Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 143
Filtrar
1.
Cancer Res Commun ; 4(10): 2565-2574, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39240065

RESUMEN

Oxygen-enhanced MRI (OE-MRI) has shown promise for quantifying and spatially mapping tumor hypoxia, either alone or in combination with perfusion imaging. Previous studies have validated the technique in mouse models and in patients with cancer. Here, we report the first evidence that OE-MRI can track change in tumor oxygenation induced by two drugs designed to modify hypoxia. Mechanism of action of banoxantrone and atovaquone were confirmed using in vitro experiments. Next, in vivo OE-MRI studies were performed in Calu6 and U87 xenograft tumor models, alongside fluorine-18-fluoroazomycin arabinoside PET and immunohistochemistry assays of hypoxia. Neither drug altered tumor size. Banoxantrone reduced OE-MRI hypoxic fraction in Calu6 tumors by 52.5% ± 12.0% (P = 0.008) and in U87 tumors by 29.0% ± 15.8% (P = 0.004) after 3 days treatment. Atovaquone reduced OE-MRI hypoxic fraction in Calu6 tumors by 53.4% ± 15.3% (P = 0.002) after 7 days therapy. PET and immunohistochemistry provided independent validation of the MRI findings. Finally, combined OE-MRI and perfusion imaging showed that hypoxic tissue was converted into necrotic tissue when treated by the hypoxia-activated cytotoxic prodrug banoxantrone, whereas hypoxic tissue became normoxic when treated by atovaquone, an inhibitor of mitochondrial complex III of the electron transport chain. OE-MRI detected and quantified hypoxia reduction induced by two hypoxia-modifying therapies and could distinguish between their differential mechanisms of action. These data support clinical translation of OE-MRI biomarkers in clinical trials of hypoxia-modifying agents to identify patients demonstrating biological response and to optimize treatment timing and scheduling. Significance: For the first time, we show that hypoxic fraction measured by oxygen-enhanced MRI (OE-MRI) detected changes in tumor oxygenation induced by two drugs designed specifically to modify hypoxia. Furthermore, when combined with perfusion imaging, OE-MRI hypoxic volume distinguished the two drug mechanisms of action. This imaging technology has potential to facilitate drug development, enrich clinical trial design, and accelerate clinical translation of novel therapeutics into clinical use.


Asunto(s)
Atovacuona , Imagen por Resonancia Magnética , Oxígeno , Atovacuona/farmacología , Atovacuona/uso terapéutico , Animales , Humanos , Imagen por Resonancia Magnética/métodos , Ratones , Oxígeno/metabolismo , Línea Celular Tumoral , Ensayos Antitumor por Modelo de Xenoinjerto , Hipoxia Tumoral/efectos de los fármacos , Tomografía de Emisión de Positrones/métodos , Femenino , Ratones Desnudos
2.
Clin Cancer Res ; 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39142654

RESUMEN

PURPOSE: Hypoxia mediates treatment resistance in solid tumors. We evaluated if oxygen-enhanced (OE)-MRI-derived hypoxic volume (HVMRI) is repeatable and can detect radiotherapy-induced hypoxia modification in HPV-associated oropharyngeal head and neck squamous cell cancer (HNSCC). EXPERIMENTAL DESIGN: 27 patients were recruited prospectively between March 2021 and January 2024. HVMRI was measured in primary and nodal tumors prior to standard-of-care (chemo)radiotherapy then at weeks 2 and 4 (W2, W4) into therapy. Two pre-treatment scans assessed biomarker within-subject coefficient of variation (wCV) and repeatability coefficient (RC). Cohort treatment response was measured using mixed-effects modelling. Responding lesions were identified by comparing HVMRI change to RC limits of agreement (LOA). RESULTS: OE-MRI identified hypoxia in all lesions. HVMRI wCV was 24.6% and RC LOA were -45.7% to 84.1%. Cohort median pre-treatment HVMRI of 11.3 cm3 reduced to 6.9 cm3 at W2 and 5.9 cm3 at W4 (both p < 0.001). HVMRI was reduced in 54.5% of individual lesions by W2 and in 88.2% by W4. All lesions with W2 hypoxia reduction showed persistent modification at W4. HVMRI reduced in some lesions that showed no overall volume change. Hypoxia modification was discordant between primary and nodal tumors in 50.0% of patients. CONCLUSIONS: Radiation-induced hypoxia modification can occur as early as W2, but onset varies between patients and was not necessarily associated with overall size change. Half of all patients had discordant changes in primary and nodal tumors. These findings have implications for patient selection and timing of dose de-escalation strategies in HPV-associated oropharyngeal carcinoma.

