1.
Biomaterials ; 19(10): 941-51, 1998 May.
Artículo en Inglés | MEDLINE | ID: mdl-9690836

RESUMEN

The degradation and tissue compatibility characteristics of a novel class of biodegradable poly(anhydride-co-imide) polymers: poly[trimellitylimidoglycine-co-1,6-bis(carboxyphenoxy)hexan e] (TMA-gly: CPH) (in 10:90; 30:70 and 50: 50 molar ratios) and poly[pyromellitylimidoalanine-co-1,6-bis(carboxyphenoxy)hexa ne] (PMA-ala:CPH) (in 10:90 and 30:70 molar ratios) were investigated and compared with control poly(lactic acid/glycolic acid) (PLAGA in 50:50 molar ratio) matrices, a well-characterized biocompatible polymer, in rat subcutaneous tissues for 60 days. Polymers were compression-molded into circular discs of 14 mm x 1 mm in diameter. On post-operative days 7, 14, 28 and 60, histological tissue samples were removed, prepared by fixation and staining, and analyzed by light microscopy. PLAGA matrices produced mild inflammatory reactions and were completely degraded at the end of 60 days, leaving implant tissues that were similar to surgical wounds without implants. TMA-gly:CPH (10:90 and 30:70) matrices produced mild inflammatory reactions by the end of 60 days, similar to those seen with PLAGA. TMA-gly: CPH (50: 50) produced moderate inflammatory reactions characterized by macrophages and edema. PMA-ala:CPH matrices elicited minimal inflammatory reactions that were characterized by fibrous encapsulation by the end of 60 days. In vivo degradation rates of poly(anhydride-co-imides) were similar to PLAGA. Both PMA-ala:CPH and TMA-gly: CPH matrices maintained their shapes and degraded at a constant rate over the period of two months. These polymers, possessing good mechanical properties and tissue compatibility, may be useful in weight-bearing applications in bone.


Asunto(s)
Materiales Biocompatibles/farmacología , Hexanos/farmacología , Polímeros/farmacología , Prótesis e Implantes , Piel/efectos de los fármacos , Reacción de Fase Aguda/inducido químicamente , Animales , Materiales Biocompatibles/toxicidad , Hexanos/toxicidad , Ácido Láctico/farmacología , Ácido Láctico/toxicidad , Macrófagos/patología , Masculino , Neutrófilos/patología , Fagocitosis , Ácido Poliglicólico/farmacología , Ácido Poliglicólico/toxicidad , Copolímero de Ácido Poliláctico-Ácido Poliglicólico , Polímeros/toxicidad , Ratas , Ratas Sprague-Dawley , Piel/inmunología , Piel/patología , Factores de Tiempo
2.
Pharm Dev Technol ; 3(1): 55-62, 1998 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-9532600

RESUMEN

A colchicine release system utilizing biodegradable poly(phosphazenes) was investigated in vitro for intra-articular administration. Polymer degradation and drug release studies were performed on colchicine-loaded poly(phosphazenes) containing either imidazolyl (I-PPHOS) or ethyl glycinato (EG-PPHOS) side chain substituents over a 21-day period. To study the effects of an implantable colchicine-PPHOS delivery system on local musculoskeletal tissue in vitro, osteoblast-like cells were grown on the matrices. Colchicine release was 20% for I-PPHOS and 60% for EG-PPHOS over the 21-day period. Release appeared to proceed through a combination of diffusional and degradative mechanisms. Environmental scanning electron microscopy (ESEM) studies revealed large pores in the drug-depleted devices in contrast to the control matrices without drug, which may have contributed to the release seen, especially with ethyl glycinato-containing matrices. Cell growth on matrices containing colchicine was significantly (p < 0.05) inhibited in contrast to growth on tissue culture polystyrene (TCPS) and EG-PPHOS matrices without drug. The in vitro cell kinetic data suggest that designs for in vivo studies must take into account possible toxicity of colchicine and the polymer matrix on local tissue. Biodegradable PPHOS systems are promising candidates for use as intra-articular delivery vehicles for drugs with potential for systemic toxicity.


Asunto(s)
Antiinflamatorios no Esteroideos/administración & dosificación , Materiales Biocompatibles , Colchicina/administración & dosificación , Sistema Musculoesquelético , Compuestos Organofosforados , Polímeros , Células 3T3 , Animales , Antiinflamatorios no Esteroideos/farmacocinética , Antiinflamatorios no Esteroideos/farmacología , División Celular/efectos de los fármacos , Colchicina/farmacocinética , Colchicina/farmacología , Ratones , Microscopía Electrónica de Rastreo