Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Anal Chim Acta ; 950: 1-6, 2017 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-27916114

RESUMEN

Analytical methods that are often used for the quantification of progesterone in bovine milk include immunoassays and chromatographic techniques. Depending on the selected method, the main disadvantages are the cost, time-to-result, labor intensity and usability as an automated at-line device. This paper reports for the first time on a robust and practical method to quantify small molecules, such as progesterone, in complex biological samples using an automated fiber optic surface plasmon resonance (FO-SPR) biosensor. A FO-SPR competitive inhibition assay was developed to determine biologically relevant concentrations of progesterone in bovine milk (1-10 ng/mL), after optimizing the immobilization of progesterone-bovine serum albumin (P4-BSA) conjugate, the specific detection with anti-progesterone antibody and the signal amplification with goat anti-mouse gold nanoparticles (GAM-Au NPs). The progesterone was detected in a bovine milk sample with minimal sample preparation, namely ½ dilution of the sample. Furthermore, the developed bioassay was benchmarked against a commercially available ELISA, showing excellent agreement (R2 = 0.95). Therefore, it is concluded that the automated FO-SPR platform can combine the advantages of the different existing methods for quantification of progesterone: sensitivity, accuracy, cost, time-to-result and ease-of-use.


Asunto(s)
Técnicas Biosensibles , Leche/química , Progesterona/análisis , Animales , Bovinos , Oro , Nanopartículas del Metal , Resonancia por Plasmón de Superficie
2.
Animal ; 10(9): 1557-66, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25959418

RESUMEN

Changes in the drinking behaviour of pigs may indicate health, welfare or productivity problems. Automated monitoring and analysis of drinking behaviour could allow problems to be detected, thus improving farm productivity. A high frequency radio frequency identification (HF RFID) system was designed to register the drinking behaviour of individual pigs. HF RFID antennas were placed around four nipple drinkers and connected to a reader via a multiplexer. A total of 55 growing-finishing pigs were fitted with radio frequency identification (RFID) ear tags, one in each ear. RFID-based drinking visits were created from the RFID registrations using a bout criterion and a minimum and maximum duration criterion. The HF RFID system was successfully validated by comparing RFID-based visits with visual observations and flow meter measurements based on visit overlap. Sensitivity was at least 92%, specificity 93%, precision 90% and accuracy 93%. RFID-based drinking duration had a high correlation with observed drinking duration (R 2=0.88) and water usage (R 2=0.71). The number of registrations after applying the visit criteria had an even higher correlation with the same two variables (R 2=0.90 and 0.75, respectively). There was also a correlation between number of RFID visits and number of observed visits (R 2=0.84). The system provides good quality information about the drinking behaviour of individual pigs. As health or other problems affect the pigs' drinking behaviour, analysis of the RFID data could allow problems to be detected and signalled to the farmer. This information can help to improve the productivity and economics of the farm as well as the health and welfare of the pigs.


Asunto(s)
Conducta de Ingestión de Líquido , Vivienda para Animales , Dispositivo de Identificación por Radiofrecuencia/métodos , Sus scrofa/fisiología , Animales , Femenino , Masculino
3.
J Dairy Sci ; 98(10): 6727-38, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26210269

RESUMEN

The implementation of optical sensor technology to monitor the milk quality on dairy farms and milk processing plants would support the early detection of altering production processes. Basic visible and near-infrared spectroscopy is already widely used to measure the composition of agricultural and food products. However, to obtain maximal performance, the design of such optical sensors should be optimized with regard to the optical properties of the samples to be measured. Therefore, the aim of this study was to determine the visible and near-infrared bulk absorption coefficient, bulk scattering coefficient, and scattering anisotropy spectra for a diverse set of raw milk samples originating from individual cow milkings, representing the milk variability present on dairy farms. Accordingly, this database of bulk optical properties can be used in future simulation studies to efficiently optimize and validate the design of an optical milk quality sensor. In a next step of the current study, the relation between the obtained bulk optical properties and milk quality properties was analyzed in detail. The bulk absorption coefficient spectra were found to mainly contain information on the water, fat, and casein content, whereas the bulk scattering coefficient spectra were found to be primarily influenced by the quantity and the size of the fat globules. Moreover, a strong positive correlation (r ≥ 0.975) was found between the fat content in raw milk and the measured bulk scattering coefficients in the 1,300 to 1,400 nm wavelength range. Relative to the bulk scattering coefficient, the variability on the scattering anisotropy factor was found to be limited. This is because the milk scattering anisotropy is nearly independent of the fat globule and casein micelle quantity, while it is mainly determined by the size of the fat globules. As this study shows high correlations between the sample's bulk optical properties and the milk composition and fat globule size, a sensor that allows for robust separation between the absorption and scattering properties would enable accurate prediction of the raw milk quality parameters.


Asunto(s)
Leche/química , Espectroscopía Infrarroja Corta , Animales , Fenómenos Ópticos , Valores de Referencia
4.
J Dairy Sci ; 97(6): 3371-81, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24731631

RESUMEN

Sensors play a crucial role in the future of dairy farming. Modern dairy farms today are equipped with many different sensors for milk yield, body weight, activity, and even milk composition. The challenge, however, is to translate signals from these sensors into relevant information for the farmer. Because the measured values for an individual cow show nonstationary behavior, the concepts of statistical process control, which are commonly used in industry, cannot be used directly. The synergistic control concept overcomes this problem by on-line (real-time) modeling of the process and application of statistical process control to the residuals between the measured and modeled values. In this study, the synergistic control concept was developed and tested for early detection of anomalies in dairy cows based on detection of shifts in milk yield. Compared with the combination of visual observation and milk conductivity measurements, the developed strategy had a sensitivity of 63% for detecting clinical mastitis. Consequently, this technique could have added value on many farms, as it extracts practical information out of inexpensive data that are already available. As it can be easily extended to other measured parameters, the technique shows potential for early detection of other nutrition and health problems.