3.
Eur Radiol ; 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39122855

RESUMEN

OBJECTIVES: To measure dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) biomarker repeatability in patients with non-small cell lung cancer (NSCLC). To use these statistics to identify which individual target lesions show early biological response. MATERIALS AND METHODS: A single-centre, prospective DCE-MRI study was performed between September 2015 and April 2017. Patients with NSCLC were scanned before standard-of-care radiotherapy to evaluate biomarker repeatability and two weeks into therapy to evaluate biological response. Volume transfer constant (Ktrans), extravascular extracellular space volume fraction (ve) and plasma volume fraction (vp) were measured at each timepoint along with tumour volume. Repeatability was assessed using a within-subject coefficient of variation (wCV) and repeatability coefficient (RC). Cohort treatment effects on biomarkers were estimated using mixed-effects models. RC limits of agreement revealed which individual target lesions changed beyond that expected with biomarker daily variation. RESULTS: Fourteen patients (mean age, 67 years +/- 12, 8 men) had 22 evaluable lesions (12 primary tumours, 8 nodal metastases, 2 distant metastases). The wCV (in 8/14 patients) was between 9.16% to 17.02% for all biomarkers except for vp, which was 42.44%. Cohort-level changes were significant for Ktrans and ve (p < 0.001) and tumour volume (p = 0.002). Ktrans and tumour volume consistently showed the greatest number of individual lesions showing biological response. In distinction, no individual lesions had a real change in ve despite the cohort-level change. CONCLUSION: Identifying individual early biological responders provided additional information to that derived from conventional cohort cohort-level statistics, helping to prioritise which parameters would be best taken forward into future studies. CLINICAL RELEVANCE STATEMENT: Dynamic contrast-enhanced magnetic resonance imaging biomarkers Ktrans and tumour volume are repeatable and detect early treatment-induced changes at both cohort and individual lesion levels, supporting their use in further evaluation of radiotherapy and targeted therapeutics. KEY POINTS: Few literature studies report quantitative imaging biomarker precision, by measuring repeatability or reproducibility. Several DCE-MRI biomarkers of lung cancer tumour microenvironment were highly repeatable. Repeatability coefficient measurements enabled lesion-specific evaluation of early biological response to therapy, improving conventional assessment.

4.
Nat Biotechnol ; 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38769424

RESUMEN

The construction of synthetic gene circuits in plants has been limited by a lack of orthogonal and modular parts. Here, we implement a CRISPR (clustered regularly interspaced short palindromic repeats) interference (CRISPRi)-based reversible gene circuit platform in plants. We create a toolkit of engineered repressible promoters of different strengths and construct NOT and NOR gates in Arabidopsis thaliana protoplasts. We determine the optimal processing system to express single guide RNAs from RNA Pol II promoters to introduce NOR gate programmability for interfacing with host regulatory sequences. The performance of a NOR gate in stably transformed Arabidopsis plants demonstrates the system's programmability and reversibility in a complex multicellular organism. Furthermore, cross-species activity of CRISPRi-based logic gates is shown in Physcomitrium patens, Triticum aestivum and Brassica napus protoplasts. Layering multiple NOR gates together creates OR, NIMPLY and AND logic functions, highlighting the modularity of our system. Our CRISPRi circuits are orthogonal, compact, reversible, programmable and modular and provide a platform for sophisticated spatiotemporal control of gene expression in plants.

