes. From the 10 included studies, only six have used the latest KSS score (2011), the rest using its 1989 variant; and out of these six studies, only two presented values of the FTA, which is needed for calculating the KSS's 'alignment' subcomponent, the rest presenting hip-knee-ankle angle (HKA) values. Additionally, when converting these HKA values to FTA intervals, the authors of this systematic review found that KA TKA FTA intervals display limits, which tend to be outside the 'well-scored' KSS anatomical alignment interval. Conclusion: The inconsistent and nonstandardised use of the surgeon-assessed KSS across studies reviewed compromises assessment reliability and patient outcome scores. To enhance precision and comparability, it is crucial to standardise the KSS application, incorporating personalised alignment strategies for more accurate patient evaluations. Level of Evidence: Level III.

11.
J Exp Orthop ; 11(3): e12025, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38715910

RESUMEN

Recent advances in artificial intelligence (AI) present a broad range of possibilities in medical research. However, orthopaedic researchers aiming to participate in research projects implementing AI-based techniques require a sound understanding of the technical fundamentals of this rapidly developing field. Initial sections of this technical primer provide an overview of the general and the more detailed taxonomy of AI methods. Researchers are presented with the technical basics of the most frequently performed machine learning (ML) tasks, such as classification, regression, clustering and dimensionality reduction. Additionally, the spectrum of supervision in ML including the domains of supervised, unsupervised, semisupervised and self-supervised learning will be explored. Recent advances in neural networks (NNs) and deep learning (DL) architectures have rendered them essential tools for the analysis of complex medical data, which warrants a rudimentary technical introduction to orthopaedic researchers. Furthermore, the capability of natural language processing (NLP) to interpret patterns in human language is discussed and may offer several potential applications in medical text classification, patient sentiment analysis and clinical decision support. The technical discussion concludes with the transformative potential of generative AI and large language models (LLMs) on AI research. Consequently, this second article of the series aims to equip orthopaedic researchers with the fundamental technical knowledge required to engage in interdisciplinary collaboration in AI-driven orthopaedic research. Level of Evidence: Level IV.

13.
J Orthop Traumatol ; 25(1): 12, 2024 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-38430413

RESUMEN

BACKGROUND: Alumina particles from the grit blasting of Ti-alloy stems are suspected to contribute to aseptic loosening. An alumina-reduced stem surface was hypothesized to improve osseointegration and show comparable short-term outcomes to those of a standard stem. METHODS: In this prospective, double-blind, randomized trial, 26 standard (STD) and 27 experimental new technology (NT) stems were implanted. The latter were additionally treated by acid etching and ice blasting to remove alumina particles from the grit-blasting process. Follow-up occurred at 12 and 24 months. Bone mineral density (BMD) around the stem was measured by a dual-energy x-ray absorptiometry device (DEXA). Radiographs were reviewed for alterations. Clinical scoring comprised the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the Harris Hip Score (HHS). Survival rates were calculated up to 50 months. RESULTS: Lower mean BMD and more severe cortical hypertrophies were found in the NT group. At 12 months, radiolucent lines were observed mostly in the metaphyseal zone for both groups, with a progression tendency in the NT group at 24 months. At 12 months, pain scores and the WOMAC total and physical activity scores were significantly lower in the NT group, without any differences thereafter. The number of NT stem revisions amounted to 6 (24%) and 11 (41%) at 24 and 50 months, respectively. CONCLUSION: In the NT group, unexpected catastrophic failure rates of 41% caused by early aseptic loosening were noted within 50 months. Compared with the STD stems, NT stems lead to poor clinical and radiographic results. LEVEL OF EVIDENCE: II. TRIAL REGISTRATION: NCT05053048.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Absorciometría de Fotón , Óxido de Aluminio , Artroplastia de Reemplazo de Cadera/métodos , Estudios de Seguimiento , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento , Método Doble Ciego
14.
Knee Surg Sports Traumatol Arthrosc ; 32(5): 1287-1297, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38504509

RESUMEN

PURPOSE: The present study focuses on testing the capability of a restricted tibia-first, gap-balanced patient-specific alignment technique (PSA) to restore bony morphology and phenotypes. METHODS: Three-hundred and sixty-seven patients were treated with navigated total knee arthroplasty and tibia-first gap-balanced PSA technique. Boundaries for medial proximal tibial angle were 86°-92°, mechanical lateral distal femoral angle 86°-92°, and hip-knee-ankle angle 175°-183°. Knees were classified by coronal plane alignment of the knee (CPAK), with subsequent analyses comparing pre- and postoperative distributions. Phenotype classification within CPAK groups assessed pre- and postoperative distributions. RESULTS: Preoperatively, the largest CPAK group was type II (30.8%), followed by type I (20.5%) and type V (17.8%). Postoperatively, type II remained the largest group (39%), followed by type V (30%). All groups with varus/valgus deformities (I, III, IV and VI) became smaller. While in straight legs (II, IV), the CPAK was restored in more than 70%-75%, in varus groups (I, IV) in 40%-50% and in valgus (III and VI) in 5%-18%. The joint line obliquity remained the same in the majority of knees (straight >75%; varus 63%-80%; valgus VI 95%), with the exception of CPAK III (40%). The phenotype analysis showed for straight legs a phenotype restoration of 85%, for varus 94% and for valgus 37%. Joint line convergence angle was reduced significantly in all groups from 1.8°-4.3° preoperatively to 0.6°-1.2° postoperatively. CONCLUSION: PSA restores bony phenotypes and joint line obliquity in the majority of straight and varus knees, while most of the valgus and extreme varus knees are normalised. LEVEL OF EVIDENCE: Level III, retrospective cohort study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla , Fenotipo , Tibia , Humanos , Masculino , Femenino , Artroplastia de Reemplazo de Rodilla/métodos , Anciano , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Persona de Mediana Edad , Tibia/cirugía , Desviación Ósea , Osteoartritis de la Rodilla/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Cirugía Asistida por Computador/métodos
15.
Knee ; 47: 151-159, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38394994

