Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur Heart J Cardiovasc Imaging ; 25(7): 914-925, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38525948

RESUMEN

AIMS: Current assessment of myocardial ischaemia from stress perfusion cardiovascular magnetic resonance (SP-CMR) largely relies on visual interpretation. This study investigated the use of high-resolution free-breathing SP-CMR with automated quantitative mapping in the diagnosis of coronary artery disease (CAD). Diagnostic performance was evaluated against invasive coronary angiography (ICA) with fractional flow reserve (FFR) measurement. METHODS AND RESULTS: Seven hundred and three patients were recruited for SP-CMR using the research sequence at 3 Tesla. Of those receiving ICA within 6 months, 80 patients had either FFR measurement or identification of a chronic total occlusion (CTO) with inducible perfusion defects seen on SP-CMR. Myocardial blood flow (MBF) maps were automatically generated in-line on the scanner following image acquisition at hyperaemic stress and rest, allowing myocardial perfusion reserve (MPR) calculation. Seventy-five coronary vessels assessed by FFR and 28 vessels with CTO were evaluated at both segmental and coronary territory level. Coronary territory stress MBF and MPR were reduced in FFR-positive (≤0.80) regions [median stress MBF: 1.74 (0.90-2.17) mL/min/g; MPR: 1.67 (1.10-1.89)] compared with FFR-negative regions [stress MBF: 2.50 (2.15-2.95) mL/min/g; MPR 2.35 (2.06-2.54) P < 0.001 for both]. Stress MBF ≤ 1.94 mL/min/g and MPR ≤ 1.97 accurately detected FFR-positive CAD on a per-vessel basis (area under the curve: 0.85 and 0.96, respectively; P < 0.001 for both). CONCLUSION: A novel scanner-integrated high-resolution free-breathing SP-CMR sequence with automated in-line perfusion mapping is presented which accurately detects functionally significant CAD.


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Imagen por Resonancia Cinemagnética , Humanos , Femenino , Masculino , Persona de Mediana Edad , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Reserva del Flujo Fraccional Miocárdico/fisiología , Angiografía Coronaria/métodos , Anciano , Imagen por Resonancia Cinemagnética/métodos , Imagen de Perfusión Miocárdica/métodos , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad
2.
J Med Syst ; 45(3): 30, 2021 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-33511485

RESUMEN

The aim of this study was to evaluate the performance of a tablet-based, digitized structured self-assessment (DSSA) of patient anamnesis (PA) prior to computed tomography (CT). Of the 317 patients consecutively referred for CT, the majority (n = 294) was able to complete the tablet-based questionnaire, which consisted of 67 items covering social anamnesis, lifestyle factors (e.g., tobacco abuse), medical history (e.g., kidney diseases), current symptoms, and the usability of the system. Patients were able to mark unclear questions for a subsequent discussion with the radiologist. Critical issues for the CT examination were structured and automatically highlighted as "red flags" (RFs) in order to improve patient interaction. RFs and marked questions were highly prevalent (69.5% and 26%). Missing creatinine values (33.3%), kidney diseases (14.4%), thyroid diseases (10.6%), metformin (5.5%), claustrophobia (4.1%), allergic reactions to contrast agents (2.4%), and pathological TSH values (2.0%) were highlighted most frequently as RFs. Patient feedback regarding the comprehensibility of the questionnaire and the tablet usability was mainly positive (90.9%; 86.2%). With advanced age, however, patients provided more negative feedback for both (p = 0.007; p = 0.039). The time effort was less than 20 min for 85.1% of patients, and faster patients were significantly younger (p = 0.046). Overall, the DSSA of PA prior to CT shows a high success rate and is well accepted by most patients. RFs and marked questions were common and helped to focus patients' interactions and reporting towards decisive aspects.


Asunto(s)
Autoevaluación (Psicología) , Tomografía Computarizada por Rayos X , Retroalimentación , Humanos , Encuestas y Cuestionarios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...