6.
Magn Reson Med ; 91(3): 955-971, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37984456

RESUMEN

PURPOSE: Dynamic lung oxygen-enhanced MRI (OE-MRI) is challenging due to the presence of confounding signals and poor signal-to-noise ratio, particularly at 3 T. We have created a robust pipeline utilizing independent component analysis (ICA) to automatically extract the oxygen-induced signal change from confounding factors to improve the accuracy and sensitivity of lung OE-MRI. METHODS: Dynamic OE-MRI was performed on healthy participants using a dual-echo multi-slice spoiled gradient echo sequence at 3 T and cyclical gas delivery. ICA was applied to each echo within a thoracic mask. The ICA component relating to the oxygen-enhancement signal was automatically identified using correlation analysis. The oxygen-enhancement component was reconstructed, and the percentage signal enhancement (PSE) was calculated. The lung PSE of current smokers was compared with nonsmokers; scan-rescan repeatability, ICA pipeline repeatability, and reproducibility between two vendors were assessed. RESULTS: ICA successfully extracted a consistent oxygen-enhancement component for all participants. Lung tissue and oxygenated blood displayed the opposite oxygen-induced signal enhancements. A significant difference in PSE was observed between the lungs of current smokers and nonsmokers. The scan-rescan repeatability and the ICA pipeline repeatability were good. CONCLUSION: The developed pipeline demonstrated sensitivity to the signal enhancements of the lung tissue and oxygenated blood at 3 T. The difference in lung PSE between current smokers and nonsmokers indicates a likely sensitivity to lung function alterations that may be seen in mild pathology, supporting future use of our methods in patient studies.


Asunto(s)
Pulmón , Oxígeno , Humanos , Reproducibilidad de los Resultados , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos
7.
Magn Reson Med ; 91(3): 972-986, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38013206

RESUMEN

PURPOSE: To demonstrate proof-of-concept of a T2 *-sensitized oxygen-enhanced MRI (OE-MRI) method at 3T by assessing signal characteristics, repeatability, and reproducibility of dynamic lung OE-MRI metrics in healthy volunteers. METHODS: We performed sequence-specific simulations for protocol optimisation and acquired free-breathing OE-MRI data from 16 healthy subjects using a dual-echo RF-spoiled gradient echo approach at 3T across two institutions. Non-linear registration and tissue density correction were applied. Derived metrics included percent signal enhancement (PSE), ∆R2 * and wash-in time normalized for breathing rate (τ-nBR). Inter-scanner reproducibility and intra-scanner repeatability were evaluated using intra-class correlation coefficient (ICC), repeatability coefficient, reproducibility coefficient, and Bland-Altman analysis. RESULTS: Simulations and experimental data show negative contrast upon oxygen inhalation, due to substantial dominance of ∆R2 * at TE > 0.2 ms. Density correction improved signal fluctuations. Density-corrected mean PSE values, aligned with simulations, display TE-dependence, and an anterior-to-posterior PSE reduction trend at TE1 . ∆R2 * maps exhibit spatial heterogeneity in oxygen delivery, featuring anterior-to-posterior R2 * increase. Mean T2 * values across 32 scans were 0.68 and 0.62 ms for pre- and post-O2 inhalation, respectively. Excellent or good agreement emerged from all intra-, inter-scanner and inter-rater variability tests for PSE and ∆R2 *. However, ICC values for τ-nBR demonstrated limited agreement between repeated measures. CONCLUSION: Our results demonstrate the feasibility of a T2 *-weighted method utilizing a dual-echo RF-spoiled gradient echo approach, simultaneously capturing PSE, ∆R2 * changes, and oxygen wash-in during free-breathing. The excellent or good repeatability and reproducibility on intra- and inter-scanner PSE and ∆R2 * suggest potential utility in multi-center clinical applications.


Asunto(s)
Imagen por Resonancia Magnética , Oxígeno , Humanos , Reproducibilidad de los Resultados , Estudios de Factibilidad , Imagen por Resonancia Magnética/métodos , Pulmón/diagnóstico por imagen
8.
Magn Reson Med ; 91(5): 1803-1821, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38115695

RESUMEN

PURPOSE: K trans $$ {K}^{\mathrm{trans}} $$ has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for K trans $$ {K}^{\mathrm{trans}} $$ quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging-Dynamic Contrast-Enhanced (OSIPI-DCE) challenge was designed to benchmark methods to better help the efforts to standardize K trans $$ {K}^{\mathrm{trans}} $$ measurement. METHODS: A framework was created to evaluate K trans $$ {K}^{\mathrm{trans}} $$ values produced by DCE-MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for K trans $$ {K}^{\mathrm{trans}} $$ quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' K trans $$ {K}^{\mathrm{trans}} $$ values, the applied software, and a standard operating procedure. These were evaluated using the proposed OSIP I gold $$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score defined with accuracy, repeatability, and reproducibility components. RESULTS: Across the 10 received submissions, the OSIP I gold $$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0-1 = lowest-highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in K trans $$ {K}^{\mathrm{trans}} $$ analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility. CONCLUSIONS: This study reports results from the OSIPI-DCE challenge and highlights the high inter-software variability within K trans $$ {K}^{\mathrm{trans}} $$ estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real-world clinical setting, many of these tools may perform differently with different benchmarking methodology.