RESUMEN

BACKGROUND: The safety and the clinical success of simultaneous bilateral total knee arthroplasty (BTKA) is controversial. The aim of this study was to compare complications and patient-reported outcomes following simultaneous BTKA (simBTKA) versus staged BKTA (staBTKA) in patients affected by bilateral symptomatic end-stage knee osteoarthritis (OA). METHODS: Data from patients who underwent simBTKA or staBTKA at a single institution from January 2017 to December 2020, with a minimum 1-year follow up period were retrospectively collected. Differences in terms of complications and clinical success were compared among the simBTKA and staBTKA patient groups. Alpha was set at 0.05. RESULTS: A total of 173 patients were included in this study. The results revealed no statistically significant differences between the two groups in terms of mortality, revision rate, readmission rate, local and systemic complications and patient-reported outcomes. SimBTKA group had a shorter operating room time (96 (73-119) vs. 195 (159-227); P < 0.0001), and length of hospital stay (4 (3-5) vs. 7 (6-9); P < 0.0001) compared with the staBTKA group. CONCLUSIONS: SimBTKA performed in a selected patient population at a high-volume center can be considered comparable to staBTKA in terms of safety, postoperative complications, 30-day readmissions and patient satisfaction. Consequently, reduced operating room time and hospital stay renders simBTKA a cost-effective and advantageous option, not only for patients, but also for healthcare institutes. Furthermore, the current study also highlights the importance of correct patient selection based on clinical preoperative characteristics.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Readmisión del Paciente , Medición de Resultados Informados por el Paciente , Complicaciones Posoperatorias , Reoperación , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Masculino , Femenino , Readmisión del Paciente/estadística & datos numéricos , Anciano , Osteoartritis de la Rodilla/cirugía , Estudios Retrospectivos , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología
17.
J Pers Med ; 14(2)2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38392626

RESUMEN

BACKGROUND: A comprehensive exploration evaluating left-to-right knee symmetry across all anatomical planes utilizing three-dimensional (3D) scans stands absent from the existing body of research. Therefore, the primary objectives of this investigation involved examining potential differences and resemblances in alignment and structure between left and right non-osteoarthritic (native) knees in various planes (coronal, sagittal, and axial) using three-dimensional single-photon emission computed tomography/computed tomography (SPECT/CT) images. METHODS: A total of 282 native knees from 141 patients were retrospectively gathered from the hospital's records. Patients, aged between 16 and 45, who underwent Tc99m-methyl diphosphonate SPECT/CT scans for both knees, adhering to the Imperial Knee Protocol, were included. A statistical analysis was conducted, including 23 knee morphometric parameters, comparing left and right knees, and classifying them based on functional knee phenotypes across the coronal, sagittal, and axial planes. RESULTS: Regarding the functional coronal knee phenotype, 26% of patients (n = 37) exhibited identical phenotypes in both knees (p < 0.001). Significant correlated similarities between the left and right knees were observed in the coronal plane (Pearson's r = 0.76, 0.68, 0.76, 0.76, p < 0.001) and in several morphometric measures in the sagittal plane (Pearson's r = 0.92, 0.72, 0.64, p < 0.001). Moderately correlated similarities were noted in the axial plane (Pearson's r = 0.43, 0.44, 0.43, p < 0.001). CONCLUSIONS: Only 26% of native knees exhibit an identical coronal phenotype in their contralateral knee, whereas 67% have the adjacent coronal phenotype. Strongly correlated resemblances were established across various left and right knee morphometric parameters in the coronal, sagittal, and axial planes. These findings could enhance decisions in procedures like total knee arthroplasties or osteotomies, where alignment is key to outcomes, and reveal a potential for future artificial intelligence-driven models to improve our understanding and improve personalized treatment strategies for knee osteoarthritis.