Asunto(s)
Industria Lechera/métodos , Mastitis Bovina/diagnóstico , Leche/metabolismo , Sistemas en Línea , Animales , Bovinos , Femenino , Lactancia , Mastitis Bovina/tratamiento farmacológico , Modelos Biológicos , Sensibilidad y Especificidad
5.
J Chromatogr A ; 922(1-2): 207-18, 2001 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-11486865

RESUMEN

A recently developed method for the sampling and analysis of volatile organic compounds in air has been evaluated. The system is based on the enrichment of analytes in tetraethylene glycol dimethyl ether or tetraglyme, a water-soluble organic liquid. The subsequent analysis consists of dispersion of a sample aliquot in water followed by purge-and-trap and gas chromatographic separation. Physico-chemical data were investigated for 10 volatile organic compounds, providing information on the possibilities and limitations of the tetraglyme method. The target analytes included chlorinated alkanes and alkenes, and monocyclic aromatic hydrocarbons. Air/tetraglyme partition coefficients Kat were determined over an environmental relevant temperature range of 2-25 degrees C to evaluate sorption efficiencies and estimate breakthrough volumes at the sampling stage. At 2 degrees C breakthrough volumes (allowing 5% of breakthrough) ranged from 5.8 (1,1-dichloroethane) to 312 l (1,1,2-trichloroethane) for 20 ml of tetraglyme. With regard to the desorption stage, the effect of tetraglyme on the air/water partition of organic compounds was investigated through the measurement of air/tetraglyme-water partition coefficients Kat-w for 2-31% (v/v) tetraglyme in water. Finally a clean-up procedure for tetraglyme was evaluated. Analysis of a blank tetraglyme-water (17:83, v:v) mixture by gas chromatography-flame ionization detection/mass spectrometry showed minor background signals. None of the target compounds were detected.


Asunto(s)
Aire/análisis , Glicoles de Etileno/química , Compuestos Orgánicos/análisis , Volatilización
6.
J Chromatogr A ; 893(2): 367-82, 2000 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-11073305

RESUMEN

Purge-and-trap combined with high-resolution gas chromatography and detection by mass spectrometry was evaluated for the analysis of 27 volatile organic compounds (VOCs) in marine water samples down to ng l(-1) concentration levels. The target compounds included chlorinated alkanes and alkenes, monocyclic aromatic hydrocarbons and chlorinated monocyclic aromatic hydrocarbons and covered a wide range of VOCs of environmental interest. Limits of detection ranged from 0.15 ng l(-1) to 6.57 ng l(-1) for all VOCs, except for dichloromethane (41.07 ng l(-1)), chloroform (19.74 ng l(-1)), benzene (22.05 ng l(-1)) and 1,4-dichlorobenzene (20.43 ng l(-1)). Precision and accuracy were determined at a concentration level of 25.97 to 66.68 ng l(-1). Besides method validation, emphasis was put on quality control and assessment during routine determination of VOCs in marine water samples. Analytical quality control charts were plotted for all VOCs and a standard addition test was performed, as proposed by the QUASIMEME (Quality Assurance of Information in Marine Environmental Monitoring Programmes in Europe) working group. The analytical charts were incorporated in a working scheme containing guidelines to be applied during routine determinations, ensuring the long time reliability of the analytical method. Results yielded by the QUASIMEME interlaboratory exercise on organohalogen measurements in seawater are presented. The exercise was attended by seven out of eight laboratories who agreed to participate. Samples taken along the Scheldt estuary, from Breskens (The Netherlands) to Temse (Antwerp, Belgium) were analysed according to the developed technique. Concentrations as low as 0.33 ng l(-1) (1,2-dichloropropane) were detected near the mouth of the river Scheldt, while concentrations up to 326 ng l(-1) for tetrachloroethene and 461 ng l(-1) for cyclohexane were found in the vicinity of Antwerp.


Asunto(s)
Cromatografía de Gases y Espectrometría de Masas/métodos , Compuestos Orgánicos/análisis , Agua de Mar/análisis , Compuestos Orgánicos/clasificación , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Volatilización
7.
Proc AMIA Symp ; : 12-6, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10566311

RESUMEN

In oncology various international and national standards exist for the documentation of different aspects of a disease. Since elements of these standards are repeated in different contexts, a common data dictionary could support consistent representation in any context. For the construction of such a dictionary existing documents have to be worked up in a complex procedure, that considers aspects of hierarchical decomposition of documents and of domain control as well as aspects of user presentation and models of the underlying model of patient data. In contrast to other thesauri, text chunks like definitions or explanations are very important and have to be preserved, since oncologic documentation often means coding and classification on an aggregate level and the safe use of coding systems is an important precondition for comparability of data. This paper discusses the potentials of the use of XML in combination with a dictionary for the promotion and development of standard conformable applications for tumor documentation.


Asunto(s)
Documentación/normas , Neoplasias/clasificación , Lenguajes de Programación , Vocabulario Controlado , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...