Asunto(s)
Medios de Contraste , Imagen por Resonancia Magnética , Humanos , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Programas Informáticos , Algoritmos
9.
Nat Plants ; 9(9): 1500-1513, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37666965

RESUMEN

Lateral roots are typically maintained at non-vertical angles with respect to gravity. These gravitropic setpoint angles are intriguing because their maintenance requires that roots are able to effect growth response both with and against the gravity vector, a phenomenon previously attributed to gravitropism acting against an antigravitropic offset mechanism. Here we show how the components mediating gravitropism in the vertical primary root-PINs and phosphatases acting upon them-are reconfigured in their regulation such that lateral root growth at a range of angles can be maintained. We show that the ability of Arabidopsis lateral roots to bend both downward and upward requires the generation of auxin asymmetries and is driven by angle-dependent variation in downward gravitropic auxin flux acting against angle-independent upward, antigravitropic flux. Further, we demonstrate a symmetry in auxin distribution in lateral roots at gravitropic setpoint angle that can be traced back to a net, balanced polarization of PIN3 and PIN7 auxin transporters in the columella. These auxin fluxes are shifted by altering PIN protein phosphoregulation in the columella, either by introducing PIN3 phosphovariant versions or via manipulation of levels of the phosphatase subunit PP2A/RCN1. Finally, we show that auxin, in addition to driving lateral root directional growth, acts within the lateral root columella to induce more vertical growth by increasing RCN1 levels, causing a downward shift in PIN3 localization, thereby diminishing the magnitude of the upward, antigravitropic auxin flux.


Asunto(s)
Arabidopsis , Gravitropismo , Ácidos Indolacéticos , Proteínas de Transporte de Membrana , Monoéster Fosfórico Hidrolasas
10.
Microbiol Spectr ; : e0135023, 2023 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-37646508

RESUMEN

Assuring that cell therapy products are safe before releasing them for use in patients is critical. Currently, compendial sterility testing for bacteria and fungi can take 7-14 days. The goal of this work was to develop a rapid untargeted approach for the sensitive detection of microbial contaminants at low abundance from low volume samples during the manufacturing process of cell therapies. We developed a long-read sequencing methodology using Oxford Nanopore Technologies MinION platform with 16S and 18S amplicon sequencing to detect USP <71> organisms and other microbial species. Reads are classified metagenomically to predict the microbial species. We used an extreme gradient boosting machine learning algorithm (XGBoost) to first assess if a sample is contaminated, and second, determine whether the predicted contaminant is correctly classified or misclassified. The model was used to make a final decision on the sterility status of the input sample. An optimized experimental and bioinformatics pipeline starting from spiked species through to sequenced reads allowed for the detection of microbial samples at 10 colony-forming units (CFU)/mL using metagenomic classification. Machine learning can be coupled with long-read sequencing to detect and identify sample sterility status and microbial species present in T-cell cultures, including the USP <71> organisms to 10 CFU/mL. IMPORTANCE This research presents a novel method for rapidly and accurately detecting microbial contaminants in cell therapy products, which is essential for ensuring patient safety. Traditional testing methods are time-consuming, taking 7-14 days, while our approach can significantly reduce this time. By combining advanced long-read nanopore sequencing techniques and machine learning, we can effectively identify the presence and types of microbial contaminants at low abundance levels. This breakthrough has the potential to improve the safety and efficiency of cell therapy manufacturing, leading to better patient outcomes and a more streamlined production process.

11.
Magn Reson Med ; 90(3): 1130-1136, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37222226

RESUMEN

The British and Irish Chapter of the International Society for Magnetic Resonance in Medicine (BIC-ISMRM) held a workshop entitled "Steps on the path to clinical translation" in Cardiff, UK, on 7th September 2022. The aim of the workshop was to promote discussion within the MR community about the problems and potential solutions for translating quantitative MR (qMR) imaging and spectroscopic biomarkers into clinical application and drug studies. Invited speakers presented the perspectives of radiologists, radiographers, clinical physicists, vendors, imaging Contract/Clinical Research Organizations (CROs), open science networks, metrologists, imaging networks, and those developing consensus methods. A round-table discussion was held in which workshop participants discussed a range of questions pertinent to clinical translation of qMR imaging and spectroscopic biomarkers. Each group summarized their findings via three main conclusions and three further questions. These questions were used as the basis of an online survey of the broader UK MR community.