18.
Artículo en Inglés | MEDLINE | ID: mdl-38415864

RESUMEN

PURPOSE: To identify gender differences in (1) the coronal alignment of functional knee phenotypes and (2) the JLCA (joint line convergence angle) in relation to the phenotype classification. METHODS: This study is a retrospective data analysis, including 12,099 osteoarthritic knee computed tomography (5025 male, 7074 female) analysed by Medacta software for hip-knee-ankle angle (HKA), femoral mechanical angle (FMA), tibial mechanical angle (TMA) and JLCA. The data were grouped into genders and combined according to the Functional Knee Phenotypes Classification. RESULTS: Out of 127 phenotypes for males and 131 for females, 17 common phenotypes were reported. The commonest four were similar for both genders with VARHKA177° NEUFMA93° NEUTMA87° (9.8% males, 9.50% females), followed by VARHKA174° NEUFMA93°VARTMA84° (7.1%) and VARHKA174°VARFMA90° NEUTMA87° (7.0%) for males and VARHKA174° NEUFMA93° NEUTMA87° (6.1%), VARHKA174° NEUFMA93°VARTMA84° (5.1%) for females. The commonest FMA and TMA (91.5° to 94.5° and 85.5° to 88.5°, respectively) were the same for both genders, however, the rest of the male population observed greater femoral varus than the female population (p < 0.001). JLCA values ranged from -28.4° to 8.2° in the overall study population. Males and females had a mean JLCA of -2.96° (±2.6° SD) and -2.66° (±2.8°7 SD), respectively, p < 0.001. CONCLUSIONS: Gender differences exist within the osteoarthritic knee phenotype. The male varus phenotype is influenced by FMA, while TMA values are similar across genders. JLCA variations show similarities to both TMA and FMA, suggesting JLCA is influenced by bone morphology more than by gender. These differences inform surgical decision-making for the personalised approach to the primary TKA. LEVEL OF EVIDENCE: Level III.

19.
Knee Surg Sports Traumatol Arthrosc ; 32(2): 473-489, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38293728

RESUMEN

PURPOSE: One of the most pertinent questions in total knee arthroplasty (TKA) is: what could be considered normal coronal alignment? This study aims to define normal, neutral, deviant and aberrant coronal alignment using large data from a computed tomography (CT)-scan database and previously published phenotypes. METHODS: Coronal alignment parameters from 11,191 knee osteoarthritis (OA) patients were measured based on three dimensional reconstructed CT data using a validated planning software. Based on these measurements, patients' coronal alignment was phenotyped according to the functional knee phenotype concept. These phenotypes represent an alignment variation of the overall hip knee ankle angle (HKA), femoral mechanical angle (FMA) and tibial mechanical angle (TMA). Each phenotype is defined by a specific mean and covers a range of ±1.5° from this mean. Coronal alignment is classified as normal, neutral, deviant and aberrant based on distribution frequency. Mean values and distribution among the phenotypes are presented and compared between two populations (OA patients in this study and non-OA patients from a previously published study). RESULTS: The arithmetic HKA (aHKA), combined normalised data of FMA and TMA, showed that 36.0% of knees were neutral within ±1 SD from the mean in both angles, 44.3% had either a TMA or a FMA within ±1-2 SD (normally aligned), 15.3% of the patients were deviant within ±2-3 SD and only 4.4% of them had an aberrant alignment (±3-4 SD in 3.4% and >4 SD in 1.0% of the patients respectively). However, combining the normalised data of HKA, FMA and TMA, 15.4% of patients were neutral in all three angles, 39.7% were at least normal, 27.7% had at least one deviant angle and 17.2% had at least one aberrant angle. For HKA, the males exhibited 1° varus and females were neutral. For FMA, the females exhibited 0.7° more valgus in mean than males and grew 1.8° per category (males grew 2.1° per category). For TMA, the males exhibited 1.3° more varus than females and both grew 2.3° and 2.4° (females) per category. Normal coronal alignment was 179.2° ± 2.8-5.6° (males) and 180.5 > ± 2.8-5.6° (females) for HKA, 93.1 > ± 2.1-4.2° (males) and 93.8 > ± 1.8-3.6° (females) for FMA and 86.7 > ± 2.3-4.6° (males) and 88 > ± 2.4-4.8° (females) for TMA. This means HKA 6.4 varus or 4.8° valgus (males) or 5.1° varus to 6.1° valgus was considered normal. For FMA HKA 1.1 varus or 7.3° valgus (males) or 0.2° valgus to 7.4° valgus was considered normal. For TMA HKA 7.9 varus or 1.3° valgus (males) or 6.8° varus to 2.8° valgus was considered normal. Aberrant coronal alignment started from 179.2° ± 8.4° (males) and 180.5 > ± 8.4° (females) for HKA, 93.1 > ± 6.3° (males) 93.8 > ± 5.4° (females) for FMA and 86.7 > ± 6.9° (males) and 88 > ± 7.2° (females) for TMA. This means HKA > 9.2° varus or 7.6° valgus (males) or 7.9° varus to 8.9° valgus was considered aberrant. CONCLUSION: Definitions of neutrality, normality, deviance as well as aberrance for coronal alignment in TKA were proposed in this study according to their distribution frequencies. This can be seen as an important first step towards a safe transition from the conventional one-size-fits-all to a more personalised coronal alignment target. There should be further definitions combining bony alignment, joint surfaces' morphology, soft tissue laxities and joint kinematics. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Masculino , Femenino , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Extremidad Inferior , Tibia/diagnóstico por imagen , Tibia/cirugía , Fémur/cirugía , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...