Asunto(s)
Imagen por Resonancia Magnética , Humanos , Espectroscopía de Resonancia Magnética , Biomarcadores
12.
Radiother Oncol ; 183: 109592, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36870608

RESUMEN

BACKGROUND AND PURPOSE: Tumour hypoxia is prognostic in head and neck cancer (HNC), associated with poor loco-regional control, poor survival and treatment resistance. The advent of hybrid MRI - radiotherapy linear accelerator or 'MR Linac' systems - could permit imaging for treatment adaptation based on hypoxic status. We sought to develop oxygen-enhanced MRI (OE-MRI) in HNC and translate the technique onto an MR Linac system. MATERIALS AND METHODS: MRI sequences were developed in phantoms and 15 healthy participants. Next, 14 HNC patients (with 21 primary or local nodal tumours) were evaluated. Baseline tissue longitudinal relaxation time (T1) was measured alongside the change in 1/T1 (termed ΔR1) between air and oxygen gas breathing phases. We compared results from 1.5 T diagnostic MR and MR Linac systems. RESULTS: Baseline T1 had excellent repeatability in phantoms, healthy participants and patients on both systems. Cohort nasal concha oxygen-induced ΔR1 significantly increased (p < 0.0001) in healthy participants demonstrating OE-MRI feasibility. ΔR1 repeatability coefficients (RC) were 0.023-0.040 s-1 across both MR systems. The tumour ΔR1 RC was 0.013 s-1 and the within-subject coefficient of variation (wCV) was 25% on the diagnostic MR. Tumour ΔR1 RC was 0.020 s-1 and wCV was 33% on the MR Linac. ΔR1 magnitude and time-course trends were similar on both systems. CONCLUSION: We demonstrate first-in-human translation of volumetric, dynamic OE-MRI onto an MR Linac system, yielding repeatable hypoxia biomarkers. Data were equivalent on the diagnostic MR and MR Linac systems. OE-MRI has potential to guide future clinical trials of biology guided adaptive radiotherapy.


Asunto(s)
Neoplasias de Cabeza y Cuello , Oxígeno , Humanos , Imagen por Resonancia Magnética/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Hipoxia , Pronóstico , Aceleradores de Partículas
13.
Clin Cancer Res ; 29(14): 2602-2611, 2023 07 14.
Artículo en Inglés | MEDLINE | ID: mdl-36799931

RESUMEN

PURPOSE: A single maintenance course of a PARP inhibitor (PARPi) improves progression-free survival (PFS) in germline BRCA1/2-mutant high-grade serous ovarian cancer (gBRCAm-HGSOC). The feasibility of a second maintenance course of PARPi was unknown. PATIENTS AND METHODS: Phase II trial with two entry points (EP1, EP2). Patients were recruited prior to rechallenge platinum. Patients with relapsed, gBRCAm-HGSOC were enrolled at EP1 if they were PARPi-naïve. Patients enrolled at EP2 had received their first course of olaparib prior to trial entry. EP1 patients were retreated with olaparib after RECIST complete/partial response (CR/PR) to platinum. EP2 patients were retreated with olaparib ± cediranib after RECIST CR/PR/stable disease to platinum and according to the platinum-free interval. Co-primary outcomes were the proportion of patients who received a second course of olaparib and the proportion who received olaparib retreatment for ≥6 months. Functional homologous recombination deficiency (HRD), somatic copy-number alteration (SCNA), and BRCAm reversions were investigated in tumor and liquid biopsies. RESULTS: Twenty-seven patients were treated (EP1 = 17, EP2 = 10), and 19 were evaluable. Twelve patients (63%) received a second course of olaparib and 4 received olaparib retreatment for ≥6 months. Common grade ≥2 adverse events during olaparib retreatment were anemia, nausea, and fatigue. No cases of MDS/AML occurred. Mean duration of olaparib treatment and retreatment differed (12.1 months vs. 4.4 months; P < 0.001). Functional HRD and SCNA did not predict PFS. A BRCA2 reversion mutation was detected in a post-olaparib liquid biopsy. CONCLUSIONS: A second course of olaparib can be safely administered to women with gBRCAm-HGSOC but is only modestly efficacious. See related commentary by Gonzalez-Ochoa and Oza, p. 2563.


Asunto(s)
Antineoplásicos , Cistadenocarcinoma Seroso , Neoplasias Ováricas , Humanos , Femenino , Inhibidores de Poli(ADP-Ribosa) Polimerasas/efectos adversos , Proteína BRCA1/genética , Proteína BRCA2/genética , Neoplasias Ováricas/tratamiento farmacológico , Neoplasias Ováricas/genética , Neoplasias Ováricas/patología , Carcinoma Epitelial de Ovario/tratamiento farmacológico , Carcinoma Epitelial de Ovario/genética , Antineoplásicos/uso terapéutico , Ftalazinas/efectos adversos , Cistadenocarcinoma Seroso/tratamiento farmacológico , Cistadenocarcinoma Seroso/genética , Recurrencia Local de Neoplasia/tratamiento farmacológico , Recurrencia Local de Neoplasia/genética , Recurrencia Local de Neoplasia/mortalidad
14.
Nat Rev Clin Oncol ; 20(2): 69-82, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36443594

RESUMEN

Computer-extracted tumour characteristics have been incorporated into medical imaging computer-aided diagnosis (CAD) algorithms for decades. With the advent of radiomics, an extension of CAD involving high-throughput computer-extracted quantitative characterization of healthy or pathological structures and processes as captured by medical imaging, interest in such computer-extracted measurements has increased substantially. However, despite the thousands of radiomic studies, the number of settings in which radiomics has been successfully translated into a clinically useful tool or has obtained FDA clearance is comparatively small. This relative dearth might be attributable to factors such as the varying imaging and radiomic feature extraction protocols used from study to study, the numerous potential pitfalls in the analysis of radiomic data, and the lack of studies showing that acting upon a radiomic-based tool leads to a favourable benefit-risk balance for the patient. Several guidelines on specific aspects of radiomic data acquisition and analysis are already available, although a similar roadmap for the overall process of translating radiomics into tools that can be used in clinical care is needed. Herein, we provide 16 criteria for the effective execution of this process in the hopes that they will guide the development of more clinically useful radiomic tests in the future.

17.
Radiother Oncol ; 176: 53-58, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36184998

RESUMEN

PURPOSE: Retrospective studies have identified a link between the average set-up error of lung cancer patients treated with image-guided radiotherapy (IGRT) and survival. The IGRT protocol was subsequently changed to reduce the action threshold. In this study, we use a Bayesian approach to evaluate the clinical impact of this change to practice using routine 'real-world' patient data. METHODS AND MATERIALS: Two cohorts of NSCLC patients treated with IGRT were compared: pre-protocol change (N = 780, 5 mm action threshold) and post-protocol change (N = 411, 2 mm action threshold). Survival models were fitted to each cohort and changes in the hazard ratios (HR) associated with residual set-up errors was assessed. The influence of using an uninformative and a skeptical prior in the model was investigated. RESULTS: Following the reduction of the action threshold, the HR for residual set-up error towards the heart was reduced by up to 10%. Median patient survival increased for patients with set-up errors towards the heart, and remained similar for patients with set-up errors away from the heart. Depending on the prior used, a residual hazard ratio may remain. CONCLUSIONS: Our analysis found a reduced hazard of death and increased survival for patients with residual set-up errors towards versus away from the heart post-protocol change. This study demonstrates the value of a Bayesian approach in the assessment of technical changes in radiotherapy practice and supports the consideration of adopting this approach in further prospective evaluations of changes to clinical practice.


Asunto(s)
Neoplasias Pulmonares , Radioterapia Guiada por Imagen , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Teorema de Bayes , Estudios Retrospectivos , Radioterapia Guiada por Imagen/métodos , Errores de Configuración en Radioterapia , Neoplasias Pulmonares/radioterapia
18.
Insights Imaging ; 13(1): 159, 2022 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-36194301

RESUMEN

BACKGROUND: Lesion/tissue segmentation on digital medical images enables biomarker extraction, image-guided therapy delivery, treatment response measurement, and training/validation for developing artificial intelligence algorithms and workflows. To ensure data reproducibility, criteria for standardised segmentation are critical but currently unavailable. METHODS: A modified Delphi process initiated by the European Imaging Biomarker Alliance (EIBALL) of the European Society of Radiology (ESR) and the European Organisation for Research and Treatment of Cancer (EORTC) Imaging Group was undertaken. Three multidisciplinary task forces addressed modality and image acquisition, segmentation methodology itself, and standards and logistics. Devised survey questions were fed via a facilitator to expert participants. The 58 respondents to Round 1 were invited to participate in Rounds 2-4. Subsequent rounds were informed by responses of previous rounds. RESULTS/CONCLUSIONS: Items with ≥ 75% consensus are considered a recommendation. These include system performance certification, thresholds for image signal-to-noise, contrast-to-noise and tumour-to-background ratios, spatial resolution, and artefact levels. Direct, iterative, and machine or deep learning reconstruction methods, use of a mixture of CE marked and verified research tools were agreed and use of specified reference standards and validation processes considered essential. Operator training and refreshment were considered mandatory for clinical trials and clinical research. Items with a 60-74% agreement require reporting (site-specific accreditation for clinical research, minimal pixel number within lesion segmented, use of post-reconstruction algorithms, operator training refreshment for clinical practice). Items with ≤ 60% agreement are outside current recommendations for segmentation (frequency of system performance tests, use of only CE-marked tools, board certification of operators, frequency of operator refresher training). Recommendations by anatomical area are also specified.

19.
Phys Med ; 101: 165-182, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36055125

RESUMEN

PURPOSE: This overview of the current landscape of quantitative magnetic resonance imaging biomarkers (qMR IBs) aims to support the standardisation of academic IBs to assist their translation to clinical practice. METHODS: We used three complementary approaches to investigate qMR IB use and quality management practices within the UK: 1) a literature search of qMR and quality management terms during 2011-2015 and 2016-2020; 2) a database search for clinical research studies using qMR IBs during 2016-2020; and 3) a survey to ascertain the current availability and quality management practices for clinical MRI scanners and associated equipment at research institutions across the UK. RESULTS: The analysis showed increased use of all qMR methods between the periods 2011-2015 and 2016-2020 and diffusion-tensor MRI and volumetry to be popular methods. However, the "translation ratio" of journal articles to clinical research studies was higher for qMR methods that have evidence of clinical translation via a commercial route, such as fat fraction and T2 mapping. The number of journal articles citing quality management terms doubled between the periods 2011-2015 and 2016-2020; although, its proportion relative to all journal articles only increased by 3.0%. The survey suggested that quality assurance (QA) and quality control (QC) of data acquisition procedures are under-reported in the literature and that QA/QC of acquired data/data analysis are under-developed and lack consistency between institutions. CONCLUSIONS: We summarise current attempts to standardise and translate qMR IBs, and conclude by outlining the ideal quality management practices and providing a gap analysis between current practice and a metrological standard.


Asunto(s)
Biomarcadores , Humanos , Imagen de Difusión Tensora , Imagen por Resonancia Magnética/métodos
20.
Front Oncol ; 12: 899180, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35924167

RESUMEN

Background: Size-based assessments are inaccurate indicators of tumor response in soft-tissue sarcoma (STS), motivating the requirement for new response imaging biomarkers for this rare and heterogeneous disease. In this study, we assess the test-retest repeatability of radiomic features from MR diffusion-weighted imaging (DWI) and derived maps of apparent diffusion coefficient (ADC) in retroperitoneal STS and compare baseline repeatability with changes in radiomic features following radiotherapy (RT). Materials and Methods: Thirty patients with retroperitoneal STS received an MR examination prior to treatment, of whom 23/30 were investigated in our repeatability analysis having received repeat baseline examinations and 14/30 patients were investigated in our post-treatment analysis having received an MR examination after completing pre-operative RT. One hundred and seven radiomic features were extracted from the full manually delineated tumor region using PyRadiomics. Test-retest repeatability was assessed using an intraclass correlation coefficient (baseline ICC), and post-radiotherapy variance analysis (post-RT-IMS) was used to compare the change in radiomic feature value to baseline repeatability. Results: For the ADC maps and DWI images, 101 and 102 features demonstrated good baseline repeatability (baseline ICC > 0.85), respectively. Forty-three and 2 features demonstrated both good baseline repeatability and a high post-RT-IMS (>0.85), respectively. Pearson correlation between the baseline ICC and post-RT-IMS was weak (0.432 and 0.133, respectively). Conclusions: The ADC-based radiomic analysis shows better test-retest repeatability compared with features derived from DWI images in STS, and some of these features are sensitive to post-treatment change. However, good repeatability at baseline does not imply sensitivity to post-treatment change.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA